| 1 | Dismantling of roof sheet (any descriptions) including ridges in roof covering all as specified and directed. |
| 2 | S&F 0.50 mm thick Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall or roof, fixed with self drilling / tapping screws as specified and as directed by Engineer-in-charge |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based plan steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge, fixed with self drilling / tapping screws specified complete. |
| 4 | Demolition of brick work or stone / boulder masonry built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and directed by Engineer-in-Charge |
| 5 | M&L for Brick work with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, using bricks of size 230 mm x 115 mm x 75 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge. |
| 6 | M & L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping, cover slab and the like including weathering, slightly rounded or chamfered angles with & inclnecessary use and waste of form work for fair faces of concrete |
| 7 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, fillets & snap grid etc, complete all as specified. |
| 8 | S&F false ceiling of \"E\" board of size 600 x 600 x 4 mm thick, white prelaminated self embossed, reinforced designer ceiling board / tiles of approved texture at all height laid on and including hot dipped galvanised iron imposed grid with 24 mm wide T-section exposed flanges which shall be powder coated white, the frame work shall comprise of main runner made from 0.33 mm thick GS sheet and of size 24 x 32 x 300 mm and fixed at 1200 mm centre\"s securely fixed to be structural soffits by approved hangers at 1200 mm maximum centres.Hangers of GI wire 4 mm Dia to be fixed by approved Rawl plug level and fasteners and screws etc.The last hanger at the end of each main runner shall not be grater than 450 mm from adjacent wall, Flush fitting of 1200 mm long cross tee (with double stitching) to be interlocked between main runners at 600 mm centre to from 1200 x 600 mm modules cross tee longer than 600 mm to be supported independtly.600 x 600 mm dodules to be formed by fitting 600 mm long cross tee centrally between the 1200 mm cross tee.Tee, perimeter wall angle shall be of 0.45 mm thick GS sheet of size 19 x 19 mm and 300 mm long of white colour all as per manufacture insturction complete all as specified & directed. |
| 9 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries all specified and directed. |
| 10 | M&L for Rendering 15 mm thick in cement and sand mortar 1:4 onbrick work or cement concrete wall surfaces including mixing only water proofing compound as per manufacturers instruction and finishing the surface even and smooth without using extra cementcomplete all as specified.Note:- Waterproofing compound will be measured and paid seperatly. |
| 11 | M&L for Rendering 15 mm thick in cement and sand mortar 1:6 onbrick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cementcomplete all as specified. |
| 12 | Supply only water proofing compound of approved quality complete all as specified and directed by Engineer-in-Charge |
| 13 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer over and including 2 mm thick cement base wall care putty complete all as specified and directed by Engineer-in-charge. |
| 14 | M&L for preparation of new plastered surafce of walls and applying two coats exterior emulsion weather coat paint of make Apex (Asian Paint) / Weather coat (Berger) / Excel Top Guard (Nerolac) over one coat primer including 2 mm thick wall care putty complete all as specified and directed. |
| 15 | M&L for preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, and applying one coat of synthetic enamel paintcomplete all as specified and directed by Engineer-in-Charge |
| 16 | Cutting chases, pinning in and making good to facings of brick/concrete / stone walling where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.;and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth all as specified & directed by Engineer-in-charge. |
| 17 | M&L for filleting in any position and to any shape of section area not exc 25 sq cm in cement sand mortar 1:4 including all mitres, stops etc all as specified & directed by Engineer-in-charge. |
