| 1 | Taking down carefully copper/ aluminium point wiring of light, fan, socket or power including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc.complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L for cutting chases, pinning in brick wall, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed by Engineer-in-Charge. |
| 3 | M&L for cutting chases, pinning in concreate/ stone wall, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed by Engineer-in-Charge. |
| 4 | M&L for point wiring with 1.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC casing and capping of suitable size, medium grade, ISI marked with all accessories such as bends, elbows reducers, pressed steel/ MS terminal boxes factory made 1.6 mm thick dully painted in rectangular shape appropriate size for one light/ fan point controlled by one 5 Amps switch one way, covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets requlators etc and continous PVC insulated and unsheathed 1.5 Sqmm copper conductor cable multistrand as earth wire complete all as specified and as directed. |
| 5 | All as per Item No. 04 above but 3 pin socket outlet, 5/6 Amp on Independent board. |
| 6 | All as per Item No. 04 above but 3 pin socket outlet, 5/6 Amp on same board. |
| 7 | All as per item No. 04 above but with 2.5 Sqmm cable for independent one 6 pin 6/ 16 Amps socket outlet in and including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 V grade IS - 694 FRLS cable for continuous earth wire. |
| 8 | S&F in repair switch piano 6 Amps, flush type, single pole, one way complete all as specified and as directed. |
| 9 | S&F in repair switch piano 16 amps, flush type, single pole, one way complete all as specified and as directed. |
| 10 | S&F in repair socket outlet, flush type, 5 pin, 6 Amps complete all as specified and as directed. |
| 11 | S&F in repair socket outlet 2 in 1, 5 pin, 16 Amps, flush type complete all as specified and as directed. |
| 12 | Supply and draw submain wiring with two single core 6.0 Sqmm FRLS PVC insulated copper cable 1100 Vots grade multistrand, unseathed conductor drawn into PVC casing caping and all necessary fittings including 6.0 Sqmm multistrand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete including taking down old unserviceable submain wiring of any size and making good disturbed surface complete all as specified and as directed.Note:- All runs of cable and one run of PVC casing caping shall be measured and paid as one unit of lenth. |
| 13 | All as per Item No.12 above but two single core 4.0 Sqmm for phase and neutral and 01 single core 4.0 Sqmm for earth wire. |
| 14 | All as per Item No.12 above but two single core 2.5 Sqmm for phase and neutral and 01 single core 2.5 Sqmm for earth wire. |
| 15 | All as per Item No.12 above but two single core 1.5 Sqmm for phase and neutral and 01 single core 1.5 Sqmm for earth wire. |
| 16 | M&L for point wiring with 1.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC conduit 20mm dia medium grade ISI marked with all accessories such as bends, elbows reducers, pressed steel/ MS terminal boxes factory made 1.6 mm thick dully painted in rectangular shape appropriate size (having wall thickness of conduit not less than 2.00 mm) for one light/ fan point controlled by one 5 Amps switch one way, covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets requlators etc and continous PVC insulated and unsheathed 1.5 Sqmm copper conductor cable multistrand as earth wire, complete all as specified.Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces shall be measured and paid under relevant items. |
| 17 | All as per Item No. 16 above but 3 pin socket outlet, 5 Amp on independent board. |
| 18 | All as per Item No. 16 above but 3 pin socket outlet, 5/ 6 Amp on same board. |
| 19 | All as per Item No. 16 above but with 2.5 Sqmm cable for Independent one 6 pin 6/ 16 Amps socket outlet In and including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 Volts grade IS-694 FRLS cable for continuous earth wire. |
| 20 | S&F in repair modular switches 6 amps single pole one way complete all as specified and as directed. |
| 21 | S&F in repair modular switches 16 Asingle pole one way complete all as specified and as directed. |
| 22 | S&F in repair modular socketes outlet6 amps 5 pin complete all as specified and as directed. |
| 23 | S&F in repair modular socket6-16 A, 3 pin combined ced shuttered complete all as specified and as directed. |
| 24 | Supply and fix in repair switch bell push flush type, 5 Amps, 240 Volts complete all as specified and as directed. |
