| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | M&L for cleanng, disinfection and carefully washing out settled mud, leaves etc from UG Sump of aprrox size 3.6mx4.2mx2.1m in depth internal size of each tank by drainning out complete waste water from tank mannually and by mechanical arrangments, cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush, sludge removal, high pressure cleaning, anti bactrial spray, UV radiation including scrapping out and applying one coat of super qualitylime wash on outer stone wall surface of water tank and one coat blue paint food grade on inner and bottom surface and writing the date of cleaning on the wall of tank on blue base with white colour, including cleaning of the surrounding area of the tank upto a distance of 3 mtrs from the outer edge of tank by cutting of grass, digging out roots, filling holes with earth, levelling of ground and removing waste material to a distance not exceeding 50m complete all as specified and directed. |
| 3 | M&L for cleanng, disinfection and carefully washing out settled mud, leave, algae etc from SWT Tankof aprrox size upto 8m diaX 4m depth internal size of each tank by drainning out complete waste water from tank mannually and by mechanical arrangments, cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush, sludge removal, high pressure cleaning, anti bactrial spray including scrapping out and applying one coat of super quality lime wash on outer stone wall surface of water tank and writing the date of cleaning on the wall of tank on blue base with white colour, including cleaning of the surrounding area of the tank upto a distance of 3 mtrs from the outer edge of tank by cutting of grass, digging out roots, filling holes with earth, levelling of ground and removing waste material to a distance not exceeding 50m complete all as specified and directed. |
| 4 | M&L for cleanng, disinfection and carefully washing out settled mud, bleaching powder residuales, flocculant, etc from swimming pool RCC water UG Sump of Aprrox Size upto 3m DiaX 8m depth internal size of each tank by drainning out complete waste water from tank mannually and by mechanical arrangments, cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush, sludge removal, high pressure cleaning, anti bactrial spray including scrapping out and applying one coat of super qualitylime wash on outer stone wall surface of water tank and writing the date of cleaning on the wall of tank on blue base with white colour; including cleaning of the surrounding area of the tank upto a distance of 3.0 mtrs from the outer edge of tank by cutting of grass, digging out roots, filling holes with earth, levelling of ground and removing waste material to a distance not exceeding 50m complete all as specified and directed. |
| 5 | M& L for PCC demolition of panel of any type any description and in any postion complete all as specified and directed. |
| 6 | M&Lfor plain concrete cement 1:3:6 type C2 using 40mm graded stone aggregate for foundation of poles including necessary form work and PCC demoltion of strut/pole of any description and in any position complete all as specified and directed. |
| 7 | M&L for dismantling the Generator set of 50 KVA by lifting from its existing plinth and taking out from the Generator room by Hydralic Lift/Hydraulic Jacks etc ,setting aside not more than 50m from existing place by lifting and using Hydraulic jack etc carefully without damaging to the Generator and any assests of department, Making arranagments i.e. to keep DG set aside to carry out PCC work as per recommended by OEM including disconnection of all its electrical connections etc and re-installation on the newly made PCC plinth and reconenction its electrical connection etc complete all as specified and directed.Note:- PCC work shall be measured and paid seperately. |
| 8 | M&L for taking down 2 X 10000 Ltr PVC water tank from MES Pump house , transportation and installation at swimming pool by carrying out necessary repair work to tanks if any required including making inter-connection to the tank, tank nipples etc complete all as specified and directed. Note- (i) Earth work and PCC work shall be measured and paid seperately. |
