| 1 | Maintenance and servicing of Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine \"B\" check of the engine complete for smooth functioning all as per manufacturer\"s instructions and directions. Note :- (i) \"B\" check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. The Contractor shall carry out periodical inspections during the maintenance period for the smooth functioning of the DG set once in a month and shall also attend all the maintenance works as and when required. ii) Spare parts, such as engine oil and radiator coolant oil shall be measured and paid separately but cost of labour for filling of oils shall be deemed to be included in the quoted rate.(iii) Cost of all consumables like diesel/oil filter, air cleaner element, radiator cleaning etc or any other items required during the maintenance period shall be deemed to be included in the rate quoted for this item. |
| 2 | 500 KVA DG SetMake Cummins without AMF |
| 3 | 250 KVA DG set Make:- Kirloskar with AMF Panel |
| 4 | 200 KVA DG SetMake Cummins without AMF |
| 5 | 82.5 KVA DG SetMake Kirloskar with AMF |
| 6 | 62.5 KVA DG SetMake Kirloskar without AMF |
| 7 | 40 KVA DG SetMake Kirloskar without AMF |
| 8 | 70 HP IC engine pumpMake Kirloskar |
| 9 | M & L for Taking downradiator fromDG Set of any type /makeof following capcity from base mounting , cleaning /descaling by using of air compressor and cleaning with suitable stain removal detergent along with chemical etc and rectifing water leakage by means of welding / brazing, after cleaning , descaling and rectifing of leakageetc. including renewal of all connecting parts i.e radiatorhose pipe with clamps , bolts, nuts washers , rubber bush packing materal etc and re-assembling the radiatorand fixingwith DG set properly in original position, checking the alignment, making proper hose connecting, testing for smooth operation complete all asdirected . |
| 10 | 500 KVA DG Set+E16:F20 |
| 11 | 250 KVA DG set |
| 12 | 200 KVA DG Set |
| 13 | 82.5 KVA DG Set |
| 14 | 62.5 KVA DG Set |
| 15 | 40 KVA DG Set |
| 16 | 70 HP IC engine pump |
| 17 | Material and labour for taking down of existing fuel from fuel tank of following capacity DG set by any means, removing of sludge and sediments deposited inside the fuel tank by repeatedly washing by using of chemical & detergent with air compressor including rectifing ofleakage if found and refixing the same inposition duly painted by spray painting as per direction of engineer in charge by testing all as specified and directed . |
| 18 | 500 KVA DG Set |
| 19 | 250 KVA DG set |
| 20 | 200 KVA DG Set |
| 21 | 82.5 KVA DG Set |
| 22 | 62.5 KVA DG Set |
| 23 | 40 KVA DG Set |
| 24 | 70 HP IC engine pump |
| 25 | Supply and re-filling of new engine oil( 20 W- 40 grade), sealed drum of (Packing of 210 litrs) Make SERVO OF IOC/HINDUSTAN PETROLEUM/ CASTROL) as approved by GE. .Make: Castrol Super /Hindustan petrollium. |
| 26 | Supply only raditor coolant concentrate.Make:- K- COOL SUPER PLUS/ CASTROL |
| 27 | Supply & Filling of distilled water alongwith coolant as per ratio recommended by OEM incl draining of radiator and removing sludge etc complete all as directed. |
| 28 | Material and labourfor taking out of injector of DG Set of any type/make of following capacity, disconnection and openingof fuel injector assembly , carrying complete overhauling / servicingfuel injector system , including renewal of injector kit , calibrationof injector , checking of pressure complete for each injector and re-assembling the samein original positon by making proper fuel connnection and testing for smooth operation complete all asdirected . |
| 29 | 500 KVA DG Set |
| 30 | 250 KVA DG set |
| 31 | 200 KVA DG Set |
| 32 | 82.5 KVA DG Set |
| 33 | 62.5 KVA DG Set |
| 34 | 40 KVA DG Set |
| 35 | 70 HP IC engine pump |
| 36 | Supply and fixing in replacement of Battery 12volt 150AH/180 AH Make:- Exide /Amaron |
| 37 | Supply and fixing in replacement of Battery 12volt 65/95 AH.Make:- Exide /Amaron |
| 38 | Material and Labour for replacement of unserviceable Battery charger of 12V/24Volt complete in all respect all as directed. |
| 39 | Supply and fixing in replacement of Oil Pressure Sensor suitable for 500 KVA to 750 KVA DG set connecting with panel circuit, starting and testing on load all as specified and directed. |
| 40 | Supply and fixing in replacement of Coolant TempetarureSensor suitable for 82.5 KVA to 250 KVA DG set connecting with panel circuit, starting and testing on load all as specified and directed. |
| 41 | Dismantiling exiting unserviceable 200 LPD/ 500 LPD solar water heating system ETC and re-fixing in its original position after necessary repair/ replacement of unserviceable spares (Evacuated Tube Collector) all as specified and directed.Note : Replacement of spares shall be measured & paid separately under respective items of Sch \"A\". |
