| 1 | Checking and attending electrical complaints for continuous electric supply system like No light / Short circuit / non working fittings / fitures and replacement of unserviceable spares for all electrical fixtures such asswitch ,socket ,fan regulator, MCB, holders , tube light , bulk head , ceiling fitting etc including carrying out theminor repair likefixing screws, tightening of loose wires,replacement of small pieces of electric wire upto 1.00 mtr length and maintenance work completeall as directed by Engr-in-charge, under AOR of AGE E/M-II South. Note:- Fixtures Such as switch, sockets, fan regulator , MCB, holder tubelight/ fancy / wall / ceiling / security light fittingshall be measured and paid under respective item here in below. |
| 2 | Checking and attending electrical ceiling fan/ exhaust fancomplaint including replacement of unserviceable ceiling fan condensor of any capacitycomplete on all working days all as directed by Engr-in-charge, under AOR of AGE E/M-II South. Note :- Fan condensor shallbe measured and paidunder respective item) |
| 3 | Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable switch, socket, plug top , burnt copper wire connections wherever required upto 1 mtr length complete all as specified and directed by Engineer-in-Charge. under AOR of AGE E/M-II South.Note for item No 1, 2 & 3(a) fixtures / fittings shall be paid under relevant item againstsupply only.(b) Contractors are advised to visit the sites before quoting their rates.(c) Materials for repair works as directed by Engineer-in-Charge shall be supplied by the contractor and adequate stock shall be held all the time by contractor (d) Contractor shall be penalised @ Rs. 200/- per complaint per day, if he fails to attend the complaint within 12 hours.(e) All ser numbered complaint docket will be provided by contractor and amount of docket included in quoted rate. (f)All T&P and safety gears will be provided by the contractor (g) Contractor will deploy a computer operator who will register the complaints from the departmental computer areawise on all working day and settled all complaints after completion of work. (h) Any nature of electrical complaints the whole sole responsibility for rectification liaise with contractor. (j) Any nautre of work involve in one qtr will be counted as a single complaint at a time. |
| 4 | Supply only switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer-in-Charge |
| 5 | Supply only switch piano6amp SP two way, complete all as sspecified and directed by Engineer-in-Charge |
| 6 | Supply only socket piano outlet6 Amp flush button type complete all as sspecified and directed by Engineer-in-Charge |
| 7 | Supply only bell push single pole 6 Amps complete all as sspecified and directed by Engineer-in-Charge |
| 8 | Supply only switch piano flushbutton type single pole 15/16 Amps. complete all as sspecified and directed by Engineer-in-Charge |
| 9 | Supply only socket piano outlet, 2 in 1, 3 pin 6 and 15/16 Amp single pole complete all as sspecified and directed by Engineer-in-Charge |
| 10 | Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete all as sspecified and directed by Engineer-in-Charge |
| 11 | Taking down unsv ceiling fan / exhaust fan of any type / makeform site and deposite to AGE E/M-II yard for repair complete all as directed at site. |
| 12 | Supply onlyElectric bell Ding-Dong AC 230 Volt etc complete all as specified and directed by Engineer-in-Charge |
| 13 | Supply onlyPVC insulated body, (anglual/ Straight ) holderwith back plate complete all as specified and directed by Engineer-in-Charge |
| 14 | Supply only industrial metal clad plug top, 3 pin,20 ampcomplete all as specified and directed by Engineer-in-Charge |
| 15 | Supply only industrial metal clad socket 3 pin20 ampcomplete all as specified and directed by Engineer-in-Charge |
| 16 | Supply only plug top 16 Amps3 pin 230- volts complete all as sspecified and directed by Engineer-in-Charge |
| 17 | Supply only hole fastner madeup of MS 4\" long with complete nut boltcomplete all as specified and directed by Engineer-in-Charge |
| 18 | Supply only heating element of 1.5/2 KW any type with nut bolt washer complete as per site requirement all as specified and directed by Engineer-in-Charge. |
| 19 | Supply onlythermostat for 6\"/11\" suitable forgeysers of capacity 25/50 Ltrscomplete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply only PVC connection pipe of 15 mm suitable for hot/cold water, 60 cm long with brass nuts and rubber washerscomplete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply only replacement copper cable flexible 2.5 Sqmm 3 corePVC insulated complete all as sspecified and directed by Engineer-in-Charge. |
