| 1 | Excavation in trenches not exc. 1.5 mtr wide and depth not exc. 1.5 mtr for foundation, laying GI pipes and UG cables etc not exc 10 sqmtr on plan, in soft/loose soil and getting out complete all as specified and directed. |
| 2 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 3 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 4 | Supply and laying 50 mm outside dia double wall corrugated pipe (DWC pipes SN-8) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. |
| 5 | Materials and labour for GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed. |
| 6 | Supply and laying in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 sqmm 4 coreincluding taking down old unserviceable cable and making necessery connections all as specified and as directed. |
| 7 | All as item no 6.00 but of size of cable 16 sqmm 4 core |
| 8 | All as item no 6.00 but of size of cable 10 sqmm 4 core |
| 9 | All as item no 6.00 but of size of cable 10 sqmm 2 core |
| 10 | Taking out old servicable tilted poles and refixing same at location as directed by engineer-in-charge including excavtion for taking out complete all as directed.Note:- PCC for foundation and coping work shall be measured and paid separately under respective items. |
| 11 | Supply and fixingSteel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws of type 410 SP-31(9 metre long) including taking down old unserviceable RCC pole complete all as specified and directed. |
| 12 | Labour only for taking down any unserviseable street light fittings/flood light/garden light/gate light/fountain light fitting any type/size and refixing same after repair/replacement of all unserviceable accessories of any type and size from existing position/location or removing connection oxide by cleaning terminals and shifting materials to store for keeping in safe custody for repair work or taking credit complete all as specified and as directed. (Note: Items if required for repair work will be measured and paid seperately under relevant items) |
| 13 | Supply only MS adopter for street light fitting of existing size and shape with nut bolts inclusive of one primer coat , one finished coat of aluminium paint all as specified and as directed. |
| 14 | Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint heat shrink type, complete with jointing materialand accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 16 to 50 Sqmm,complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately) |
| 15 | Materials and labour for PCC, type C1, (1:3:6), using 20mm graded crushed stone aggregated, as in foundation of poles, panels etc. with necessary formworkincluding demolition of old damaged concrete from pole complete all as specified and as directed |
| 16 | Materials and labour for PCC, type B1, (1:2:4), using 20mm graded crushed stone aggregated, as in coping of poles including formworkincluding demolition of old damaged concrete from pole complete all as specified and as directed |
| 17 | Materials and labour PCC, type D2, (1:4:8), using 40mm graded crushed stone aggregated, as in PCC on road cutting /installation area and foundation of pole etccomplete all as specified and as directed. |
| 18 | Materials and labour for boring holes for 100mm dia pipe upto 2mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items). |
| 19 | Supply and fixing in repair LED 25 W warm white colour building security light made up of pressure die cast housing with high efficient LED as lighting source and toughned glass cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia 40 mm complete all as specified and directed. |
| 20 | Supply and fixing in repairLED street light of capacity 70 Watt made up of pressure die cast aluminium housing withhigh power LED as light source and lens embedded toughned glass including electronic driver should have luminaire efficacy ≥140 lumens/watt, CRI>70, PF > 0.95, CCT=5700±300, IP66,impact resistance IK 07, inbuiltprotection against lightning, over voltage, short circuit and surge/spike protection upto 10KV including suitable fixing arrangement with 40mm dia existing braket and connection suitable for 40mm dia braket with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmm x 3 core from light fitting to pole box complete all as specified and directed. |
| 21 | Supply only LED Garden spike light 12 W , with dust jet water protection including taking down old u/s and making necessery connections complete all as specified and directed. |
| 22 | Supply and fixing LED light water proof light having IP-68 under water Led light 10 watt compatible for fountains white/warm white colour including taking down old u/s and making necessary connections complete all as specified and directed. |