| 25 | Supply and fix in repair call bell ding dong muscial type, AC, 230 Volts, single pole complete all as specified and as directed. |
| 26 | S&F in repair modular step fan speed regulator 5 steps, 120 W, 2 module complete all as specified and as directed. |
| 27 | S&F in repair steped type elecrtonic fan regulator, flush type complete all as specified and as directed. |
| 28 | S&F in repair ceiling rose polycarbonate, isolated body 65mm x 50 mm, 2 to 3 terminal complete all as specified and as directed. |
| 29 | S&F in repair modular type switch socket combination 16 A, 6 pin, 3 module with suitable box complete all as specified and as directed. |
| 30 | S&F in repair switch socket combination 3 pin 16 A, flush type with suitable box complete all as specified and as directed. |
| 31 | S&F in repair single pole and neutral sheet metal enclosure for 08 way DBs when SPN to be used single phase 240 Volts, double door complete all as specified and as directed.Note:- Quoted rates are inclusive for taking down old DBs of any type, cutting any type of walls for DBs fixing, connecting the existing connections with new DBs with suitable thimbles, connecting earth wire, removing the old debrises from site and making a good surface and match with existing surface complete. |
| 32 | S&F in repair single pole and neutral sheet metal enclosure for 12 way DBs when SPN to be used single phase 240 Volts, single door complete all as specified and as directed.Note:- Quoted rates are inclusive for taking down old DBs of any type, cutting any type of walls for DBs fixing, connecting the existing connections with new DBs with suitable thimbles, connecting earth wire, removing the old debrices from site and making a good surface and match with existing surface complete. |
| 33 | S&F in repair triple pole and neutral sheet metal enclosure for 04 way DBs when TPN to be used three phase 440 Volts, double door complete all as specified and as directed.Note:- Quoted rates are inclusive for taking down old DBs of any type, cutting any type of walls for DBs fixing, connecting the existing connections with new DBs with suitable thimbles, connecting earth wire, removing the old debrices from site and making a good surface and match with existing surface complete. |
| 34 | S&F in repair vertical TPN DB 4 way, modules - MCCB incomer and 4+4+4 TP outgoings with ready to use DBs, complete with colour - coded wire set, insulated vertical phase bus bars, neutral bar/s with shroud/s, earth bar/s, cement spill protector, cable ties, blanking plates, with provision for MCCB as incomer and SP/ TP MCBs as outgoings, suitable for 3P/ 4P MCCB as incomer upto 125A complete all as specified and as directed.Note:- Quoted rates are inclusive for taking down old DBs of any type, cutting any type of walls for DBs fixing, connecting the existing connections with new DBs with suitable thimbles, connecting earth wire, removing the old debrices from site and making a good surface and match with existing surface complete. |
| 35 | S&F in repair MCCB of capacity 125 Amps, 415 Volt, fixed type with breaking capacity 16 KA complete all as specified and as directed. |
| 36 | S&F in repair MCB of\"C\" series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of single pole 6 to 32 Amp complete all as specified and as directed. |
| 37 | S&F in repair MCBs of\"C\" series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of SPN 40 to 63 Amp complete all as specified and as directed. |
| 38 | S&F in repair MCB of\"C\" series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 40 to 100 Amp complete all as specified and as directed. |
| 39 | S&F in repiar LED pride Ultra Nxt Batten 36 W 6500 K cool white LED 4 feet tube light fitting 1x 36 W lumen upto 4000, 220 V, AC batten type connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 40 | S&F in repiar LED Pride Ultra Nxt Batten 25 W 6500 K cool white LED 4 feet tube light fitting 1x 36 W lumen upto 4000, 220 V, AC batten type connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 41 | S&F in repair elegant white colour ceiling fan of size 1200mm sweep, 3 blades, five speed, noise level upto 65 dB, single phase, 230 Volts, 50 HZ including removing old ceiling fan to store for safe custody complete all as specified and as directed.Note:- (i) Quoted rates are inclusive for down fan rod as per site, fan hook, necessary clamps, nut and bolts, grouting and refilling works complete. |
