| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 2 | Demolition of Cement Concrete (unreinforced) of any description andin any position not otherwise specifically provided for, complete all as specified and directed. |
| 3 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar , incl all quions, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 4 | Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1 1:3:6 (20 mm graded aggregate ) and setting in mortar CM 1:6, complete. |
| 5 | M&L for concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete all as specified and directed. |
| 6 | Removing building materials etc. to a distance of 5 Km out side MoD/Unit land including loading, unloading and stacking at the destination etc. complete all as direction of Engineer-in-charge, |
| 7 | Material and Labour for PCC (1:2:4) type B1 using20 mm graded stone aggregate as in coping, mud stops, benching, water tank platform etc.on roof, chajja weathering, slightly rounded or chamfered angles and throatingetc. including necessary form work complete as directed. |
| 8 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:4 etc complete all as specified. |
| 9 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc.. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 10mm thick rendering on brick work or concrete surfaced wall as backing coat of cement mortar 1:3 all as specified. |
| 10 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) and boarding any thickness, including cover fillets and removal out side of MoD land/Air Force Unit area without paying any extra etc. complete all as specified and directed. |
| 11 | S&F false ceiling grid of size 600 x 600 mm system using hot dipped galvanized steel section with precoated capping, main tee of size 24x32 mm having 0.27mm thick at every 1200mm centre to centre, cross tee of size 24x27 mm having 0.25mm thick at 600mm centre to centre and wall angleof size 19x19 mm having 0.35 mm thick fixed to the periphery of the wall, and suspended at every 1200mm centre to centre in both directed using 2.00 mm thick GI wire and fixing 600 x 600 x 16 mm mineral fibre tegular edge ceiling tiles of RH90 complete all as specified and as directed. |
| 12 | Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters(Without taking off shutters from the frames). |
| 13 | S&F Powder Coated aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified Note: Glass will be measured and paid seperately. |
| 14 | S&F powder coated anodised alluminium door shutters, aluminium sections weighing 0.55 Kg/m including joining cleats glazing clips, rubber neoprene packing , handle 2 Nos in each door, hinges, anodised aluminium snap, mortice lock, beading screws, bearingsetc. complete all as specified and as directed by Engr-in-Charge. |
| 15 | S&F Powder Coated aluminium window and ventilator shutters (minimum thickness of powder coating 50 micron)fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. Note: Glass will be measured and paid seperately. |
| 16 | Provision of 5.5 mm thick tinted glass exc 0.5 sqm of each pane of superior quality fixed to alluminium frame works with rubber beadings including solar control film of 25 micron reflective type sicked to glass panes as per instructions of manufacturers Complete all as specified and as directed by Engr-in-Charge. |
| 17 | S&F for 12mm thick prelaminated particle board for insulation purpose, fixed to aluminium framework, complete all as directed by Engr-in-Charge. |
| 18 | S&F Aluminium (Extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as directed by Engr-in-Charge. |
| 19 | M&L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed etc. complete. |
| 20 | S&F Floor door stopper 150mm length of cover plate aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in doors , complete all as specified and directed. |
| 21 | S&F in repairs Aluminium Mortice lock of4 levers in vertical type ofsize 100 mm |
| 22 | Rendering rendering10mm thick cement plaster in CM 1:6 on fair faces brick work or concrete surfaces and finishing the surface even & smooth without using extra cement |
| 23 | M&L for preparation of Old surface of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint including one coat of Birla white putty on plastered surfaces etc including complete removal of existing surfaces of any etc. complete all as specified. |
| 24 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tappingscrews as specified |
| 25 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tappingscrews as specified |
| 26 | S&F Steel work in tubular trusses including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, Complete all as specified and directed. |
| 27 | S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment as in gusset plate conforming ot Fe- 410-W-(Gde-E-250) quality A etc complete. |
| 28 | Preparation of new surfaces of steel and iron surface of any description, not otherwise descriped over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified |
| 29 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 30 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting outin hard/dence soil complete all as specified and directed. |
