| 1 | Excavating in post holes (or similar holes) in any type ofsoil, each n.exc 0.5 cum, getting out and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed. |
| 2 | S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-Acomplete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 3 | S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 5 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. |
| 6 | S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight per sqm not exc 4kg complete all as specified and as directed. |
| 7 | Demolition of reinforcement cement Concrete of any description and in any position not otherwise specifically provided for including(reinforcement required to faciliate demolition) up to and including on the rooftop/mumty/parapet/RCC chajjas/RCC water tank and removal of debris and rubbish out side of MoD land complete all as specified and directed. |
| 8 | M&L for precast cement concrete (1:2:4) type B1, (using 20mm graded stone aggregates) asin landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs,mangers, shelves and similar articles with plain faces set in CM (1:4) including necessary fair finish formwork complete all as specified and directed. |
| 9 | M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 10 | Excavating over areas, n exc 1.5m deep and gettingout in any type of soil complete all as specified and directed. |
| 11 | M&L for hard core of broken boulders/stone of gauge n exc. 63 mm, deposited, spread,and levellled in layersnot exceeding 15 cm thick each layer water andrammed to a true surface complete all as specified and directed. |
| 12 | Removing excavated material (soil) n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 13 | M&L for PCC (1:4:8) Type D2 ( using 40 mm gradedstone aggre-gate) as in foundations, filling and mass-concrete or sub base of floor/ hard standing/ footpath etc complete all as specified and directed. |
| 14 | Formwork to Rough finished surfaces ofconcrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 15 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete block walling complete all as specified and directed. |
| 16 | M&L for brick work with old size full bricksubclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 17 | M&L for brick work with old size half bricksubclass ‘B’ burnt clay bricks, straight or curved on plan to any radius radius, built in CM (1:4) complete all as specified and directed. |
| 18 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out sideof MoD land complete all as specified and as directed. |
| 19 | M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and smooth w/o using extra cement mixed with integral water proofing compound complete all as specified and directed.Note :- WPC (Liquid type) shall be measured and paid separately as supply only. |
| 20 | Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. |
| 21 | Supply, fixing and testing of centrifugal pumpset 30 HP to feed water in Pressure filter for operational flow rate of 2700 LPM and operating work pressure of 30 M head all as specified and directed. |
| 22 | Supply, installation, fixing of multigrade Sand Media filteration system of 2500-2800 LPM capacity consisting of vertical pressure filter fabricated from high performance MS structural pressure vessel of 8 mm thick plate & 10 mm dish end with epoxy paint outside and inside having collection system complete with MSEP piping, flanges with 3-5 mm thick gasket, nut bolt washers were required & all accesories tested to 10 Kg/m2 including leg all respect as required to remove the total suspended turbidity, solids, dirt, iron andreduce silt density index from the water. Filter media consisting of (i) Gravels (ii) Pebbles (iiii) Quartz, (iv) sand 50 micron particular size etc including necessary piping arrangement of MS pipe size 150 mm dia bore, 02 Nos pressure gauge and neccesary valves including testing complete. |
| 23 | Supply, installation, fixing of carbon filteration system of 2500-2800 LPM capacity consisting of vertical pressure filter fabricated from high performance MS structural pressure vessel of 8 mm thick plate & 10 mm dish end with epoxy paint outside and inside having collection system complete with MSEP piping, flanges with 3-5 mm thick gasket, nut bolt washers were required & all accesories tested to 10 Kg/m2 including leg all respect as required to remove the color & free gases from the water. Filter media consisting of activated carbon media for Free Gases, color, odor etc including necessary piping arrangement of MS pipe size 150 mm dia bore, 02 Nos pressure gauge and neccesary valves including testing complete all as specified and as directed. |
| 24 | Supply, installation and testing of chemical dosing pump, mechanically actuated diaphragm type of capacity 30 ltrs/ hr with 10 kg back pressure including all necessary connections, plumbing,clamping work complete all as specified and as directed. |
| 25 | Supply, installation and testing of FRP made solution preparation tank 100 Ltr Capacity with lid,port hole,inlet/outlet/drain connection,level gauge etc and fitted with 900 RPM motor & PVC agitator combined with DOSING Tank of 100 Ltr Capacitywith lid,port hole,inlet/outlet/drain connection,level gauge etc either fitted with 900 RPM motor and PVC agitator complete all necessary connections and all as specified and directed. |
| 26 | Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proof openablefrom both front and rear side made of2.00 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- |
| 27 | Aluminium Bus bar 200 Amps |
| 28 | Incoming MCCB, 4 pole, 125 Amps, 415 Volt AC, 25 KA rupturing capacity- 1 nos |
| 29 | Outgoing MCCB, 3 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacity- 2 nos |
| 30 | Star delta starter30 HP -02 Nos |
| 31 | Outgoing MCB 4 pole 32 Amps, 10 kA, 240 volts - 01 No(Spare ) |
| 32 | Metering and accessories |
| 33 | Supply & Fixing CI Foot valve of size 150 mm dia completeincluding rubber / fiber board ,gasket,nuts, washer etccomplete all as specified and as directed. |
| 34 | Supply & Fixing CI NRV/reflux valve with bypass arrangement of size 150 mm dia with fly nut flanged both ends and drilled for jointing wheel head type conforming to IS 14846 including two flanged joints with nuts bolts and washers rubber insertion packing etc complete with gun metal or stainless steel spindle and cast iron hand wheel including rubber / fiber board gasket,nuts,bolts, washer etc required at site for proper installation, complete all as specified and as directed. |
| 35 | Excavating in trenches n exc 1.5 m width and n exc 1.5 m in depth for foundation etc / for laying of cable/ pipe etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 36 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. |
| 37 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed.Note:- Punned thickness shall be considered for payment purpose. |
| 38 | Supply and laying cable protection bricks, common burnt clay sub class \"B\" designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. |
| 39 | M&L for road/hard standing cutting for laying cable and through GI Pipe of 50 mm light grade making good with PCC 1:3:6 type C-2(using 40 mm graded stone aggregate) of 100mm X 100mm inrespect ofwidth and thickness complete all as specified and directed. |
| 40 | Supply and fixingin repair GI tubing light grade 50mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under load etc for cable protection complete all as specified and directed. |
| 41 | M & L for MS Black pipe having thickness 5.00 mmwith all fittings of size 200 mm bore medium grade ISI Markedwith all fittings complete all as specified and as directed. |
| 42 | M & L for MS Black pipe heavy gradewith all fittings of size 150 mm bore medium grade ISI Markedwith all fittings complete all as specified and as directed. |
| 43 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and as directed. |
| 44 | Supply, laying and testing cable PVC Insulated ,screened, PVC bedded, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 25 sq mm 3 core. (02 Run @ each pump) complete all as specified and as directed. |