| 1 | Taking down existing unserviceable security lights/LED street light /flood lightfittings any type and refixing after repairs complete all as directed by Engr-in- charge. |
| 2 | S & F in repairs unserviceable LED Driver for 60/72 Watts perimeter LED Security light fittings complete all as specified and directed. |
| 3 | S & F in repairs unserviceable LED Driver for 90Watts perimeter LED Security light fittings complete all as specified and directed. |
| 4 | S & F in repairs unserviceable LED Driver for 200 Watts perimeter LED Security light fittings complete all as specified and directed. |
| 5 | S & F in repairs connecting & testing energy efficient LED flood light fittings 120 watts presure diecast aluminium housing and IP 66 ingress protection all as specified & directed. |
| 6 | S & F in repairs connecting & testing new generation energy saving & environmental friendly long life versatile pressure die- cast aluminium IP 66 ingress protection, LED street light fitting 60 watts on existing street light pole complete all as specified & directed. |
| 7 | S & F in repairs connecting & testing new generation energy saving & environmental friendly long life versatile pressure die- cast aluminium IP 66 ingress protection, LED street light fitting 90 watts on existing street light pole complete all as specified & directed. |
| 8 | S & F in repair Robustly designed IP65/IK10 Bollard garden light 10W, Warm White, Innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidence in a landscape environmentlightto be fixed on cement concrete bed in foundations filling and mass concrete and making electrical connection with PVC insulated and sheathed copper cable complete all as specified & directed. |
| 9 | S & F in repairPost top light 35 W , Warm White, IP 66,to be fixed on cement concrete bed in foundations filling and mass concrete and making electrical connection with PVC insulated and sheathed copper cable complete all as specified & directed. |
| 10 | S & F in repairs connecting & testing energy efficient LED flood light fittings 150 watts, pressure diecast aluminium housing and IP 66 complete all as specified & directed. |
| 11 | S & F in repairs connecting & testing energy efficient LED flood light fittings 200 watts, presure diecast aluminium housing and IP 66 ingress protection all as specified & directed. |
| 12 | S & F in repair digital type 24 hrs Astronomical timer switches suitable for operation of street light luminarie with 4 pole Power contacotr of 40 A capacity- 01 No suitable for 3 Phase, 4 wire system incl necessary MCB TPN6-40 A capacity - 01 No as control the system, fixed in the Outdoor type LT junction box madeup of powder coated CRCA sheet steel enclosure 3 mm thick floor mounted of suitable size complete all as specified & directed. |
| 13 | S & F in repair GI bracket for street light fittings fabricated with GI tubing 40 mm dia \"medium grade\" 1.5 m longand bending to angle of 120 degree including mild steel clamp fabricated with mild steelflat iron 50 x 6 mm with nut , bolts & washer suitable for fixing of GI bracket on PCC/ steel poles complete all as specified and directed. |
| 14 | S&F in repair for junction box of size 30X25X15cm ( internal dimension) made out of 2mm thick MS sheet weather proof including one coat of red oxide primer and two coat of synthetic enamel paint and fixing arrangement etc using suitable clamps nuts, bolts etc for accommodating and including the following:-a) Two strip aluminium bus bar of capacity 40 A, including and mounted on epoxy insulators-01 Setb) MCB SP 6 Amps-01 No |
| 15 | M&L in repair for painting of 9.00m steel pole with cross arms and clamp of any length and shape foroverhead line/street light pole with one coat of aluminium paint including preparation of the existing surface including making number in a 15cm dia yellow circle and marking three black & two yellow bends with 10 cm width by fluorescent paint, from coping of pole to 1.5m height on pole including painting of coping with white wash with safety precaution and writing pole No. on pole & all disconnectedelectrical connections are connected and before painting shut down complete all as specified & directed. |
| 16 | M/L in repair for cutting triming and vending tree branches along HT/LT over head lines after arranging electrical shut down, including taking all precautions while working on lines, contractor using own T&P complete all as specified and directed, (For taking shut down to execute the work min one skilled electrician and four mazdoor for 8 hours/day shall be depolyed on the work). |
| 17 | S& F in repair three pole power contactor , ML-3 type, range of AC-1 rating 45 amp , AC-3rating 40 Amp ,Aux.Contacts (2NO+2NC),110V, 220V, 240V and 415V , 50 Hz complete all as directed by Engineering-in-Charge. |
| 18 | S& F in repairthree pole power contactor , ML-4 type, range of AC-1 rating 100 amp , AC-3rating 60 Amp ,Aux.Contacts (2NO+2NC),110V, 220V, 240V and 415V , 50 Hz complete all as directed by Engineering-in-Charge. |
| 19 | S&F in repair aluminium thimbles cables lugs for cables of size 50 sq.mm including necessary crimping with crimping tool complete all as specified and directed |
