| Sl. No. | Item Description |
| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Excavation in trenches in any type of soiln. exc 1.5 mwide and n. exc 1.5 m in depth and getting out for foundation of pole, laying under ground cables etc and getting out complete all as specified and as directed. |
| 3 | Excavation in trenches in soft/disintegrated soil/hard rock exceeding 1.5 mtr wide and n.exe 3 mtr depth including getting out all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in soil complete all as specified and directed. |
| 5 | Removing excavated soil to a distance n. exc 50m and deposited at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 6 | Material and labour for river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as specified in relevant clause of SSR Part I.Note:Punned thickness of sand shall be measured and paid. |
| 7 | Supplying and laying Class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection cover as per IS 5820,laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed. |
| 8 | M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including filling at road cuttings or making pillars for supporting pipe including necessary form work complete all as specified and directed. |
| 9 | M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed. including necessary form work complete all as specified and directed. |
| 10 | Dismantling of LT insulator of any type any size complete all as specified and directed |
| 11 | M&L for shackle type porcelain vitreous white or brown insulator (For LT) working pressure 1100 volts including galvnised mild steel straps of size 31X 3 mm and 12 mm dia insulator bolts, washers and nuts etc including dismantling unserviceable insulator of any size complete all as specified and directed. |
| 12 | M&L for pin type insulator of size 100 mm height, 65 mm diaporcelain vitreous white or brown/green insulator (For LT) for working pressure 1100 volts with one galvanised spindle and two galvanised iron washers and nut including dismantling unserviceable insulator of any size complete all as specified and directed. |
| 13 | M&L for looptype insulator of size 60x90 mm , clearence of hole 16 mm porcelain vitreous white or brown/green insulator (For LT) for working pressure 1100 volts including dismantling unserviceable insulator of any size complete all as specified and directed. |
| 14 | M&L for errection in position including steel tubular swaged poles type 410 SP-31 (09.00 metres long) complete with cast iron base plate, finial taper plug, bolts, nuts, screws and top cover all as specified and including the following:- (a) Excavation in trenches not exceeding 1.5 mtr wide and 2 mtr deep for pole foundation and getting out in soft/ loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exc 25cm thick and disposal of surplus soil to a distance not exc 50 mtrs. (b) Material and labour for providing PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation, 600 X 600 mm cross section planting depth 1.8 mtr for concrete casing the pole upto GL complete all as directed. (c) Material and labour for providing PCC 1:3:6 type C-2, using 40mm graded stone aggregate for plinth block/collar above GL 300 mm high and 450mm dia all as directed. (d) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer including preparation of surface including painting of 30cm wide blue bands 3 Nos. with synthetic enamel paint in alternate layer upto the height of 1.5m above plinth block. (e) Material and labour for writing letter or figures (Block, Roman, italic as Indian) with thick synthetic enamel paint of approved shade not exc height in numbering of pole all as directed. |
| 15 | S& F in replacement stay assembly comprising of galvanised iron stay bow of size 40 cm X14 cm, 20 mm dia & 1800 mm long GI stay rod including excavation, PCC, GI nuts MS stay plate 300 mm X 300 mm X 6 mm, 2 No thimble, 50X6 mm flat iron stay clamp, Steel stay wire 16 mm dia bolts , nuts and washers etc including taking down unserviceablestay assembly of any size complete all as shown in electrical plate No 1 of MES SSR 1991 Part 1 |
| 16 | Dismantling cross arms, bracings, supports, clamps and back plates from existing poles (other than dismantled poles) and pole structures complete. |
| 17 | Fixing only cross arms, bracing, supports, clamps and back plate, obtained from demolition with & including new nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 18 | Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, welding, bending cold or hot,drilling holes for bolts, in any shape or size as directed and inclusive of applying one priming coat and two coats of synthetic enamel paint/aluminium paint including taking down corroded items of any type and size all as specified above complete all as specified and directed. |
| 19 | Supply and fix and stringing of OH electric ACSR conductor of any size fixing to insulator with necessary binding wire of suitable size including taking down unserviceable ACSR conductor of any type and sizecomplete all as specified and directed. Note:- (i) 3% extra will be added to the weight for sagging.(ii) Binding and jointing will not be considered for measurement and all the jumper shall be fixed with minimum 6 pg clamps and the quoted rate shall deemed to be include in the unit rate quoted. |