| 42 | S&F in repair 30 Watt CRYSTA NEO COB SWIVEL type recess mounted downlighter with pressure die-cast aluminium heat sink and clear PC as a cover in white powder coated finish with independent electronic LED driver cool white 6500K/ warm white 3000 K with high grade polycarbonate housing for better aesthetic appeal with edgeless diffuser duly connected with 0.5 Sqmm white colour PVC insulated and sheathed three core flexible multi stranded copper conductor cable complete all as specified and as directed. |
| 43 | S&F in repair precisely designed decorative ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with armstrong/ grid ceiling LED 36 W luminaire suitable for 2\" x 2\" grid ceiling with flat duly connected with 0.5 Sqmm white colour PVC insulated and sheathed three core flexible multi stranded copper conductor cable complete all as specified and as directed. |
| 44 | S&F in repair sheet metal enclosures with socket plug top and MCBs having single pole and nutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp 240 V complete all as specified and as directed. |
| 45 | S&F in repair metalic body round/ square type shutters suitable for upto 450 mm sweep exhaust fans, colour - Grey including removing old exhaust fan to store for safe custody complete all as specified and as directed. |
| 46 | S&F in repair steel wire mesh net mosquito alongwith aluminum frame, shape in round/ square type suitable for upto 450mm sweep exhaust fans, necessary fixing materials complete all as specified and as directed. |
| 47 | M&L for cutting holes 300mm/ 450mm diameter for preaparing opening through brick/ stone masonary wall for fixing exhaust fan 300mm/ 450mm sweep, making good to damaged surface of wall, make a smooth circular/ square surface and match with specification of existing wall complete all as specified and as directed by Engr-in-charge. |
| 48 | Supply, install, testing and commissioning 6 Way GI ring fountains outer header radious upto 18 feet, dia of ring as per exisiting 40/ 50 mm and GI ring fountains inner header radious up to 3 feet, dia of ring as per exisiting 40/ 50 mm including necessary fittings complete with following items:-Brass crown ring nozzels min 46 Nos for outer header and 18 Nos inner header, 6 Way MS/ SS central jet including suitable to fixing with outer and inner GI fountain ring, central raiser and also fix with existing open well pump/ motor with complete fittings, 18 Watt under water LED light with RGB effect SS (08 No\"s), armoued three core copper cable size 6 Sqmm, TPN MCB and suitable DOL three phase starter accommodate in CRCA sheet enclosure, repair of open well pump foundation, refreshing incoming connections complete all as specified and as directed. |
| 49 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with galvanizing iron and steel GI earth wire 4 mm dia by means of bolt nut check nuts and washers of galvanised iron, 15mm dia GI pipe, medium grade for protection to earth lead including PCC with (1:2:4) type B1 (using 20mm graded stone aggregates) CI frame and cover of angle iron 25 x 25 x 3 mm with 6 mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering, earthwork in any type of soil, returning filling in and removal of surplus soil to a distance n. exc. 50m all as per electric plate no.3 of SSR 2009 Part I connected to earth test point all as specified and indicated including testing on completion complete all as specified and as directed.Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth wire.(ii) Item includes the cost of 7.5 metre GI earth wire. |
| 50 | S&F in repair highly efficient IP 66 45 Watt LED street light/ building light with high power LEDs having aluminium pressure die-cast housig and PC lens cover along with suitable GI pipe bracket of 01 mtr length, nuts/ bolts and necessary clamps and control wiring from switch board to building light with armoured copper cable of size 1.5 Sqmm x 3 Core, including PVC conduit of suitable size complete as specified and as directed.Note:- Quoted rates are inclusive for necessary scaffolding for fixing of building lights and also where as specified and directed. |
| 51 | Supply, install, testing and commissioning in repair 6 way GI ring fountains outer header radious upto 20 feet, dia of ring as per exisiting 40/ 50 mm and GI ring fountains inner header radious up to 3 feet, dia of ring as per exisiting 40/ 50mm including necessary fittings complete with following items:-Brass crown ring nozzels min 50 Nos for outer header and 20 Nos inner header, 6 way MS/ SS central jet including suitable to fixing with outer and inner GI fountain ring, central raiser and also fix with existing open well pump/ motor with complete fittings, 18 Watt under water LED light with RGB effect SS (10 Nos), armoured three core copper cable size 6 Sqmm, TPN MCB and suitable DOL three phase starter accommodate in CRCA sheet enclosure, repair of open well pump foundation, refreshing incoming connections complete all as specified and as directed. |