| 9 | M&L for shifting of UPS 7.5 KVA , 415 Volt , 50Hzfrom AHU room to operation theatre 1 to 5 by disconencting its all electrical connection and reconnectingthe same after shifting the same including provision ofUPS wooden trolly of required size alongwith wheels at bottom of the trolley etcincluding minor repairing and servicing complete all as specified and directed. |
| 10 | M&L for wiring for circuit/submain wiring for three phase alongwith earth wire with the following sizes of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing capping of following sizes including taking down existing one complete all as specified and directed by Engr-in-charge:-Note:- Four runs of main wire, one runs of earth wire and one runs of PVC caping will be measured in one. |
| 11 | (a) 4x6.0 sq. mm main wire + 1x6.0 sq. mm earth wire |
| 12 | (b) 4x10.0 sq. mm main wire + 1x10.0 sq. mm earth wire |
| 13 | S & F for battery, 12 Volt from 18 AH, sealed lead acid batteries for UPS back up complete all as specified and directed.Make- Exide/Tata/Amron |
| 14 | Supply and laying M S Pipes heavy grade IS-1239 with all fittings laid in floors or fixed to walls and ceilings etc of sizes as shown , applying red oxide primer and black/green/red paint two coat including taking down existing one alongwith its insulation complete all as specified anddirected |
| 15 | (a) 50mm dia |
| 16 | (b) 65mm dia |
| 17 | (c) 80mm dia |
| 18 | M&L for repairing of AMF Panel repairing of fire fighting generator diesel engine driven pump setof capacity 90 HP, of Fire fighting system including rewiring and replacement of all its defective items like Conatacor, relays, delay timer etc complete all as specified and directed. |
| 19 | S&F in repairs butterfly valve cast iron, PN 1.6, class 125, nominal size 65 mm as per IS 13095: 1991 including taking down existing one by cutting and fixing the new one alongwith fixing of MS pipe not less than 600mm both side of valve and MS flange wherever required complete all as specified and as directed. |
| 20 | S & F in repairs butterfly valve cast iron, PN 1.6, class 125, nominal size 50 mm as per IS 13095: 1991 including taking down existing one by cutting and fixing the new one alongwith fixing of MS pipe not less than 600mm both side of valve and MS flange complete all as specified and as directed. |
| 21 | S & F in repairs butterfly valve cast iron, PN 1.6, class 125, nominal size 80 mm as per IS 13095: 1991 including taking down existing one by cutting and fixing the new one alongwith fixing of MS pipe not less than 600mm both side of valve and MS flange complete all as specified and as directed. |
| 22 | S & F in repairs butterfly valve cast iron, PN 1.6, class 125, nominal size 100 mm as per IS 13095: 1991 including taking down existing one by cutting and fixing the new one alongwith fixing of MS pipe not less than 600mm both side of valve and MS flange complete all as specified and as directed. |
| 23 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe lines, cables, pipes etc in soft /loose soil and getting out complete all as specified and directed. |
| 24 | Returning filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 25 | Removing excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and diected. |
| 26 | M&L for mild steel framed work for made of angle iron and including mild steel sheet as required including necessary welding, cutting, hinges, locking arrangments, flanges for connection of GI Pipes with CI pipes and its nut bolts etc including painting with a coat of synthetic enamel paint over complete all as specified and directed. |
| 27 | M& L for single-headed fire hydrant (landing) valves designed according to IS:5290 Type A standards, featuring a 63mm female instantaneous outlet, a 75mm/80mm flanged inlet, and a 900 LPM flow rate. Made fromstainless steel (SS304), they are tested to 21 \(kgf/cm2) (body) and 14 \(kgf/cm2) (seat), complete all as specified and directed |
| 28 | M&L for double-headed fire hydrant valve (landing valve) is typically specified as Type-B under IS:5290-1993, featuring two 63mm instantaneous female outlets and a 100mm (4-inch) flanged inlet. Constructed from stainless steel (SS304), it handles high pressure with a 21 \(kgf/cm2) body test and 14 \(kgf/cm2) seat test, providing 1800 lpm flow complete all as specified and directed |