| 20 | Material and labour replacement of GI cradle guard hexagonal / rectangular with galvanised steel wire of 3.15mm to 4 mm dia including taking down unserviceable GI craddle of any size and type complete all as specified and directed. |
| 21 | Supply and fix galvanised steel continuous earth wire of size4.00 mm including taking down unserviceable GI earth wire of any size and type complete all as specified and directed. |
| 22 | Supply and fix galvanised stay strand wire of size 7/ 4 mm including taking down unserviceable Stay wirewire of any size and type complete all as specified and directed. |
| 23 | Restringing of LT over head line conductor comprising of any size ACSR conductor / GI wire on existing pole after opening from insulator by taking out of binding wire and refixing the same with suitable size of binding wire upto permissible sag after restringing including cutting of tree branches and trimming of smaller branches of any size up to 2 metre each side of OH line which touch/ falling on the OH line without damaging of 4 wire (3 phase and neutral) span exc 25.00m but n. exc 35.00mcomplete all as specified and directed. |
| 24 | All as per Sl. item No. 22 here in above but 6 wire (3 phase, neutral and street light) span exc 25.00m but n. exc 35.00mcomplete all as specified and directed. |
| 25 | M&L for GI tubing, light grade, 50mm dia with all necessary fittings, laid in trenches, under floor/road crossing, fixed on poles for cable protection fixed with the clamps made out of FI 25 x 3mm duly painted with two coats of aluminium paint over a coat of approved primer etc. including taking down old unserviceable any size and capacity of GI pipe complete all as specified and directed. |
| 26 | M&L for GI tubing, light grade, 80mm dia with all necessary fittings, laid in trenches, under floor/road crossing, fixed on poles for cable protection fixed with the clamps made out of FI 25 x 3mm duly painted with two coats of aluminium paint over a coat of approved primer etc. including taking down old unserviceable any size and capacity of GI pipe complete all as specified and directed. |
| 27 | M&LPVC line spacer for LT over head line for 3 wire system complete all as directed Note- Required T&P will be arranged by contractor no extra cost shall be paid) all as specified and directed. |
| 28 | M&L for painting to steel tubular pole with aluminium enamel paint of 9.00 Mtr including cross arms, clamps any size and nuts, bolts etc with one coat of aluminium synthetic enamel paintincluding preparing the surfacesfree from finish particalsand making the smooth surface and numbering on pole with black ground such as pole number and source of supply, painting withradium paint around the pole at width of 10cm, similar three rounds from 1.5 m GL top on circumferance of polecomplete all as specified and directed. |
| 29 | Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed.Notes :1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever.2. The cutting / trimming of tree branches shall be done to atleast 2.00 metre radius of OH line.3. The unit of measurement is \"SPAN\" i.e. distance covered between two poles. |
| 30 | S&F in repair on load change over switch 63 Amps, 4 pole,415 volts50 Hzwith S S enclosure including taking down unserviceable one complete all as specified and directed. |
| 31 | S&F in repair on load change over switch 100 Amps, 4 pole,415 volts50 Hz with S S enclosure including taking down unserviceable one complete all as specified and directed. |
| 32 | S&F off load changeover switch in sheet metal enclosure, heavy duty, 200 Amps, four pole, 415 Volts AC, 50 Hz with side handle including connectins complete all as specified and directed. |
| 33 | S&F off load changeover switch in sheet metal enclosure, heavy duty, 320 Amps, four pole, 415 Volts AC, 50 Hz with side handle including connectins complete all as specified and directed. |
| 34 | M&L for earth continuity conductor or main earthing lead of 32x6 mm galvanised iron strip buried in ground or fixed to wall complete all as specified and diirected . |
| 35 | M&L in replacement of MCCB of follwoing sizes fixed with thermal & magnetic setting with extended terminals,replacement to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unserviceable complete all as specified and directed. |
| 36 | (a) 400 Amp, 4 pole, 415 volts, thermal & magnetic release adjustable type with breaking capacity 36 KA complete all as specified and directed. |
| 37 | (b) 350 Amp, 4 pole, 415 volts, thermal magnetic release adjustable type with breaking capacity 36 KA complete all as specified and directed. |
| 38 | (c) 200 Amp, 4 pole, 415 volts, thermal magnetic release adjustable type with breaking capacity 36 KA complete all as specified and directed. |
| 39 | (d) 160 Amp, 4 pole, 415 volts, thermal magnetic release adjustable type with breaking capacity 36 KA complete all as specified and directed. |
