| 1 | Taking down cement plaster on brick work or stone walls, etc upto 12 mtr height including raking out joints, hacking for key, scrubbing down with water, etc all as specified including removal of debris from site to outside MoD land. |
| 2 | M&L for 15mm thick rendering in cement mortar (1:4) in patches not exc 5 Sqm on brick or concrete surface of wall including finished even and smooth surface without using extra cement including mixed with liquid water proofing compound as per manufacturer\"s instruction upto 12 mtr height complete all as specified. (Note :- Liquid WPC will be measured and paid separately). |
| 3 | M&L for 15mm thick rendering in cement mortar (1:6) on brick or concrete surface of wall including finished even and smooth surface without using extra cement complete all as specified. |
| 4 | Supply only liquid water proofing compound. |
| 5 | M&L for 10 mm thick rendering in cement mortar (1:3) on concrete surface on ceiling including finished even and smooth surface without using extra cement all as specified. |
| 6 | M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint all as specified. |
| 7 | M&L for preparation of newly plastered surface of wall and applying two coats ofoil bound distemper over a coat of wall primer all as specified. |
| 8 | M&L for three coats of white wash on ceiling including preparation of newly plastered surfaces all as specified. |
| 9 | M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of wall primer all as specified. |
| 10 | M&L for applying 3 mm thick (average) wall care putty on wall for finishing the surface to an even and smooth by sand papering etc all as specified. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding / terrazo dado etc (but not backing) including removal of debris from site to outside MoD land. |
| 12 | M&L for glazed ceramic coloured tile joint free first quality of size 350 mm x 250 mm x 7 mm/ 450 mm X 350 mm X 7 mm thick as on vertical surface such as wall, dado, skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over a 10 mm cement plaster of 1:4 on fair faces of brick work or concrete surfaces all asspecified and directed. |
| 13 | M&L for 25 mm thick cement concrete (1:2:4) type B-0 using 12.50 mm graded stone aggregates all as specified. |
| 14 | S&F for vetrified ceramic light shade tiles first quality polished 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36 Sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile including 15 mm thick screed bed or bedding layer in cement mortar 1:6 all asspecified. |
| 15 | S&F for non skid ceramic colouredtiles, joint free, first quality polished of 7 mm to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile including 15 mm thick screed bed or bedding layer in cement mortar 1:6 all asspecified. |
| 16 | Demolition of brick work built in cement mortar or cement lime mortar including all quions, arches, pillars etcincluding removal of debris from site to outside MoD land. |
| 17 | M&L for fly ash brick work, straight or curved on plan exc6.0 mtr mean radius and built in cement mortar 1:6all as specified. |
| 18 | Taking down chowkat or frame with shutters with fittings (without taking off shutter from frame) area exc 1.5 Sqm & not exc 4 Sqm each. |
| 19 | Taking down chowkat or frame with shutters with fittings (without taking off shutter from frame) area not exc 1.5 Sqm each. |
| 20 | Taking down shutter of any description with fittings area exc 1 Sqm and not exc 2 Sqm each leafall as specified. |
| 21 | Taking down existing shutter of any description and repairing, easing, adjusting etc and then re-fixing in the same opening area exc 1 Sqm and not exc 2 Sqm each all asspecified. |
| 22 | Taking down existing shutter of any description and repairing, easing, adjusting etc and then re-fixing in the same opening area not exc 1 Sqm each all asspecified. |
| 23 | S&F for factory made PVC door frame of size 50 mm x 47 mm with a wall thickness of 5mm grid PVC sheet mitered at corner and pinned with two members 150 mm long brackets of 15 mm x 15 mm mild steel Square tube 19 gauge EPDM rubber gasket weathered sheet to be provided through the frame, door frame to be fixed to the wall suing MS screw of 65 mm /100 mm size complete as per manufacturer specification. |
| 24 | S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of framemade out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheetbeading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing all as specified and directed by Engineer-in-Charge. |
| 25 | S&F for factory made pressed steel frames for doors of size 125 mm x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc as specified. |
