|
| 1 | Clearing and Grubbing Road Land. Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per MoRD Specification Clause 201. By Mechanical Means. In area of non-thorny jungle |
| 2 | L022-AR KYARIYA |
| 3 | L023-AR HALDURA PHALLA |
| 4 | L025-AR HULRI GHATI |
| 5 | L027-AR THAMLA BERI |
| 6 | Setting Out. Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108. |
| 7 | Working bench mark as per drawing No. 200.1 of MoRD specifications including the cost of material required for construction Height upto 1.00 m from GL |
| 8 | L022-AR KYARIYA |
| 9 | L023-AR HALDURA PHALLA |
| 10 | L025-AR HULRI GHATI |
| 11 | L027-AR THAMLA BERI |
| 12 | Reference pillars / Burjees as per drawing No. 200.2 of MoRD specifications including the cost of material required for construction Height upto 1.00 m from GL |
| 13 | L022-AR KYARIYA |
| 14 | L023-AR HALDURA PHALLA |
| 15 | L025-AR HULRI GHATI |
| 16 | L027-AR THAMLA BERI |
| 17 | Excavation in Soil using Hydraulic Excavatorand Tippers with disposal upto 1000 m. Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRD Specification Clause 302.3 |
| 18 | L022-AR KYARIYA |
| 19 | L023-AR HALDURA PHALLA |
| 20 | L025-AR HULRI GHATI |
| 21 | L027-AR THAMLA BERI |
| 22 | Excavation in Ordinary Rockusing Hydraulic Excavatorand Tippers with disposal upto 1000 m. Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per MoRD Specification Clause 302.3.5 |
| 23 | L022-AR KYARIYA |
| 24 | L023-AR HALDURA PHALLA |
| 25 | L025-AR HULRI GHATI |
| 26 | L027-AR THAMLA BERI |
| 27 | Excavation in Hard Rock (blasting prohibited) Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per MoRD Specification Clause 302.3.5 Mechanical Means |
| 28 | L022-AR KYARIYA |
| 29 | L023-AR HALDURA PHALLA |
| 30 | L025-AR HULRI GHATI |
| 31 | L027-AR THAMLA BERI |
| 32 | Construction of Embankment with Material Obtained from Roadway Cutting. Construction of embankment with approved materials deposited at site obtained from roadway cutting and excavation from drain and foundation or other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per MoRD Specification Clause 301.5 |
| 33 | L022-AR KYARIYA |
| 34 | L023-AR HALDURA PHALLA |
| 35 | L025-AR HULRI GHATI |
| 36 | L027-AR THAMLA BERI |
| 37 | Construction of Embankment with Material Obtained from Borrow Pit. Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Specification Clause 301.5 |
| 38 | L023-AR HALDURA PHALLA |
| 39 | L025-AR HULRI GHATI |
| 40 | L027-AR THAMLA BERI |
| 41 | Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge. |
| 42 | L022-AR KYARIYA |
| 43 | L023-AR HALDURA PHALLA |
| 44 | L025-AR HULRI GHATI |
| 45 | L027-AR THAMLA BERI |
| 46 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per MoRD Specification Clause 303.1. |
| 47 | L022-AR KYARIYA |
| 48 | L023-AR HALDURA PHALLA |
| 49 | L025-AR HULRI GHATI |
| 50 | L027-AR THAMLA BERI |
| 51 | Granular Sub-base with Well Graded Material (Table 400.1) Plant Mix Method ; Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per MoRD Specification Clause 401. For Grading II Material |
| 52 | L022-AR KYARIYA |
| 53 | L023-AR HALDURA PHALLA |
| 54 | L025-AR HULRI GHATI |
| 55 | L027-AR THAMLA BERI |
| 56 | Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and MoRD Specification Clause 406. By Mechanical Means with 1 km lead; Extra rate for carriage of mixed material additional lead from in item 4.9 (Beyond 20th Km) |
| 57 | L022-AR KYARIYA |
| 58 | L023-AR HALDURA PHALLA |
| 59 | L025-AR HULRI GHATI |
| 60 | L027-AR THAMLA BERI |
| 61 | Primer Coat. Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502 |
| 62 | L022-AR KYARIYA |
| 63 | L023-AR HALDURA PHALLA |
| 64 | L025-AR HULRI GHATI |
| 65 | L027-AR THAMLA BERI |
| 66 | Tack coat. Providing and applying tack coat with Bitumen emulsion (RS-1)using emulsiondistributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per MoRD Specification Clause 503. |
| 67 | L022-AR KYARIYA |
| 68 | L023-AR HALDURA PHALLA |
| 69 | L025-AR HULRI GHATI |
| 70 | L027-AR THAMLA BERI |
| 71 | 20mm thick Open-Graded Premix Carpet using Bituminous (Viscosity grade/modified bitumen) Binder. Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 506 & for modified Bitumen Clause 511. By Mechanical Means Bitumen (VG-30) |
| 72 | L022-AR KYARIYA |
| 73 | L023-AR HALDURA PHALLA |
| 74 | L025-AR HULRI GHATI |
| 75 | L027-AR THAMLA BERI |