| 23 | Supply and fixing in repair LED warm white bollard light 9W LED bollard with opal acrylic diffuser having arrangements for replacing the LED bulbs and IP66 protection suitable for dia upto 60mm complete all as specified and directed. |
| 24 | Supply and fixing in repair warm white LED 20 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and directed. |
| 25 | Supply and fixing in repair warm white LED 40 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and directed. |
| 26 | Supply and fixing in repair LED flood light warm white colour 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed. |
| 27 | Supply and fixing in repair LED flood light warm white colour 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed. |
| 28 | Supply and fixing all in one solar street lights 60 Watts, LiFO4( Lithium ferro phosphate battery) with 2000 life cycles, high system efficiency 180 lumen/watts, auto turn on/off by sensing dusk down,PIR sensor based dimming profile, Integrated MPPT charge controller with efficinecy>90%, CRI>70, CCT 5700K, IP65, including 7 m octagonal poles including foundation as recommeded by OEM charge controller protection : Open circuit, short circuit & Reverse polarity, life span 50000 Hrs, IK 08 for lens complete all as specified and as directed by Engineer-in-Charge. Make: Phillips signify model : BRP111 or equivalentNote : The rates for foundation of octagonal poles as per OEM recommendation shall deemed to be inclusive in the quoted rates. |
| 29 | Supply and fixing in repair LED lights driver of existing make for bollard light/post top lamp/building security light upto 40 watt complete all as specified and as directed. |
| 30 | Supply and fixing in repair LED lights driver of existing make for bollard light/post top lamp/building security light upto 120 watt complete all as specified and as directed. |
| 31 | Materials and labour for taking out oldunservicable flood light from high mast poles upto 16M height and refixing same after repairing complete all as specified and as directed. The quotated rates shall be inclusive of all safety arrangements and cost of making scaffolding /hiring of cranes for taling down flood lights upto 16M height. |
| 32 | Materials and labourfor water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel/RCC poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. |
| 33 | Materials and labourfor water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 2.5 sqmm, 1100 Volts gradeincluding PVC conduits properly fixed on steel/RCC poles using GI wirefor electrical connection of street light fittings, complete all as specified and directed. |
| 34 | Supply and fixing 20 mm dia PVC conduit on the Steel/RCC poles, fixed by using GI clamp of suitable size including nuts and boltsby disconnectingexisting open/loose 1.5 Sqmm single/three core pvc wire and inserting same in PVC conduit complete all as speciifed and as directed. |
| 35 | Supply and fixing in repair 3 pole power contactor of AC3 rating 32 Amps , with built in surge suppressor , RoHS compliant including necessary electricalconnection with suitable size of copper cable complete all as specified and directed. |
| 36 | Supply and fixing in repair coil for contactor MO32, 415V all as specified and directed |
| 37 | Material and labourfor Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm burieddirectly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 25 X 4mm dia GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etcRCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate)including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed. |
| 38 | Material and labourfor Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm burieddirectly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 20 X 3mm copper strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etcRCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate)including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed. |
| 39 | Supply and fixing thermoplastic polycarbonate cable junstion box having protection IP 66\"dust proof, acid resistant, shock proof, fire retardent self extinguisher\" for outside installation with knockout entry for cable of size 10-35sqmm, 295x195x100 mm with terminals, brackets for street light pole mounting and including of one 6A MCB SP all as specified and as directed. |
| 40 | Materials and labour for servicing of cable junction box by taking out old serviceable cable and refixing same after dressing the cable and inserting suitable size lugscomplete all as specified and as directed. |
| 41 | Materials and labour for repairing of junction boxes by replacing all cable terminals followed by dressing of cable heads and refixing with two aluminium strips with nut bolts all as directed. |