| 29 | Supply and fixing illuminated display board of size shall not less than .9M x .3M x .9M (L x B xH) and .15M depthwith flex of light blue( MES Colour) colour of letters shall be white,outerside fabrication bordered with aluminium angle frame of size 35mm x 35mm x 4mm thick, inner side fabricated with 12mm MS square barincluding all internal wirings and illuminated with 2 feet LED 20 W tubelightfitting 02 Nos, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make sintex cat part No GSJB-1414 and written \"AC Plant, AGE E/M Bairagarh, GE Bhopal\",size of letters shall be proportion with overall size of board with electrical connection complete in all respect and electrical connection with PVC insulated 3 core cable not less than 4 running meter complete all as specifiedand as directed. Note : Before manufacturing boards drawing and design of board including colour of board shall be approved by Engr-in-charge. |
| 30 | Supply and fixing illuminated display board of size shall not less than .9M x .3M x .9M (L x B xH) and .15M depth with Flex of Light Blue( MES Colour) Colour of letters shall be white,outerside fabrication bordered with Aluminium angle Frame of size 35mm x 35mm x 4mm thick, inner side fabricated with 12mm MS square barincluding all internal wirings and illuminated with 2 feet LED 20 W Tubelightfitting 02 Nos, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make sintex cat part No GSJB-1414 and written \"Water Filteration Plant, AGE E/M Bairagarh, GE Bhopal\",size of letters shall be proportion with overall size of board with electrical connection complete in all respect and electrical connection with PVC insulated 3 core cable not less than 4 Running meter complete all as specifiedand as directed. Note : Before manufacturing boards drawing and design of board including colour of board shall be approved by Engr-in-charge. |
| 31 | S&F for 80mm dia C.I. dual plated NRV PN 1.6 (DP) CI dual plated Non return valve PN 1.6 alongwith its flanges etc including taking down existing one complete all as specified and directed |
| 32 | All as per ser item no. 25.00 here-in-before but 100mm dia |
| 33 | All as per ser item no. 25.00 here-in-before but 125mm dia |
| 34 | Supply & fixVTPN DB, 4 Way, 415V,50Hz, IP-54 and IK-09, suitable for flush mounting and surface mounting, with 100 A copper busbar for each phase, With 2 neutral bar, 2 earth bar and cable ties for cable management etc, fully insulated busbar & shrouded neutral bars, reversible door , with provision for FP MCB/isolator/RCCB/RCBO as incomer and SP/TP MCB\"s as outgoing cat part No 5077 35 make legrand ,fully reversible, removable chassis and faceplates, includingincluding MCCB4P 40 Amp - 1 Nos C curve 16 KA with thermal magnetic protection unit, thermal adjustable – 0.8 to 1 in, magnetic adjustable** – 5 to 10 in, MCCB3P 25 amp - 2 Nos 16 KAwith thermal magnetic protection unit, thermal adjustable – 0.8 to 1In, magnetic adjustable** – 5 to 10In , including taking down existing one complete all as specified and directed. |
| 35 | M&L for factory made concrete earth pit cover and chamber steel reinforced concrete of size 450x450x300 mm complete all as specified and directed. |
| 36 | M&L for cleanng, disinfection and carefully washing out settled mud, leave, algee etc from SWT tankof Aprrox Size upto 8m X 4m X 2m deptheach tank by drainning out complete waste water from tank mannually and by mechanical arrangments; cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush, sludge removal, high pressure cleaning, anti bactrial spray including scrapping out and applying one coat of super qualitylime wash on outer stone wall surface of water tank and writing the date of cleaning on the wall of tank on blue base with white colour; including cleaning of the surrounding area of the tank upto a distance of 3 mtrs from the outer edge of tank complete all as specified and directed. |
| 37 | M&L for servicing and overhauling of pressure washing machine 5HP Motor 415 Volt, 50 Hz and its piston assembly including taking down alongwith its pipe connection etc including replacement of minor parts like seal, bush, oil ring etccomplete all as specified and directed by Engr-in-charge. |
| 38 | M&L rewinding of copper for 5 HP motor of pressure washing machine 415 volt , 50 Hz complete all as specified and directed by Engr-in-charge. |
