| 1 | Taking down cement plaster of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed. |
| 2 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4, finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 3 | Demolition of old cement concrete (unreinforced) of any discription and in any position not otherwise specially provided for and removing debrish to out side MoD land, complete all as specified and directed. |
| 4 | M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in coping, roof kerbs, mud stops etc including weathering, slightly rounded or chamfered and trading, complete all as specified and directed. |
| 5 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation, mass concrete, filling in etc, complete all as specified and directed. |
| 6 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drain, complete all as specified and directed. |
| 7 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc, complete all as specified and directed. |
| 8 | Add or deduct to item No. 7.00 above for each 25 mm girth or part thereof over or under 30cm, complete all as specified and directed. |
| 9 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 10 | Use and waste of formwork to rough finished concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 11 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, floor and roof slabs and shelves, horizontal or sloping and similar workexc 5cmbutnot exc 10cm wide, complete all as specified and directed. |
| 12 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia,complete all as specified and directed. |
| 13 | M&L for mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia,complete all as specified and directed. |
| 14 | M&L for RCC 1:1.5:3 (nominal mix) type A-1 (using 20mm graded crushed stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 15 | Providing precast RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in cover slab, mild steel flat enclosers duly welded with reinforcement steel including necessary form work, complete all as specified and directed. |
| 16 | Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles and remove debrish to outside defence land, complete all as specified and directed. |
| 17 | M&L for brick work with sub class ‘B’ bricks, old size, straight or curved on plan exc 6m mean radius, built in CM 1:6, complete all as specified and directed. |
| 18 | All as per serial item No. 17.00 here-in-above but except bricks.Note :- Old bricks obtained against dismantling shall be used. |
| 19 | M&L for walling of random rubble, uncoarsed, well bonded, bedded and solidly hearted, built in cement mortar 1:6, complete all as specified and directed. |
| 20 | All as per serial item No. 19.00 here-in-above but except stones.Note :- Old stones obtained against dismantling shall be used. |
| 21 | M&L for stone boulder pitching with square/rectangular shape and minimum 150mm thickness in cement mortar 1:6, complete all as specified and directed. |
| 22 | Dismantling of structural steel work in any description, complete all as specified and directed. |
| 23 | M&L for mild steel framed work for grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 24 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length for drain out rain water, complete all as specified and directed. |
| 25 | M&L for 75mm thick PCC 1:4:8 type D-1 (using 20mm graded crushed stone aggregates) as in floors, sub base of floor etc, finished the surface even abd smooth without using extra cement, complete all as specified and directed. |
| 26 | M&L for machine pressed rubber moulded, manufactured / compacted by vibrating table method precast concrete interlocking coloured paver block, glossy finish, any shape, and size, confirming to IS:15658-2006 of 60mm thickness, M-35 grade with grey cement and pigments, complete all as specified and directed. |
| 27 | M&L for machine pressed rubber moulded, manufactured / compacted by vibrating table method precast concrete interlocking coloured paver block, glossy finish, any shape, and size, confirming to IS:15658-2006 of 80mm thickness, M-40 grade with grey cement and pigments, complete all as specified and directed. |
| 28 | M&L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed. |
| 29 | Providing precast cement concrete 1:2:4 B-1 (using 20mm graded crushed stone aggregates) as in road side kerb stone etc (of any section indicated) with plain fair faces, including chamfers, weathering, throating etc and setting in cement mortar 1:4 complete with joints to match, complete all as specified and directed. |
| 30 | M&L for 10mm thick natural stone finsihed wall ceramic coloured tiles of size 450mmx 300mm x 6-7mm thick (design as approved by GE) as on vertical surfaces such as walls, skirting etc, set and jointed to match the shade of tiles, fixed over & including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 31 | M&L for applying two coats of cement based paint on newly plastered surfaces of walls over a coat of primer including preparation of surfaces, complete all as specified and directed. |
| 32 | M&L for preparation of old concrete surfaces/ plastered surfaces of any description over 10cm girth or width, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 33 | M&L for preparation of new plastered surfaces by using necessary filling compound of Altek/Birla white putty to obtain smooth/even finish with using sand paper and applying two coats of first quality exterior grade wheather proofing acrylic emulsion paint as per manufacturers instructions of any shade and colour over a coat of alkali resistant primer, complete all as specified and directed. |
| 34 | M&L for preparation of new or previously steel surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enemel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 35 | M&L for 450mm bore reinforced concrete pipes, Class NP3, laid and jointed complete with collar, laid in trenches, complete all as specified and directed. |
| 36 | Removing any kind of old or new debris/demolished building material outside A-1 Def land including loading in truck and conveying day to day basis to beyond the lead included in the rates, including loading, unloading and stacking at the destination approved dumping point etc. complete with all lifts and lead outside MD Land to a distance 1 to 2 Km distance, complete all as specified and directed. |
| 37 | Excavating in post holes (or similar holes) each not exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm thick in any type of soil, complete all as specified and directed. |
| 38 | M&L for plain cement concrete 1:3:6 type C-2 (using 20mm graded crushed stone aggregates) as in foundations, foundations for fencing post, filling in and mass concrete, complete all as specified and directed. |
| 39 | M&L for mild steel work for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work, conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 40 | M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde-E- 250) Quality-A, complete all as specified and directed. |
| 41 | S&F 0.50mm thick prepainted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 42 | Surface excavation not exc 30cm deep and averaging 18cm deep and getting out in any type of soil, complete all as specified and directed. |
| 43 | Removing excavated material/ soil to a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point, complete all as specified and directed. |
| 44 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, complete all as specified and directed. |
| 45 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in paidding over RCC roof with using water proofing compound, complete all as specified and directed.Note : - WPC shall be measured and paid separately under respective item. |
| 46 | Supply only liquid water proofing compound. |
| 47 | M&L for 15mm thick rendering on any type of surfaces in CM 1:3, finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 48 | M&L for preparation of surfaces by scrapping and properly cleaning the existing roof treatment in any number of layer upto original RCC roof top surface. Applying first coat fibre reinfocred elastometric liquid water proofing membrane formulated with PU hybird polymers and reinforcing acrylic fibre with sun reflective index (SRI) of 100-110 having minimum elongation of 350%, tensile strength of 2.9 MPs and shall have cracks bridging ability upto 2.5mm and shall resist 10 Bars of hydroelastic pressure reducerurface temperature upto 10 degree celsius with 33% dilution of priming coat. Laying of fibre mesh of 0.3mm thickness weave in leno pattern having 45 Gsm/Sqm and pasting it properly with ovelap of 50mm and allow it to dry. Apply third and final coat undiluted @ 0.45 ltr/Sqm as directed by Engr -in-Charge. |
| 49 | S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. |