| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, laying of sewer lines, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed |
| 2 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but n exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of sewer lines etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed |
| 3 | Demolition and breaking up 150mm dia drain pipes (salt glazed ware,AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 4 | Demolition and breaking up 200mm dia drain pipes (salt glazed ware,AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 5 | Demolition and breaking up 300mm dia drain pipes (salt glazed ware,AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 6 | M&L for 150 mm bore Reinforced concrete pipe class NP2, laid and jointed complete with collars all as specified and directed. |
| 7 | M&L for 200 mm bore Reinforced concrete pipe class NP2, laid and jointed complete with collars all as specified and directed. |
| 8 | M&L for 300 mm bore Reinforced concrete pipe class NP2, laid and jointed complete with collars all as specified and directed. |
| 9 | M&L concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 mix, type C2 (using 40 mm graded stone aggregate) for 150mm dia pipe complete all as specified and directed |
| 10 | M&L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 mix, type C2 (using 40 mm graded stone aggregate) for 200 mm dia pipe complete all as specified and directed |
| 11 | M&L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 mix, type C2 (using 40 mm graded stone aggregate) for 300 mm dia pipe complete all as specified and directed |
| 12 | M&L for cutting into existing manholes for connecting new drains 200mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed. |
| 13 | Demolition of brickwork, precast concrete block, stone /boulder masonry built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facingscomplete all as specified and directed |
| 14 | M&L Brick work with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified anddirected. |
| 15 | Demolition of cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 16 | M&L for providing plaincement concrete 1:4:8type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete completeall as specified and directed. |
| 17 | M&L cement concrete 1:2:4 mix, type B2 (using 40mm graded stone aggregate) in benching of manhole including finishing the top of benching even and smooth using extra cement for coving complete all as specified and directed |
| 18 | M&L cement concrete 1:3:6 Mix, type C1 (using 20 mm graded stone aggregate) as in coping including necessary form work complete all as specified and directed |
| 19 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitatedemolition) complete all as specified and directed. |
| 20 | M&L for providing precastcement concrete 1:2:4type B-1 (using 20mm graded aggregate)set in cement mortar 1:4as incover slab supported on wallcomplete all as specified and directed |
| 21 | S&F MS steel TMT bars 6mm to 8mm dia cutcutto length ,bent to shaprequired including cranking bending for hooping for column ,hooking ends and bindings with and including mild steel wire (annealel) not less than 0.9mm dia complete all as specified and directed. |
| 22 | Taking down cementplaster of any description on brick or stone wall/ celling including raking out joint , hacking for key and scrubing with water etc. complete all as specified and directed. |
| 23 | M&L rendering 15mm thick cement plaster on fair faces of brick surface/ concrete surfaces in CM 1:4finished even and smooth without using extra cement complete all as specified and directed. |
| 24 | Retunning filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in layer complete all as specified and directed. |
| 25 | Removing excavated materials not exc. 50m and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed. |
| 26 | S&F in repairs vitreous china wash down water closet pan and trap (pedestal pattern), white (excluding fixing bolt flushing cistern and flush pipe) complete all as specified and directed. |
| 27 | S&F in repairs 15 mm bore CP brass bib tap fancy type screwed down screwed for iron pipe complete all as specified.(ISI marked) complete all as specified and directed. |
| 28 | S&F15 mm dia bore Toilet hand shower (Health Faucet) with 8 mm dia and 1.00 mtr long flexible tube and wall hookcomplete all as specified and directed. |
| 29 | S & F in repair15 mm dia Fancy type Chromium plated Angle valves, cast copper alloy screwed down high pressure, with crutch or butterfl y handle, screwed both ends for iron pipe or for unionscomplete all as specified and directed. |
| 30 | S&F in repair PVC connection 15mm sizewith PTMT nuts of length 60cm complete all as specified and directed. |
