|
| 1 | Painting two or more Coats excluding priming coat with Ready Mixed paints for metallic surface in all shades on steel or iron work for kanjalo Cross Regulator gates and structure at R.D. 207730 of Kali Holy Bein. (a) With Special quality Paint supply and carriage & loading unloading of all material complete in all respect as per specification and Direction of Engineer in Charge. |
| 2 | Painting two or more Coats anti-coorosive ordurless black bitumastic Paint inside steel water tanks supply and carriage & loading of all material complete in all respect as per specification and Direction of Engineer in charge. |
| 3 | Scraping Brushing to remove paint to base metal surface. |
| 4 | Applying Priming Coat with metal Primer on new steel or iron work including preparation of surface. (a) with special Quality Paint supply and Carriage & Loading Unloading of all Material complete on all respect as per specification and Direction of Engineer in Charge. |
| 5 | Supply of Multipurpose synthetic Grease Complete in all respects and to entire satisfaction of engineer-in-charge.1 No. gates used multipupous grease = 2kg Total 12 No. gates Qty = 12 x 2 = 24kg. |
| 6 | Mobile oil (5 ltr packing) Supply and carriage & Loading Unloading of all material complete in all respect as per specification and Direction of Engineer in Charge.1 Gears system used multigrade mobile oil = 2 ltr Total 12 No. gates (2 gears for each gate) =12x2=24 gears Qty = 24x2= 48ltr |
| 7 | Supply and istallation of new steel wire rope in position i/c linking of gate and hoist mechanism for smooth balance operation i/c oiling and greasing complete in all respect as per specification 637 IS code 2266 and to entire satisfaction of Enginer in charge. |
| 8 | Bearing 22210E (SKF) |
| 9 | Pully 300 Dia, 50 wide (IS Code 1030) |
| 10 | Removing damaged old rubber seal bulb or flat including clamp plate of all sizes (quantity same as item 12 and 13) |
| 11 | Removing damaged structural steel and stacking clear from working space by gas cutting complete in all respect and entire satisfaction of engineer in charge(quantity same as item 26) |
| 12 | Providingof hollow bulb seal( Side Seal ) and fixing of position including prepration of the surface complete in all respect and entire satisfaction of engineer in charge (12+12\")x12 gates (100/44) |
| 13 | Providing and fixing of flat wedge seal i/c preparation of surfacecomplete in all respect and entire satisfaction of engineer in charge (15\"x12 gates) (75x12) |
| 14 | Providing and fixing of stainless steel nut and bolts of all sizes and length required |
| 15 | Drilling/boring hole including complete in all respect and engineer in charge (0-10mm) |
| 16 | First class burnt brick work laid in cement sandmortar 1:3 in first storey upto 4 metres aboveplinth level. |
| 17 | Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade |
| 18 | 12.5mm th. Cement plaster 1:3 |
| 19 | First class burnt brick work laid in cement sandmortar 1:4 in foundation and plith |
| 20 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 21 | Wiring fan point (With fan box) |
| 22 | Wiring 6Amp. wall socket point |
| 23 | wiring light point with double control switches |
| 24 | Plastic Chair |
| 25 | Plastic Table |
| 26 | Factory manufactured flush door fixed in position iron hinges , etc( excluding the cost of any fittings other than specified above but including labour for fixing the same in position ( a ) commercial with elm or gurjan facing on both / sides laminated core and lipped edges:- (iv) 35 mm thick |
| 27 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notchprovision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete (Doors and windows frame of size 118mmx 60mm with 40 mm wide single rebate weighing 3.43 kg per meter. |
| 28 | Corrugated asbestos Sheet roofing 6 mm thicksheets fixed with G.I. hooks and bolts, limpet andbitumen washers complete fixed in positionexcluding the cost of perlins, rafters and trusses. |
| 29 | Supply and fixing MS cover for rope drum i/c cost of hinges and lifting hooks i/c labor charges. |
| 30 | Providing chequred plate 8mm thick of desired shape and size complete in all respect and to entire satisfaction of engineer in-charge. |
| 31 | Providing and Fixing MS Nut and Bolts of all Sizes and length required and to entire satisfaction of Engineer-in-charge. |
| 32 | Providing and fixing 2 mm MS sheet for gearing system i/c removal and credit of old damaged MS sheet cover and nut bolts, paint and all required accessories |
| 33 | Providing and fixing grease nipples and making necessary arrangement on existing plumber blocks and gearing system. |
| 34 | Plumber block as per list and make SKF, NBC |
| 35 | Fillet Welding with high strength steel rods complete in all respects and to entire satisfaction of enginer incharge (i) 6 mm wide. |
| 36 | Providing skin plate of Gates (8mm) of desired shape and size complete in all respect and to entire satisfaction of engineer in-charge. |
| 37 | Providing and fixing U clamp of steel wire rope complete in all respect and to entire satisfaction of engineer in-charge. |
| 38 | Removing, providing and fixing clamp plate complete in all respect |
| 39 | Fixing and holding gates with the help of 35 tonne capacity crane. |
| 40 | Overhauling of gate gearing system of all type i/c dismantling, greasing, oiling and re-installation of mechanism complete in all respect (ii) more than 10 ft |
| 41 | Removing and fixing of roller pin in position complete in all respect and satisfaction of Engineer in charge |
| 42 | Filling cement bags with sand, sewing andlaying in position within 30 meters in waterincluding cost of E.C bags and strings. |
| 43 | Supply of Mazdoor for removal of bandh/ clearing silt which was deposit in front of gates. |
| 44 | Removing and fixing bearing complete in all respect |
| 45 | Providing and fixing Ceiling fan (havells,usha, crompton etc.) |
| 46 | Conglomerate floor 40mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling. using mechanical mixer for mixing of material |
| 47 | Damp proof course 2.5cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded |
| 48 | Tower Bolts (Barrel type) Anodized AluminumMat Finish 200mmx10mm. |
| 49 | Sliding door bolts - Anodized AluminumMat Finish 250mmx16mm. |
| 50 | Supply of Brush Cutter with Honda GX 35 engine |
| 51 | Providing and fixing LED batten 20 w |
| 52 | Any Other Item Please Enable Macros to View BoQ information |