| 76 | Seal Coat. Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per MoRD Specification Clause 508 & modified Bitumen Clause 511 By Mechanical Means. Case - II :Type B. Bitumen (VG-30) |
| 77 | L022-AR KYARIYA |
| 78 | L023-AR HALDURA PHALLA |
| 79 | L025-AR HULRI GHATI |
| 80 | L027-AR THAMLA BERI |
| 81 | Add extra for adding Shreaded Plastic Waste as per Guidelines envisaged in IRC:SP:98-2013 over Item No. 5.9 of Bitumenous Surface Course @ 8% of the quantity of Bitumen by weight including mixing of aggregate and plastic waste in Hot Mix Plant( The Bitumen content will be as per respective Clause of MoRD Specifications) |
| 82 | L022-AR KYARIYA |
| 83 | L023-AR HALDURA PHALLA |
| 84 | L025-AR HULRI GHATI |
| 85 | L027-AR THAMLA BERI |
| 86 | Construction of panel concrete pavement M-40 grade for Thin White Topping (Thickness greater than I00 mm and less than 200 mm) Construction of short paneled un reinforced,plain cement concrete pavement (Thin white Topping as per IRC : SP: 76-2015) :M-40 grade concrete over a prepared sub base or over bituminous surface (Existing bituminous surface prepared if necessary either by milling or leveling course to be done with BM / DBM / DLC to correct surface profile and to be paid separately)with Ordinary Portland Cement 53 grade confirming to IS:12269,coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 31.5 mm , mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and |
| 87 | expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days, using curing compound (where specified) and water including vaccum dewatering process with all required equipments, finishing to lines and grade as per drawing and MoRD specification Clause 1501 complete excluding cost of steel in dowel bars and tie bars etc. Each Panel (1.00m x 1.00m).Note : If fiber are to be used as per mix design the same shall be paid separately as per item no 6.8 |
| 88 | L023-AR HALDURA PHALLA |
| 89 | L025-AR HULRI GHATI |
| 90 | L027-AR THAMLA BERI |
| 91 | KilometreStone. Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 |
| 92 | Ordinary Km stone (Precast) |
| 93 | L022-AR KYARIYA |
| 94 | L023-AR HALDURA PHALLA |
| 95 | L025-AR HULRI GHATI |
| 96 | L027-AR THAMLA BERI |
| 97 | 200 m stone (Precast) |
| 98 | L022-AR KYARIYA |
| 99 | L023-AR HALDURA PHALLA |
| 100 | L025-AR HULRI GHATI |
| 101 | L027-AR THAMLA BERI |
| 102 | Supplying and fixing cut stone including earthwork, cement concrete 1 : 4 : 8 engraving letters and numerals, painting with enamel paint etc. complete as per IRC standard design. Guide Stone ( Size 20 x 15 x 120 cm ) |
| 103 | L022-AR KYARIYA |
| 104 | L023-AR HALDURA PHALLA |
| 105 | L025-AR HULRI GHATI |
| 106 | L027-AR THAMLA BERI |
| 107 | Providing and Fixing informatory sign board with Logo of PMGSY Project. Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. |
| 108 | The top of the middle plate will be flushed with the top of 75 mm dia medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height asper approved drawing and MoRD Specification Clause 1700 |
| 109 | L022-AR KYARIYA |
| 110 | L023-AR HALDURA PHALLA |
| 111 | L025-AR HULRI GHATI |
| 112 | L027-AR THAMLA BERI |
| 113 | Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 3mm thick plate of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edgesincluding orange luminous colour epoxy paint on logo, size ofdefinition plate 900x300mm supported on MS post of square hollow section 75x75x6mm, 3m long .The lettering and borders, etc. of definition plate and PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.Posts will be fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700 |
| 114 | L022-AR KYARIYA |
| 115 | L023-AR HALDURA PHALLA |
| 116 | L025-AR HULRI GHATI |
| 117 | L027-AR THAMLA BERI |
| 118 | Providing and Erecting typical Citizen\"s information Board as per approved drawing & specification of MORD made of Two plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900 mm x 750 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. Frame will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. ofplates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done asper approved drawing and MoRD Specification Clause 1700 |
| 119 | L022-AR KYARIYA |
| 120 | L023-AR HALDURA PHALLA |
| 121 | L025-AR HULRI GHATI |
| 122 | L027-AR THAMLA BERI |