| 40 | (e) 100 Amp, 4 pole, 415 volts, thermal magnetic release adjustable type with breaking capacity 16 KA complete all as specified and directed. |
| 41 | (f) 63 Amp, 4 pole, 415 volts,thermal magnetic release adjustable type with breaking capacity 16 KA complete all as specified and directed. |
| 42 | Supply, laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in wall or passing through pipe, 1100 volts grade heavy dutywith XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor including making input and output connections with using suitable size of thimbles, lugs, and glands complete of following cross sectional area as under including taking down Old unserviceable cable complete all as specified and directed. |
| 43 | (a) 120 Sqmm 3.5 Core |
| 44 | (b) 70 Sqmm 3.5 Core |
| 45 | (c ) 50 Sqmm 3.5 Core |
| 46 | (d) 35 Sqmm 3.5 Core |
| 47 | (e) 25 Sqmm 3.5 Core |
| 48 | (f) 16 Sqmm 4 Core |
| 49 | (g) 16 Sqmm 2 Core |
| 50 | (h) 10 Sqmm 2 Core |
| 51 | S&F in replacement of 1100 volts grade heavy duty cable of size 10 SqmmPVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular all as directed as specifed. |
| 52 | M&L in replacment of 1100 Volts grade, heavy duty cable, PVC insulated copper cable, served with inner sheathing of PVC tape and overall PVC sheathed for hight mast light connection cicrular of size 4 Sqmm three core cable round type stranded conductor complete all as directed incl taking down old unsv complete all as specified and directed. |
| 53 | M&L in replacment of 1100 Volts grade, heavy duty cable, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for street light connections cable flat or cicrular of size 6 Sqmm twin core cable stranded conductor complete all as directed incl taking down old unsv complete all as specified and directed. |
| 54 | Supply, jointing, testing straight through jointing kit heatshrinkable out door type, suitable for LT 1100 Volts grade cable of size 95 Sqmm to 120 Sqmm 3.5 core complete all as specified and directed. |
| 55 | Supply, jointing, testing straight through jointing kit heatshrinkable out door type, suitable for LT 1100 Volts grade cable of size 50 Sqmm to 70 Sqmm 3.5 core complete all as specified and directed. |
| 56 | Supply, jointing, testing straight through jointing kit heatshrinkable out door type, suitable for LT 1100 Volts grade cable of size 25 Sqmm to 35 Sqmm 3.5 core complete all as specified and directed. |
| 57 | Supply, jointing, testing end termination jointing kit heatshrinkable out door type, suitable for LT 1100 Volts grade cable of size 70 Sqmm to120 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 58 | Supply, jointing, testing end termination jointing kit heatshrinkable out door type, suitable for LT1100 Volts grade cable of size 25 Sqmm to 50 Sqmm 3.5 core complete all as specified and directed. |
| 59 | M&L for fixing MS slidinglocking doorbolt of size not less then 12 mm dia, 250 mm length bolt, stove enameled black with bright boltwith staple plateon LT panel doors (forlocking of doors) with min sixnuts, bolts and washersincluding drilling and fixing on site complete all as specified and directed. |
| 60 | S&F butt hinges, heavy weight, cold rolled mild steel, 100mm size duly welded to doors of LT panel board, etc complete all as specified and directed. |
| 61 | S&F in repairs LED indication lamps (RGY) (set of three) complete all as specified and as directed. |
| 62 | Supply and spreading grass killer chemical all around to kill unwanted grass near or below the feeder panel and any E/M installation in 1 Litre bottle with and including cutting/ cleaning of vegetation for spreading chemical complete all as specified and directed. |
| 63 | Cutting of bituminous road/PCC hard standing/road/floor for laying of GI pipe upto 80mm dia (trench not more than 0.3m x 0.3m) for passing of cable including making good the disturbed surfaces in PCC 1:2:4, type B-2 (using 40mm graded stone aggregate) as per existing complete all as specified and directed.Note:-GI pipe shall be measured & paid separately under relevant item. |
| 64 | M&L for servicing/repairing of APFCpanel, any type and size upto 150 KVAR for making them functional by removing and cleaning of dusts, checking control wiring and connections, replacement of any damaged control wire, checkingcapacitors, tightening of all electrical connections and hardware, checking of metering devices, relays, etc. to make the panel functional complete all as specified and directed.Note:- Spare parts required shall be measured paid separately under relevant item. |
| 65 | S&F in repairs capacitor, metalized poly propylene heavy duty (MPPH), three phase, 415 volts, 50 Hz system for permissible non-linear load 15 % of 1 to 5 KVAR capacity to maintain power factor complete all as specified and directed. |
| 66 | S&F in repairs capacitor, metalized poly propylene heavy duty (MPPH), three phase, 415 volts and 50 Hz system for permissible non-linear load 15% of 10 KVAR capacity to maintain power factor complete all as specified and directed. |