| 42 | Material and labour for cleaning of solar water heating system dismantled against item No13above and Servicing of solar water heater system byCleaning complete tubes internally, Anti-scaling Cleaning of all effected parts . Removing any type of chocking of Solar Collector or tube, repairing any type leakage from Gasket,Rubber Washer after Cold Water inletand before hot water outlet of Solar Water Heater with cleaning agent complete all as specified and directed. |
| 43 | Supply andfixing of CPVC pipe line 25mm dia including all type of connected fittings for solar water heating system complete and taking down the same all as specified and directed. |
| 44 | Supply and fixing in repair hot water ,GI pipe line 20 mm dia (heavy grade) duly insulated with glass wool 50mm and aluminum cladding complete all as specified and directed. |
| 45 | Supply and fixing in replacement heating element of capacity of 3 KW, thread type, suitable for solar water heating system complete all as specified and directed.Make:- Theta,Newton,Dashmesh |
| 46 | Supply and fixing in replacement thermostat, suitable for solar water heating system complete all as specified and directed.Make:- Dashmesh,Indofoss,Bajaj |
| 47 | Supply and fixing in replacement silicon washer of size suitable for solar water heating system complete all as specified and directed. |
| 48 | Supply and fixing in repair solar water heating system evacuated tube any size complete all as specified and directed. |
| 49 | Supply and fixing in replacementaganist repairs of solenoid/ shut off valve of capacity 82.5 to 250 DG Sets of existing make along with screen Filterincluding wiring connecting to panel circuit, starting and testing on load complete all as specified and directed. Make: As Per OEM Recommendation |
| 50 | Supply and fixing in replacement of selector switch suitable for 415volts. |
| 51 | Supply and fixing in replacament of LED type phase indicator to be fitted on panel ( R,Y , B as per site requirement) |
| 52 | Supply & fixing in replacment of digital typeVoltmeter 0-500volts with selector switch, 3 phase,complete all as specified and directed. |
| 53 | Supply & fixing in replacment repairs of digital type Ammeter 0-200 Amps with 3 Nos CT coils and selector switch, 3 pohase complete all as speicified and directed. |
| 54 | Supply & fixing in replacment of digital type frequency meter of capacity 0 to 999.90 Hz,panel mountingcomplete all as specified and directed. |
| 55 | Supply and fixing in replacement of the following accessories for 750KVA DG Set including cleaning and serviceing complete all as specified and directed. |
| 56 | (a) Element Lub Oil Filter |
| 57 | (b) Kit Fuel Filter and Ring |
| 58 | (c) Kit Super Byp Filter Elem |
| 59 | (d) Element air cleaner |
| 60 | (e) Inhibitor corrosion 205 Liters |
| 61 | (f) Battery Pulse Lite 12 V 160 AH |
| 62 | (g) Valvoline Premium Blue 7800 Plus 1/210 Ltr |
| 63 | (h) Hinge Canopy RHS |
| 64 | (j) Radiwash 3 Liters |
| 65 | (k) Foil Sealed Test Strips CC2602B |
| 66 | Taking out Radiator form the 750 KVA DG set, dismantling all the parts cleaning and serviceing complete including replacement of petty spare parts , reclosing and refixing to its original position complete all as specified and directed. |
| 67 | Taking out FIP from engine assembly shifting of FIP to work shop overhauling of FIP complete after repalcment of unserviceable parts callibration of FIP returning from workshop refixing to engine assembly including replacement of nozzles and cleaning of nozzle pipes complete all as specified and directed for upto 750 KVA capacity by DG set.Note : (i) The cost of cleaning materials like kerosine oil cotton waste etc and lubricating item like mobile oil grease etc and patty spare parts required for this job are deemed inclusive in the rates. (ii) Nozzles and \"O\" rings are to be measued and paid separatly. |
| 68 | Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried dirctly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal od surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) tyep A1 duly reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable one complete all as specified and directed. |
| 69 | Material and labour and installation Bus bar , factory fabricated bus bar chamber out door pedestal type made out of 2.0 mm thick CRCA sheet siz 750x500x400mm duly painted with powder coating, simens grey /RAL fitted with four Nos aluminium bus bar of capacity 630 Amps duly mounted epoxy insulator , cable connections of incoming and outgoing cables duly insulated PVC heat shrinkable sleeve 1.1 KV grade including one No MCCB 600 Amps , 04 pole , 50 KA , with adjustable thermal stetting Ics=100% Icu, including glands c/p lugs etc including 50x50x6mm angle iron frame 450mm height above ground level and 450mm below ground level , angle iron frame shall be embeded in PCC (1:2:4) type B 1 block of size 200x200x200mm complete all as specified and directed |
