| 1 | Supply, installtion,testing commisioning of LT panel, CPRI approved out door type of size not less than 1300x500x1900mm, platform mounted, totally enclosed, dust and vermin proof, openablefrom both- front and rear side, made out of 3.15 mm thick CRCA sheetincluding inner chambers/partitions to mount the following electrical accessories withangle iron 75x75x6mmframe work, having front & rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The entire panel including cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at siteincluding dismantling and taking down of old unsv panel complete allas specified & directed :- |
| 2 | BUS BAR - Aluminium bus bar system of capacity 600 amp four pole duly colour coded.INCOMER - MCCB, 4 poleof capacity 400 amps with breaking capacity of 36 KA . - 01 No.Outgoing - (a) MCCB, 4 poleof capacity 250 amps with breaking capacity of 25 KA . - 01 No. (b)MCCB, 4 poleof capacity 160 amps with breaking capacity of 25 KA . - 02 No.(c)MCB, 4 poleof capacity 32 amps with breaking capacity of 10 KA . - 02 No. (d)MCB, 4 poleof capacity 63 amps with breaking capacityof 10 KA . - 01 No.(e)MCB, 4 poleof capacity 6 amps with breaking capacityof 10 KA . - 01 No.(f) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01(g) Digital multimeter - 01 No(h) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three |
| 3 | Supply, installtion,testing commisioning of LT panel, CPRI approved out door type ofsize not less than 1300x500x1900mm,platform mounted, totally enclosed, dust and vermin proof, openablefrom both front and rear side, made out of 3.15 mm thick CRCA sheetincluding inner chambers/partitions to mount the following electrical accessories with angle iron 75x75x6mmframe work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unserviceablepanel complete allas specified & directed :-\"BUS BAR - Aluminium bus bar system of capacity 600 amp four pole duly colour coded.INCOMER - MCCB, 4 poleof capacity 400 amps with breaking capacity of 36 KA . - 01 No.Outgoing - (a) MCCB, 4 poleof capacity 250 amps with breaking capacity of 25 KA . - 01 No. Contd... |
| 4 | (b)MCCB, 4 poleof capacity 160 amps with breaking capacity of 25 KA . - 02 No.(c)MCCB, 4 poleof capacity 100 amps with breaking capacityof 25 KA . - 01 No.(d)MCCB, 4 poleof capacity 63 amps with breaking capacity of 25 KA . - 01 No.(e)MCB, 4 poleof capacity 32 amps with breaking capacity of 10 KA . - 02 No.(f)MCB, 4 poleof capacity 63 amps with breaking capacity of 10 KA . - 01 No.(g)MCB, 4 poleof capacity 6 amps with breaking capacity of 10 KA . - 01 No.(h) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loccoordinates. Nos-01(j) Digital multimeter - 01 No(k) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three |
| 5 | Supply, installtion,testing commisioning of LT panel, CPRI approvedout door typeofsize not less than 1300x500x1900mm,platform mounted, totally enclosed, dust and vermin proof, openablefrom both front and rear side, made out of 3.15 mm thick CRCA sheetincluding inner chambers / partitions to mount the following electrical accessories with angle iron75x75x6mm frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminiumstrip of suitable size and necessary grouting/ foundation all as required at site including dismantling and taking down of old unserviceable panel including replacement of lugs for incoming / outgoing cables as per existing allas specified & directed :- |
| 6 | BUS BAR - Aluminium bus bar system of capacity 300 amp four pole duly colour coded.INCOMER - MCCB, 4 poleof capacity 250 amps with breaking capacity of 36 KA . - 01 No.Outgoing - (a) MCCB, 4 poleof capacity 160 amps with breaking capacity of 25 KA . - 01 No.(b)MCCB, 4 poleof capacity 100 amps with breaking capacity of 25 KA . - 02 No.(c)MCCB, 4 poleof capacity 63 amps with breaking capacity of 25 KA . - 02 No.(d)MCB, 4 poleof capacity 32 amps with breaking capacity of 10 KA . - 02 No.(e)MCB, 4 poleof capacity 63 amps with breaking capacity of 10 KA . - 01 No.(f)MCB, 4 poleof capacity 6 amps with breaking capacity of 10 KA . - 01 No. (g) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered locor loc coordinates -01No (j)Digital multimeter - 01 No (k) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three |
| 7 | Supply, installtion,testing commisioning of LT panel, CPRI approved out door type ofsize not less than 1900x1300x500mm, platform mounted, totally enclosed, dust and vermin proof, openablefrom both front and rear side, made out of 3.15 mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories with angle iron 75x75x6mm frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting/ foundation all as required at siteincluding dismantling and taking down of old unserviceable panel including replacement of lugs for incoming / outgoing cables as per existing allas specified & directed :-BUS BAR - Aluminium bus bar system of capacity 300 amp four pole duly colour coded.INCOMER - MCCB, 4 poleof capacity 160 amps with breaking capacity of 36 KA . - 01 No.Outgoing - (a) MCCB, 4 poleof capacity 100 amps with breaking capacity of 25 KA . - 01 No.(b)MCCB, 4 poleof capacity 63 amps with breaking capacity of 25 KA . - 02 No. contd... |
| 8 | (c)MCB, 4 poleof capacity 32 amps with breaking capacity of 10 KA . - 02 No.(d)MCB, 4 poleof capacity 63 amps with breaking capacity of 10 KA . - 01 No.(e)MCB, 4 poleof capacity 6 amps with breaking capacity of 10 KA . - 01 No. (f) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01 (g)Digital multimeter - 01 No(h) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three |