| 26 | S&F for factory made pressed steel frames for doors of size 105 mm x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc as specified. |
| 27 | S&F for 30 mm thick factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides all as specified. |
| 28 | S&F for 30 mm thick second class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) for doors; supplied and fitted to chowkats all as specified. |
| 29 | S&F for 30 mm thick second class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc with sash bars, divided into squares, with plain, chamfered or rounded, mitred, edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) for doors; supplied and fitted to chowkats all as specified. |
| 30 | S&F in repair 18 mm pre-laminatd particle board, interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified. |
| 31 | S&F in repair 12 mm pre-laminatd particle board, interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified. |
| 32 | S&F in repair 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as specified. |
| 33 | S&F in repair solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheetinclusive of solvent cement and fixing at site on PVC frame as per specifications. |
| 34 | S&F in repair continuous (piano) hinges, mild steel, bright finish width of flaps (when open) in 30 mm or electrogalvanised all as specified. |
| 35 | S&F for 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified. |
| 36 | S&F for 250 mm long aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified. |
| 37 | S&F for 100 mm long mild steel butt hinges, cold rolled, medium type and fixed all as specified. |
| 38 | S&F for 125 mm extruded aluminium alloy handles, fabricated type, anodised all as specified. |
| 39 | S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed all as specified. |
| 40 | S&F in repair 300 mm mild steel ordinary rat tail rod patttern springs includding roller and roller plate all as specified. |
| 41 | M&L for preparation of newly wooden surfaces of any description not otherwise described over 10 cm wirdh or girth and applying two coats of synthetic enamel paint (1st quality) over one coat of pink primer all as specified |
| 42 | M&L for preparation of newly steel surfaces of any description not otherwise described over 10 cm wirdh or girth and applying two coats of synthetic enamel paint (1st quality) over one coat of red oxide zinc chromate primer all as specified |
| 43 | M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described and treated small article such as holdfasts, ends of posts, backs of chowkats etc area not exc 0.1 Sqm each with tar or coal tar black paint all as specified. |
| 44 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in bedblock of hold fast including necessary from work all as specified. |
| 45 | S&F for mild steel for bands, straps, supports or stays for rainwater, hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 all as specified. |
| 46 | S&F in repair factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay & mild steel tower bolt 100 mm (4 Nos) with glazing bars, dovetailed or weldedall as specified. |
| 47 | S&F in repair factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay & mild steel tower bolt 100 mm (4 Nos) without glazing bars, dovetailed or weldedall as specified. |
| 48 | S&F for factory made steel ventilator with top hung shutters including box type hinges, peg staywith glazing bars, dovetailed or welded all as specified . |
| 49 | S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified. |
| 50 | S&F for 150 mm long aluminium handles, cast type, anodisedall as specified . |
| 51 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140 mm all as specified. |
| 52 | S&F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture1.40mm and fixed with stainless steel wire staples |
| 53 | S&F for 100 mm long aluminium hinge, cast type, anodised all as specified. |
| 54 | S&F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane. |
| 55 | S&F for 3 mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 Sqm in each pane all as specified. |
| 56 | Hacking out old broken glass (any thicknesss, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as specified. |
| 57 | S&F for 100 mm long hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws |
| 58 | S&F in repair stainless steel cupboard/ cabinet/ drawers handle having a length of 250 mm and shape all as specified and directed. |
| 59 | S&F in repair brass locks 2 levers for cupboard, grade-I of size 65 mm all as specified. |
| 60 | M&L for mild steel TMT bars 10 mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and as specified. |
| 61 | M&L for mild steel TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified. |
| 62 | M&L for formwork to sides and soffits of floor or roof beams, cover slab, shelves including supports, overhangs etc in rough finished surface of concrete all as specified. |
| 63 | M&L for reinforced cement concrete 1:1.5:3 (Nominal Mix) type A-1 using 20 mm graded stone aggregate as in landings, cover slab (for man holes), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces all as specified. |
| 64 | Demolition of reinforced cement concrete of any description roofs, floors (other than ground floors) beams, staircases, landings, chajjas and simillar suspended work all as specified. |
| 65 | S&F for powder coated aluminium (minimum thickness of powder coating 50 microns) sliding type three track (02 glazed shutters and 01 gauzed shutter) window with sliding shutter and frame with and including aluminium grill, 5 mm thick tinted glass and mosquito proofing net as detailed below complete all as specified and directed: -(i) Frame section 91.85 X 31.75 X 1.30 mm, section No. 8758 for top and sides rails and 91.85 X 31.75 X 1.20 mm for bottom rail, section No. 8687. (ii) Shutter for top, bottom and side rails 40 X 18 X 1.50 mm, section No. 8820.(iii) Glass 5 mm thick one side reflective glass and other side visible fixed with rubber gasket and aluminium clips bearing section No. 4407 and necessary handles, tower boltetc. as directed. (iv) Stainless steel wire cloth (v) Filling of gap between wall and aluminium frame with silicon putty to make it proper water tight.(vi) Locking arrangement and providing Namda rope to make the frames air tight. |
| 66 | S&F for powder coated aluminium anodised (minimum thickness of powder coating 50 microns) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/ mtr including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No.) hinges type B-21 100 mm long (2 No.) suitable handle (1 No.) complete all as specified. |
| 67 | S&F for powder coated aluminium anodised (minimum thickness of powder coating 50 microns) door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc all as specified |
| 68 | S&F forpowder coated aluminium (minimum thickness of powder coating 50 microns) frame and shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.all as specified. |
| 69 | S&F for anodised aluminum grill (anodised transparent or dyed to reqd shape according to IS:1868 with min anodic coating of grade AC 15) of approved design/ pattern with approved standard section and fixed to the existing window frame with CP brass /stainless steel screw @ 200 mm center to center including cutting the grill to proper opening size for fixing and operation of handles fixing approved anodised aluminium standard section around the openning all as per requirement and direction of Engineer-in-Charge. |
| 70 | S&F for5.50mm thick sheet glass (tinted/ reflective type) in square each pane all as specified. |
| 71 | S&F in repair 20 mm diaCP curtain rod with fixing brackets, stops, rollers ets all as specified. |
| 72 | M&L for injecting chemical emulsion (dose as per manufacturer specification) for post constructional antitermite treatmentat the junction of wall and floor (in obstruction cases at skirting level) by drilling 12 mm dia of holes at 300 mm center to center all along wall and at point of contact of wood work with masonary / concrete surface by drilling 6mm dia holes at a downward angle of 45 degree at 300 mm center to center all along the contact of wood work with masonary /concrete. Finally it shallsealed with white cement plugging for complete water proofing and reinforcing the holes all as specified and directed by Engineer-in-ChargeNOTE:1. Floor Area of treated room will be measured for payment purpose. Vertical junction/ corners shall be treated to be included in quoted rates for floor area.2. Chemical treatment and process to be adhered as per manufacturer\"s instruction.3. Warranty for minimun 05 years to be provided by the contractor through specialised agency.4. Anti-termite treatment will be carried only by IPCA (Indian Pest Control Association) approved agency. |
| 73 | Supply only 12 mm gypsum board for false ceiling/ walling all as specified |
| 74 | S&F in repair 12 mm gypsum board (605 mm X 605 mm) in ceiling fixed with screw as per manufacturers instructions including anodised aluminium snap grid frame work for false ceiling/ walling including hangers 6 mm dia galvanished iron (upto1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanished iron flat 40 mm x 3 mm size 60 mm long and expansion hold fasteners12.5 mm dia 40 mm long all as specified |