| 70 | Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V gradeof size 95 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs complete all as specified and directed |
| 71 | Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V gradeof size 95 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs complete all as specified and directed |
| 72 | Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable and getting out. |
| 73 | Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection all as specified and directed. |
| 74 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed by Engr-In-Charge. |
| 75 | Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified. |
| 76 | Material and labour for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed by Engineer-in-Charge. |
| 77 | Material and labour for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed ofsize 40mm dia(make: prakash surya/jindal/TATA) |
| 78 | Taking down old U/S MCCB from existing panel board and Supply and fixing for new moulded case circuit breaker 4 pole 400 Amps 36 KA capacity with microprocessor release complete all as directed. |
| 79 | Taking down old U/S MCCB from existing panel board and Supply and fixing for new moulded case circuit breaker 4 pole 250 Amps 36 KA capacity with microprocessor release complete all as directed. |
| 80 | Taking down old U/S MCCB from existing panel board and Supply and fixing for new moulded case circuit breaker 4 pole 160 Amps 36 KA capacity with microprocessor release complete all as directed. |
| 81 | Supply & fixing in repairs of thermostat element alongwith complete assy for DG set connection and testing complete all as specified and directed by Engr-in-Charge.Make: As Per OEM Recommendation |
| 82 | Supply and fixing in replacement of Control assembly forDG Set capacityfrom 40 KVA to 82.5 KVA with necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets. of Make: Cummins/ Kirloskar/ Mahindra & Mahindra /Greaves. |
| 83 | Supply and fixing in replacement of Control assembly forDG Set capacityfrom 100 KVA to 250 KVA with necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets. of Make: Cummins/ Kirloskar/ Mahindra & Mahindra /Greaves. |
| 84 | Supply and fixing in replacement of PCB assembly forDG Set capacity160 KVA to 250 KVAwith necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets . |
| 85 | Supply and fixing in replacement of PCB assembly forDG Set capacity40 KVA to 82.5 KVAwith necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets . |
| 86 | Supply and fixing in replacement of Oil Pressure Sensor suitable for 40 KVA to 250 KVA DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge |
| 87 | Supply and fixing in replacement of Coolant TempetarureSensor suitable for 160-500 KVA DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge |
| 88 | Supply & Fixing Electronic timers with auxilary voltage of 110/240/415v 50Hz for operation of 12-120 secs . |
| 89 | Supply and fixing LK MCX 22 (100 A) Contractor as per the existing site requirement complete all as specified and directed |
| 90 | Supply and fixing Control relay contactors of MXO type operatable at AC/DC supplieswith NO/NC add ONas per the existing Site requirement complete all as specified and directed. |
| 91 | Supply and fixing in replacement all in one LED solar street light fitting IP66 of capacity 30 watt made up of aluminium housing with mono crystalline solar panels for higher efficiency including in built high quality lithiumferrophosphate (LiFePO4) battery of capacity minimum 240W Hour/ 24 Ah @12.8 V of temperature range -10 to +50 C, solar panel capacity 50 Wp, charge controller with dusk dawn sensor having 5250 lumens in 30 Watts with system efficacy not less than 175 Lumens per Watt, complete taking down existing unserviceable light fittings all as directed.Dimmer profile:(a) From dusk - first 4 hours-100% & dimming-25% in non occupancy(b) 2nd 7 hours - 25% (fixed dimming)(c) 3rd 1 hour - 40% & dimming-25% in non occupancy (till dawn conditions) |
| 92 | Description as per item No 63 here in before but capacity 40 Watts, complete all as specified and directed. |
| 93 | Material and labour for DC copper cable of size 4 sqmm , MC4 connectors , cable ties and PG 16 conduit along with laying and fixing of DC cable with SPV Moudules and constructions of arrays duly conduit in PG 16 conduit pipes properly fixed with saddles on walls or floor including fixing the arrays string with array junction box complete all as specified and directed |
