| 1 | Boring holes 5m deep in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50m (dia of pile 300mm) |
| 2 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation etc and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning Filling in, including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 4 | Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point complete all as specified and directed. |
| 5 | M&L for sand filling under floors or in foundations including watering and consolidation. |
| 6 | M&L for hard core of gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick with broken bricks, watered and rammed to a true surface complete all as specified and directed. |
| 7 | M& L for ATT Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface of flooring complete all as specified and directed |
| 8 | M&L for ATT Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed. |
| 9 | M&LPCC1:4:8type-D2 (using 40mm graded stone aggregate) asin foundations, filling and mass concrete.sub base as in floors complete all as specified and directed. |
| 10 | M&L Brick work using old size sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 11 | M&L Brick work using old size sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed. |
| 12 | M&L reinforced cement concrete (M-25 Design mix) (using 20 mm graded stone aggregate) in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete all as specified and directed. |
| 13 | M&L reinforced cement concrete(M-25 Design mix) (using 20mm graded stone aggregate) as in columns, pillars, posts, struts etc complete. |
| 14 | M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete. |
| 15 | M&L RCC 1:2:4 type B1(using 20mm graded stone aggregate) as in beams, cantilevers, bressmummers, lintels over 1.5 m span, seismic bands etc complete all as specified and directed. |
| 16 | M&L Form work to soffits of suspendedslabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for flat rough finished surfaces of concrete. |
| 17 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete. |
| 18 | M&L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished , square, rectangular or polygonal surfaces of concrete complete all as specified and directed. |
| 19 | Form work to edges of concrete flats, treads, breaks in floors window cills, concrete railing, openings in concrete walls, floor and roofs n exc 20 cm wide and side of RCC/PCC bands in walls, horizontal or sloping and similar work complete all as specified. |
| 20 | S&F Mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopinbg for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 21 | Same as item No 20 above but 6mm dia and over upto and including 10 mm dia in stirrups, spacers and binders. |
| 22 | M & L for 20 - 25 mm thick machine cut Kota stone slab as in flooring , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including Screed bed or bedding layer of Cement Mortar (1:6), 20 mm thick for laying floor finishes,necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed. Note: (size of the stone slab not less than 22\"x22\") |
| 23 | M&L Machine cut Kota stone slab flooring 20-25mm thick as on skirting, laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete over and including 15 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 24 | M&L15 mm thick rendering in two layers (10mm & 5mm ) on fair faces of brick / concrete surfaces in cm (1:4) with WPC (WPC measured & paid separetely) finished even and smooth (Without using extra cement ) complete all as specified and directed. |
| 25 | M&L 15 mm thick rendering on fair faces of brick /concrete surfaces in cm (1:6), finished even and smooth (Without using extra cement ) complete all as specified and directed. |
| 26 | M&L rendering 10mmthick in CM 1:4 on concrete surfacves/ chajja/ ceiling, etc finished even and smooth without using extra cement complete all as specified and directed. |
| 27 | Supply only water proofing compound (liquid), ISI marked. |
| 28 | M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in bed blocks for fixing hold fasts including necessary form works complete all as specified and directed. |
| 29 | S&F Mild steel works as in hold fasts, clamps, plain angle cleats for securing purlins to wood trusses or rafters, cooler stands and similar small articles conforming to Fe 410-0 or Fe 310-0 |
| 30 | S&F steel windows with side hung shutter incl box type butt hinges with bow handle,steel peg stay, tower bolts (each shutter having two tower bolts 100mm long ) complete with glazing bars dovetailed or welded complete all as specified and directed. |
| 31 | Same as item No 30 above but without glazing bars |
| 32 | S&FGI wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staple complete all as specified. |
| 33 | S& F 5 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane complete all as specified and directed. |
| 34 | Preparation of new plastered surfaces of wall and applying two coats of cement base paintover a coat of cement primer complete all as specified and directed. |
| 35 | M&L for Prepration of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. |
| 36 | M&L for prepration of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 37 | Supplied and fixing steel rolling shutter ,with ball bearing as specified including top cover anchoring rod ,hasp and staple and one shop coat of primer, erected in position as indicated,completewith thickness of lath in 1.25 mm asbut gear operated type withbevelgear boxand crank handle and safety lever lock mild steel with 4 lever for rolling shutter as specified. |
| 38 | M& LforPre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 39 | S & F for rolled mild steel structural steel work as in trusses, columns in (tubular/rectangular/square) including purlins, rafter, special shaped washer etc. completeusing any dia of MS pipe medium grade/angle or using ERW or induction butt welded tubes/angles conforming to I. S.1161-1979 gradeSt.-240 complete all as specified and directed. |
| 40 | S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165. |
| 41 | M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in floor/plinth protection laid in suitable panels finished even and fair all as spd .6mm Joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 gde and three part of sand ( all by weight) complete all as specified and directed. |
| 42 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. |