| 52 | S&F in repair highly efficient 10 Watt IP 65 rated LED bollard with robust design and efficient light distribution including PCC foundation for bollard light and connecting with existing connections complete as specified and as directed.Note:- (i) quoted rates are inclusive for necessary PCC foundation.(b) Complete the necessary electrical connections suitable armoured three core copper cable including PVC conduit and earth work. |
| 53 | S&F in repair industrial type metal plug and socket 32 Amps, 3 pin, electrical rating 32 Amp, 3 Pin - 3P+1E), suitable for surface and flush mounting with CRCA sheet steel powder coated enclosure, MCB TPN 63 A, three phase metal socket and plug complete as specified and as directed.Note:- Quoted rates are inclusive for taking down old boards of any type, cutting any type of walls for board fixing, connecting the existing connections with new boards with suitable thimbles, connecting earth wire, removing the old debrises from site and making a good surface and match with existing surface complete. |
| 54 | Disconnecting HT/ LT cable of any size from the both ends of transformer, voltage stablizer, DG sets of capacity upto 125 kVA at Tech area, Salawas and Kaylana, taking down from plinth/ any type of structure, loading in to vehicle with the help of crane and transporting to MES store yard or where as directed by Engineer-in-Charge complete as specified and as directed.Note:- (i) Quoted rate is inclusive for suitable crane, plat top vehicle and necessary man power.(ii) Quoted rate is inclusive for clearing the way for mobility of vehicles into the installations for lifting of transformer, voltage stablizer, DG sets.(iii) Quoted rate is inclusive for after transporting of equipments installation must be clean upto the mark. |
| 55 | Disconnecting HT/ LT cable of any size from the both ends of transformer, voltage stablizer, DG sets of capacity up to 250 kVA at Tech area, Salawas and Kaylana, taking down from plinth/ any type of structure, loading into vehicle with the help of crane and transporting to MES store yard or where as directed by Engineer-in-Charge complete as specified and as directed.Note:- (i) Quoted rate is inclusive for suitable crane, plat top vehicle and necessary man power.(ii) Quoted rate is inclusive for clearing the way for mobility of vehicles into the installations for lifting of transformer, voltage stablizer, DG sets.(iii) Quoted rate is inclusive for after transporting of equipments installation must be clean upto the mark. |
| 56 | Disconnecting HT/ LT cable of any size from the both ends of transformer, voltage stablizer, DG sets of capacity upto 400 kVA at Tech area, Salawas and Kaylana, taking down from plinth/ any type of structure, loading in to vehicle with the help of crane and transporting to MES store yard or where as directed by Engineer-in-Charge complete as specified and as directed.Note:- (i) Quoted rate is inclusive for suitable crane, plat top vehicle and necessary man power.(ii) Quoted rate is inclusive for clearing the way for mobility of vehicles into the installations for lifting of transformer, voltage stablizer, DG sets.(iii) Quoted rate is inclusive for after transporting of equipments installation must be clean upto the mark. |
| 57 | Servising of diesel engine generating sets 15 to 50 KVA rating to be carried out as per schedulegiven as under. D - Check:- (perfomed on yearly basis or after running hours of 3000-5000 Hrs) (i) Complete DG set should be dismantle. (ii) Turbo charger service/ replace. (iii) Injector pin service. (iv) Cylinder head service. (v) PT pump service. (vi) Change oil. (vii) Change oil filter, fuel filter and bypass filter. (viii) Change water separator. (ix) Radiator cleaning with chemical. (x) Change of suitable size armored hose pipes with clips. (xi) Complete DG set engine should be dismantle of any number of cylinders by dismantling/ strip opening of the DG set for overhauling by removing the cylinder head assembly including facing and grinding, piston connecting rod, cylinder liner, oil sump and injector including replacement of worn out spare i.e. cylinder liner with \"O\" ring, piston assembly, connecting rod, large end bearing pair, valve seat, valve guide, FIP element, lubricant oil pump, gasket for cylinder, set of O rings, set of hose pipes, fuel pipes nozzle calibration, FIP calibration, water pump assy etc, ball bearing, nozzle and plunger for injector, bearing connecting rod,bearing main pair set (large end) standard, repair kit for water pump and other required accessories and reassembling the complete engine complete all as specified and as directed.Note:- (a) Necessary repair works, control wiring and materials shall be inclusive in the quoted rates. (b) Relavant spares included in the quoted rate. |