| 67 | S&F in repairs capacitor, metalized poly propylene heavy duty (MPPH), three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of 15 KVAR to 25 KVAR capacity to maintain power factor complete all as specified and directed. |
| 68 | Supply and installation of capacitor, metalized poly propylene heavy duty (MPP-H), three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of 25 KVAR capacity to maintain power factor complete all as directed. |
| 69 | Supply and fixing in repairs 3 phase contactor type (MNX 18 to 50) for high mast or capacitor banks etcas per sample including taking down old unserviceable one complete all as specified and as directed. |
| 70 | Supply and fixing in repairs current transformer with CT required CT ratio as per existing sample complete all as specified and as directed. |
| 71 | Supply and fixing in repairs APFC relay set for APFC panel of size upto 150 KVAR capacity including taking down old unservicable one complete all as specified and as directed. |
| 72 | M&L for replacement of factory made RCC precast earthing pit cover chamber of size 400 mm x 400 mm x 300 mm & 65 mm thick complete all as specified and directed |
| 73 | Material & labour for earthinggalvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including galvanized steel strip 32 mm x 6 mm as earth lead upto equipment by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 using 20mm gradded stone aggregate in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion & dismantling of existing earthing, complete all as specified & directed. |
| 74 | Labour only for attending day to day complaints for repairing of street light, security light, post top lantern of any size/ wattage including tighting loose electric connection, carbon deposition and any other minor defects required for its smooth functioning at tech area Taku Itarsi by deputing skilled and qualified electrician alongwith helper at any time of the day as per requirement complete all as specified and directed. Note:- (i) Complaint shall be done within 24 hrs after intimation or receiving reciept of complain slip by JE/ AGE otherwise penalty of Rs 250.00 per day per complaint will be levied on contractor. (ii) Complaints will be reported on daily basis with complaint register. (iii) Other minor items such as insulating tape, screws, small pieces of electrical cables PVC insulated copper multistranded conductor of size 2.5 Sqmm three core upto length of 1.5 m etc as required to attend the complaintis included in quoted rates. |
| 75 | Supply and fix in repair of LED driver suitable for 45-60Watt existing LED security/street lights of any make and model all as specified and directed by Engr-in-Charge . |
| 76 | Supply and fix in repair of LED driver suitable for 70-100 Watt existing LED security/street lights of any make and model all as specified and directed. |
| 77 | Supply and fix in repair of LED driver suitable for120-200 Watt existing LED flood lightof any make and model all as specified and directed. |
| 78 | S&F of integral LED street light fitting of 45 watt, lumen notless than 5000 or 110 lm per watt, auto start efficiency not less than 85 % impact residence not less than IK -08, as per IS-10322 comprising of high pressure die cast aluminum hosing, heat resistant enclosed with glass cover in frame, IP-66 degree protection suitable for high efficient moulded lens operating voltage should be 170 to 230 Volts complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole and testing complete all as specified and directed. |
| 79 | S&F of integral LED street light fitting of 60 watt, lumen notless than 9000 or 125lm per watt , auto start efficiency not less than 85 % impact residence not less than IK 08, as per IS 10322 comprising of high pressure die cast aluminum hosing, heat resistant enclosed with glass cover in frame, IP-66 degree protection suitable for high efficient moulded lens operating voltage should be 170 to 230 Volts complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole and testing complete all as specified and directed. |
| 80 | S&F of integral LED street light fitting of 70/72 watt, lumen notless than 7500 or 125lm per watt, auto start efficiency not less than 85 % impact residence not less than IK 08, as per IS 10322 comprising of high pressure die cast aluminum hosing, heat resistant enclosed with glass cover in frame, IP-66 degree protection suitable for high efficient moulded lens operating voltage should be 170 to 230 Volts complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole and testing complete all as specified and directed. |
| 81 | S&F of integral LED street light fitting of 90 watt, lumen notless than 11300or 125lm per watt, auto start efficiency not less than 85 % impact residence not less than IK 08, as per IS 10322 comprising of high pressure die cast aluminum hosing, heat resistant enclosed with glass cover in frame, IP-66 degree protection suitable for high efficient moulded lens operating voltage should be 170 to 230 Volts complete with fixing arrangement, nuts, washers, bolts, clamps including electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole and testing complete all as specified and directed. |
