| 1 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 Sqm on plan and not exc1.5m in depth in hard dense soil and getting outcomplete all as specified and directed by Engineer in charge |
| 2 | M&Lfor PCC 1:3:6 type C2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete. etc complete all as specified and directed by Engineer in charge |
| 3 | M&lfor RCC M25 (Design mix) using 20mm graded crushed stone aggregates in footing etc. all as specified and directed by Engineer in charge |
| 4 | M&lfor RCC M-25 (Design mix) using 20mm graded crushed stone aggregates in columns etc all as specified and directed by Engineer in charge |
| 5 | M &L for Formwork to sides of concrete foundations, footings etc and similar work, vertical or to batter (Fair finished surfaces of concrete)all as specified and directed by Engineer in charge |
| 6 | M &L for Formwork to sides of columns etc. (Rough finished surfaces of concrete)all as specified and directed by Engineer in charge |
| 7 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed by Engineer in charge |
| 8 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clipsall as specified and directed by Engineer in charge |
| 9 | M &L for Rendering 15mm thick in CM 1:4 on concrete surfaces finished even and smooth without using extra cement all as specified and directed by Engineer in charge |
| 10 | M&L Fortwo coat of Cement base painting on new plastered surfaces of walls including preparation of surfaceall as specified and directed by Engineer in charge |
| 11 | Returning, filling in soil including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified and directed by Engineer in charge |
| 12 | Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed by Engineer in charge |
| 13 | M&L For Mild steel framed work as in gates including pintol hinges, stops, hand made sliding bolts etc with ends of bars shouldered and/or riveted of forged into spikes conforming to Fe 290 Gde E-165 all as specified and directed by Engineer in charge |
| 14 | S&F Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5 mm thick of an colour haveng strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified . |
| 15 | S&F Pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.5 mm thick of an colour haveng strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified . |
| 16 | M &L for plain aluminium sheeting 0.71 mm thick alloy 31000 H4 in ridges ,hip valley, gutter drip and straight flashing complete all as specified and directed by Engineer in charge. |
| 17 | M&L for 20mm thick granite black slab, machine cut, well polished, bedded in 15mm thick in CM 1:4 as columns & like and jointed with grey cement slurry and pointed with white cement(1:2) using marble dust with admixtures of pigments to match the shade of granite stone including cutting and polishing etc. complete all as specified and directed. |
| 18 | Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface, work in soft disintergreted rock complete all as specified. |
| 19 | M & L for PCC 1:4:8 Type D2 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge. |
| 20 | S & F Fe 410-w(Gde E 250)quality A rolled mild steel in roof trusses (framed) trussed, purlins, crane gantries, rails and framing (beam, tee, angle, channel or flat sections) including distance pieaces cleats etc |
| 21 | S&F MS plates plain or chequered square cut or notched forming holes drilled or welded any thickness complete. |
| 22 | M & L for preparation of new steel and iron surfaces of any description over 10 Cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed by Engineer-in-Charge |
| 23 | S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrrugations side lap, fixed with coach screws and washers, in roofs, wall etc. with grade of zinc coating 275 complete all as specified. |
| 24 | S&F 0.63mm thick galvanised, plain mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified. |
| 25 | M & L for preparation of new steel and iron surfaces of any description over 10 Cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer over a coat of moderant solution to remove zinc coating complete all as specified and directed by Engineer-in-Charge |
| 26 | M&L Point wiring (concealed) complete with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through and including PVC heavy dutyconduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed in wall or ceiling etc including 1.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLSH cable as earth continuity wire including suitable size of GI/MS Sunken Boxes alongwithtop cover plate and frame for fixings of modular switches, sockets,bell push andfan regulators etc. completeall as specified and as directed. for the following :- (a) One light, fan, bell point controlled by one switch. |
| 27 | All as per item No. 1 above but with cable size 2.5 sqmm for switch socket outlet point 16 A on independent board including 2.5 sqmm PVC insulated unsheathed copper earth continuity conductor as earth wire and connected to earth dolly complete all as specified and directed. |
| 28 | Supply & fix modular switch 1 way, 5/6 Amps, 1 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Supply & fix modular switch 1 way, 16 Amps, 1 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge. |
| 30 | Supply & fix modular socket, 6/16 Amps, multi pin (ISI marked).complete all as specified and directed by Engr-in-Charge. |