| 123 | Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160\" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements. |
| 124 | L022-AR KYARIYA |
| 125 | L023-AR HALDURA PHALLA |
| 126 | L025-AR HULRI GHATI |
| 127 | L027-AR THAMLA BERI |
| 128 | Traffic Signs. Retro-reflectorised Traffic Signs.Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and MoRD Specification Clause 801 : 600 mm equilateral triangle |
| 129 | L022-AR KYARIYA |
| 130 | L023-AR HALDURA PHALLA |
| 131 | L025-AR HULRI GHATI |
| 132 | L027-AR THAMLA BERI |
| 133 | Direction and Place Identification signs upto 0.9 sqm size board. Retro-reflectorised Traffic Signs Providing and erecting direction and place identification retroreflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1701 upto 0.9 sqm size board |
| 134 | L022-AR KYARIYA |
| 135 | L023-AR HALDURA PHALLA |
| 136 | L025-AR HULRI GHATI |
| 137 | L027-AR THAMLA BERI |
| 138 | Supplying of Cat’s Eye made of ABS Material having high reflective reflectors molded in PMMA material are fitted on the Stud. The reflectors are welded with a ABS base plate through ultrasonic welding process. |
| 139 | L022-AR KYARIYA |
| 140 | L023-AR HALDURA PHALLA |
| 141 | L025-AR HULRI GHATI |
| 142 | L027-AR THAMLA BERI |
| 143 | Excavation for Structures. Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 144 | Ordinary Soil. Upto 3 m depth. |
| 145 | L022-AR KYARIYA |
| 146 | L023-AR HALDURA PHALLA |
| 147 | L025-AR HULRI GHATI |
| 148 | L027-AR THAMLA BERI |
| 149 | Ordinary rock (not requiring blasting) |
| 150 | L022-AR KYARIYA |
| 151 | L023-AR HALDURA PHALLA |
| 152 | L025-AR HULRI GHATI |
| 153 | L027-AR THAMLA BERI |
| 154 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10. Nominal mix 1:3:6 |
| 155 | L022-AR KYARIYA |
| 156 | L023-AR HALDURA PHALLA |
| 157 | L025-AR HULRI GHATI |
| 158 | L027-AR THAMLA BERI |
| 159 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 . Nominal mix (1:2:4) |
| 160 | L022-AR KYARIYA |
| 161 | L023-AR HALDURA PHALLA |
| 162 | L025-AR HULRI GHATI |
| 163 | L027-AR THAMLA BERI |
| 164 | Plain/reinforced cement concrete in substructure complete as per drawings and MoRD specification Clauses 802, 804, 805, 806, 807, 1202 and 1204. For height upto 5 m. P.C.C. grade M 20. Nominal mix (1:2:4) |
| 165 | L022-AR KYARIYA |
| 166 | L023-AR HALDURA PHALLA |
| 167 | L025-AR HULRI GHATI |
| 168 | L027-AR THAMLA BERI |
| 169 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and MoRD specification Clauses 1002, 1005, 1010 & 1202 |
| 170 | L022-AR KYARIYA |
| 171 | L023-AR HALDURA PHALLA |
| 172 | L025-AR HULRI GHATI |
| 173 | L027-AR THAMLA BERI |
| 174 | Providing and laying reinforced cement concrete in superstructure as per drawing and MoRD specifications Clauses 800, 1205.4 and 1205.5 For height upto 5 m R.C.C M 25 |
| 175 | L025-AR HULRI GHATI |
| 176 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row. Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 1000 mm dia |
| 177 | L022-AR KYARIYA |
| 178 | L023-AR HALDURA PHALLA |
| 179 | L025-AR HULRI GHATI |
| 180 | L027-AR THAMLA BERI |
| 181 | Providing and Laying Reinforced Cement Concrete Pipe NP3as per Design in Double Row. Providing and laying reinforced cement concrete pipe NP3for culverts on first class bedding of granularmaterial in double row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. 1000 mm dia |
| 182 | L022-AR KYARIYA |
| 183 | L023-AR HALDURA PHALLA |
| 184 | L025-AR HULRI GHATI |
| 185 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row . Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 300 mm dia |
| 186 | L023-AR HALDURA PHALLA |
| 187 | L025-AR HULRI GHATI |
| 188 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD specification Clauses 614, 709, 1204.3.7 |
| 189 | L022-AR KYARIYA |
| 190 | L023-AR HALDURA PHALLA |
| 191 | L025-AR HULRI GHATI |
| 192 | L027-AR THAMLA BERI |
| 193 | Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRD specifications Clauses 1001 and 1401 |
| 194 | L025-AR HULRI GHATI |
| 195 | Add GST (18%) on Total Costruction Cost |
| 196 | Routine Mainteenance work After Completion of works for Five Year Fixed Amount |
| 197 | For 1st Year (0.68%) |
| 198 | For 2nd Year (0.87%) |
| 199 | For 3rd Year (1.12%) |
| 200 | For 4th Year (1.31%) |
| 201 | For 5th Year (1.52%) |
| 202 | Add GST (18%) on Total Maintenance Cost |