| 1 | Supplying and laying in replacement of GI tubing medium grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of following size, complete all as specified and directed by Engr-in-Charge:- |
| 2 | 100 mm bore |
| 3 | 80 mm bore |
| 4 | 50 mm bore |
| 5 | Taking up old unserviceable LT UG cables from trench/poles/wall etc of following size, complete all as specified and directed by Engr-in-Charge: |
| 6 | 25 Sqmm 4 core |
| 7 | 35 Sqmm 3.5 core |
| 8 | 50 Sqmm 3.5 core |
| 9 | 70 Sqmm 3.5 core |
| 10 | 95 Sqmm 3.5 core |
| 11 | 120Sqmm 3.5 core |
| 12 | 150Sqmm 3.5 core |
| 13 | 185Sqmm 3.5 core |
| 14 | 240Sqmm 3.5 core |
| 15 | 300Sqmm 3.5 core |
| 16 | Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes, complete all as specified and directed by Engr-in-Charge: |
| 17 | 25 Sqmm 4 core |
| 18 | 35 Sqmm 3.5 core |
| 19 | 50 Sqmm 3.5 core |
| 20 | 70 Sqmm 3.5 core |
| 21 | 95 Sqmm 3.5 core |
| 22 | 120Sqmm 3.5 core |
| 23 | 150Sqmm 3.5 core |
| 24 | 185Sqmm 3.5 core |
| 25 | 240Sqmm 3.5 core |
| 26 | 300Sqmm 3.5 core |
| 27 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge. |
| 28 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well rammingin layers n. exc. 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 29 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 30 | Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc.,with smooth internal and profiled external surface for non pressure under ground cable, complete all as specified and directed by Engr-in-Charge. |
| 31 | Description all as per ser item No 7.00 here-in-before but outer dia of 63 mm and inner dia 50 mm. |
| 32 | Description all as per ser item No 7.00 here-in-before but outer dia of 77 mm and inner dia 63 mm. |
| 33 | Description all as per ser item No 7.00 here-in-before but outer dia of 90 mm and inner dia 76 mm . |
| 34 | Description all as per ser item No 7.00 here-in-before but outer dia of 110 mm and inner dia 95 mm. |
| 35 | Description all as per ser item No 7.00 here-in-before but outer dia of 120 mm and inner dia 103.5 mm. |
| 36 | Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth strip 32X6 mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:3:6 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 all as specified and directed.Note :- Contractor Shall provide earth pit chamber board of 3.15mm thick mild steel sheet of size min 45cmX30cm fixed with12mm thick MS rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e Eart pit No, Location, Earthing test Value and date complete and other letters, complete all as specified and directed by Engr-in-Charge. |
| 37 | S & F GI earth continuity conductor or main earthing lead of size 32X6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required, complete all as specified and directed by Engr-in-Charge. |
| 38 | Supplying and laying in replacement of GI tubing light grade 40mm bore forprotection of strip fixing to pole/wall or in such similar position, complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for providing cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate ) as in hard standing after laying cable under roadetc, complete all as specified and directed by Engr-in-Charge. |
| 40 | M&L for cutting of road for passing Cables under road along with GI pipes, complete all as specified and directed by Engr-in-Charge. |
| 41 | Design, Supply, installing testing and commissioning factory fabricated In door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. Including Supply and fixing the following :- |
| 42 | Incoming :- (a) MCCB 630 Amps 4 Pole -03 Nos(b) Change over switch 630 Amps 04 Pole-02 Nos Outgoing :- (a) MCCB TPN 400 Amps 50 Hz, 415 V with rupturing capacity 50 KA- 04 Nos (b) MCCB TPN 250 Amps 50 Hz, 415 V with rupturing capacity 35 KA-02 Nos (c) MCCB TPN 200 Amps 50 Hz, 415 V with rupturing capacity 35 KA - 02 Nos (d) Voltmeter 0-500V with selector switch (Digital type)-01 No.(e) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No.(f) Indicating lamps (RYB) -01 Set(g) PCC Foundation (Civil works) for grouting of panel(h) Bus bar 1200 Amps(i) total two nos number combination padlock (one on each door of panel) |
| 43 | Design, Supply, installing testing and commissioning factory fabricated In door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. Including Supply and fixing the following :- |
