| 1 | Dismantling tile work in floors and dados laid in cement mortar including stacking the materials within 50 meters lead (For thickness of tiles 10mm to 25mm) |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 6 | Providing and laying Ceramic glazed floor tiles of size 300x300mm (thickness to be specified by manufaturer), of 1st quality conforming to IS:15622, of approved make,in all colours, shades, execept white, Ivory, Grey, Fume Red Brown, laid on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @3.3 kg/sq.m includng grouting the joints with white cement and matching pigments etc. complete. |
| 7 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shad complete. |
| 8 | Dismantling doors, windows wooden kitchen mesh almirah and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below |
| 9 | Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer\"s specification and direction of Engineer -in- charge. |
| 10 | 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer\"s specification and direction of Engineer in-charge.Non decorative finish (matt finish) |
| 11 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq.m and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of ngineer-in-charge with cement mortar 1:4 (1 cement : 4 fine sand). |
| 12 | Providing and fixing SS towel rail 450mm long complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour (total length of 495mm, 78mm wide and effective height of88mm, weighing not less than 170 gms) |
| 13 | Providing and fixing waste pipe for sink or wash basin including waste fittings complete. flexible pipe 40mm dia. |
| 14 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back Wash basin size 450x300 mm with a single 15 mm C.P. brass pillar tap |
| 15 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 16 | Providing and fixing 600x450mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washer complete |
| 17 | Providing and fixing CP brass toilet paper holder |
| 18 | Providing 15mm diameter nominal bore CP brass long nose bib cock of approved quality confirming to IS:8931 with provision for fixing health faucet (two in one) and weighing not less than 810 gms. |
| 19 | Providing CP brass extension nipple (size 15mm x 50mm) of approved make and quality as per direction of engineerincharge |
| 20 | Providing and fixing 100mm sand cast iron grating for gully trap |
| 21 | Distempering with 1st quality acrylic distemper, having VOC content less than 50gms/ltr, of approved and manufacture, including applying additional coats whereever required, to achive even shade and colour. one or more coats on old works . |
| 22 | Providing and fixing 3 layer PP-R (Poly propylene RandomPN - 16 Pipe, 20mm OD (SDR-7.4) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. |
| 23 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes |
| 24 | Providing and fixing 100mm diameter Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge |
| 25 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 100 mm diameter |
| 26 | Providing and installation of 2 in one wall bath Mixer, including GST, transpotation charge, carriage, fixing charges etc. complete. |
| 27 | Providing and installation of 15mm CP two way bib cock including 15mm diameter CP Health Faucet of 1.2m length, including GST, transpotation charge, carriage, fixing charges etc. complete. |
| 28 | Miscellaneous civil jobs like providing connection to new European WC Pan with \"S\" or \"P\" trap with existing main sewer linewith all operations including making holes at wall to carryout pipe line from bath cum toiletto main sewer line by making connection including all materials, labour, and dismantling of PCC work ,excavation allcomplete as per direction of Engineer-incharge.The work also includelaying PCC , plastering work ,disposal of dismantled materials, malba as directed. |
| 29 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 30 | Installation, Testing and Commissioning of pre-wired,LED fitting of 10-20 Watt Warm White type on mirror, complete with all accessories and tube etc. directly on wall including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. asrequired. |
| 31 | Supplying, Installation, Testing & Commissioning of 18-22 Watt LED surface mounted Batten Tubelight ofbody material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KVwith Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of inimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025 Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 32 | Wiring for circuit/ submain wiring along with earth wirewith the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wiresizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface medium class PVC conduit as required. |
| 33 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 34 | Supplying, Installation, Testing & Commissioning of Storage Geyser (15 Litre) includingproviding connection from the installed newly power point, screws, gutkaas, transpotation charges,carriage of materials, taxes etc. |
| 35 | Note-1: General Notes1.For their own interest, contractors are advised to inspect the site with prior permission before quoting their rates. 2. All the dismantled /demolished materials shall be dumped at one place as decided by the department within 150mtr lead.3. All the samples of materials which are to be used shall be approved by the department in advance. 4. The contractor shall comply with the provision of the Payment of Wages act5. Rates quoted shall be inclusive of all cost of materials, labour, carriage, taxes, GST, labourcess, water charges, elctricity charges, signorage charges, wastages etc.. 6. Rates quoted shall be excluding the amount of EPFO and ESIC contributions. EPFO and ESIC contributions are reimbursableon production of valid proof of payment made by the contractor as per CPWD norms. |