| 39 | Supply, Installation, Testing of the Android application, including commissioning, programming, and integration of the existing SCADA system with an SSL-licensed Android-based Smartphone Application, configured and made operational as per the newly allotted static IP address, consisting of a minimum of twenty (20) user interface screens, with user-defined data display, complete in all respects and executed strictly in accordance with the technical specifications, scope of work, approved pipe line drawings, and directions of the Engineer-in-Charge. |
| 40 | M&L for repairing of the existing PLC panel including following repairs:- (1) PLC logic programming and configuration — reprogramming or modification of PLC logic, I/O address configuration, and communication setup between PLC, HMI, and GPRS modem.(2) Component repair and replacement — SMPS, PLC CPU, input/output cards, pressure and flow switches, actuator I/O connections, GPRS modem, HMI, push buttons, LED and RYB indicators, single phase preventer, selector switches, relays, with proper termination and labeling; (3) Panel rewiring and burnt wire replacement — removal of burnt/corroded wires, installation of new control and power wiring with standard color coding, crimping, ferruling, and continuity/insulation testing; (4) Panel inspection and diagnosis — detailed examination of wiring and components, identification of damaged parts, and preparation of replacement list(5) Testing and simulation — dry run testing of all I/O points, verification of actuator operations, pressure/flow switch feedbacks, interlocks, and full simulation of process sequences for final commissioning.Note: Replacement of any defective components, materials such as SMPS, PLC CPU, input/output cards, pressure and flow switches, actuator I/O connections, GPRS modem, HMI, push buttons, LED and RYB indicators etc & items shall be charged and paid separately as per actual requirement. |
| 41 | Supply, Installation, testing of in replacement of PLC CPU , Serial Communication RS232/RS485 x 1, Ethernet Port x 1 and re-wiring of the exisiting panel with respect to the required Inputs & Outputs. |
| 42 | Supply & Fix complete testing of inputs/outputs module for programmable Logic Controller complete all as specified and directedMake :Mitsubishiincluding taking down old unserviceable complete all as specified and directed by Engr in charge |
| 43 | Supply, Installing,Testing and Commissioning in replacement of ultrasonic leveltransmitter at pure water sump ( for measurement of level in pure water ) - including all accessoriescomplete all as specified and directed.Range : 0-5 meters , Accuracy : 0.5 % minimum ,supply voltage : 24V DC,output : 4-20 MA Make:Banner/ Nivelco / Siemens |
| 44 | Supplying , laying, fixing in replacement of wall/ panel/ in trench 1100 Volt grade4 x 1.5 sq.mm. PVC insulated and PVC sheathed armoured copper conductor cable etc complete all as specified and directed. |
| 45 | Supplying , laying / fixing in replacement of wall/ panel/ in trench 1100 Volt grade6 x 1.5 sq.mm. PVC insulated and PVC sheathedarmoured copper conductor cable etc complete all as specified and directed:- |
| 46 | M&L for replacement and completetesting ofRelay with base 4 C/O , 24 V DC including taking down old unsvcomplete all as specified and directed by Engr in charge.Make LEONE/IDEC/L&T |
| 47 | Supply & Fix in replacement with complete testing of Relay with base 4 C/O, 240V ACincluding taking down old unsvcomplete all as specified and directed by Engr in charge. Make LEONE/IDEC/L&T |
| 48 | Supply & Fix in replacement of push button with LED Indicator - 240 V A.C. Colour Red /Green including taking down old unsvcomplete all as specified and directed by Engr-in-charge.Make : ESBEE / TEKNIC/SCHNEIDER |
| 49 | Supply & Fixin replacementwith complete testing buzzer - 240 V A.C. including taking down old unserviceable complete all as specified and directed by Engr-in-charge. Make : C&S / MIMIC/L&T |
| 50 | Supply & fixwith complete testing ofmagnetic Electric motor 230 V, 50 Hz upto 20 RPM suitable for actuator followingsizeincluding taking down old unserviceable and deposited to E/M store complete all as specified and directed by Engr-in- charge.Make: Ritetork/SIEMENS/ABB |
| 51 | 50/80 mm dia |
| 52 | 100 mm dia |
| 53 | 150 mm dia |
