| 1 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 2 core 6 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables, complete all as specified and directed |
| 2 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 4 core 16 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables, complete all as specified and directed |
| 3 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 25 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables, complete all as specified and directed |
| 4 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 35 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables, complete all as specified and directed |
| 5 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 50 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables complete all as specified and directed |
| 6 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 70 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables complete all as specified and directed |
| 7 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 95 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables complete all as specified and directed |
| 8 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 120 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables complete all as specified and directed |
| 9 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 150 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables, complete all as specified and directed |
| 10 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 185 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables, complete all as specified and directed |
| 11 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 240 sqmm in trench/duct/floor/wall provision of saddle and lugs,joints etc including taking down of old UG cables complete all as specified and directed |
| 12 | Supply,installation,testing and commisioning in replacement of factory made type,dust and vermin proof totally enclosed LT feeder pillar box outdoor type, CPRI type tested for IP65 and fully comparted type, fabricated out of 3mm thick CRCA sheet,duly painted with epoxy powder coating with 9 tank process and conforming to IEC-61439 withprovn of front double door shutter with locking arrangement mounted upon 40x40x6mm size angle frame of iron clad and coated paint over one coat of red oxide primer,complete all as specified and directedi)Aluminium Bus bar TPN 600 Amp of suitable length and section covered with coloured heat shrinkableanti track insulation tape of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height - 01 set with following specificationsii) MCCB 4P,400 Amp,Ics=Icu=36KA, 415 V, 50Hz with adjustable Thermal magnetic t release -01 No(incomer) iii) MCCB 4P, 250 Amp, Ics=Icu=25KA 415 V,50Hz with adjustable Thermal magnetic release and double breaking mechanism- 03 Nos (outgoing)iv)MCB 4P , 63A ,Ics 25KA 415 V,50Hz- 01 Nos (outgoing)v) Danger notice plate riveted on outer body 440 Voltvi) RYB indications (LED Type) - 01 setvii) Multifunctional meter digital compatiable to measure voltage,current,PF,frequecy with 3 lines display LCD in 96x96 sqmm flush mounted case accuracy class 1.0-01Nos |
| 13 | Supply,installation,testing and commisioning in replacement of factory made type,dust and vermin proof totally enclosed LT feeder pillar box outdoor type, CPRI type tested for IP65 and fully comparted type, fabricated out of 3mm thick CRCA sheet,duly painted with epoxy powder coating with 9 tank process and conforming to IEC-61439 withprovn of front double door shutter with locking arrangement mounted upon 40x40x6mm size angle frame of iron clad and coated paint over one coat of red oxide primer,complete all as specified and directedi)Aluminium Bus bar TPN 400 Amp of suitable length and section covered with coloured heat shrinkableanti track insulation tape of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height - 01 set with following specificationsii) MCCB 4P, 250 Amp,Ics=Icu=36KA,415 V, 50Hz with adjustable Thermal magnetic release and double breaking mechanism - 01 No(incomer) iii) MCCB 4P, 100 Amp, Ics=Icu=25KA 415 V,50Hz with adjustable Thermal magnetic release and double breaking mechanism- 04 Nos (outgoing) iv) MCB 4P, 63A, Ics=25KA, 415 V,50Hz- 02 Nos (outgoing)v) Danger notice plate riveted on outer body 440 Voltvi) RYB indications (LED Type) - 01 setvii) Multifunctional meter digital compatiable to measure voltage,current,PF,frequecy with 3 lines display LCD in 96x96 sqmm flush mounted case accuracy class 1.0-01Nos |
| 14 | Supply and fix of 7m square deco pole with single arm bracket made of MS with pu painted, of dimensions 100mmX100MMX2.5mm thick. The pole should be with deco single arm bracket , the base plate size of 220X220X12mm; pole should have built-in weather proof loop out option, 4 Nos of hot dip galvanized foundation bolts having size M20X700mm long for strengthening the foundation including nuts, washer etc as per OEM specifications including 1.5 sqmm 2 core cable 10 A single pole MCB and 16 A TPN connector, including taking down old one complete all as specified and directed. |
| 15 | Supply and fix 120 W IP66 LED streetlight with contemporary design,housing made of die cast aluminium with street optic lens and glass diffuser for uniform light distribution, including taking down old one complete all as specified and directed. |
| 16 | Supply install testing and commisioning Timer panel , outdoor type,powder coated, dust vermin and weather proof outdoor type,cubical type,outer shell made out of 3mm thick CRCA sheet and MS angle iron section of 50x50x6 mm frame factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides with TPN MCB-63 Amps as incomer with suitable auxillary contactor of 65 A, AC 3 rating 3 ph, digital timer switch,auxillary change over switch 6A, On/Off indicating lamp and all necessary winding with suitable copper flexible wire,unservicable timer panel complete all as specified and directed |