| 22 | Supply onlyLED Tube rod1x20 Watt , with opal diffuser, environmental friendly, energy efficientsuitable for MS batten with retrofit T8 polycarbonate one end connection, complete with all accessories and fixing material all as specified and directed by Engr-in-Charge. |
| 23 | Supply only decorative LED Tube light fitting incl LED rod1x20 Watt surface mounting, intigrated with opal diffuser complete with all accessories as specified and directed. |
| 24 | Supply only decorative LED Tube light fitting incl LED rod1x20 Watt surface mounting, intigrated warm white with opal diffuser complete with all accessories as specified and directed. |
| 25 | Supply only decorative LED Tube light fitting incl LED rod1x20 Watt , with opal diffuser, environmental friendly, energy efficientsuitable for MS batten with retrofit T8 polycarbonate single end connection, complete with all accessories and fixing material all as specified and directed by Engr-in-Charge. |
| 26 | Supply onlyLED tube light fitting 9/10 watt surfacemounted,with extruded polycarbonate , integrated lamp & driver, with opal diffuser and decorative end plates.complete with acessories all as specified and directed by Engr-in-Charge. |
| 27 | Supplying and fixing LED bulk head light fitting wall mounted with inbuilt edge lit LED9/10 watt, complete with all acessories all as specified and directed by Engr-in-Charge. |
| 28 | Supply and fixin replacement of decorative wall light fixture made up of polycarbonate with holder B22 suitable for retrofit lamp completeall accessories for fixing of fitting on wall all as specified and directed by Engr-in-Charge. |
| 29 | Hanging only ceiling fan/ exhaust fan including connection etc complete all as specified and directed. |
| 30 | Supply only 15 W LED Bulbs, high energy efficiency LED luminariesto be fitted on existing holders 240 V,50 Hz, complete all as specified and directed by Engineer-in-Charge |
| 31 | Supply and fix 12W emergency Bulb/rechargeable with 4hrs back up, cool day light complete all as specified and directed. |
| 32 | Supply only MCB SPN 40 to 63Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer-in-Charge |
| 33 | Supply only MCB SP 6 to 32Amps 240 volts 10 KA 50 HZ \"C\" curvecomplete all as specified and directed by Engineer-in-Charge |
| 34 | Supply onlysingle pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 32 Ampcomplete all as specified and directed by Engineer-in-Charge |
| 35 | Supply only hylum sheets 3mm thick including cutting for mounting of switches / sockets /of sizes 4\"x4\" complete all as specified and directed. |
| 36 | Supply only hylum sheets 3mm thick including cutting for mounting of switches / sockets /of sizes 8\"x10\" complete all as specified and directed. |
| 37 | Supply only hylum sheets 3mm thick including cutting for mounting of switches / sockets /of sizes 10\"x12\" complete all as specified and directed |
| 38 | Supply only replacement of capacitor 2.5 Mfd,240 Vcomplete all as sspecified and directed by Engineer-in-Charge |
| 39 | Supply only replacement copper cable single core PVC insulated of size 1.5mm complete all as specified and directed by Engineer-in-Charge |
| 40 | Supply only replacement copper cable single core PVC insulated of size 2.5mm complete all as specified and directed by Engineer-in-Charge |
| 41 | Supply and fixing in repairLED security light fitting 1x45 Watt luminaries withdie cast aluminium housing comprising epoxy powder coated enclosed with glass cover in frame with high power LED white lamp type of capacity 45 wattcomplete all as specified and directed. |
| 42 | All as item No 41.00 above but capacity 25 watt complete all as specified and directed |
| 43 | Supply only switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal complete all as specified and directed by Engr-in- Charge |
| 44 | Supply & fixing in replacement of modular switch one way 06 Amps,1 module,240 volts complete all as specified & directed. |
| 45 | Supply & fixing in replacement ofmodular socket one way 6 Amps,2/3 pin combined ,2 module,240 volts complete all as specified & directed. |
| 46 | Supply & fixing in replacement of modular switch one way16 Amps,1 module, 240 volts complete all as specified & directed. |
| 47 | Supply & fixing in replacement ofmodular socket one way 6/16 Amps,2/3 pin combined ,2 module,240 volts complete all as specified & directed. |
