| 1 | Labour only for attending day to day external water supply complaints of all nature i.e leakage in water supply pipe lines, fitting/fixture, over flow of overhead tank, no water supply,taking out waterfrom trenches during repair including noting the complaints in complaint register complete all as directed by Engineer-in-charge. (Any material required for attending complaints shall be measured and paid separately under respective item herein after) |
| 2 | Labour only for attending day to day electric supply complaints of day to day mantenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including nothing the complaints fromNodal Point No. I and allied areas in complaints register and distribution to the trademen complete all as directed (any meterial required for atteding complaints shall be measured & paid seperately under respective item here after)Note:- The suitable shift duites as deems fit shall be decision of the Engr-in-charge |
| 3 | Notes for Item No 1.01 & 1.02 :-(i) The complaints shall be attended and the defects shall be rectified by a team of expert and experiencedelectrician/plumber as applicable assisted with adequate No of helpers complete all as specified and as directed.(ii) The complaints shall be attended and defect shall be rectified within 08 hrscommencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor\"s dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complained (iii) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made.(iv) While attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch \"A\" . However no extra payments shall be made for dewatering.(v)Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A.(vi)All T & P as well as dewatering motor single phase of 3HP with including 100 mtr cable, required for attending the complaints shall be provided by the contracor.(vii) The pipe fitter shall always be in possession of die set complete with cutters , boring Tups , Pipe wrench, Chain wrench,Caulking tools,set of spanners and ladders,wehicle/Ricksha etc Complete,all as required at site. |
| 4 | (viii) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc complete all as required at site and directed by Engr-in-charge.(ix)All material reqd at site for day to day maintenance shall be issued by Deptt under respective items here in after. |
| 5 | Supply only the following items :- |
| 6 | GI Socket Med Grade ,ISI marked of following Size:- |
| 7 | 15 mm bore |
| 8 | 20mm bore |
| 9 | 25mm bore |
| 10 | 40mm bore |
| 11 | 50mm bore |
| 12 | GI Elbow Med Grade, ISI marked of following Size:- |
| 13 | 15 mm bore |
| 14 | 20mm bore |
| 15 | 25mm bore |
| 16 | 40mm bore |
| 17 | 50mm bore |
| 18 | GI Union Med Grade ,ISI marked of following Size:- |
| 19 | 15 mm bore |
| 20 | 20 mm bore |
| 21 | 25 mm bore |
| 22 | 40 mm bore |
| 23 | 50 mm bore |
| 24 | GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:- |
| 25 | 15 mm bore |
| 26 | 20mm bore |
| 27 | 25mm bore |
| 28 | 40mm bore |
| 29 | 50mm bore |
| 30 | PVC \"L\" type Holder, Aluminium rod,Float Ball etc all as required at site and all as directed of following Size:- |
| 31 | 15 mm bore |
| 32 | 20mm bore |
| 33 | 25mm bore |
| 34 | 40mm bore |
| 35 | 50mm bore |
| 36 | Gi Reducing socket mediumgrade isi marked to following sizes |
| 37 | 25 mm x 15 mm bore |
| 38 | 20 mm x 15 mm bore |
| 39 | 25 mm x 20 mmbore |
| 40 | 50 mmx 40mmbore |
| 41 | GI solid plugheavy dutyisi marked to following sizes |
| 42 | 15 mm bore |
| 43 | 20mm bore |
| 44 | 25mm bore |
| 45 | 40mm bore |
| 46 | 50mm bore |
| 47 | GI TEE of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:- |
| 48 | 15 mm x 15 mm x 15 mm |
| 49 | 20 mm x 20 mm x 20 mm |
| 50 | 25 mm x 25 mm x 25 mm |
| 51 | 40 mm x 40 mm x 40 mm |
| 52 | 50 mm x 50 mm x 50 mm |
| 53 | GI reducing TEE of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:- |
| 54 | 20 mm x20mmx15mm |
| 55 | 25 mmx25mmx15mm |
| 56 | 25 mmx25mmx20mm |
| 57 | 40 mmx40mmx15mm |
| 58 | 40 mmx40mmx20mm |
| 59 | 40 mmx40mmx25mm |
| 60 | 50 mmx50mmx15mm |