| 82 | S&F of integralLED flood light fitting of 100 Watt, 230 V AC high efficiency as per IS- 16107, IP-66 degree of protection comprising of epoxy powder coated housing enclosed with glass cover in frame, impact and corrosion resistant with driver and lamp complete with fixing arrangement, nuts, washers, bolts, clamps including making electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole and testing complete all as specified and directed. |
| 83 | S&F of integralLED flood light following 120 watt, 230 V AC high efficiency as per IS- 16107, IP-66 degree of protection comprising of epoxy powder coated housing enclosed with glass cover in frame, impact and corrosion resistant with driver and lamp complete with fixing arrangement, nuts, washers, bolts, clamps including making electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole and testing complete all as specified and directed. |
| 84 | S&F of integral LED flood light following 150 watt, 230 V AC high efficiency as per IS- 16107, IP-66 degree of protection comprising of epoxy powder coated housing enclosed with glass cover in frame, impact and corrosion resistant with driver and lamp complete with fixing arrangement, nuts, washers, bolts, clamps including making electric connection with 2.5 Sqmm PVC aluminium stranded conductor 3 core upto required length on pole and testing complete all as specified and directed.Note for item no 65 to 71:- Contractor shall produced manufacture test certificate and warrenty card for repair/replacement for 3 Years. |
| 85 | S&F in replacement for GFS polycarbonate thermoplastic oval shape weather proofjunction boxes IP-65, with internal embedded polyurethane material gasket, IK-09 as per IEC 60695-2-11 for street lights of size not less than 210 x 155 x 102 mm with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals of rating 32 Amps for three phase and neutral, mounted with locking arrangement and fixed to the PCC/steel poles by means of suitable size of clamps, nuts and bolts with and including provn for 01 no, single pole MCBs 6-32 Amps, 10KA complete all as specified and directed. |
| 86 | S&F in replacement GI pipe 50 mm dia, medium grade 1.75 m length brackets for mounting light fitting, bent to shape as required and fixed with two Nos of MS clamps set, nuts, bolts, washers including applying two coats of aluminium paints over one coat of zinc oxide primer on clamps complete all as specified and directed. |
| 87 | S & F aluminum lugs suitable for aluminum cable of size 16 Sqmm complete all as specified and directed. |
| 88 | S & F aluminum lugs suitable for aluminum cable of size 35 Sqmm complete all as specified and directed. |
| 89 | S & F aluminum lugs suitable for aluminum cable of size 50 Sqmm complete all as specified and directed. |
| 90 | S & F aluminum lugs suitable for aluminum cable of size 70 Sqmm complete all as specified and directed. |
| 91 | S & F aluminum lugs suitable for aluminum cable of size 95 Sqmm complete all as specified and directed. |
| 92 | S & F aluminum lugs suitable for aluminum cable of size 120 Sqmm complete all as specified and directed. |
| 93 | S&F in replacement timer switch (light sensor type nature switches), three phase of plastic body, degree of protection conforming to IP-54, operating illumination level for switching ON should be less than 60 lux for 30 seconds and for switching off must be greater than 10 lux for 30 seconds, multiple option switch for automatic and manual operations, capable to handle lightning load up to 8 KW including MCB of capacity 63 Amps conforming to IEC-60898 and IS-8828, power contactor of capacity 40 Amps conforming to IEC 60947-4-1, IS 13947-4-1 completely enclosed with plastic body panel conforming to IP-54 degree of protection after taking down the burned control gears and cleaning the existing mild steel panel board duly painted with two coats of epoxy coloured spray paint complete all as specified and directed.Make : Model NoSWADEEP- 02EC8KW1P of Kakatiya Energy systems Pvt Ltd,or equivalent make in Havells/ Legrand / ABB / Schneider |
| 94 | S&F in replacement synthetic rubber insulation mats of size 2mtr x1mtr x 2.5mm thick for insulation for LT panels, transformer or DG Set complete all as specified and directed. |
| 95 | M&L MCB, SP 6 A -32 Amp, Curve C,240 V, 10 KA complete all as specified and directed by Engr-in-charge. |
| 96 | Supply and fix in replacement cable pvc insulated and pvc sheathed of size 2.5 Sqmm three core stranded Copper conductor complete all as specified and directed . |
| 97 | Supply and fix in replacement maintenance freerechargeable battery 12 V, 100 AHtubular type with initial chargingcomplete all as specified and directed . Note: Contractor shall produced warrenty card for repair/replacement for 3 Years |