| 17 | Supply and fixing cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured conductor cable of size 25 to 50 sqmm,complete all as specified and directed |
| 18 | Supply and fixing cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured conductor cable of size 70 to 150 sqmm, complete all as specified and directed |
| 19 | Supply and fixing cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured conductor cable of size 185 to 240 sqmm, complete all as specified and directed |
| 20 | Supply and fixing 4 Pole MCCB 100 Amp ,50 Hz ,415 V, Adjustable thermal and Adjustable magnetic, with rupturing capacity 25 KA, including taking down old one complete all as specified and directed |
| 21 | Supply and fixing 4 Pole MCCB 250 Amp ,50 Hz ,415 V, Adjustable thermal and Adjustable magnetic, with rupturing capacity 36 KA, including taking down old one complete all as specified and directed |
| 22 | Supply and fixing 4 Pole MCCB 400 Amp ,50 Hz ,415 V, Adjustable thermal and Adjustable magnetic, with rupturing capacity 36 KA, including taking down old one complete all as specified and directed |
| 23 | Supply and fixing SMC junction box of size 250 x 200 x 100mm ,GSJB-2520 including one MCB SP 6 Amps for controlling street/ security lights water tight, including taking down old one complete all as specified and directed |
| 24 | Supply,laying and testing of Flexible copper wire 1100 volts grade 3 core 4 sqmmcomplete all as specified and directedof |
| 25 | Supply, fixing and testing of LED post top light coated with pure polyester UV resistant powder, die-cast aluminium housing with polycarbonate clear diffuser for uniform lighting and IP65 protection and of 45 watt capacity with all the standard accessories as per design of manufacturer complete all as specified and directed |
| 26 | Cutting existing road/ hardstand/ concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to adepth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed |
| 27 | Material and labour for GI tubing light grade (ISI marked) of size 80 mm dia with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps,nut bolt etc, including taking down old one complete all as specified and directed |
| 28 | Material and labour for GI tubing light grade (ISI marked) of size 50 mm dia with all fitting/accessories for protection of cable on pole/wall and under rad crossing including clamps,nut bolt etc, including taking down old one complete all as specified and directed |
| 29 | Excavation in trenches not exceeding 1.5m in depth and not exceeding 1.5m wide for laying pipeand getting out in soft/loose soil complete all as specified and directed |
| 30 | Returning,filling in soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm complete all as specified and directed |
| 31 | Removing excavated materials not exceeding 50m depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed |
| 32 | Laying of riddle soil obtained from excavation and cushioning covering of UG cablesin trenches complete all as specified and directed |
| 33 | Supply and laying un-reinforced precast concrete cable cover of class LV, type - 1, flat , size 250 mm X 150 mm X 40 mm laid in trenches for protectionofcable complete all as specified and directed . |
| 34 | Materials and labour for earthingcomplete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with galvanised strip of size 32 x 6 mmby means of nuts, bolts, check nuts and washers including welding of each joints made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 metre etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, including taking down old one complete all as specified and directed. |
| 35 | Supply and laying of100 mm bore High density polyethylene pipes ( HDPE ) PN 10 laid in tenches/wall/road crossing for suitable length as per site requirement including taking down of old unservicable HDPE/GI pipes complete all as specified and directed |
| 36 | Material and labour for common burnt clay building bricks sub-class \"B\" designation of size 230x115x75 mm laid in trenches for protection of cable complete all as specified and directed. |
| 37 | Material and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in GI pipe40 mm or fixed with poles or any other indicated situation for loop earthing etc as required using galvanised iron strip of size 32 x 6 mm complete all as directed |
| 38 | Supply and LayingUG cableXLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 2 core 16 Sqmm intrench /duct/floor/wall with provision of saddle and lugs, joints etc including connectioncomplete all as specified and directed |
| 39 | Supply and LayingUG cableXLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 2 core 10 Sqmm intrench /duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed |
| 40 | Supply and fix instreet light TIMER control panel, pole/wall mounting made out of CRCA sheet duly powder coated with locking arrangement, incl internal wiring complete with bypass arrangements including anfle iron stand with foundationcomprising of following :- (or as manufactures recommendation and design).consisting of the following:-(a) Incomer MCB TPN 40 Amps, 240/410V- 01 Nos (b) Digital timer switch - 01 No (c) Contactor AC 3 rating, 3ph, of capacity 32 Amps - 01 No(d)ON/OFF indicating lamp - 01 Set(e)Auxilary change over switch 6 A - 01 No |
| 41 | Material and labour for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of eath plate not less than 1.5mtr belowground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C 1 using 20mm raded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80mm thick RCC pit cover 320mm x 320mm of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinformed with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR part -I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point/ transformer nuetral/body/ LT panel etc and tesing on completion, complete all as specified and directed |