| 18 | M&L for Cleaning the Grit surface of walls of tripple story buildings, by removing dirt, dust, bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., with wire brush,applying and washing the surface with liquid Ammonia Chemical of 5% solution or any other chemical cleaning agent (as approved by Archaeological Survey of India / Engineer-in-charge, of approved brand and manufacturer), with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica, without causing any scratching / damage to the stone grit surface and finally washing the surface with clean water with the help of pressure jet machine, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building / structure, all as per direction of Engineer-in-charge. Note:- Quoted rates shall be deem to include for cost of erection & removing of scaffolding for execution of work up to tripple story building. |
| 19 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell, bell push, light fitting etc for taking credit and making good disturbed surfaces of walls, floors,etc.as directed. |
| 20 | Material & Labour for conceled point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete. |
| 21 | All as per Item No 23 above but for one 5 pin 5 Amp socket outlet point on an independent board. |
| 22 | All as per Item No 23 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch. |
| 23 | All as per Item No 23 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm. |
| 24 | Material & Labour for conceled point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including surface type caping & casing not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete. |
| 25 | All as per Item No 27 above but for one 5 pin 5 Amp socket outlet point on an independent board. |
| 26 | All as per Item No 27 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch. |
| 27 | All as per Item No 27 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm. |
| 28 | Material & Labour for conceled point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through existing concealed PVC conduit.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete. |
| 29 | All as per Item No 31 above but for one 5 pin 5 Amp socket outlet point on an independent board. |
| 30 | All as per Item No 31 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch. |
| 31 | All as per Item No 31 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm. |
| 32 | Material & Labour for concealed point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn existing concealed PVC conduit, including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel sunken type terminal box up to 8 module suitable for modular switch complete.Note:- Modular type cover plate & frame will be measured & paid separately. |
| 33 | All as per Item No 35 above but for one 5 Amp socket outlet point on an independent board. |
| 34 | All as per Item No 35 above but for one 5 Amp socket outlet point on the same board with other switch. |
| 35 | All as item No 35 herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board. |
| 36 | S & F switch piano flush button single pole one way 5 Amp 240 volt complete all as directed. |
| 37 | S & F switch piano flush button single pole one way 15 Amp 240 volt complete all as directed. |
| 38 | S&F socket outlet flush type multipurpose 2 in1, 3 pin 5 and 16 Amp, 230 volts complete as directed. |
| 39 | S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6 Amp, 230 volts complete as directed. |
| 40 | S&F fan regulator electronic,step up socket type,230 volt,125 W and conection complete all as directed. |
| 41 | S&F modular type one way switch, 6 Amp 240 volt in one moduel including connecting complete as specified and directed. |
| 42 | S&F modular type one way switch, 16 Amp 240 volt in one moduel including connecting complete as specified and directed. |
| 43 | S&F modular type 6 Amp 5 pin universal socket in two moduel , 240 volts including connecting complete all as specified and directed. |
| 44 | S&F modular type 6 / 16 Amp 5 pin universal socket suitable in two moduel , 240 volts including connecting complete all as specified and directed. |
| 45 | S&F Modular white cover plate with frame 2 module. |
| 46 | S&F Modular white cover plate with frame 3 module. |
| 47 | S&F Modular white cover plate with frame 4 module. |
| 48 | S&F Modular white cover plate with frame 6 module. |
| 49 | S&F Modular white cover plate with frame 8 module. |
| 50 | Supply & fix modular fan regulator 100 / 100 W, in 2 Module for ceiling fan and connecting as directed. |
| 51 | S&F ceiling rose polycarbonate body surface type three terminal complete as directed. |
| 52 | Supply and fix wall / surface mounting luminaires integrated LED Batten (2 feet) 10 / 12 W, 6500 K, 230V , system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge. |
| 53 | Supply and fix wall / surface mounting luminaires integrated LED Batten (4 feet) 20 W, 6500 K, 230V , system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge. |