| 98 | S&F of integral solar light fitting, 20 Watts, highly efficient not less than 90 %, degree of protection IP-65 built in high efficiency solar panel approved by MNRE, LED highly brightness high power light and long life lithium iron battery including BIS certified rechargeable cell with display showing for battery charging full charge, low voltage with different colour LED lamp with high efficiency microprocessor based charge controller and motion sensor, automatic dusk to dawn operation ,the luminaire shall have specially designed for pole mounting piece that enabled lateral as well as post top mounting and installation at varying tilts from 0 to 15 degree for optimal light distribution, mounting pole shall be 6 mtr long and making electric cable connection for smooth functioning of solar lights including testing complete all as specified and directed. |
| 99 | M&L for comprehensive maintenance for preventive and periodically maintenance and attending breakdown for electrically over head travelling crane (EOT crane - 01 No.) of capacity 5 Ton, hand operated single girder of make M/s Cranex Ltd located bldg No 211 of Bofors Shed at Tech area Taku, maintenance comprising for servicing and routine maint of longitutinal travel/ cross travel/ assembly system and checking/ lubricating of gear pully/ brake system for proper tightness, checking of housing pulley/ hock and lubricaing hoist steel wire rope for cut abberation, cleaning up all grease/clipping materials, checking functioning of limit switches, motor with cupling and bracks, control panel, etc; checking and inspecting all foundation structure, load test of hooks, snatch and rope, level of gear box oil with and including minor spare parts if reqd shall be replaced i.e gasket, nuts, bolts, washer, lubricating oiling, greasing, etc; and applying two coats of synthetic enamel paint to complete system and writing SM No, machine No, make, date of installation & capacity (one within contract period), all other remaining items to be checked if necessary and replacement of worn out parts timely for safe and satisfactory running of crane complete all as specified and directed.Notes: (i) Spares parts required for crane will be measured and paid seperatly under respective item. (ii) Contractor will carry out comprehensive maintenance once in a month and also to attend complaint in case of break down on emergency basis as and when intimated by the JE E/M or Engr-inCharge. (iii)Contractor will ensure serviceability and safety of crane during his each visit by way of maintaining job card duly signed by JE E/M and will provide safety certificate once in entire contract period from a competent authority i.e Safety Offr deputed by State Govt or Central Govt.(iv) If contractor is failed to attend break down or complaint within two days from date of receipt of complaint, a penalty will be imposed @ Rs. 2000.00 per day. |
| 100 | All as per item No 84.00 here in before but HOT Crane 3 Ton capacity bldg No 92Mortor shed at Tech area Taku of CPE Itarsi Make M/s Morris Engg Co Ltd. |
| 101 | M&L for comprehensive maintenance for preventive and periodically maintenance and attending breakdown for electrically over head travelling crane (EOT crane - 01 No.) of capacity7.5 Ton of make M/s Vishal Cranex (P) Ltd located at Bofors Shed bldg No 211 at Tech area Taku, maintinance comprising for servicing and routine maint of longitutinal travel/ cross travel for frequent reversing/ acceleration as well as break, power panel, fuse switches of electric control system, limit switches for hoisting lowering trolley and coupling unit travel track, base plate, gear wheel/ housing assembly system, checking/ lubricating and testing of gear box assembly/ break pully system for proper tightness, hoist steel wire rope for cut abberation, cleaning up all grease/clipping materials for its safe operation, setting right and replacement of damaged wiring of electrical system in PVC trolly cable outside cabin & main switches to control panel, inspecting/checking, decarbonizing and tightening of electrical connection in complete system, setting and tightening the same as per their capacity, checking functioning of limit switches, motor with cupling and breaks, control panel, all foundation structure, load test of hooks, snatch and rope, gear box oil level and replacing minor spare parts if reqd i.e gasket, nuts, bolts, washers, oiling/greasing etc; and applying two coats of synthetic enamel paint to complete system (once within contract period), writing SM No, Machine No, Make, Date of installation & capacity and all other remaining parts to be checked if necessary and replacement of worm out parts complete time to time for safe and satisfactory run of crane complete all as specified and directed.Notes: (i) Spares parts required for crane will be measured and paid seperatly under respective item. (ii) Contractor will carry out comprehensive maintenance once in a month and also to attend complaint in case of break down on emergency basis as and when intimated by the JE E/M or Engr-inCharge. (iii)Contractor will ensure serviceability and safety of crane during his each visit by way of maintaining job card duly signed by JE E/M and will provide safety certificate once in entire contract period from a competent authority i.e Safety Offr deputed by State Govt or Central Govt.(iv) If contractor is failed to attend break down or complaint within two days from date of receipt of complaint, a penalty will be imposed @ Rs. 2000.00 per day. |