| 61 | 50 mmx50mmx20mm |
| 62 | 50 mmx50mmx25mm |
| 63 | 50 mmx50mmx40mm |
| 64 | Supply and laying tubing GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor including taking outas directedof following sizes :- |
| 65 | 15mm bore |
| 66 | 20 mm bore |
| 67 | 25 mm bore |
| 68 | 40 mm bore |
| 69 | 50 mm bore |
| 70 | Supply only of Lead Pig bar of standard quality inclosed container complete all as specified and directed. |
| 71 | Supply only Spun Yarn of best quality in bundles complete all as specified and directed. |
| 72 | Supply only Lead Wool |
| 73 | Supply only Nuts, Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and as directed. |
| 74 | Supply onlyPTMT Float valve with epoxy coated aluminium rod and high density HDPE ballof following sizes complete all as specified. |
| 75 | 15 mm bore dia |
| 76 | 20 mm bore dia |
| 77 | 25 mm bore dia |
| 78 | 40 mm bore dia |
| 79 | 50 mm bore dia |
| 80 | Supply & fixing PTMT Float valve with epoxy coated aluminium rod and high density HDPE ballof following sizes complete all as specified. |
| 81 | 15 mm bore dia |
| 82 | 20 mm bore dia |
| 83 | 25 mm bore dia |
| 84 | 40 mm bore dia |
| 85 | 50 mm bore dia |
| 86 | Supply onlygun metal gate/ballvalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of followingsizes complete all as specified. |
| 87 | 15 mm bore dia |
| 88 | 20 mm bore dia |
| 89 | 25 mm bore dia |
| 90 | 40 mm bore dia |
| 91 | 50 mm bore dia |
| 92 | Supply only Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms/20mm-125gms). complete all as specified and as directed. |
| 93 | 15 mm bore dia |
| 94 | 20 mm bore dia |
| 95 | Opening the existing Sluice Valve including opening of gland cover taking out with stem nut of brass or of stainless steel & refixing the same after with & incluiding replacement of rubber packing, nut & bolts, glands dori, etc complete all as specified and directed of following sizes. (Note :- Spare parts under relevant items shall be measured and paid separately under repsiective items) |
| 96 | 80 mm bore |
| 97 | 100 mm bore |
| 98 | 150 mm bore |
| 99 | 250 mm bore |
| 100 | Supply only \"Gland Plate\" made out from Cast Iron suitable to match with existing sluice valve, sizes as under, complete all as specified and as direct |
| 101 | 80 mm bore |
| 102 | 100 mm bore |
| 103 | 150 mm bore |
| 104 | 250 mm bore |
| 105 | Taking up or down CI/DI/MS Pipe of following sizes including all fittings) with spigot and socketed endsand lead tyton joints includingburning out lad jointsand recovering lead and including cleaning for refixing or removal complete all as specified and as directed.Note:- Excavation & earth work shall be measured & paid separetely. |
| 106 | 100 mm bore |
| 107 | 150 mm bore |
| 108 | 200 mm bore |
| 109 | Supply, layingjointing,testingDIpipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work & rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes including taking down of existing CI/DI pipe complete all as specified and directed by Engineer-in-Charge.(Note : (i) Excavation & earth work shall be measured & paid separetely under respective items of BOQ.(ii) Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.(iii) DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV\"s, MTC & e-way bill will produced by contractor during payment of 1s RAR as material laying at site.(iv) Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.(v) Layout plan for laying of DI pipe shall be given by EIC in writing.(vi) Cost of Rubber gasket joints (Tyton Joint) included in quoted unit rates. |
| 110 | 100mm bore |
| 111 | 150 mm bore |
| 112 | 200 mm bore |
| 113 | Material and labour for Rubber Gasket Joint (tyton joint)including jointingmaterial for DI/CI pipe of following sizes, complete as specified. |
| 114 | 100 mm bore |
| 115 | 150 mm bore |
| 116 | 200 mm bore |
| 117 | Labour for cutting of existing CI / DI pipe for insertion of CI specialsetc. all as required including dewatering of lekage water all as required of the following sizecomplete all as specified and as directed . |