| 54 | Supply and fix wall / surface mounting luminaires integrated LED Batten (4 feet) 20 W, warm yellow 3000 / 4000 K, 230V, system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge.. |
| 55 | S&F in repair LED Building security light 35 Watt with high power LED source, system efficency not less than 110 lumen / watt), aluminium die casted housing, built in electronic driver, IP65 and IK 07 with 4 KV inbuilt surge protection including electrical connection with PVC three core copper conductor cable of size 1.5 sqmm, & all necessary fixing accessories, all as specified and directed by Engr-in-charge. |
| 56 | S&F in replacement street light bracket fabricated with mild steel galvanised pipe light grade, 32 mm bore, 1.20 mtr long bend in required shape, fixed on wall with and including mild steel clamp fabricated with flat iron of size 40 x 3 mm and nut of sutable size, duly painted with two coats of synthetic enemal paint over one coat primer complete all as specified and directed. |
| 57 | S&F in repair LED flood light 50 Watt with high power LED source, system efficency not less than 110 lumen / watt), aluminium die casted housing, built in electronic driver, IP65 and IK 07 with 4 KV inbuilt surge protection including electrical connection with PVC three core copper conductor cable of size 1.5 sqmm, & all necessary fixing accessories, all as specified and directed by Engr-in-charge. |
| 58 | Supply and fix in repairs recess type 36 watt LEDllight fittings ofsize 600 mm x 600 mm, made of CRCA powder quoted housing, fully covered by PMMA acrylic Lumio Diffuser, LED Used shall be SMD type, fixed in 15 feet hight false ceiling of any pattern / material by cutting opening of sutable size, including electrical connection all as specified and directed. |
| 59 | Supply and fix in repairs recess type 30 watt LEDllight fittings ofsize 1200 mm x 300 mm, made of CRCA powder quoted housing, fully covered by PMMA acrylic Lumio Diffuser, LED Used shall be SMD type, fixed in 15 feet hight false ceiling of any pattern / material by cutting opening of sutable size, including electrical connection all as specified and directed. |
| 60 | S&F 18 watt LEDlamp 4 pin type, fixed in existing lightfittings complete all as secified and directed. |
| 61 | Supply and fix in repair batten sutaible for 20 watt LED retrofit tube rod 1200 mm (approx) long, having both end bibin holder, internaly prewired, fixed on walls / ceiling / MS downrod suspended including neccessary electric connection from ceiling rose to luminaries complete all as directed. |
| 62 | Supply and fix in repair 20 watt LED tube rod, with ultra bright crystal light, 6000 Kwith high efficency, internal electronic driver, fixed to existing battens complete all as directed. |
| 63 | S&F in repairs integrated LED type Post top lantern with high power 25 / 30 W LED as light source, with built in electronic driver, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution, spun auminium landscape lumainaire, fixed in position and connecting complete all as directed. |
| 64 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring complete.Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 65 | Supply and fix in replacement 1 run single core multistranded copper conductor cable, of size 1.50 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, 1100 volt, for any type electrical connection etc complete |
| 66 | Supply and fix in replacement 1 run single core multistranded copper conductor cable, of size 2.50 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, 1100 volt, for any type electrical connection etc complete |
| 67 | Supply and fix in replacement 1 run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, 1100 volt, for any type electrical connection etc complete. |
| 68 | S&F in repair PVC insulated, PVC sheathed multistranded copper conductor cable 1100 volt, of size 1.5 sqmm 3 core for any type electrical connection etc complete all as specified and as directed. |
| 69 | S&F in repair flat or circular PVC insulated, with inner sheathing of PVC tape and overall PVC sheathed aluminium conductor cable of size 2 core 10 Sqmm 1100 volt grade, fixed for service connection,complete all as specified and as directed. |
| 70 | S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed. |
| 71 | S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed. |
| 72 | S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed. |
| 73 | S&F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, TPN 4 way with 200 Amps rated copper busbar, 415 Volts earth bar IP 43 protection, fixed flush to wall complete all as specified and directed. |
| 74 | S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, \"C\" curve complete all as specified and directed |