| 31 | S&F in repairs PVC valve 10 Ltr capacity symphonic action type flushing cistern low level white with inlet ball valve float and handle push type incl. Flush pipe 32 mm dia and connecting to WC complete all as specified and directed. |
| 32 | Dismantling 75/100mm dia cast iron drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 33 | S&F 100mm did Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors / wall complete all as specified and directed. |
| 34 | S&F 75mm did Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors/wall complete all as specified and directed. |
| 35 | S&F 100mm Junction, single, equal or unequal, ordinary or inverted with spigot or socket branch complete all as specified and directed. |
| 36 | M&LSalt-glazed stoneware gully traps 150x150mm, square or round mouthed, tvpe \"P\" complete all as specified and directed. |
| 37 | S&F in repair 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor allas complete all as specified and directed. |
| 38 | S&F in repair 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor all as complete all as specified and directed. |
| 39 | S&F 110 mm dia PVC (SWR) bends any length any type complete all as specified and directed. |
| 40 | S&F 75 mm dia PVC (SWR) bends any length any type complete all as specified and directed. |
| 41 | S&F 110mm PVC (SWR) branch piece double (double Y) equal or unequal complete all as specified and directed. |
| 42 | S&F 75mm PVC (SWR) branch piece double (double Y) equal or unequal complete all as specified and directed. |
| 43 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 44 | M&L Machine pressed precast concrete interlocking paver block of approved quality set & jointed in cement slurry and pointed in grey cement and no pigment to match confirming to IS 15658-2006 of 60mm thick M-35 grade complete all as specified and directed. |
| 45 | M&L for sand filling under interlocking paver block including watering and consolidation complete all as specified and directed. |
| 46 | M&L cement concrete pre-polished chequered paver tiles of size of size 305x305x20mm thick with approved colour and approved design set and jointed in neat cement slurry and pointed in white/colour cement to match the shade of the tileincl, complete all as specified and directed. |
| 47 | M&L for 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishescomplete all as specified and directed. |
| 48 | M&L for PCC in 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) 75mm thick as in sub base of floor complete all as specified and directed. |
| 49 | M&L for 100 mm thick concrete (1:2:4) type B-2 using (using 40 mm graded crushed stone aggregate) as path complete all as specified and directed. |
| 50 | M&L for 75 mm thick concrete 1:3:6 mix, type C-2 (using 40 mm graded crushed stone aggregate) as in path complete all as specified and directed. |
| 51 | Cleaning of manhole of size 600mm to 1000mm depth by bailing out water taking out sludge & removing the sludge out side M.D land complete all as specified and directed.Note:-Making a pathway, if required, at any placefor movement of jetting machine and dump tak is inclusive in the rates. Cleaning shall be done by jetting and suctionmachine only. |
| 52 | All as per Item No. 51.00 above, but for manhole of size 1000 to 2000 mm depth complete complete all as specified and directed. |
| 53 | Cleaning of existing sewage line of any diameter by removing silt, sludge, chokages and foreign matter by rodding,flushing etc, and tanking out through existing manhole and burried in sutaible pit dug out for purpose cover with excavated soil ,making good distrurbed surface and ensuring free flow of sewage line,including opening cleaning and refixing of manhole covers complete all as specified and directed. |
| 54 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing)removing the rubbish outside MD land complete all as specified and directed. |
| 55 | M&L non skid ceramic tile area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm thick in floor etc over and including 15mm thick screed bedding in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 56 | S&F glazed ceramic tile 450x350x7mm thick in patch white on vertical surfaces of wall set and jointed in neat cement slurry and pointed in white cement to match over and including 10 mm thick rendering in CM 1:6 even and fair to receive tiles etc complete all as specified and directed. |
| 57 | Note for all items :- If any item gets repeated in this schedule, the lowest rate quoted for those same items by the L-1 bidder shall be considered for payment and decision of Accepting Officer i.e. GE(AF) Baroda in this regard shall be final and binding. |