| 43 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 44 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors/ trenches complete all as specified and directed. |
| 45 | S&F clamp made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110mm PVC pipe complete all as specified and directed. |
| 46 | M/L PVC(SWR) bend of110mm dia of any radius etc complete all as specified and directed |
| 47 | M/L PVC(SWR) Tee of110mm dia etc complete all as specified and directed |
| 48 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit \"medium grade\" ISI marked including all conduit accessories for concealed wiring for one light/fan/bell/buzzer / exhaust fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting& making good disturbed surface & applying finishes to match existing surfacecomplete all as specified and directed. |
| 49 | Same as item No. 48 here-in-before but one 3 pin, 5 Amp socket out let on independent board complete all as specified and directed. |
| 50 | Same as item No. 48here-in before but 3 pin ,5 Amp socket out let on the same board with other switchcomplete all as specified and directed. |
| 51 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 4.0Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit \"medium grade\" ISI marked including all conduit accessories for concealed wiring including concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 4 Sqmm FR type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting& making good disturbed surface & applying finishes to match existing surfacecomplete all as specified and directed. |
| 52 | S & F for switch piano, flush type, 5 amps, single pole,one way, 230 voltcomplete all as specified and directed. |
| 53 | S & Ffor2/3 pin, 5 Amp/ 6 Amp, socket outlet, flush type, 2 in 1complete all as specified and directed. |
| 54 | S&F switch socket combination 2 in 1, 6 pin16Amps multipurpose type 240 volts complete all as specified and directed. |
| 55 | S&F ceiling rose single phase, PVC poly carbonate, insulated bodythree terminals ISI marked complete all as specified and directed. |
| 56 | S& F for sheet metal enclousre factory made for MCB DB\"s SPN, 8 way, double door, 240 Volts with 200 Amp rated bus bars including taking down existing unserviceable MCB DB complete all as specified and directed. |
| 57 | S&F MCB SP 240 Volt 6 TO 40Amp ISI marked conforming to \"C\" curve, breaking capacity 10 KA complete all as specified and directed. |
| 58 | S&F MCB SPN40-63 amp 30mA for earth leakage. Over load and short circuit protection ISI marked complete all as specified and directed. |
| 59 | Supply & fixing fan regulator, modular type, socket type compatible with BLDC fans, single phase complete all as specified and directed. |
| 60 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box typeExtruded aluminum housing (enhances safety) with high quality polycarbonate diffuser , 4 ft,2000lm,voltage protection range 140V -270 V,NW 4000K ,connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 61 | Supply, fixing and testing of ceiling fan 1200 mm sweep, heavy duty, single phase, AC, 230 Volts, 50Hz, BEE 5 star rating, ISI marked complete with down rod, canopy, blades, BLDC motor (without remote, electronics fan regulator etc ) with 5 year on site warrantyand connecting up complete including complete connection from ceiling rose to fan including writing of MES Number with synthetic enamel paint with depositing old fan to MES store for further BER complete all as specified and as directed. |
| 62 | S&F in replacement ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends 150 mm diaconforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) inany length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, excavation of pipe line,connections etc complete all as specified and directed.Note:Excavation and earth work shall be measured and paid sperately under relevant items of this schedule. |
| 63 | Cutting existing CI / MS / DI pipe line for insertion of new tees, collars for branch connections of 150 mm dia pipe complete all as specified and directed.Note: CI /DI specials, Joints and Earth work shall be measured and paid sperately under relevant items of this schedule. |
| 64 | S&F in replacement DI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single \"Y\" branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed. |
| 65 | Supply and fix in replacement 150 mm dia Sluice valves of class PN 1.6 Complete all as specified and directed. |
| 66 | S&F in replacement connecting and testing of Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water mains complete all as specified and directed. |
| 67 | Supply, fixing, laying and jointing GI tubing medium grade with one socket both end threaded in any length including cutting threading for connection in new or old position and all type of GI new fittings for laid in trenches/wall/ceiling/ floor/ all as specified and directed of following sizes:- |
| 68 | 80 mm bore. |
| 69 | 50 mm bore. |
| 70 | 40 mm bore. |
| 71 | 25 mm bore. |
| 72 | 20 mm bore. |
| 73 | S&F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe of following sizes : - |
| 74 | 50 mm bore. |
| 75 | 40 mm bore. |
| 76 | 25mm bore. |
| 77 | 20 mm bore. |
| 78 | M&L for Construction of new PCC solid Masonry valve chamber of size 900 X 900 X 900 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets around over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. |
| 79 | Cutting the existing road of any kindstraight by manual, depth and width not less than 30 cm for pipes up to 150 mm dia and 60 cm for pipes from 150 mm to 300 mm dia and 75 cm for pipes above 300 mm dia and filling back with excavated soil up to 75 %road portion and 25 % shall be make good with plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed. |
| 80 | Core cutting / drillingof Bldg Roof / Wall for passing of GI Pipe up to 40 mm dia including necessary machineries complete all as specified and directed. |
| 81 | Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth andgetting out inhard standing/pcc/road/footpathfor laying of pipe line complete all as specified and directed including removing of debries from site . |
| 82 | M&L PCC 1:3:6 type C1 using 20 mm graded stone aggregate for coping & plastering of valve chamber in cement mortar 1:4/ supportring of pipe/ for hard standing including shuttring workas required complete all as specified and directed. |