| 1 | Part - I RECONSTRUCTION/IMPROVEMENT OF MONSOON DRAINS |
| 2 | Demolition of stones or brick masonry or block walling, built in cement mortar including all quoins, arches etc., but excluding ashlar facing, dressed stone work etc.complete including removal of debris to a distance exc 1.5 km but n.exc 2 Km, all as specified and as directed. |
| 3 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing the debris off all as specified and directed. |
| 4 | M&L for Demolition Reinforced Cement concrete concrete cover slab (other than ground floors), and similar suspended work all as specified and directed. |
| 5 | Taking down plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc etc complete all as specified and directed. |
| 6 | M&L for plain cement concrete 1:4:8 type D2 (Using 40 mm graded granite stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed. |
| 7 | M&L for brick work with old size fly ash bricks straight or curved on plan exc.6m mean radius built in cement mortar1:6 complete all as specified and as directed |
| 8 | M&L for brick work with old size fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6 complete all as specified and directed. |
| 9 | M&L for rendering 15mm thick on fair faces of brick work/ concrete surfaces in cement mortar 1:6 and finished even and fair complete all as specified and as directed. |
| 10 | Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paintfinished smooth with sand paper complete all as specified and directed. |
| 11 | M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) assurface chennels including throating including use and waste of form work and finishing theexposed faces of concrete even and smooth without using extra cement complete all as specified and as directed |
| 12 | Providing PCC 1:3:6, type C1 (using 20mm graded stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed. |
| 13 | M&L for extra for forming fair finished channel n.exc 55cm girth in cement concrete using extra cement including forms moulds/ mitred/ stopped end, etc., complete all as specified and as directed |
| 14 | M&L for Precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded granite/ trap stone aggregate) as in cover slabs (for man holes, etc.,) set in cement mortar 1:6ncluding form work complete all as specified and as directed. Note : Reinforcement steel bars shall be measured and paid separately |
| 15 | M & L for mild steel TMT bars of 08 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 16 | M&L for 100 mm thick cement concrete type D2 1:4:8 using 40 mm graded stone aggregate asin sub base complete all as specified and as directed . |
| 17 | M&L for 100 mm thick cement concrete type B2 1:2:4 using 40 mm graded stone aggregate asin flooring and finishing cement concrete surface even and smooth without using extra cementcomplete all as specified and directed |
| 18 | M&L for 450mm dia reinforced concrete pipes, class NP2, laidand jointed complete with collars all as specified and directed. |
| 19 | Surface excavation not exc 30 cm deep and ave 30 cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 20 | Cleaning of drains of any description and size not exc 1 Mtr on Width and not exc 1 Mtr depth including lifting up and removing sludge, sand, accumulated solid sludge and other foreign materials and wash down with water for smooth functioing of drainage complete all as specified and as directed.Note : Sludge,sandand other material obtained from cleaning shall be removed from site and burried into the ground where directed. |
| 21 | PART II -Provision of window grill in office of D(T) Hangers at MTTI |
| 22 | S &F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 23 | M&L Preparation of new steel surfaces and applying two caot of synthetic enamel paint over a coat red oxide primer complete |
| 24 | Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 Exe half brick and not Exvc oner brick Depth of embedded portion of holdfast or lugs measured from the face of the jamb into the wall complete |