| 31 | M & L for broken stone or boulders hard core of gauge n exc 63mm deposited spread and leveled in layers n.exc 15 cm thick watered and rammed to true surface complete all as specified and directed. |
| 32 | M&L for75 mm thickPCC 1:4:8(40 mm graded aggregate)type D2 as in sub- base of floor complete all as specified and directed. |
| 33 | M&L for sand filling under floor or in foundation including watering & consolidation complete all as specified and directed. |
| 34 | M&L pre polished Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Gradewith grey cement and no pigment complete all as specified and directed. |
| 35 | M&L for 20 mm thick screed bed CM (1:4) or bedding layer of mortarfor laying floor finishes all as specified and directed. |
| 36 | M&L rubber moulded chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, With grey cement with no pigment jointed and pointed in neat cement slurry in floorsall as specified and directed. |
| 37 | Rendering 15mm thick cement mortar in 1:4 onstone masonry surfaces or surface other than fair face of brick-work or on one side of lathing without using extra cement. |
| 38 | M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paintcomplete all as specified |
| 39 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed. |
| 40 | Dismantling barbed wire fencing of any description |
| 41 | Excavating in postholes in Hard/dense soil (or similar holes) each n.exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm, watering and removing surplus soil to a distance n.exc 50 mtr & making good surface getting out in all as specified and directed. |
| 42 | M&L Cement concrete1:3:6 Type C-2 (40 mm graded crushed stone aggregate) in foundation filling and mass concrete complete all as specified and directed |
| 43 | S&F for angle iron posts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer - in - charge. |
| 44 | Supply only chain link MS galvanised fencing any size or type , complete all as specified and directed by Engineer - in - charge. |
| 45 | Fixing only chain link fencing including line wires,, any mesh, size and type to any type of standards, rails, straining bolts,welding work required etc. including provision of binding wire, complete all as specified and directed by Engineer - in - charge. |
| 46 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil, complete all as specified and directed. |
| 47 | M&L for PCC 1:3:6, type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed. |
| 48 | S&F Structural steel worksas roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc conforming to Fe-410-W (Gde-E-250) quality A, Complete all as specified and directed. |
| 49 | M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentComplete all as specified and directed. |
| 50 | M & Lfor CNC Cutting, or Computer Numerical control cutting of Approveddigital design and powder coating paint of 100 microns thick on both sides in sheet size 1250 x 2500 x 5 mm thick MS plate fixed in steel frame with nut and bolt all as specified and directed by Engr- in- incharge.Note:- MS plate and Steel frame are measured and paid separately. |
| 51 | M&L for painting new steel surfaces of any description incl preparation, priming with red oxide zinc and two coat synthetic enamel paint, width or girth over 10cm, not otherwise described, complete all as specified and directed. |
| 52 | M&L for pre cast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) block masonary with solid block exc 10 cm width and setting in CM 1:6 complete all as specified. |
| 53 | M & L for rendering 10 mm thick in cement mortar 1:6 on brick or concrete surfaces finished even and smoothwithout using extra cement all as specified and as directed. |
| 54 | M & L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillers, windows-cill, outdoor platform and like in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with of pigment to match with shade of granite etc., including 20mm screed bed in CM1:4 all as specified and as directed. |
| 55 | M & L for Surface excavation n.exc(not exc) 30 cm deep and averaging 15cm deep and getting out in soft loose soil |
| 56 | M&L for pre cast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) block masonary with solid block exc 10 cm width and setting in CM 1:6 complete all as specified. |
| 57 | M & L for rendering 10 mm thick in cement mortar 1:6 on brick or concrete surfaces finished even and smoothwithout using extra cement all as specified and as directed. |
| 58 | Material and Labour for pre cast cover slab using PCC (1:2:4) type B1 and set in CM 1:6 with top surface finished even & fair complete all as specified. |
| 59 | Material and Labour for TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally or hoping for columns, hooking ends & binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips. |
| 60 | M & L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillers, windows-cill, outdoor platform and like in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with of pigment to match with shade of granite etc., including 20mm screed bed in CM1:4 all as specified and as directed. |