| 58 | All as per Item No. 57 above but DG set of capacity 62.5 kVA to 100 kVA. |
| 59 | All as per Item No. 57 above but DG set of capacity 100 kVA to 160 kVA. |
| 60 | All as per Item No. 57 above but DG set of capacity 160 kVA to 250 kVA. |
| 61 | All as per Item No. 57 above but DG set of capacity 250 kVA to 400 kVA. |
| 62 | Cleaining, over hauling and dismantling the sump cover cleaning complete, removing sludge, dust etc. and re-fixing, including replacement of sump gasket, nut and bolts and other required accessories of the DG Set of capacity 15 kVA to 50 kVA complete all as specified and as directed.Note:- Toping up engine oil shall be measured and paid separately. |
| 63 | All as per Item No. 62 above but DG set of capacity 62.5 kVA to 100 kVA. |
| 64 | All as per Item No. 62 above but DG set of capacity 100 kVA to 160 kVA. |
| 65 | All as per Item No. 62 above but DG set of capacity 160 kVA to 250 kVA. |
| 66 | All as per Item No. 62 above but DG set of capacity 250 kVA to 400 kVA. |
| 67 | Dismantling of defective alternator/ dynamo/ self starter from engine and supplying and fixing new alternator/ dynamo/ self starter 24 Volts DC make:- TVC Lucas or equivalent as approved by GE including replacement of worn out nuts, bolts mounting clamp etc. complete all as specified and as direceted. |
| 68 | Dismantling of self starter 24 Volt DC by disconnecting battery connection, taking out to civil workshop for carrying out following repair works and refixing including testing complete:- (i) Rewinding of armature and field coil (ii) Replacement of carbon brush and solenoid switch (iii) Replacement of gear assembly complete all as specified and as direceted. |
| 69 | Dismantling of self starter 12 Volt DC by disconnecting battery connection, taking out to civil workshop for carrying out following repair works and refixing including testing complete:- (i) Rewinding of armature and field coil. (ii) Replacement of carbon brush and solenoid switch. (iii) Replacement gear assembly complete all as specified and as direceted. |
| 70 | Taking down u/s battery 12 V 180 AH from the DG set and supply and install 12 V, 180 AH maintenance free battery including terminal clamps, copper terminal lead of suitable size/ length, battery stand complete testing and commissioning complete all as specified and as directed by Engr-in-Charge. |
| 71 | Replacement of automatic mains failure panel (AMF) along with CPRI approved sheet metal enclosure thickness not less than 3 mm including control wiring with suitable copper cables and thimbles, auto control switches (such as auto manual mode, single phase mode, DG/ EB bypass mode), suitable contactors, busbars and insulators with colour code, digital display system, fuses and timers, relay system complete for DG Set 15 kVA to 50 kVA and after replacement of AMF panel and necessary testing shall be carried out complete all as specified and as directed.Note:- (i) Quoted rates are inclusive for all required accessories which are necessary for replacement of AMF panel. (ii) Quoted rates are inclusive for PCC foundation, connecting with existing earth pits, connecting existing LT cable. |
| 72 | All as per Item No. 71 above but DG set of capacity 62.5 kVA to 100 kVA. |
| 73 | All as per Item No. 71 above but DG set of capacity 100 kVA to 160 kVA. |
| 74 | All as per Item No. 71 above but DG set of capacity 160 kVA to 250 kVA. |
| 75 | Taking down u/s battery 12 V, 150 AH from the DG set and supply and install 12 V, 150 AH maintenance free battery including terminal clamps, copper terminal lead of suitable size/ length, battery stand complete testing and commissioning complete all as specified and as directed by Engr-in-Charge. |
| 76 | Taking out FIP from DG set of capaicity 62.5 kVA to 100 kVA, transportation to authorised service centre for repair/ maintenance and refixing to DG set including replacement of necessary spare parts such as plunzers, governer kit with pin, nozzels, head ball guide kit, head sheet, rock rod, rollar bearing, oill seal, pistion and ring pin, joint kit and sleeves complete all as specified and as directed. |
| 77 | All as per Item No. 76 above but DG set of capacity 100 kVA to 160 kVA. |
| 78 | All as per Item No. 76 above but DG set of capacity 160 kVA to 250 kVA. |
| 79 | All as per Item No. 76 above but DG set of capacity 250 kVA to 400 kVA. |