| 42 | Servicing of LT Panel after shut downand removing all dust particles and proper layout of LT panel wlth gland packing including 2.5 sqmm copper single core copper cable including repairing/replacing door hinges/door lock etc and for necessary connections complete all as specified and directed |
| 43 | Materials and labour for Preparation of metalic surface with sand paper for street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge |
| 44 | Materials and labour for aluminium paint two coats on newly primed metalic surface of street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge |
| 45 | Materials and labour for two coats of Yellow/black synthetic enamel paint on metalic surface complete all as specified and as directed by Engr- in-Charge |
| 46 | Materials and labour for preparation of old concrete/plastered surfaces of poles and pole copings and applying two coats of Cement based paint complete all as specified and as directed by Engr- in-Charge |
| 47 | Taking down existing faulty LT UG cable line 1100V of any size from existing location and relaying serviceable portion of LT UG cable after necessary repair work at fault location, providing joints etc. if requiredall as specified and as directed(Note: Items required for repair, joint and excavation works will be measured and paid separately under relevant items. Only serviceable portion relayed shall be measured for payment) |
| 48 | Taking out old bricks/cable cover and relaying after cable repair workcomplete all as specified and as directed. |
| 49 | Supply and fixing bracket for street light of 40mm dia of 1.50 mtr length with 02 x clamps of existing size and shape and 04 Nut bolts inclusive of one coat of primer followed by one coat of aluminium paint with finishing complete all as specified and as directed. |
| 50 | Supply and fixing bracket for street light of 25mm dia of 1 mtr length with 02 x clamps of existing size and shape and 04 Nut bolts inclusive of one coat of primer followed by one coat of aluminium paint with finishing complete all as specified and as directed. |
| 51 | Materials &Labour for concealed submain wiring with two single core PVC insulated,unsheathed,stranded copper conductor, FRLSH,of size 1.5 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH,of size 1.5 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completionincludingtaking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge. (Note: Two runs of 1.5 Sqmm cable and one run of 1.5 Sqmm earthing cable along with conduit altogether shall be measured as one unit.) |
| 52 | Supply and fixing in repairswitch piano flushtype single pole one way 5 Amps |
| 53 | Supply and fixing in repair PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep for mounting switches. |
| 54 | Supply and fixing in repair ceiling rose surface bakelite 50x25 mm three terminal complete all as specified and as directed |
| 55 | Supply and fixing retro reflective tape of width 50 mm red/yellow colour having suitable adhesion for fixing over the surface of street light poles in the layers complete all as specified and as directed.Make: 3M or equivalent |
| 56 | Supply and writing pole number by using retro-reflective sheet board as per nomenclature provided by the Engineer in Charge complete all as specified and as directed. |
| 57 | Labour only for taking out old unservicable street light/LT/HT PCC/Steel tubular poles by excavating 0.5m below the ground level and stacking at a location upto 1 Km from the actual location of the retrival of the pole complete all as specified and as directed. |
| 58 | Supply and fixing in repair stainless steel 2 way Fire Brigade Inlet connection ISI marked with inbuilt Check Valve including taking down and removed from site complete all as specified and as directed. |
| 59 | Supply and fixing in repair stainless steel 63 mm bore Heavy Duty Single Headed Fire Hydrant Landing valve As per IS:5290 type \"A\" ISI marked with ABS Blank capincluding taking down unserviceablve valve and removing from site complete all as specified and as directed. |
| 60 | Supply and fixing in repair Hose reinforced rubber lined fire Pipe ofSize 63 mm bore ( 15 Mtr Length ) WithBoth Side SS coupling ISI marked Male & Female connection type including taking down complete all as specified and as directed. |
| 61 | Supply and fixing in repair Branch Pipe with SS Nozzle as per IS 903 ISI marked including taking and removing from site down complete all as specified and as directed. |
| 62 | Supply and fixing in repair of Hosebox made of 18 gange MS sheet 800 mm x 600mm x 250 mm with double door with 4 mm thick glasses and door fram made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete including taking out old unservicebale Hose box and removing from site compelte all on specified and directed. |
