| 1 | Supplying and laying in replacement of GI tubing medium grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of following size, complete all as specified and directed by Engr-in-Charge. |
| 2 | 100 mm bore |
| 3 | 80 mm bore |
| 4 | 50 mm bore |
| 5 | Taking down old unserviceable LT UG cables from trench/poles/wall etc of following size, complete all as specified and directed by Engr-in-Charge. |
| 6 | 25 Sqmm 4 core |
| 7 | 35 Sqmm 3.5 core |
| 8 | 50 Sqmm 3.5 core |
| 9 | 70 Sqmm 3.5 core |
| 10 | 95 Sqmm 3.5 core |
| 11 | 120Sqmm 3.5 core |
| 12 | 150Sqmm 3.5 core |
| 13 | 185Sqmm 3.5 core |
| 14 | 240Sqmm 3.5 core |
| 15 | 300Sqmm 3.5 core |
| 16 | 400Sqmm 3.5 core |
| 17 | Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes, complete all as specified and directed by Engr-in-Charge. |
| 18 | 10 Sqmm 4 core |
| 19 | 16 Sqmm 4 core |
| 20 | 25 Sqmm 4 core |
| 21 | 35 Sqmm 3.5 core |
| 22 | 50 Sqmm 3.5 core |
| 23 | 70 Sqmm 3.5 core |
| 24 | 95 Sqmm 3.5 core |
| 25 | 120Sqmm 3.5 core |
| 26 | 150Sqmm 3.5 core |
| 27 | 185Sqmm 3.5 core |
| 28 | 240Sqmm 3.5 core |
| 29 | 300Sqmm 3.5 core |
| 30 | 400Sqmm 3.5 core |
| 31 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge. |
| 32 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well rammingin layers n. exc. 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 33 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 34 | Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc.,with smooth internal and profiled external surface for non pressure under ground cable, complete all as specified and directed by Engr-in-Charge. |
| 35 | Description all as per ser item No 7.00 here-in-before but outer dia of 63 mm and inner dia 50 mm. |
| 36 | Description all as per ser item No 7.00 here-in-beforebut outer dia of 77 mm and inner dia 63 mm. |
| 37 | Description all as per ser item No 7.00 here-in-beforebut outer dia of 90 mm and inner dia 76 mm . |
| 38 | Description all as per ser item No 7.00 here-in-beforebut outer dia of 110 mm and inner dia 95 mm. |
| 39 | Description all as per ser item No 7.00 here-in-before but outer dia of 120 mm and inner dia 103.5 mm. |
| 40 | Description all as per ser item No 7.00 here-in-beforebut outer dia of 160mm and inner dia 126 mm. |
| 41 | M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 2009 & & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm),funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc, complete all as specified and directed by Engr-in-Charge. |
| 42 | Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth strip 32X6 mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:3:6 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009, complete all as specified and directed by Engr-in-Charge. |
| 43 | Supply and fix earth pit chamber board of 3.15mm thick mild steel sheet of size min 45 cm X 30 cm fixed with12mm thick MS rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e Earth pit No, Location, Earthing test Value and date and other letters, complete all as specified and directed by Engr-in-Charge. |
| 44 | Material and labour for repairs of earthing chamber of size min 450x450x300mm depth outside & min 250x250x250 mm depth of PCC (1:4:8) type D-2 & including provn of PCC cover including painting of two coat, complete all as specified and directed by Engr-in-Charge. |
| 45 | Material and labour for Painting of earth pit chamber with two coat of acrylic emulsion paint including making the earth pit and colour of paint, complete all as specified and directed by Engr-in-Charge. |
| 46 | S & F GI earth continuity conductor or main earthing lead of size 32X6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc, complete all as specified and directed by Engr-in-Charge. |
| 47 | S & F copper earth continuity conductor or main earthing lead of size 25x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc, complete all as specified and directed by Engr-in-Charge. |
| 48 | Supplying and laying in replacement of GI tubing light grade 40mm bore forprotection of strip fixing to pole/wall or in such similar position, complete all as specified and directed by Engr-in-Charge. |
| 49 | M&L for providing cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate ) as in hard standing after laying cable under road etc, complete all as specified and directed by Engr-in-Charge. |
| 50 | M&L for cutting of road for passing Cables under road along with GI pipes, complete all as specified and directed by Engr-in-Charge. |
| 51 | Design, Supply, installing testing and commissioning factory fabricated In door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. Including Supply and fixing the following :- |
| 52 | Incoming -(a) ACB 1000 Amps 4 Pole -01 NoOutgoings - (a) MCCB TPN 400 Amps 50 Hz, 415 V with rupturing capacity 50 KA-4 Nos (b) MCCB TPN 250 Amps 50 Hz, 415 V with rupturing capacity 35 KA-02 Nos (c) MCCB TPN 200 Amps 50 Hz, 415 V with rupturing capacity 35 KA - 02 Nos(d) Voltmeter 0-500V with selector switch (Digital type)-01 No.(e) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No(f) Indicating lamps (RYB) -01 Set(g) PCC Foundation (Civil works) for grouting of panel(h) Bus bar 1500 Amps(i) total two nos number combination padlock (one on each door of panel) |
| 53 | Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.15 mm thick CRCA sheet double door,CPRIapproved of size not less than 600X600X300 mm complete with powder coating with seven tank process mounted on M.Sangle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following:-Incoming:- (a) S&F MCCB FP 630 Amps 35 KA - 01 No.Out going:- (a) S & F Aluminium bus bar 1200 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(b) Voltmeter 0-500V with selector switch (Digital type)-01 No(c) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No(d) Indicating lamps (RYB) -01 Set. (e) PCC Foundation (Civil works) for grouting of panel(f)total two nos number combination padlock (one on each door of panel) |
| 54 | S&F energy efficient bollard garden light, 360 degree light distribution with IP-65 ,min 85.5 CM height and 17.4 cm widthfitting on ground , wall etc including excavation and PCC 300cmx300cm and high quality integrated LEDs assure soothing warm white light all night long LED 9/10 Wblack case aluminuim , synthetic model Robin including all necessary wiring LED bulb , clamps, nut and bolts mounting accessories etc all as specified and directed by Engr-in-Charge. |
| 55 | S&F bright Flood light fitting LED type,70 Watts 240 Volts luminousefficiency not less than 100 lm/Watt ,PDC housing with IP 65 flood lightsleek and robust design for better aesthetics,reliable and sturdy, mounted on wall and providing connection completeall as specified and directed by Engr-in-Charge |
| 56 | Material and labour for terminal box made out of SMC with hinged door and locking arrangements of size 260x260x 150mm, including Backlite 4 way connector,M.S. Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer,electrical connections including MCB TPN 6-32 Amps complete all as specified and as directed by Engr-in-Charge. |
| 57 | Supply, Install, Test and Commissioning of LT street light panel outdoor type fabricated out of 3.15 mm thick CRCA sheet double door type IP-65,CPRIapproved of size 600X600X300 mm complete with powder coating with seven tank process mounted on M.Sangle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following:-(i) Automatic street light control switch of 18-21 KW three phase(40 Amp per phase) having protection IP-66 using Astro sensor andInfrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitable rating power contractor (s), one Incoming and three Outgoing MCBs rating of 63AAmps 4 pole 10 KA & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection. The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed. |