| 102 | All as per item No. 86.00 here-in-before but HOT/EOT hoist crane 5 Ton capacity at bldg No 61 & Barrel shed & Eqpt store at Tech area Taku of CPE Itarsi of Make: M/s Morris SWL Safex. |
| 103 | All as per item No. 86.00 here-in-before but HOT/EOT hoist crane 3 Ton capacity at bldg No 64, Barrel cleaning shed bldg No 65, Gun shed at Tech area Taku of CPE Itarsi of Make: M/s Morris SWL Reva. |
| 104 | S&F of gear pully suitable for 7.5 Ton capacity EOT crane (complete set), ISI marked complete all as specified and directed. |
| 105 | S&F of gear pully suitable for 5 Ton capacity HOT host crane (complete set), ISI marked complete all as specified and directed. |
| 106 | S&F of gear pully suitable for 3 Ton capacity HOT host crane (complete set), ISI marked complete all as specified and directed. |
| 107 | S&F of bearing set suitable for 5 Ton capacity HOT host crane (complete set), ISI marked complete all as specified and directed. |
| 108 | S&F of bearing set suitable for 3 Ton capacity HOT host crane (complete set), ISI marked complete all as specified and directed. |
| 109 | S&F of bearing set suitable for 7.5 Ton capacity EOT crane (complete set), ISI marked complete all as specified and directed. |
| 110 | M&L for removing the motor from EOT crane of 7.5 Ton capacity and rewinding the same with high class enameled copper wire of the appropriate gauge and insulating materials and refixing the motor in existing position complete all as specified and directed. |
| 111 | M&L for removing the motor from HOT hoist crane 3 Ton capacity and rewinding the same with high class enameled copper wire of the appropriate gauge and insulating materials and refixing the motor in existing position complete all as specified and directed. |
| 112 | M&L for removing the motor from HOT hoist crane 5 Ton capacity and rewinding the same with high class enameled copper wire of the appropriate gauge and insulating materials and refixing the motor in existing position complete all as specified and directed. |
| 113 | S&F of limit switches of existing make ofHOT hoist crane 3 Ton capacity complete all as specified and directed. |
| 114 | S&F of limit switches of existing make ofHOT hoist crane 5 Ton capacity complete all as specified and directed. |
| 115 | S&F of limit switches of existing make of EOT crane 7.5 Ton capacity complete all as specified and directed. |
| 116 | M&L for replacement of existing damaged gear wheel (full set) of EOT crane 7.5 Ton capacity complete all as specified and directed. |
| 117 | M&L for replacement of existing damaged gear wheel (full set) of HOT hoist crane 3Ton capacity complete all as specified and directed. |
| 118 | S&F of push button suitable for HOT hoist crane 3/5 Ton capacity complete all as specified and directed. |
| 119 | S&F of push button suitable for EOT crane 7.5 Ton capacity complete all as specified and directed. |
| 120 | M&L for replacement damaged base plate of HOT hoist crane 3 Ton capacity complete all as specified and directed. |
| 121 | M&L for replace the damaged base plateof EOT Crane 7.5 Ton capacity all as specified and directed. |
| 122 | Supply & replace hoist steel wire rope 10 mm dia for 3 to 7.5 Ton capacity Hoist/ EOT/HOT Craneall as specified and directed. |
| 123 | S&F in replacement damaged fuse switches of HOT hoist crane 3 Ton capacity complete all as specified and directed. |
| 124 | S&F in replacement damaged fuse switches of HOT hoist crane 5 Ton capacity complete all as specified and directed. |
| 125 | S&F in replacement damaged fuse switches of EOT crane 7.5 Ton capacity complete all as specified and directed. |
| 126 | M&L for sevicing and comprehensive maintenance for operationaly fit to run DG set of 30 KVA, 3 phase, 415 Volt, 50 HZ AC supply and alternator of make Kirloskar, coupled with diesel engine set at borewell, Adm area, CPE station complete with and including checking lubricating system, toping up lubricant at desired level, replacement of gasket insulation paper sheet glass sleeve of connecting leads, binding the loose coils with binding cloth, nuts, bolts and washers, split pins for proper tightness, cleaning up all filter (if reqdreplacing air filter, fuel filter, oil filter), grease/clipping materials for its safe operation, cleaning the startor, excitor coil and cleaning the complete assembly by taking out perished glass sleeve, insulation paper, binding cloth and washing with carbon tetra chloride, decarbonising and cleaning the rotor etc complete all as specified and directed.Notes: (i) Minor spare parts if reqd to be replaced i.e gasket, nuts, bolts, washers, rod push, clamp hose, control safety, control vernier, oiling, greasing etc are included in unit rate quoted by the contractor. (ii) Spare parts required for DG set/ alternator will be measured and paid seperatly. (iii) Contractor will carry out comprehensive maint once in a month and also attend to any type of break down on emergency basis as and when intimated by JE E/M or Engr-in-Charge. |
