| 1 | FLOORING BREAKING: Dismantling carefully the existing damaged cracked serviceable tiles/slabs/clay tiles/Marble slab/granite slab/Kota stone/tandoor stone/Shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including stacking of serviceable material out of hospital premises as directed by the Engineer-in-Charge. |
| 2 | MASONARY BREAKING: Demolishing existing damaged/cracked brickmasonry with cement mortar and plaster at all floors and levels including scaffolding stacking of serviceable materials without damaging the adjacent masonry/RCC structure sanitary fittings & fixtures and disposal of unserviceable material carting away the debris out of hospital premises complete all as directed by the Engineer-in-Charge. |
| 3 | SOLING: Providing & laying rubble stone soling using spotless stones below floors roads/pavements etc. mechanically / manually consolidated thickness as specified below with stones vertically handset interstices packed with smaller stone chips, binding with murrum & sprinkling water for proper consolidating and finishing to required levels in quantities as and when required etc. complete all as directed by the Engineer-in-Charge. of 150 to 230mm thick |
| 4 | Plain cement concrete 1:2:4 using graced stone aggregate of 20mm / 40mm max. size including consolidation using vibrator & needle if required finishing, curing, form work shuttering, centering etc. complete all as per specification and in quantity as & when required by the Engineer-in-Charge, |
| 5 | REINFORCED CEMENT CONCRETE: (RCC) Reinforced cement concrete of specific grade grade using graded stone aggregate of 20mm max. size including consolidation with vibrator & needle of required capacity finishing Curing,inlcuding form work, shutteringetc. complete all as directed by the Engineer-inCharge. In slabs, chaijas, canopies, columns, shelves window sills staircases walls beams intels bed blocks etc. 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20mm |
| 6 | REINFORCEMENT: Reinforcement for reinforced cement concrete at all floors and levels including supplying cutting bending fixing and binding in position with 1.6mm dia soft drawn annealed binding wire including cost of binding wire labour etc. complete all as per specifications and as directed by the Engineer-in-Charge. (laps will not be measured). With high yield strength deformed bars (TMT bars) & MS round bars |
| 7 | STRUCTURAL STEEL WORK: At all levels including supplying cutting fabricating welding or blotting erecting and fixing in position including painting with a primary coat of approved steel primer, including cost of materials labour with chasing in wall or embedding in floor and making good the same by filling 1:2:4 cement concrete and plastering if necessary all as specified and directed by Engineer-in-Charge. Built-up seciton/ tubular sections |
| 8 | Providing and laying at or near ground level factory made kerb stone of M-25 Grade cement with nominal reinforcement in position to the required line, level and curvature jointed with cement morter 1:3 (1 cement : 3 corse sand) includin making joints with or with out grooves (thickness of joints except at sharp curve shall not more than 5mm) including making drainage opening whever required complete etc., as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone of 900x300 size approx shall be approved by Engineer-in-charge ) |
| 9 | CEMENT PLASTERING: Cement Plastering for internal wall and ceiling with cement mortar 1:4 finished smooth with neeru over brick walls of concrete surfaces including hacking the concrete surfaces at all floors and levels in quantities as required at site including scaffolding curing, etc. complete all as directed by Engineer-in-Charge. |
| 10 | Providing & laying approved make and desing 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 coarse sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar : The material be exterior grade type to be used for heavy vehicular movment, manufactured byu any reputed company comple as directed and instucted. |
| 11 | Synthetic enamal paint to MS Strucuture with one coat of primer and two coat of approved colour paint including scafolding etc complete as directed and instructed. |
| 12 | Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).The material be exterior grade type to be used for heavy vehicular movment, manufactured byu any reputed company comple as directed and instucted. |
| 13 | External painintg Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications of approved shade complete as directed and instructed. |
| 14 | BRICK WORK: Brick work at all floor level with cement mortar 1:4 using well burnt locally available bricks of approved quality including scaffolding, raking out joints above ground level simultaneous and as directed by engineer in charge. In foundation & plinth drain walls chambers & superstructure of all floor levels. |
| 15 | Providing and fixing Aluminium Composite Panel (ACP) curtain wall system of 4mm thick matching existing ACP Panel or approved colour and makefixing over aluminium frame of 50mm x 25mm thick in grid form including cutting bending, ACP to required size and shape, fixing on Aluminium frame with weather Silicon sealant and finishing the groove with black colour sealant as per manufacturer’s specification complete all inclusive of wastage, labour, shifting, transportation etc.as directed and instructed by Engineer incharge. for trap door etc |
| 16 | Providing, fixing, jointing and testing of UPVCAgripipes confirmingto IS : 4985 (Pipe Class III - 6 kg / sq.cm) cut to required lengths including all necessary fittings and specials such as bends, junctions offsets, access pieces (plain or door) & vent cowl with Solvent Joint .Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. ( Terrace RWP) 110mm nominal bore |