| 1 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing cable management/ PVC conduit as required. |
| 2 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 3 | 2 x 4 sq.mm + 1 x 4 sq.mm earth wire |
| 4 | 4 x 6 sq.mm + 2 x 6 sq.mm earth wire |
| 5 | Supplying and fixing of following sizes of uPVC Cable ManagementSystem System along with accessories on surface including supply of fixing materials, internal couplers, joint covers, end caps, internal and external corners, dividers, cable retainers, angles tee etc fixing screws as required and connected to the existing CMS system (MK - Prestige 3D). |
| 6 | 170mm x 57mm |
| 7 | Supplying and fixing following size/modules, PVC box suitable for item No.2alongwith modular base & cover plate for modular switches in existing Cable management system etc as required. |
| 8 | 4 Module (White) with blank plate |
| 9 | 6 Module (Black) |
| 10 | Supplying and fixing followingmodular switch/socket on the existing modular plate & switch box including connections but excluding modular plate & swich box etc as required to suit item nos 2&3. |
| 11 | 15/16A switch (Black) - UPS |
| 12 | 6 pin 15/16A socket (Black)- UPS |
| 13 | 6A switch (white) - RAW |
| 14 | 6A socket (white)- RAW |
| 15 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 16 | 8 way , Double door |
| 17 | 12 way , Double door |
| 18 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | Single pole (25A-2Nos & 16A-16Nos) |
| 20 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 21 | 25A |
| 22 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 23 | 25/32A |
| 24 | Supplying & fixing of following sizes of uPVC trunking in surface along with all the required accessories as required. |
| 25 | 38x16mm |