| 75 | S&F MCB, single pole & neutral 40 Amp, 240 volts, 10 KA breaking capacity, \"C\" curve complete all as specified and directed. |
| 76 | S&F MCB, triple pole & neutral 63-100 Amp, 415 volts, 10 KA breaking capacity, \"C\" curve complete all as specified and directed. |
| 77 | S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with including one single pole MCB 20 AmpsC curve complete all as per specified and directed . |
| 78 | S&F MCCB 63 -100 Amps 415 volts, 4 pole 16 KA breaking capacity fixed in DB and connecting complete as directed. |
| 79 | Taking down detiorated, rusted out lived and unsv wall mounting fans and supply and fix wall mounted fan 400 mm sweep (white) string controlled oscillating type with all accessories as per manufacturer norms fixed in position and connecting, complete as specified and directed by EIC |
| 80 | S&Finreplacement modular switches 1 way 6 / 10A,1 module, |
| 81 | S&Finreplacement modular switches 1 way 16A,1 module, |
| 82 | S&Finreplacement modular 6 A sockets-2/3 pin combine 2 module, |
| 83 | S&Finreplacement modular 6A/16A sockets-2/3 pin combine 2 module, |
| 84 | S&Finreplacement fan step regulator modular 100/120W, 2 module, |
| 85 | S&Finreplacementmodular white cover plate with frame, 2 module, |
| 86 | S&Finreplacementmodular white cover plate with frame, 3 module, |
| 87 | S&Finreplacementmodular white cover plate with frame, 4 module, |
| 88 | S&Finreplacementmodular white cover plate with frame, 6 module, |
| 89 | Supply and fix in replacement PVC casing and caping, 20 mm wide complete all as specified and as directed |
| 90 | S&F in replacement switch piano flush button single pole one way 5 / 6 Amp 240 volt complete all as directed. |
| 91 | S&F in replacement of switch piano flush button single pole one way 15 / 16 Amp 240 volt complete all as directed. |
| 92 | S&F in replacement of socket outlet flush type multipurpose 2 in1, 3 pin 5 / 6 and 15 / 16 Amp, 230 volts complete as directed. |
| 93 | S&F in replacement of socket outlet flush type multipurpose 2 in1, 5 pin 5 Amp, 230 volts complete as directed. |
| 94 | S&F in replacement of switch socket outlet combination flush type multipurpose 2 in1, 3 pin 5 and 15 Amp, 230 volts complete as directed. |
| 95 | S&F in replacement call bell AC single pole 240 volt ding dong type. |
| 96 | S&F in replacement high range up to 40 mtr, cordless call bell with wireless remote including batteries all as specified and directed. |
| 97 | S&F in replacement angle / batten type holder insulated body with back plate suitable for batten fittings as directed. |
| 98 | S&F in replacement PVC gang box fitted with and including piano type switch 5 A and socket 5 A, 230 Volts complete with pvc gitties and screws all as specified and as directed. |
| 99 | S&F in replacement PVC gang box fitted with and including piano type switch 15 A and socket 15 A, 230 Volts complete with pvc gitties and screws all as specified and as directed. |
| 100 | M&L ofEarthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, burried directly in ground(earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade, watering pipe 20 mm dia GI light grade, GI wire mesh, GI funnel, alternate layer of char coal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation & earth work, earth wire 7.5 mtr connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 complete all as specified and directed . |
| 101 | Taking down water heaters / Geysers of any capacity for overhauling / serviceing / repairing by opening of base plate, descaling of water taknk, heating element, cleaning of entire geyser, checking & tighting of all internal electric connection, replacement of nut bolt etc, reassembling, refixing, re-installation of water heaters / Geysers to their original position, making all necessary water & electric connections and testing complete all as specified and directed.Note :- (i) Labour for assembling of all old/ serviceable and new parts to make the geyser in serviceable conditionshall include in this items.(ii)Spears parts renewed shall be measured and paid spearately as supply only. |
| 102 | Supply only heating element 1.5 KW (ISI marked) suitable for geyser of 25 litres capacity, horizontal or vertical type any make all as specified and directed. |
| 103 | Supply only heating element 2 KW (ISI marked) suitable for geyser of 50 litres capacity, horizontal or vertical type any make all as specified and directed. |
| 104 | Supply only thermostat, minimum 300 mm long, suitable for any make & type of geyser 25 / 50 litres capacity horizontal or vertical type all as specified and directed. |