| 127 | All as per item No. 111.00 here-in-before but for 30 KVA capacity at Pump house taku area CPE, Itarsi. |
| 128 | All as per item No. 111.00 here-in-before but for 62.5 KVA capacity at main substation CPE, Itarsi |
| 129 | All as per item No. 111.00 here-in-before but for 62.5 KVA capacity at Pump house Taku CPE, Itarsi |
| 130 | M&L for sevicing and comprehensive maintenance for operationaly fit to run DG set of 82.5 KVA of make: Kala Genset, 3 phase, 415 Volts, 50 HZ AC supply alternator of make: Kirloskarcoupled with diesel engine set at Proof House with and including checking lubricating system, toping up lubricant at desired level, replacement of gasket insulation paper sheet glass sleeve of connecting leads, binding the loose coils with binding cloth, nuts, bolts and washers, split pins for proper tightness, cleaning up all filter (if reqdreplacing air filter, fuel filter, oil filter), grease/clipping materials for its safe operation, cleaning the startor, excitor coil and cleaning the complete assembly by taking out perished glass sleeve, insulation paper, binding cloth and washing with carbon tetra chloride, decarbonising and cleaning the rotor etc complete all as specified and directed.Notes: (i) Minor spare parts if reqd to be replaced i.e gasket, nuts, bolts, washers, rod push, clamp hose, control safety, control vernier, oiling, greasing etc are included in unit rate quoted by the contractor. (ii) Spare parts required for DG set/ alternator will be measured and paid seperatly. (iii) Contractor will carry out comprehensive maint once in a month and also attend to any type of break down on emergency basis as and when intimated by JE E/M or Engr-inCharge |
| 131 | S&F of seal thermostat suitable for 30 to 82.5 KVA genset complete all as directed. |
| 132 | S&F of thermostat suitable for 30 to 82.5 KVA genset complete all as directed. |
| 133 | S&F of coolant for genset complete all as directed. |
| 134 | S&F of hose pipe set of any size and capacity genset complete all as directed. |
| 135 | S&F of engine oil of any grade suitable for existing genset complete all as directed. |
| 136 | S&F of belt - V of any size and capacity for genset complete all as directed. |
| 137 | S&F of air filter cleaner kit suitable for 30 to 82.5 KVA genset complete all as directed. |
| 138 | S&F of manifold fuel drain kit suitable for 30 to 82.5 KVA genset complete all as directed. |
| 139 | M&L for PVC line spacer for LT over head line for 2 wire system complete all as specified and directed.Note- Required T&P will be arranged by contractor and no extra cost shall be paid. |
| 140 | Supply and Fix of MS clamp on steel round pole or PCC pole as per existing, for holding GI Pipe of size from 40 mm upto 100 mm carrying XLPE aluminium cable, complete including fixing of nuts and bolts etc. duly painted with aluminium enamel paint to prevent rusting all as specified and directed |
| 141 | S&F of tricolor LED strip/rope light, IP 65 protection, Voltage Surge Protection of 4kV, wide operating voltage range (140V-280V), 15000 hours functioning life under normal conditions, 18 mtr length connecting to OH line or MCB etc in LT poles complete with driver, PVC insulated copper cable 2 core, 1.5 sqmm upto 1.5 mtr for connection as per requirement with proper insulation complete all as directed.Note: Contractor shall produce warranty card for repair/replacement for 2 Year. |
| 142 | Supply and fixing LT RCC precast route marker of size 650x300x100 mm with steel (TMT Bar) user of 8 mm and 6 mm as per IS 1255 complete all as specified and directed. |
| 143 | M&L for earthing complete in replacement ( CPRI tested) 76MM outer dia X 3 mtr length zink coated ( 80-100 microns ) high quality GI pipe 3.2MM minimum thickness, filled with conductive crystalline compound, fitted with from top to bottom inside with 50 X 6 X 3100MM GI strip with terminal 2 hole of 12MM each with SS / BRASS nuts bolts ( CPRI tested with 20KA per 1 sec to peak current 50KA ) with high grade advanced compound (NABL & IEC 62561-7 TESTED ) eco friendly maintenance free earthing compound to enhance soil conductivity packed in eco-friendly HDPE laminated paper bags. 25Kgs x 2 paper bag. ( 0.19 OHMSper mtrs ) including concrete /RCC earthpit inspection chamber width : 320 mm x 320 mm, height : 192 mm, weight : 30 Kgs, load bearing capacity : 5000 Kgscomplete all as specified, including testing and commissioning complete all as directed. Note : - (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, Conductive compound common salt & charcoal dust, Pit chamber, cover, Funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc.(b)The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode. Make: Tirumala Earthing or any other make approved by Command. |
| 144 | Deduct Schedule of credit (calculation will be done off line) Rs. 52860.00 |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail