| 1 | S&Fin repair switch socket combination 2 in 1,3 pin 5 and 15 Amp flush type. |
| 2 | S&Fin repair switch socket combination 3 pin 5 Amp flush type all as specified. |
| 3 | S&Fin repair switch piano type 5 Amps 230 volts one way all as specified. |
| 4 | S&Fin repair holder any type for batten fitting all as specified. |
| 5 | S&Fin repair bell,AC 230Volts single pole all as specified. |
| 6 | S&Fin repair bell push flush type single pole one way 5 amp all as specified. |
| 7 | Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socketor power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc. |
| 8 | Material and labourfor point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5sqmm including necessary termination board 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earthingand connected to common earthing with PVCheavy duty casing caping/PVC conduit ISI marked as rquired at site along with all accessories and making good the disturbed surfaces of wall/ ceiling etcfor the following: |
| 9 | One light point/ one fan point/ Bell point controlled by one switch all as specified. |
| 10 | One 3 pin socket outlet, 5 Amp independent board all as specified. |
| 11 | One 3 pin socket outlet 5 Amps on same board with other switches all as specified. |
| 12 | All as per item No 8 above butfor point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy dutyISI marked /heavy duty conduitISI marked as required at site alongwith accessories with 2.5 Sq mmFRLS PVC insulated unsheathed copper conductor cable as earthing and connected to common earth all as specified. |
| 13 | M & L for point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables of 4.0 sqmm size alongwith one earth continuity conductor with FR PVC insulated unsheathed multistranded copper conductor cable of 4.0 sqmm size drawn through and including PVC casing & caping ISI Marked / PVC conduit ISI Marked as required at siteterminated in and including PVC block 50 mm deep for fixing of switches/ sockets for one 3/5 pin socket outlet, 15 Amps, on independent board. Note : Point wiring for 15 Amps on independent board should be tapped from nearest MCB DB all as specified. |
| 14 | S & Fswitch socket combination 2 in 1,3 pin 5 and 15 Amp flush type all as specified. |
| 15 | S & Fswitch socket combination3 pin, 5 amp flush type all as specified. |
| 16 | S & Fswitch piano flush type single pole one way 5 amp all as specified. |
| 17 | S & Fbell, AC 230 volts single pole all as specified. |
| 18 | S & F bell push flush type single pole one way 5 amp all as specified. |
| 19 | S&F ceiling rose3 terminal PVC/polycarbonate type ISI marked all as specified. |
| 20 | S&F in repair warm white/ white LED luminaire 600X600 mm,35/36 watt,220V recessed type lumen output >= 122 lumen per watts , THD < 10% environmental friendly , new generation , aesthetically designed , ultra modern with high brightness SMD LEDs as light source incl inbuilt driverswith high efficiency PMMA diffuser soft glare free light completesuitable for roof ceiling including connecting up with three core flexible copper conductor of suitable size all as specified and directed. |
| 21 | S&F in repair wall mounted LED light fitting 1x20 watts AC decorative box type with driver holder including LED tube light , energy efficient type 4 feet long including neccessary conection prewired and making connection with 3 core copper flexible cable of appropriate size from ceilling rose. |
| 22 | S&F LED in repair light fitting mirror type 2 ft long 10 watt ,220 V ACdecorative typewith driver holder including LED lamps and connection prewired and making connection with 3 core copper flexible cable of appropriate size from ceilling rose. |
| 23 | M&L for Distribution boarddouble door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, triple pole and neutral 415 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one. |
| 24 | M&L for Distribution boarddouble door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one. |
| 25 | M&L for Distribution boarddouble door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one. |
| 26 | M&Lfor Distribution boarddouble door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one. |
| 27 | S&F in repair sheet metal enclosure 2 way without bus barwithMCB , SPN 32 Amps 10 KA \"C\"Seriescomplete all as specified and directed. |
| 28 | S&F in repair Main Circuit breaker triple pole & neutral(TPN) 415 volt C curve 10 KA, 63 Amps capacity IP 20complete all as specified and directed. |
| 29 | S&F in repair Main Circuit breaker single pole & neutral (SPN) 240 volt C curve 10 KA 63 Amps capacity IP 20complete all as specified and directed. |
| 30 | S&F in repair main Circuit breaker single pole & neutral (SPN)240 volt C curve 10 KA 32 Amps capacity IP 20complete all as specified and directed. |
| 31 | S&F in repair Main Circuit breaker single pole (SP), 6 to 32 Amp (SP)240 volt B curve 10 KA, IP 20complete all as specified and directed incl taking down old one . |
| 32 | S&F in repair 6 Watt LED spot wall light ( Focus) Metal body complete all as specified and directed. |