| 63 | Supply and fixing in repairHose reel Drum ( Wall Mounted) swingingtype as per IS : 884 includingHose pipe Length 30 Mtr Long of Size:- 20 mm bore thermo plastic hose as per IS 12585, ISI markedwith PVC ¾ “ Shutoff Nozzle (Hydraulically Crimped) including taking down and removing from site complete all as specified and as directed. |
| 64 | Supply and fixing in repair PVC Shut off Nozzle Size 20 mmbore ISI marked including taking down complete all as specified and as directed and removing from site. |
| 65 | Supply and fixing in repair Hose Clamp including taking down and removing from site complete all as specified and as directed. |
| 66 | Supply & Refilling of Carbon di Oxide Fire Extinguisher 4.5 Kg each complete all as specified and as directed. |
| 67 | Supply & Refilling of ABC Powder Fire Extinguisher 6 Kg Each complete all as specified and as directed. |
| 68 | Supply & Refilling of D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each complete all as specified and as directed. |
| 69 | Supply & Refilling of Watermist baseFire Extinguisher 9 Ltr capacity each complete all as specified and as directed. |
| 70 | Supply and fixing in repair Fire Extinguisher Hose Pipe ABC Type |
| 71 | Supply and fixing in repair Fire Extinguisher Hose Pipe CO2 Type |
| 72 | Supply and fixing in repair valve kit for Fire ExtinguisherABC Type |
| 73 | Supply and fixing in repair Fire Extinguisher valve for foam type |
| 74 | Supply and fixing in repair Fire Extinguisher valve forWatertype |
| 75 | Supply and fixing in repair Pressure Meter |
| 76 | Supply and fixing in repair Hanging Clip ( Hooke ) for Fire Extinguisher |
| 77 | Supply and fixing in repair Carbon di Oxide Fire Extinguisher 4.5 Kg each |
| 78 | Supply and fixing in repair ABC Powder Fire Extinguisher 6 Kg Each |
| 79 | Supply and fixing in repair D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each |
| 80 | Supply and fixing in repair Watermist baseFire Extinguisher 9 Ltr capacity each |
| 81 | Labour only for Control Panel Fault Detection & Rectification by changing Necessary defective Components along with necessary copper wire, Lugs, Terminal etc. including testing on complete all as specified and as directed.(Note : Spare parts will be measured and paid separately underrespective items). |
| 82 | Supply only 3 Pole 32 A Power Contactor |
| 83 | Supply only Thermal Overload Relay ,Relay Range 14-23 A |
| 84 | Supply only Setof 3 Phase Indicating Lamps (Red Yellow & Blue) |
| 85 | Supply only Push Button Assembly with auxiliary contact BlockStart & Stop |
| 86 | Supply only 63 Amp TPN MCB10 KA |
| 87 | Supply only 1 Pole 2 Way Rotary Cum Switch for Auto & Manual selection |
| 88 | Supply only Single Phase Preventer |
| 89 | Supply only Danfoss Make KP35 Pressure Switch |
| 90 | Supply only Ball Valve 15 mm |
| 91 | Material and labour for PVC Insulated & PVC Shethed Multi core bright Annealed bare Copper Conductor flexible Round Cables Size 1 Sq mm 2 core FRLSH complete all as specified and as directed. |
| 92 | Servicing of motor pump set of capacity 7.5/10 HP by disassembling, (i) Motor Front over and back cover part by part dismantling, Internal Coil Heat Varnish, Insulation Testing & refixing. (ii) Pump Part by part Dismantling, ThroughServicing, replacement ofbearing & Gland Packing /Mechanical seal,re assembly with proper alignment complete all as specified and as directed. |
| 93 | Material and labourfor rewinding of motorwithsuperior quality copper winding wire of existing size including varnishing and drying, cable jointing and repair replacement of worn at parts of motor/pump reassembling, re-installing at site and testing the samecomplete all as specified. |
| 94 | Material and labour for painting of motor pump set complete all as specified and as directed |
| 95 | Material and labour painting of fire fighting water MS pipeline by red colour syntheitic enamelled paint by suitable safety arrangement upto height of 20 mtrs height complete all as specified and as directed. |
| 96 | Material and labourfor repairing of fire fighting alarm controlpanel& Rectification by changing Necessary defective Components alongwith necessary copper wire, PCB repairng work including testing on completion complete all asspecified and as directed. |
| 97 | Supply and fixing in replacement fire alarm metallic body ISI marked complete all as specified and as directed. |
| 98 | Supply and fixing Manual call point ISI marked PVC/ABS bodywall mounting type including grouting of MCP on wall using 1:3:6 plaster complete all as specified and as directed. |
| 99 | Supply, laying, jointing & testing MS tubing heavy grade 100mm tubing with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches or fixing complete with clips, wall hooks etc. complete all as specified and directed. |