| 61 | M&L for concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete all as specified and directed. |
| 62 | M & L for sand filling pathway in layers n. exc 30cm thick, including watering and consolidation as directed |
| 63 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and nopigment laid over and including machine compacted sand cushion all as specified and directed.etc complete. |
| 64 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), includingmaking joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), includingmaking drainage opening wherever required complete. |
| 65 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil, complete all as specified and directed. |
| 66 | M&L for PCC 1:4:8, type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed. |
| 67 | M&L for PCC 1:3:6, type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed. |
| 68 | S&F Structural steel worksas roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc conforming to Fe-410-W (Gde-E-250) quality A, Complete all as specified and directed. |
| 69 | M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentComplete all as specified and directed. |
| 70 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specifed and directed by Engineer-in-charge. |
| 71 | S&F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specifed and directed by Engineer-in-charge. |
| 72 | M&L for painting new steel surfaces of any description incl preparation, priming with red oxide zinc and two coat synthetic enamel paint, width or girth over 10cm, not otherwise described, complete all as specified and directed. |
| 73 | M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes ,metal frame,cover plateof suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specifiedand directed by Engr -in -charge for One light point / one bell point controlled by one, one way switch. |
| 74 | All as per item No 73 above but, One fan point /Exhaust Pointcontrolled by one switch |
| 75 | All as per Item No 73 above butfor One 3 pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 05/06 Amps switch |
| 76 | All asper Item No 73 above butfor One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one, one way 05/06 Amps switch |
| 77 | M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc,including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size continuousearth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for one 15 /16 Amps socket outlet point on independent |
| 78 | M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size ofrigid non metallic PVC conduit pipe,concealed and accessories on surface wall/floors/ with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed.NOTE :- Tworuns of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length. |
| 79 | M&L for sub main wiring,complete with 4 runs of 6 sqmm, PVC insulated, unsheathed FRLS cable,1100 volts grade,multi stranded with copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/wall/ roofetc. with two runss of PVC insulated, 4 sqmm FRLS cable, copper conductor for earth continuity conductor all as specified and as directed. |
| 80 | Supply and fix Ceiling rose 3 terminal 5 Amps 230 volts PVC/ Polycarbonate, insulated body. |
| 81 | S & F electronic fan regulator modular type, 2 module, 120Wincluding complete all as specified and directed. |
| 82 | Supply and fixmodular switch 6 Amps 1 way one modulecomplete. |
| 83 | Supply and fixmodular switch of 16 Amps single module complete |
| 84 | Supply and fixmodular socket 6 Amps three pin socket two module complete. |
| 85 | Supply and Fix modularsocket 16 Amps three pin socket four module complete. |
| 86 | Supply and fix MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed. |
| 87 | Supply and Fixing MCBSP 6 - 32 Amps complete all as requiredand directed. |
| 88 | Supply and Fixing MCBSPN 32Amps complete all as requiredand directed. |
| 89 | M/L for providing earthing with GI earth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth strip of 25x4mm by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover 50mm thick with 6mm dia MS bars, 75 mm c/c, complete all as shown in SSR Pt - 1 electrical plate No 3.Note :Note :Unit rate Qoted isdeemed to include the cost or excavation and earth work, RFR, Removal in any type of soil, PCC Chamber, funnel cover etc complete. |
| 90 | M & L Earth continuity conductor or main earthing lead, galvanised iron strip 25 x 4 mm fixed to wall on batten or recess or chases or buried in ground or draw in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etccomplete, as required. |
| 91 | S&F Celing Fan complete with blades , down rods ,elcetrinic regulator and acessories , 230 volts, 1200 mm sweep , min air delevery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed. |
| 92 | Supply and fixing in repairs 36W LED Fitting, 2 x 2recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED drivercomplete all as specified including taking down old unserviceable fittings.Make : Bajaj /CG/Philips/Havells |