| 20 | S&F in repair aluminium thimbles cables lugs for cables of size upto 70 sq. mm including necessary crimping with crimping tool complete all as specified and directed |
| 21 | S&Fin repair aluminium thimbles cables lugs for cables of size 95 sq.mm to 120 sq. mm including necessary crimping with crimping tool complete all as specified and directed |
| 22 | Supply and fixing in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type |
| 23 | Supply and fixing in repair cable jointing kit for 1.1 KV grade cable for straight through jointcomplete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 150 sqmm,Indoor/Outdoor type |
| 24 | S&Ffor MCCB ,4-pole, 415 volts, 630 Amps, breaking capacity 36 kA, with adjustable thermal and adjustable magnetic setting including taking outold/ unserviceble MCCB complete all as specified and directed. |
| 25 | S&Ffor MCCB, 4-pole, 415 volts, 400 Amps, breaking capacity 36 kA, with adjustable thermal and adjustable magnetic setting including taking outold/ unserviceble MCCB complete all as specified and directed. |
| 26 | S&F for MCCB, 4 - pole, 415 volts, 250 Amps,breaking capacity 36 kA, with thermal magnetic and adjustable magnetic setting includingtaking down old/ unserviceble MCCB complete all as specified and directed. |
| 27 | S&Ffor MCCB, 4 - pole, 415 volts, 200 Amps,breaking capacity 36 kA, with thermal magnetic and adjustable magnetic setting includingtaking down old/ unserviceble MCCB complete all as specified and directed. |
| 28 | S&Ffor MCCB, 4 - pole, 415 volts, 160 Amps,breaking capacity 36 kA, with thermal magnetic and adjustable magnetic setting includingtaking down old/ unserviceble MCCB complete all as specified and directed. |
| 29 | S&Ffor MCCB , 4 - pole, 415 volts, 100 Amps,breaking capacity 25 kA, with thermal magnetic and adjustable magnetic setting includingtaking down old/ unserviceble MCCB complete all as specified and directed. |
| 30 | Supply and fix OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps complete all as specified and directed. |
| 31 | Supply and fix OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps complete all as specified and directed. |
| 32 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soilincluding bottom surface to required level or slope for layingof cable etc. complete all as specified and directed. |
| 33 | Returning filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft/loose soil complete all as specified and directed. |
| 34 | Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 35 | M&L sand cushioning with dry local ganga sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenchesand consolidated complete all as specified and directed.NOTE :Punned thickness 18 cmonly shall be considered for payment. |
| 36 | Supply and laying dry well burnt locally availablesub class \"B\" bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed. |
| 37 | Boring holes for Insertion of 80/50/40 mm dia GI pipe under PCC Road/ Taxi track/ hard standing not more than 1500mm deep complete all as specified and directed. Note: - (i) Cost of equipments tools & plants, material required for boring shall be deemed to be included in the rates quoted above. (ii) GI Pipe shall be measured and paid separately. |
| 38 | S&F for GI pipe 40 mm bore \"light grade\" ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed.NOTE :Excavation, earth work, cushioning & protection work shall be measured & paid separately. |
| 39 | S&F for GI pipe 50 mm bore \"light grade\" ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed.NOTE :Excavation, earth work, cushioning & protection work shall be measured & paid separately. |
| 40 | S&F for GI pipe 80 mm bore \"light grade\" ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed.NOTE :Excavation, earth work, cushioning & protection work shall be measured & paid separately. |
| 41 | Supplying ,laying, commissioning, jointing& testing 10 Sqmm, 4 core XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cablecomplete all as specified & directed. Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. |
| 42 | Ditto all as per item No. 41 but Cable 4 core 16 Sqmm |
| 43 | Ditto all as per item No. 41 but Cable 3.5 core 25 Sqmm |
| 44 | Ditto all as per item No. 41but Cable 3.5 core 35 Sqmm |
| 45 | Ditto all as per item No. 41but Cable 3.5 core 50 Sqmm |
| 46 | Ditto all as per item No. 41butCable 3.5 core 70 Sqmm |
| 47 | Ditto all as per item No. 41butCable 3.5 core 95 Sqmm |
| 48 | Ditto all as per item No. 41 but Cable 3.5 core 185 Sqmm |
| 49 | Dismantling / disconnecting existing unserviceable ACSR conductor on overhead lines on LT/HT poles, of any size complete all as specified and directed. |
| 50 | Dismantling insulators any type, any size complete all as specified and directed. |
| 51 | Dismantling stay assembly complete (demolition of concrete, etc. and excavation measured separately). |
| 52 | M&L for ACSR conductor including jointing with and including aluminiumbinding wire 14 SWG dia and stretching completeall as specified and directed.Note: For payment purpose, weight of conductor only shall be considered. |
| 53 | S&F shackle type porcelin viterous white brown or green insulator of working pressure of 1100V size 100mm height and 115mm dia incl GI steel straps of section 38x5mm size 20mm dia bolt nut and washers complete all as specified and directed. Make - Southern insulator/Reychem/Birla 3M/Jaipuria |
| 54 | S & F pin type insulator, porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut,100 mm height and 65 mm dia suitable for working pressure 1100 volts grade complete all as specified and directed.Make - Southern insulator/Reychem/Birla 3M/Jaipuria |
| 55 | S&F in repair stay assembly consisting of galvanisedstay strand 7/2.24mm stay bow of 14 mm dia, stay rod 16 mm dia 180 cm long with loop insulators stayplate 230 mm x 230 mm x 6 mm with plain cement concrete foundation 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate ) as shown in SSR Pt-I, electrical plate No- 1, complete with stay clamps, bolts and nuts all as specifiedand directed byEngineer -in - Chargeincluding comprising of the following :-(a) Excavationand earth work for stay foundation in soft/loose soil,disposal of surplussoiltoa distance not exceeding 50 metres &depositingwhere directed at a level not exceeding 1.5 mtr from the starting point as directed.(b) PCC1:3:6, typeC-2 ( using 40 mm graded crushedstoneaggregate) as in embedding blocks all as specified. |
| 56 | S&F in repair of service cable 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular all as required or directed. |
| 57 | S&F in repairservice cable 16 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular all as required or directed. |
| 58 | Dismantling of steel poles/struts of any size complete all as specified and directed. |
| 59 | S&F steel tubular pole410-SP31 (9.0m long pole) complete with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete including dismantling of exsiting pole all as specified including consisting of following works:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.57 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed.(b) M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) in foundation 900mmx600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto GL complete all as specified and directed.(c) M&L for providing PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 500mm high and 450mm dia complete all as specified and directed. |
| 60 | Contd/...(d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block.(e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed.NOTE : Manufacture\"s test certificate of pole will be produced before execution work. |
| 61 | S&F in repair of wall mounted Distribution Board factory made of size 600mm x 450mm x 150mm made of MS sheet 2.0 mm thick CRCA sheet with powder coated paint ,dust and vermin proof with front openable door and locking arrangement consisting of following accessories:a) MCCB 100A, 4 pole 25kA fixed magnetic and thermal release - 01 No(incoming)b) 3 phase and neutral bus bar copper LT 440V, 200 A(outgoing)c) Phase indication lamp LED type R,Y,B |
| 62 | Supply, installation ,testing & commisioning of LT outdoor type kiosk pedestal panel , factory made, cubical, powder coated with fabricated 3.15mm thick with angle iron/ flat iron frame work, bus bar chamber, front openable hinge door with locking arrangement and common openable hinged door from the rear side, floor mounting type, IP-65 protection and as per IS and suitable size as given by manufaturing, comprising of following:- (a) INCOMING:-(i) Rectangular Aluminum strip of size 60 x 10 mm fixed on insulated mounting arrangement - 04 nos(ii) MCCB FP 400 Amps, 36 KA,with Microprocessor releaseadjustable type - 01 No (iii) Digital multifunction meter -01 No Make L&T(b) OUTGOING:-(i) MCCB 250 Amps FP 36 kA - 02 Nos (ii) MCCB 160 Amps TP 36 kA - 01 No |
| 63 | S&F in repair ,installation ,testing & commisioning of LT outdoor type kiosk pedestal panel , factory made, cubical, powder coated with fabricated 3.15mm thick skeleton with angle iron/ flat iron frame work, bus bar chamber, front openable hinge door with locking arrangement and common openable hinged door from the rear side, floor mounting type, IP-65 protection and as per IS, comprising of following:- (a) INCOMING:-(i) Rectangular Copper strip of size 50 x 5 mm fixed on insulated mounting arrangement - 04 nos(ii) MCCB FP 200 Amps, 50 kA, adjustable type - 01 No (iii) Ammeter analog type 0 to 500 A - 01 No(iv) Voltmeter analog type 0-500 V - 01 no(v) Three way selector switch - 01 No(vi) Phase indicating light LED type - 01 Set(b) OUTGOING:-(i) MCCB 160 Amps FP 36 kA - 02 Nos (ii) MCCB 63 Amps TP 36 kA - 01 No |
| 64 | M&L Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of galvanised iron 25x4mm stripall as shown in Plate No. 2and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregate ) chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-castRCC cover 1:2:4 , type B-1 and connected to earth test point including testing & taking down of old/ ineffective earthing complete all as specified and directed.(Note:-The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 meter beyond the earth plates electrode) |