| 54 | Supply & Fix in repairswith complete testingof butterfly valvefor thefollowing size complete all as specified and directed by Engr-in-charge. |
| 55 | 50 mm dia |
| 56 | 80 mm dia |
| 57 | 100 mm dia |
| 58 | 150 mm dia |
| 59 | Supply & Fix in repair capacitor for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve including taking down old unserviceablecomplete all as specified and directed. |
| 60 | Supply & Fix in repair resistor for Actuator suitable for50/80/100/150 mm dia motorized Butterfly Valveincluding taking down old unserviceable complete all as specified and directed by Engr-in-charge. |
| 61 | Supply & Fix in repair Limit switch for Actuator suitable for 50/80/100/150mm dia motorized Butterfly Valveincluding taking down old unserviceable complete all as specified and directed by Engr-in- charge. |
| 62 | Supply & Fix in repair SMPS input230 V/AC, Output 24V DC, 5 Amp including taking down old unserviceablecomplete all as specified and directed by Enr-in-charge. Make: NHP/SCHNEIDER/Mean Well |
| 63 | Supply & Fix in repair GPRS Modem complete all as required at site including taking down old unserviceablecomplete all as specified and directed by Engr-in-charge.Make: Schneider Electric, Siemens/ Rockwell |
| 64 | Supply & Fix in repair 9DB Antenna GPRS Modem including taking down old unserviceable complete all as specified and directed by Engr-in-charge.Make: Schneider Electric/ Siemens/ Rockwell |
| 65 | Supply & Fixin repair selector switch including taking down old unserviceable complete all as specified and directed by Engr-in-charge.Make : ESBEE / TEKNIC/TELEMEACHNIQUE |
| 66 | M&Lfor removing old paint from surface ofPLC pannel by scraping, rubbing and making good surface for painting with appling two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 67 | Supply, installation, testing, and commissioning of a microcontroller-based water level monitoring system for three tanks using a single microcontroller-based controller with Wi-Fi communication, comprising fifteen (15) magnetic float level sensors per tank for 25%, 50%, 75%, 100%, and overflow detection, IP65 weatherproof enclosure, SMPS/AC power supply with necessary protection, all internal wiring, terminals, cable glands, and accessories. The system shall provide real-time water level status of all tanks on an Android mobile application, overflow alerts, sensor fault detection, and tank location identification (GPS/fixed location). The complete system shall be delivered as a turnkey solution, ready for operation complete all as specified and as directed. |
| 68 | Supply, installation, and commissioning of IP-67 waterproof magnetic float level sensors for water tanks, dry contact NO/NC output, with cable and terminals, for 25%, 50%, 75%, 100%, and overflow levels and all mounting accessories, fully tested and ready for operation complete all as specified and as directed. |
| 69 | Supply & fix in replacement, testing, commissioning of LT panel board CPRI approved as per IEC-61439, weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet3.15 mm thickouter and 2.00 mm thick for inner door confirming degree of protection IP 66 to with angle iron 50x50x6 mm outoor, floor mounting type with closedaluminium bus bar chamber of size not less than 1.5 times of incommer including necessary insulator suitable for 3 phase, 4 wire 50 Hz AC,CPRI approved including provn of digital ammeter 0-350A,digital voltemeter 0-500 Volts, CT\"s of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 30 cm grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etcThe bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron.(a) MCCB TPN 400 Amps, Icu=Ics 35 KA adjustable type thermal magnetic based release at 415 Volts- 01 Nos (I/C)Make - Lagrend /schinder/seimeus(b) MCCB TPN 100 Amps, 16 KA at 415 Volts- 02 Nos (O/G) Make - Lagrend /schinder/seimeus(c) MCCB TPN 125 Amps, 25 KA at 415 Volts- 02 Nos (O/G) Make - Lagrend /schinder/seimeus(d) MCB TPN 63 Amps, 16 KA at 415 Volts - 01 (O/G)Make - Lagrend /schinder/seimeus(e) MCB SPN 40 Amps, 10 KA at 230 Volts - 02 (O/G)Make - Lagrend /schinder/seimeus(f)Phase indicating lamp RYB neon type (Set of three ) -01 Set (g)VAF+PF Meters , Accuracy class 0.5 |