| 105 | Supply only indicating lamp LED type for geysers of any type make & capacity all as specified and directed . |
| 106 | M&L for preparation of old painted surfaces of geysers of 25 litres capacity of any make and applying one coat synthetic enamel paint of approved shade and rewriting of MES Nos as approved size of letter all as specified and directed. |
| 107 | S&F in repair PVC connection 15 mm dia with 2 Nos brass coupling, nuts from geyser inlet / outlet, 45 cm length suitable for 15 mm bore GI pipe all as specified and directed. |
| 108 | Taking down old detiorated, rusted out lived and unsv ceiling fan, supply & fix new ceiling fan 1200 mm sweep, BLDC copper wound motor, AC single phase, 230 volts, white colour complete with fan blade, down rod, canopy and provn of connection with three core flexible copper wire cable of size 1.50 sqmm from ceiling rose to fan, writing of MES Nos as approved size of letter complete all as specified and directed. |
| 109 | Taking down detiorated, rusted out lived and unsv exhaust fan, supply & fix new exhaust fan metal body 300 mm sweep, 900 RPM, copper bound motar,AC 230 volts, single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi strandedcopper wire of appropriate size includingtesting, writing of MES Nos as approved size of letter complete all as specified and directed. |
| 110 | Taking down detiorated, out lived, rusted and unsv storage type water heater & Supply and fix new storage type water heater 25 ltrs capacity, 5 Star rated, vertical mounting type, made out of CRCA outer body, copper storage tank, heating element, thermostat, thermal cut out, glass wool insulation etc. including making necessary electrical connections with suitable size copper multistranded cable and connecting to water supply complete all as directed by EIC. |
| 111 | S&F in repair 2.5 / 3.15 mfd condenser / capacitor suitable for 230 volts single phase ceiling fan 1200 mm /1400 sweep of any make and type complete all as specified & directed. |
| 112 | Taking down ceiling fans / exhaust fan / wall fan of any size after disconnecting from ceiling rose / connector and carriying out cleaning, servicing / oiling and greasing of fan by using appropriate grade of oil / grease, checking & tighting all electrication connection and replacing defective parts such as bush bearing , split pin, rubber bush, capacitor etc and refixing the same after and making electrication by providing 3 core 1.5 Sqmm size copper conductor flexible cable PVC insulated & PVC sheathed complete all as directed by Engr-in-Charge. NOTE :- Spear parts / component / Painting & rewinding where required will be measured & paid seperatly under respective item of the BOQ. |
| 113 | M&L for rewinding of ceiling fan of any size, AC 230 volts single phase with super enamelled copper winding wire of appropriate / existing gauge / size including packing, insulating material soldering varnishing, assembling and testing including transportation charges to and fro from contractor\"s workshop complete all as specified. |
| 114 | S&F in repair bearing of ceiling fans of size 1200 / 1400mm sweep to suit for different makes of fans of approved quality including necessary greasing complete all as specified & directed. |
| 115 | S&F in repair bushes gun metal suitable for ceiling fans 1200 / 1400mm sweep complete all as directed at site. |
| 116 | M&L for Sub main wiring with two single core PVC insulated cable with 4 sq mm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20mm dia including all conduit and fixing accessaries concealed in wall including cutting chases in wall and making good disturbed surface to match of walls /ceiling complete. (Note-The cost of PVC pipe and accessoried shall be deemed to be included in the quoted rate) |
| 117 | M&L for Sub main wiring with two single core PVC insulated cable with 10 sq mm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 10 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20mm dia including all conduit and fixing accessaries concealed in wall including cutting chases in wall and making good disturbed surface to match of walls /ceiling complete. (Note-The cost of PVC pipe and accessoried shall be deemed to be included in the quoted rate) |
| 118 | M&L for Sub main wiring with four single core PVC insulated cable with 10 sq mm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 10 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20mm dia including all conduit and fixing accessaries concealed in wall including cutting chases in wall and making good disturbed surface to match of walls /ceiling complete. (Note-The cost of PVC pipe and accessoried shall be deemed to be included in the quoted rate) |