| 118 | 100 mm bore |
| 119 | 150 mm bore |
| 120 | 200 mm bore |
| 121 | Supplying and fixing of of DI/CI MJ collar of the following sizes:- |
| 122 | 100 mm bore |
| 123 | 150 mm bore |
| 124 | 200 mm bore |
| 125 | 250 mm bore |
| 126 | 300 mm bore |
| 127 | 400 mm bore |
| 128 | Supplying & Fixing, jointing and testing of cast iron Sluice ValveISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified. |
| 129 | 80 mm borepipe |
| 130 | 100 mm borepipe |
| 131 | 150 mm bore pipe |
| 132 | 250 mm borepipe |
| 133 | S&F in replacement three Pole Power Contactor 25 Amp 415/440 volts 50 HZtype ML 1.5 or MNX Type range 25 Amps complete all as specified and directed |
| 134 | S&F in replacement three Pole Power Contactor 32 Amp 415/440 volts 50 HZtype ML 2 or MNX Type range 40 Amps complete all as specified and directed |
| 135 | S&F in replacement Bimetal Over load relay for ML 1.5 or MNX Type with range 9-14 Amp complete all as specified and directed |
| 136 | S&F in replacement Bimetal Over load relay for ML 2 or MNX Type with range 13-21 Amp complete all as specified and directed |
| 137 | S&F in replacement Bimetal Over load relay for ML 3 or MNX Type with range 20-32 Amp complete all as specified and directed |
| 138 | S&F in replacement Bimetal Over load relay for ML 4 or MNX Type with range 32-40 Amp complete all as specified and directed |
| 139 | S&F in replacement of FASD ML-1.5/MN 16 Type with relay range 9-15 Amps complete all as specified and directed |
| 140 | S&F in replacement of FASD ML-2.0/MN 25 Type with relay range 14-23 Amps complete all as specified and directed |
| 141 | Supply and fix in replacement of3 Pole MCCB,63 Amp, 50 Hz, 415 V with rupturing capacity 10 KAcomplete all as specified and directed |
| 142 | Supply and fix in replacement of3 Pole MCCB,100 Amp, 50 Hz, 415 V with rupturing capacity 16 KAcomplete all as specified and directed |
| 143 | Supply and fix in replacement of4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed |
| 144 | S&F in replacement moulded case circuit breakers 4 pole 200 Amps having breaking capcity 36 KA at 415 volts complete all as specified and directed |
| 145 | Supply and fixing in replacement Pressure gauge of suitable pressure upto 14 Kgs/cum all as existing including necessary fitting, complete all as specified and directed. |
| 146 | Testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) in the area under AGE(U) W/S No III and submission of detailed test reqport to the office of Engineer-in-Charge.(a)Collection of water from different sources of water ie Sump, bore wells& shallow wells in sterilized bottle for testing of water of different sources from Govt Approvedlaboratory as mentioned in PS.(b)Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission the test report to EIC and after ward the same will be submit by EIC to AO with their specific recommendation regarding suitability of water for drinking purpose. |
| 147 | S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed |
| 148 | S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete all as specified & directed |
| 149 | S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed |
| 150 | S&F modular socket outlet 2 in 1, 5 pin, 16 Amps, flush type, 230 volts with socket frame complete all as specified & directed |
| 151 | S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 120 watts incl connection complete all as specified & directed |
| 152 | PVC insulation tape role of length 10 M |
| 153 | PVC adhisive tape role of length 10 M |
| 154 | Supply only Ceiling rose 3 terminal PVC/Polycarbonate, isolated body 230 volt |
| 155 | Supply only MCB of following sizes:- |
| 156 | SP 6 to 32 Amp, 240 volts \"c\" curve |
| 157 | SPN40 Amp , 240 volts\"c\" curve |
| 158 | Supply and fixing in repair copper terminals lugs (Thimbles)ring type medium duty for following sizes :- |
| 159 | 25 Sqmm |
| 160 | 35 Sqmm |
| 161 | 50 Sqmm |
| 162 | 70 Sqmm |
| 163 | 95 Sqmm |
| 164 | Supply and fixing in repair Aluminium terminals lugs (Thimbles)ring type medium duty for following sizes :- |