| 42 | Supply and fix 9 M hot dipGI Octagonal pole conforming to BSEN 10025 & galvanization BS EN ISO 1461 or equivalent with 3 mm sheet thickness and > 65 microns with confirming windspeed of 47 M/s. Pole should be of 70 mm top dia and 155 mm bottom dia. For the electrical termination and connections the pole should have inbuild door munting 500mm above from ground with proper gaskets & alien key arrangements for safety locking. Pole should withstand in 4 Nos of END hot dip galvanised M20x 700mm J bolts and baseplate of 250x250mm with a 16 mm thickness conforming to IS 2062. PCD= 250mm conforming BSEN10025,BESEN ISO 1461. The pole shall be supplied alongwith hot dip galvanised single arm bracket 0.5 mtr complete all as specified and directed |
| 43 | Supply and fix LED Street light luminarie of 90W,housing made from high pressure die cast aluminium(ADC12),integrated lens cover with IP-66 degree of protection.System efficacy of > 120 Lumen/watt CRI> 70 and co related color temperature(CCT) of 5700K(ANSI).The luminarie should have 4KV+ 10KV surge protection integrated with driver,PF>0.95,and total harmonic distortion of THD<10%,operating voltage range of 120V-270V should be provided. The driver used must be constant current potted driver with efficiency of >85% & electrical class1.Brand embossing of Brand for traceability till life. LM79(not older than 1 year) LM80 from the source manufacturer for >= 9000 Hrs,luminarie like at 50K burning hours. LED makes approved complete all as specified and directed |
| 44 | Material and labour for PVC insulated copper conductor 3 core 1.5 sqmm cable to be drawn inside the pole ,for connection of street lightcomplete all as specified and directed |
| 45 | Material and labour for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed ofsize 40mm dia complete all as specified and directed |
| 46 | Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable complete all as specified and directed. |
| 47 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed |
| 48 | Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified. |
| 49 | Material and labour Brick well burnt Class \"B\" as in cover to UG cable, laid dry. flat over the cable with width equal to legth of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over UG cable for cable protection in trenched complete all as specified and directed |
| 50 | Material and labour for sand cushioning and covering of UG cable using riddle soil in trenches for cable protection complete all as specified and directed |
| 51 | Supply,laying and testing of UG cable XLPE insulated PVC sheathed,armoured,aluminium conductor cable 1100 volts grade 3.5 core 120 sqmm in trench/duct/floor/wall provision of saddle and lugs, joints etc, complete all as specified and directed |
| 52 | Material and labour for MCCB 4P, 250 Amps Ics=Icu=36KA, 415 V, 50Hz with adjustable Thermal magnetic releasewith sheet metal enclosure and extending the existing bus bar rating 800 amps and connecting new MCCB enclosure with the LT Panel including all the necessary accessories such as bus bars, nuts, bolts etc complete all as specified and directed |
| 53 | Supply, installation, testing and commissioningof factory made type, dust and vermin proof totally enclosed LT feeder pillar box outdoor type, CPRI type tested for IP65 and fully comparted type, fabricated out of 3mm thick CRCA sheet, duly painted with epoxy powder coating with 10 tank process withprovn of front double door shutter with locking arrangement mounted upon 40x40x6mm size angle frame of iron clad and coated paint over one coat of red oxide primer,complete all as specified and directedi)Aluminium Bus bar TPN 400 Amp of suitable length and section covered with coloured heat shrinkableanti track insulation tape of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height - 01 set with following specificationsii) MCCB 4P, 250 Amp,Ics=Icu=36KA,415 V, 50Hz with adjustable Thermal magnetic release and double breaking mechanism - 01 No(incomer) iii) MCCB 4P, 100 Amp, Ics=Icu=25KA 415 V,50Hz with adjustable Thermal magnetic release and double breaking mechanism- 02 Nos (outgoing) iv) MCB 4P, 63A, Ics=25KA, 415 V,50Hz with adjustable Thermal magnetic release and double breaking mechanism - 02 Nos (outgoing)v) Danger notice plate riveted on outer body 440 Voltvi) RYB indications (LED Type) - 01 setvii) CT of suitable ratio as per requirementviii) Multifunctional meter digital compatible to measure voltage, current, PF, frequency with 3 lines display LCD in 96x96 sqmm flush mounted case accuracy class 1.0-01Nos |
| 54 | Supply and fixing cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured conductor cable of size 70 to 150 sqmm,complete all as specified and directed |
| 55 | Materials and labour for earthingcomplete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with galvanised strip of size 32 x 6 mmby means of nuts, bolts, check nuts and washers including welding of each joints made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 metre etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 56 | Supply and laying un-reinforced precast concrete cable cover of class LV, type - 1, flat , size 250 mm X 150 mm X 40 mm laid in trenches for protectionofcable complete all as specified and directed . |
| 57 | Material and labour for GI tubing light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps,nut bolt etc complete all as specified and directed |
| 58 | Supply and fixing cable route indicators of material Cast iron complete all as specified and directed |