| 70 | All as per Item No 56.00 here-in-before but LT panel with following specification:- (a) MCCB TPN 400 Amps, Icu=Ics 35 KA adjustable type thermal magnetic based release at 415 Volts- 01 Nos (I/C) Make - Lagrend /schinder/seimeus(b) MCCB TPN 100 Amps, 16 KA at 415 Volts- 01 Nos (O/G) Make - Lagrend /schinder/seimeus(c) MCCB TPN 200 Amps, 25 KA at 415 Volts- 02 Nos (O/G) Make - Lagrend /schinder/seimeus(d) MCCB TPN 63 Amps, 16 KA at 415 Volts - 01 (O/G)Make - Lagrend /schinder/seimeus (e) MCB SPN 40 Amps, 10 KA at 230 Volts - 03 (O/G)Make - Lagrend /schinder/seimeus(f)Phase indicating lamp RYB neon type (Set of three ) -01 Set (g)VAF+PF Meters , Accuracy class 0.5 |
| 71 | Supply and laying synthetic rubber insulated mats 2mm thick for voltage upto 3.3 Kv for electrical purpose as per IS 15652-2006 suitable for electrical shock safety ofsize 1 m x 2 m x19mmcomplete all as specified and directed. |
| 72 | Supply and laying synthetic rubber insulated mats 2mm thick for voltage upto 3.3 Kv for electrical purpose as per IS 15652-2006 suitable for electrical shock safety ofsize 1 m x 2 m x10mmcomplete all as specified and directed. |
| 73 | Supply, installing, testing & comissioning in replacement ofLT outdoor type IP-54 encloscire Timer switch panel upto matri switching of outdoor lighting as a senser & timer with advanced micro controller, single phase, mounted on pole/wall, comprising of following items complete all as specified and directed by Engr-in-Charge.(i) MCB SP 16 Amp, \"C\" Curve, 240 V , 10 KA - 01 Nos.(ii) Contactor 16 Amp, 240 V - 01Nos(iii) Electronic Timer 1 Phase - 01 Nos. |
| 74 | Supply, installing, testing & comissioning in replacement ofLT outdoor type Timer switch Panel, Three phase, Mounted on pole/wall, compressing of following items complete all as specified and directed by Engr-in-Charge.(i) MCB TPN 40 Amp, \"C\" Curve, 415 V , 10 KA - 01 Nos.(ii) Contactor 25 Amp, 415 V - 01 Nos.(iii) Electronic Timer 1 Phase - 01 Nos. |
| 75 | M&L for earthing complete with GI strip as earth lead and MS galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32 x 6 mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40 x 3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame including plastering and white wash, charcoal, common salt 15cm at round the earth plate, watering pipe 20mm med grade/galvanized and 40mm dia GI pipe medium grade for GI strip protectionwith GI funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2020.Notes : Contractor shall be produce test result data sheet, if result not came as required, he has to redone without any extra cost. (i) The unit rate includes for 40mm dia medium grade protection pipe and earth lead upto 7.50 meter. (ii) Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured & paid seperately separately. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional height of watering pipe, bends, elbow etc shall be deemed to be included in the unit rate. |
| 76 | All as per ser item No 62.00 here-in-beforebut using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip asearthing lead all as specified & directed. |
| 77 | M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe orfixed to poles or any other indicated situation for loop earthing etc. as required20x3mm copper strip all as specified and directed. |
| 78 | Supply and fix single pointed air termination aluminum rod, 12mm dia 30 mm long complete all as specified and directed. |
| 79 | S &F aluminum strip 25 x 3.15 mm complete with saddes and fixing screws etc. for roof conductors and down conductors above ground upto test points complete all as specified and directed. |
| 80 | Supply and fix test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed induding 3 nos 8mm dia 25mm longhex head screw complete all as specified and directed. |
| 81 | M &L for cement concrete type C-2 of 1:3:6 using 40mm graded stone aggregate) as in PCC block 30x30x30cm for supporting of aluminum strip on roof induding use of necessary work for rough fisnished surfaces complete all as specified and directed. |
| 82 | M&L for replacement of unserviceable flex sign board made of angle iron frame 25mm x 25mm x 3mm ofsize 8\" x 3\" x 0.5\" complete with words \"MILITARY HOSPITAL 33KV SUB -STATION \"in english including 04 x 18W led light fittings & wiring, complete box covered with aluminum angle frame including fixing and testing complete all as specified and directed. |
| 83 | Deduct Schedule of credit (calculation will be done off line) Rs. 57261.00 |