| 165 | 16 Sqmm |
| 166 | 25 Sqmm |
| 167 | 35 Sqmm |
| 168 | 50 Sqmm |
| 169 | 70 Sqmm |
| 170 | 95 Sqmm |
| 171 | 120 Sqmm |
| 172 | Supply and laying LTXLPE UG armoured , heavy duty electric cable with aluminium conductor, 1100 volts grade, of cross siectional areaof following sizes including taking down the existing XLPE cable one and deposited to MES store yard all as directed:-(Note :- (a) Excavation & earth work brick protection & sand cushioning shall be measured and paid seperately under respective items. (b) Layout plant shall be given by Engineer-in-Charge to contractor in writing. |
| 173 | 16 Sqmm, 4 core |
| 174 | 35 Sqmm, 3.5 core |
| 175 | 50 Sqmm, 3.5 core |
| 176 | 70 Sqmm, 3.5 core |
| 177 | M/L for sand filling in cable ducts/ trenches with and including removing old sand to a distance not exceeding 50 mtr away and depositing where directed by Engineer-in-charge. |
| 178 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete. |
| 179 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed., |
| 180 | S&F in replacement of Water Level Indicator (Mechinical type)at semi under ground water reserviors including providing greasing the pully, including adjustment of steel rope/float ball for its proper calibration and replacement of existing unserviceable nut and bolt, pully, float ball and steel rope making functional for its smooth effecient functioning complete all as specified and directed.Note:- Float ball and steel rope shall be measured and paid for seperately. |
| 181 | Supply and fixing steel rope stranded (flexible 3 mm dia complete all as specified and directed as per sample). |
| 182 | Suply and fixing in replacement of Brass ball of size 150 mm bore complete with suitable size u clamps for manual water level indicator coplete all as specified and as directed |
| 183 | Surface Excavation not exceeding 30 cm deep averaging 15 cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installation/around the valve pit chamber/along the pipe line routesetc and getting out soft/loose soil, all as specified and as directed at site by Engineer-in-Charge. |
| 184 | Earthing complete with galvanised steel earth plate ectrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 185 | Supply and laying of rubber insulated mat of size 2.00 mtr x 1.00 mtrof 19 mm thick ISI marked complete all as specified and as directed by Engr-in-charage. |
| 186 | Supply andfixingrotational moulded polyethylene water storage tank, cylindrical vertical with closed top,500 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed.. |
| 187 | Supply andfixingrotational moulded polyethylene water storage tanks, cylindrical vertical with closed top, 1000 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity)complete all as specified and as directed.. |
| 188 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M indepth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed. |
| 189 | Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick all as specified and as directed by the Engineer-in-charge. |
| 190 | Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed. |
| 191 | Supply & laying of Sub Class \"B\" brick laid across the cable above the sand cushioning for protection of cable complete all as specified and directed |
| 192 | M&L Brick work with sub class \"B\" old size bricks straight or curved on plan exceeding 6 m mean radious built in cement mortar 1:6 complete all as specified and directed |
| 193 | M & L PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed |
| 194 | M&L Machine pressed precast concrete interlocking paverblocks any shape and size confirming to IS 15658-2006 of 60 mm thick, M-40 Grade with grey cement and no pigments, over 25 mm thick sand cushioning including taking down existing pavers and deposited to store yard complete all as specified and as directed. |
| 195 | Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends, removal of fault & reconnection and testing of cables after removal of fault complete all as specified and directed by Engr-in-charge. NOTE:(a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule. |