| 48 | Supply & fixing in replacement ofmodular Bell Push 6A,(1 or 2 module as per site), 240 volts complete all as specified & directed. |
| 49 | Supply & fixing in replacement ofmodular fan step regulator2 Module complete all as specified & directed. |
| 50 | Supply & fixing in replacement ofmodular switch two way 06 Amps,1 module,240 volts complete all as specified & directed. |
| 51 | Supply & fixing in replacement ofmodular white cover plate with frame,3 module for6 / 16 Amps Switches And Sockets ,240 volts complete all as specified & directed. |
| 52 | Supply & fixing in replacement ofmodular white cover plate with frame,4 module ,240 volts complete all as specified & directed. |
| 53 | Supply & fixing in replacement ofmodular white cover plate with frame,6 module,240 volts complete all as specified & directed. |
| 54 | Supply & fixing in replacement ofmodular white cover plate with frame,8 module,240 volts complete all as specified & directed. |
| 55 | Supply & fixing in replacement ofmodular white cover plate with frame,12 or more Module Required at site module,240 volts complete all as specified & directed. |
| 56 | Supply and fix Bollard/garden light of 10W IP66 along with ploe withmin height 60CM including all conncetion wire,switch,socket etc complete all as specified and directed. |
| 57 | Supplying and fixing 10 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular complete all as specified and directed |
| 58 | Supply, install, testing and commissioning single phase two wire, single source direct connected pre paid key pad based BIS marked IS 15884 digital energy meter, 240 volts, 10 to 60 Amps, accuracy class I, including parallel Customer Interface Unit (CIU) fixed on suitable size PVC/wooden board, soft token transfer device (STTD) &fixed on suitable size PVC board at consumer house with facility of meter to generate ABC(Authenticated builling code) for monthly energy usage bill generation, having LCD type display, calibration LED numeric key pad for token entry with RS 232 communication port, credit status indication, push button for scroll & having features for load disconnection in case the credit limit becomes zero or increase of load more than permissible limit, reconnection & disconnection of load, buzzer at CIU to give alarm for of low credit and overloading. Data download port for last 25 tamper events and load survey with all standard anti tamper features including sealing facility complete with and including polycarbonate transperent box of suitable size for housing the meter including taking down old unserviceable meter and deposited to AGE E/M-II store yard complete all as specified and directed. |
| 59 | Supply, install, testing and commissioning three phase four wire, single source direct connected pre paid key pad based BIS marked IS 15884 digital energy meter, 3x240 volts, 10 to 60 Amps, accuracy class I, including parallel Customer Interface Unit (CIU), fixed on suitable size PVC/wooden board, soft token transfer device (STTD) & fixed on suitable size PVC board at consumer house with facility of meter to generate ABC(Authenticated builling code) for monthly energy usage bill generation, having LCD type display, calibration LED numeric key pad for token entry with RS 232 communication port, credit status indication, push button for scroll & having features for load disconnection for the credit limit becomes zero or increase of load more than permissible limit, reconnection & disconnection of load, buzzer at CIU to give alarm of low credit and overloading. Data download port for last 25 tamper events and load survey with all standard anti tamper features including sealing facility complete with and including polycarbonate transperent box of suitable size for housing the meterincluding taking down old unserviceable meter and deposited to AGE E/M-II store yard complete all as specified and directed. |
| 60 | Supply and fix CIU(Customer Interface Unit) suitable for single Phase/ three Phase prepaid Meterincluding taking down old unserviceable meter and deposited to AGE E/M-II store yard complete all as specified and directed. |
| 61 | Supply onlysofttoken transfer Device (STTD ) including taking down old unserviceable meter and deposited to AGE E/M-II store yard complete all as specified and directed. |
| 62 | Material and labour for sub main wiring with two pair (four core) insulated transparent 0.5Sqmm wire 1.1 KV telephone wire in and including PVCmedium grade conduit 15mm dia fixed on wall /roof /floor medium grade with suitable clamps & fixing screws from meter to CIU unit. Complete set all as specified an directed. |