| 31 | S&Fceiling rose surface Bakelite three terminal all as specified and as directed. |
| 32 | S&F outdoor Gate light in aluminum die cast with modern artistic design and white PC diffuser suitable with LED lamp B22. of size 7 watt complete |
| 33 | S&F outdoor intergal fantasy decorative LED Garden bollard with IP protection 65post top lantern suitable for landscape lightingin andincluding 12 watt LEDwith all complete fixing accessories and suitable arrangement as required at site complete all as specified and directed by Engr-in-charge. |
| 34 | M&LPCC work 1:2:4 of size 300mm x 300mm x 300mm below ground level including necessary earth work duly fixed with grounting 04 Nos nut, bolts and washer for fxing of post top lantern in complete all as directed by Engr-in-charge |
| 35 | M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn in new PVC conduitpipe with all aceesories with 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all as specified and directed by Engr-in-Charge |
| 36 | S&F LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 37 | M&L in replacement ofLED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 38 | S&F LED Highbay light 100 watt Next generation, energy saving, environment friendly & robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 39 | S&FMCB distribution board, single door, metal enclosure, SPN, 230 Volts, 2 wayall as specified and directed. |
| 40 | S&FMCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 4 wayall as specified and directed. |
| 41 | S&FMCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 wayall as specified and directed. |
| 42 | S&FMCB, SPN, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve all as specified and directed. |
| 43 | S&FMCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curveall as specified and directed. |
| 44 | S&FPVC insulated, 4 sqmm aluminium stranded conductor sheathed, twin core flat cable incl saddlles & fixing arrangement completeall as directed by Engr- in – charge. |
| 45 | M&L for tubing GI light grade 50 mm bore laid in trenches, ducts, floor for protection of cable,fixed to wall or poles including fixing arrangement all as required and directed by Engineer-in-Charge. |
| 46 | Supply, layingtesting and connecting 25 Sqmm 3.5 Core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade laid in trenches/ducts/wall or through pipe with suitable size of cable glands, crimping type cable lugs complete all as specified and directed by Engr-in-Charge. |
| 47 | Supply, fix and laying of DWC pipe of size 50/38 mm dia (outer dia) with coupler including passing the LT Cables of size 16-70 sqmm through the DWC pipe in trench/duct/on wall (with clamp) for protection of cable all as per direction of Engr-in-Charge. |
| 48 | Febrication, Supply, installation and testing in replacementof LT cubical outdoor panel box (Feeder Pillar) of suitable size or as per site requirement, IP-52 protection class, CPRI approved,floor mounted dust/vermin prooffactory fabricated , made out of MS sheet of thickness 3.15 mmmounted on angle iron legs made out of angle iron of size 40x40x6mmwith front & rear opening with locking arrangement, powder coated, CRCA sheet containing bus bar chamber to accommodate 3 phase & 1 neutral copper busbar covered with R Y B and black PVC heat shrinkable sleeve, size 40 x 10 mm mounted on hygroscopic insulators in horizontal position (stepped manner) in upper part of panel, middle part of distribution panel provided with separate chambers for 01 No. incomming MCCB, 03 Nos for outgoing MCCBs connected to copper busbar of size 20 x 5 mm in bottom partfor cable connection in distribution panel including PCC foundation of panel complete all as required at site and directed by Engr-in-charge to accomodate the following.( DRG to be got approved from the GE before the order is placed ):-(a) MCCB63 Amps 4P, 36 KA, 415 volts with S/C and O/L protection thermal magnetic release adjustable type as incomer - 01 No(a) MCCB 32 Amps 3P, 25 KA, 415 volts with S/C and O/L protection thermal magnetic release adjustable type as O/G - 03 No. (c) Digital Multifunction meter, 3 phase AC 415 volt, flush mounting 96x96 mm accuracy class 1.0, input voltage measurement range 50-520 VAC with suitable CT\"s capable of measuring V, A, F, PF, KW, KVA, kWh/kVAh, old energy, Load hours, CT secondary site selectable 1A/5A, CT/PT site programmable including all parameters - 01 No. (d) Set of LED phase indicator lamp (R,Y,B) - 01 set. Note :- All accessories pre wired with suitable size copper conductor cable and cable gland/lugs etc, proper arrangements for proper ventilation with provn of connecting earthing at both sides of panel board including making necessary arrangements for fixing all as required at site and directed by Engr-in-charge. |
| 49 | M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI Strip of size 25x4 mm as earth lead by means of bolts, nuts washers and check nutsof steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common saltquantity as recommended by the manufacturer oras diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete and all as specified and as directed by Engr-in-charge. |
| 50 | M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.Note : Result of the earthing should beless then 4 ohms if not achieved the new earthing to be carried out without any extra cost. |