| 196 | S&F in replacement of PVC insulated multistranded copper conductor cable single core 1100 Volts grade of following sizes. |
| 197 | 16 sqmm |
| 198 | 25 sqmm |
| 199 | 50 sqmm |
| 200 | Disconnecting of electrical connection from panel board and taking out submersibleof Cap upto 10 HP from borewell and transporting submersible motor to workshop and back after repair, reinstall and testing complete all as specified and as directed |
| 201 | Supply only super enamelled copper winding wire of suitable gauge |
| 202 | Opening the submersible motor pump set of cap upto 10 HP and taking out the burnt winding wire complete and cleaning the slots rewinding the motor with super enamelled copper wire of existing gauge/size with and including insulating material. Compete all as specified and as directed. (Note : \"Copper winding wire of appropriate gauge will be measured under item above as supply only\") |
| 203 | Supply and fixing in replacement Submersible cable flat/round 3 Core 2.5Sqmm all as specified and directed |
| 204 | Supply and fixing in replacement Submersible cable flat/round 3 Core 4 Sqmm all as specified and directed |
| 205 | Supply and fixing in replacement Submersible cable flat/round 3 Core 6 Sqmm all as specified and directed |
| 206 | Supply and fixing submersible cable joint kit of suitable size all as specified and directed |
| 207 | M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris complete all as specified and directed by the Engineer-in-Charge. |
| 208 | M & L in replacement Tank Cover/Valve Chamber Cover made out of mild steel plain sheet of any thickness as in cover for existing valve chamber along with provision of angle iron frame cut to length, bent to shape, welding and fabricate to requiredd shape/ size incl necessary fixing materials like hinges, nut/ bolts etc withtwo coat of synthetic enamel paint overa coat of red oxide primarand incl lifting handle andtaking out the old unsv valve chamber cover complete all as specified and directed. |
| 209 | M&L for painting ofexisting Steel/RCC surface with two coat of Black/Blue colour synthetic enamelled paint including preparation of surfaces. |
| 210 | M&L for writing letter or figures (Block, Roman, Italic of Indian) not exc 30cm high, letter shall be painted with thick synthetic enamel paint so that they stand out boldly and solidly without showing signs or brush mark. |
| 211 | Material and labour Painting with two coat supper enamelled paint with of Pump set including electric driven motor, coupling, base frame, sluice valve, NRV etc of capacity up to 200 HP complete withall as specified and as directed by Engineer-in-charge. |
| 212 | M & L for painting of Sluice Vlave, NRV, upto 450 mm bore with two coat of supper enamelled paint including preperation of old surface complete all as specified and as directed byEngineer-in-charge. |
| 213 | Supply and fixing in replacement of domestic type water flow meter class \"B\" conforming to IS :779/1994 all as specified and directed |
| 214 | Same as above but 100 mm bore dia pipe. |
| 215 | Same as above but 250 mm bore dia pipe. |
| 216 | Same as above but 300 mm bore dia pipe. |
| 217 | Supply and fixing in replacement of water meterwoltman type of size 600 mm bore including diconnecting of existing unsv wate meterand making connection with flanged ends, with rubber gasket sheet and nut and bolts all T & P (JCB/HYdra required complete all as specified and as directed at site by Engr in charge |
| 218 | M&L for taking out existing grass bydigging up to0.30m in deep of green park of size 16mx25m and filling fresh sand up to .30 m in the existing green park and with including grow fresh all season green grass in the existing park all as specified and directed.( Note : All T&P expenditure/price whereas required at site is included in the job cost only) |
| 219 | An amount of Rs 1,64,905.00 shall be deducted from BOQ on account of schedule of credit |