| 33 | S& F in repair LED Adore Lamp 0.5 W B22 Green(Make :- Havells/ Bajaj/CG) |
| 34 | S& F in repair LED Adore Lamp 0.5 W B22 Red (Make :- Havells/ Bajaj/CG) |
| 35 | Supply only inrepair PVC insulatedunsheathed copper cable single core as per IS 694:1990 of following size (Make : Havells/Anchor/Polycab/KEI) |
| 36 | 1.5 Sq mm |
| 37 | 2.5 Sq mm |
| 38 | Supply & fix gang box polycarbonate type suitable for surface mounting with 5 Amp S/S combination Make: Anchor |
| 39 | S&F in repairtwo single core 4 sq mm for sub Main wiring with copper conductor multistranded PVC insulated and unsheathed 1100 Volts grade in and including PVC casing capping/ pvc conduit with fixing accessories including one run of 4.0 Sq mm copper conductor. (Note - Two runs of 04 Sq mm cable, one run of 4.0 Sq mm earth cable and one run of PVC casing Capping shall be measured as one running meter.) |
| 40 | S&F in repairtwo single core 6 sq mm for Sub Main wiring with copper conductor multistranded PVC insulated and unsheathed 1100 Volts grade in and including PVC casing capping/ pvc conduit with fixing accessories including one run of 6 Sq mm copper conductor. (Note - Two runs of 06 Sq mm cable, one run of 6 Sq mm earth cable and one run of PVC casing Capping shall be measured as one running meter.) |
| 41 | M&L for Repair/Rewinding of exhuast fan, 200 to 250 mm dia sweep complete including minor spare parts required for smooth operation of fan all as specified and directed .Note: cost includes taking down and refixing the same after repair. |
| 42 | M&L for Repair/Rewinding of exhuast fan, 300 mm dia sweep complete including minor spare parts required for smooth operation of fan all as specified and directed .Note: cost includes taking down and refixing the same after repair. |
| 43 | M&L for Repair/Rewinding of exhuast fan, 450 mm dia sweep complete including minor spare parts required for smooth operation of fan all as specified and directed .Note: cost includes taking down and refixing the same after repair. |
| 44 | S&F in repair casing and caping 25mm /PVC heavy dutyincluding all fixing accessories complete all as specified and directed. |
| 45 | S&F in repair casing and caping 32mm/PVC heavy dutyincluding all fixing accessories complete all as specified and directed. |
| 46 | S&F in repair flexible casing circular typecomplete all as specified and directed. |
| 47 | S&F in repairthermostat of size 175 mmfor Geyser complete all as specified. |
| 48 | S&F in repair Inner tank of stainless steel suitable for 25ltrs capacity geyser complete all as specified |
| 49 | S&F in repair Inner tank of stainless steel suitable for 50 ltrs capacity geyser complete all as specified |
| 50 | S&F in replacement heating element for hamam ( ISI marked) of capacity2 KW any type complete all as specified. |
| 51 | S&F in replacement heating element for heat pillars of capacity 750 watts to 1.5 KW complete all as specified. |
| 52 | S&F in repair Modular switch 6 Amp one way 240 Vas per sample all as directed by Engr- in- Charge |
| 53 | S&F in repair Modular switch 16 Amp one way 240 Vas per sample all as directed by Engr- in- Charge |
| 54 | S&F in repair Modular socket 6 Amp3 pin 240 Vas per sample all as directed by Engr- in- Charge |
| 55 | S&F in repair Modular socket 16 Amp 3 pin 240 Vas per sample all as directed by Engr- in- Charge |
| 56 | S&F in repair Modular plate with support frame 3 module complete as per sample all as directed by Engr- in- Charge |
| 57 | S&F in repair Modular plate with support frame 6 module complete as per sample all as directed by Engr- in- Charge |
| 58 | S&F in repair Modular plate with support frame 8 module complete as per sample all as directed by Engr- in- Charge |
| 59 | S&F in repair PVC gang box complete along with switch socket combination 15 Amp as required at site all as specified and directed by Engr- In- Charge |
| 60 | S&F in repair plug top 15 Amps,3 pin,230 volts complete all as specified. |
| 61 | S&F in repair plug top 5 Amps,3 pin,230 volts complete all as specified. |
| 62 | Supply fix in repair recess mounting LED panel 12 W 160mmX160mm luminaire white/worm powder coated CRCA housing with LED seamless front frame with flat white high transmission acrylic cover. |
| 63 | S&F in repair hylam sheet of size 20X10 CM 3mm thick, white complete all as specifed and directed by Engr-in-charge. |
| 64 | S&F in repair plastic body exhaust fan 250mm sweep AC, 240 Volts fixed as per manufacturer instruction, connection with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable including provn of hole and frame etc for fixing the fan as required at site complete all as specifed and directed by Engr-in-charge. |
| 65 | S&F in repair LED light fitting 10 Watt bulk head luminaire, complete with all accessories and including connection up with1.5 Sqmm three core copper conductor PVC insulated and PVC sheathed comete all as specfied and directed. |
| 66 | Deduct Credit for Demolished/Dismantled material Rs (-)59,445.00 (Minus) as listed in Schedule \"A\" Part-II (Credit Schedule)Note :Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the \"Contract Sum\". |