| 94 | Supply and fixing of Array Junction box IP 65 comprising of DC fuses 30KA 1000V , DC SPD connectors duly fixed in polycarbonate box complete all as specifed and directed |
| 95 | Supply and fixing of array Junction box IP 65 comprising of ACDB 16 KA 1000V , AC SPD connectors duly fixed in polycarbonate box complete all as specified and directed |
| 96 | Supply and fixing of 33 KW Grid Interactive String Inverter MPPH as per IEC 62109-1,2, IEC 61683, IEC 61727 along with Zero Export Device with following features complete all as specified and directed (a) String current monitoring (b) IP66 protection for indoor and outdoor application |
| 97 | Supply and fix in repair solar water tank made up of stainless steelof capacity 200 litre, ISI marked,with electrical heating back up complete all as specified and as directed. Make :Stellar/Solarizer/TATA |
| 98 | Description as per item No 69 above but 300 Ltr capacity |
| 99 | Description as per item No 69 above but 500 Ltr capacity |
| 100 | Supply and fixing in replacement Panel Control forto500 KVA DG set with accessories under over relay (JV Relay) including all charges like calibration and service charges as directed by Emngr -in- charge . Make Cummins (Jakson) |
| 101 | Supply and fixing M S angle as infencing post including M S flat iron, MS bar alongwith required nut bolt washer all as specified and as directed |
| 102 | Supply only chain linl mild steel galvanised with 50mm square mesh of size of wire 3.15/4mm complete all as specified and directed |
| 103 | Fixing only chain link including line wire any mesh size and type of standard , rail , bolts etc including provision of binding wire complete all as specified and directed |
| 104 | Supply and fixing Mild steel sliding door bolt 200mm long , plate type stove enamled block, with bright bolt not less than 12mm dia bolt with and including a minimum of 06 bolts and nuts on bolt plate and two on stable plate complete all as specified and directed |
| 105 | Supply and fixing mild steel cold rolled but hings medicum weight 125 mm long including fixing to pressed steel door frame if required complete all as specified and directed |
| 106 | Material and labour for MS angle iron work as in door or gates of angle or other section with rails, braces etc complete drilling for fixing of steel sheeting or other covering for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusinve or steel sheeting or other covering, running rail and guides ) and hanging also fastening and fixing complete all as directed |
| 107 | Material and labour for brick work with sub class \"B\" brick straight or curved on plan exc 6m mean radius built in cement mortar type 1.6 all as specified and as directed |
| 108 | Material and labour for PCC 1:4:8 type D2 (using 40mm graded cushed stone aggregate as in foundation filling as mass concrete including necessary from work all as specified and asdirected |
| 109 | Material and labour for 15mm thick rendering on brick surface as in cement mortar 1:6 and finished surface even and smooth without using extra cement complete all as specified. |
| 110 | Material and labour for applying three coats of white washing on walls including preparation of newly plastered surfaces complete all as specified |
| 111 | Supply and fixin repair Pre filter of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 112 | Supply and fixin repair Sedimant filter of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 113 | Supply and fixin repair Carbon filter of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 114 | Supply and fixin repair Membrane filter of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 115 | Supply and fixin repair Mineral filter of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 116 | Supply and fixin repair UV barell filter of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 117 | Supply and fixin repair Booster pump of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 118 | Supply and fixin repair SV of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 119 | Supply and fixin repair SMPS of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 120 | Supply and fixin repair Float switch of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 121 | Supply and fixin repair flow resticter switch of RO of size 180 Ltrs per hours complete all as specified and directed. |
| 122 | NOTE:- Amount of credit ofRs. 88844.00 for retrieved materials is mentioned in Schedule of Credit Page No25 of tender documents in pdf form which will be deducted offline while acceptance of tender. |