| 44 | Incoming :- (a) MCCB 400 Amps 4 Pole -02 Nos .Outgoing :- (a) C/O switch 400 Amps - 01 No (b) MCCB 4 Pole 250 Amps 50 Hz, 415 V with rupturing capacity 50 KA-4 No (b) MCCB TPN 200 Amps 50 Hz, 415 V with rupturing capacity 35 KA-02 Nos (c) MCCB TPN 200 Amps 50 Hz, 415 V with rupturing capacity 35 KA - 02 Nos (d) Voltmeter 0-500V with selector switch (Digital type)-01 No.(e) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No.(f) Indicating lamps (RYB) -01 Set(g) PCC Foundation (Civil works) for grouting of panel(h) Bus bar 600 Amps(i) total two nos number combination padlock (one on each door of panel) |
| 45 | Design, Supply, installing testing and commissioning factory fabricated In door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. Including Supply and fixing the following :- |
| 46 | Incoming :- (a) MCCB 400 Amps 4 Pole -01 NoOutgoing :- (a) MCCB 4 Pole 200 Amps 50 Hz, 415 V with rupturing capacity 50 KA-2 Nos(b) MCCB TPN 100 Amps 50 Hz, 415 V with rupturing capacity 35 KA-03 Nos (c) Voltmeter 0-500V with selector switch (Digital type)-01 No.(d) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No.(e) Indicating lamps (RYB) -01 Set(f) PCC Foundation (Civil works) for grouting of panel(g) Bus bar 600 Amps(i) total two nos number combination padlock (one on each door of panel) |
| 47 | Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.15 mm thick CRCA sheet double door,CPRIapproved of size not less than 600X600X300 mm complete with powder coating with seven tank process mounted on M.Sangle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following:-Incoming:- (a) S&F MCCB FP 400 Amps 35 KA - 01 No.Outgoing :- (a) MCCB 160 Amps 4 pole 25 KA- 04 Nos(b) S & F copper bus bar 600 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(c) Voltmeter 0-500V with selector switch (Digital type)-01 No(d) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No(e) Indicating lamps (RYB) -01 Set. (f) PCC Foundation (Civil works) for grouting of panel(g) total two nos number combination padlock (one on each door of panel) |
| 48 | Supply , install , testing and commissioning of wire mesh cable tray hot dip galvanised type of size of 105 mm height X 600 mm width, 3 meter length each as per EN 12329 and IEC 61537 with wire diameter of 3.9 to 5.9 mm and having SST of 550 Hrs tested , having E30/E90 certification, with following specification, complete all as specified and directed by Egnr-in-Charge.Make: Legrand/C&S/L&Ti) C41S/RCSN/R35 (wall/celling/ground mounting supports) every after 1 meter distance.ii) Kitaster coupler (Jointing tray ) 5 sets per joint.iii) Down rod of 1 meter length each.iv) Nuts 3 nos for each rod.v) COUPFIL(Cutter) 01 No.vi) L supports for wall with all accessories such as nut ,bolt ,washers etc.Note :- a) Shifting of all existing HT and LT cables, Removing connections of these cables and refixing at its original position through cable trays in a proper manner all as directed by engr in charge is included in the quoted rates.b) All major and minor spares are required in laying of cables and fixing of cable trays which are not mention above are included in the quoted rates.c) All material such as cement ,concerete,tiles etc to make wall/roof /ground in its original shape after fixing of cable trays are included in the quoted rates. |
| 49 | Supply, Install, Test and Commissioning of wall mounted LT feeder pillar box indoor type fabricated out of 3.0 mm thick CRCA sheet double door,CPRIapproved of size not less than 600X600X300 mm complete with powder coating with seven tank process mounted on M.Sangle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following:-Incoming:- (a) S&F MCCB FP 125 Amps 35 KA - 01 No.Outgoing :- (a) MCB 40/63 Amps 10 KA- 05 Nos(b) S & F aluminium bus bar 600 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(c) Voltmeter 0-500V with selector switch (Digital type)-01 No(d) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No(e) Indicating lamps (RYB) -01 Set. (f) PCC Foundation (Civil works) for grouting of panel |
| 50 | Design, Supply, installing testing and commissioning factory fabricated In door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. Including Supply and fixing the following :- |
| 51 | Incoming :- (a) MCCB 630 Amps 4 Pole -01 NosOutgoing :- (a) Voltmeter 0-500V with selector switch (Digital type)-01 No.(b) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No.(c) Indicating lamps (RYB) -01 Set(d) PCC Foundation (Civil works) for grouting of panel(e) Bus bar 1200 Amps(f) total two nos number combination padlock (one on each door of panel) |