| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 8 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. conduit as required. (ForNetwork LAN ) |
| 9 | 20mm |
| 10 | 25 mm |
| 11 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | 5/6 A switch |
| 13 | 15/16 A switch |
| 14 | 3 pin 5/6 A socket outlet |
| 15 | 6 pin 15/16 A socket outlet |
| 16 | Supplying and fixing of Modular Baseand cover plate in the existing modular metal boxes etc. as required. |
| 17 | 3 module |
| 18 | 12 Module |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 21 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 22 | Supplying andfixing PVC batten / Angle Holder including connectionsand minimum 14W Luminare etc. as required |
| 23 | Installation ofExhaust fan in the existing opening, including making good the the damage, connections, testing, commissioning etc as. Required. |
| 24 | Upto 450mm Sweep |
| 25 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 26 | Group C |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | 6 Way double Door |
| 29 | 12 way , Double door |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 31 | Single pole |
| 32 | Double Pole |
| 33 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | 40 A |
| 35 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 36 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required |
| 37 | Supply, Installation, Testing and Commissioning of ceiling fan with BrushLess Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, remote(preferably mobile app based) for speed control and all remainingaccessories including safety pin, nut bolts, washers, temperature rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fanSupply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 38 | LED Batten light (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025 Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 24 -26 watt |
| 39 | Supply of 24/ 25W IP65 Aluminium Casting Street light fitting 1\" pipe entry operating 230V/50hz AC. |
| 40 | Supplying, installation, Testing & Commissioning of 10W LED/ IP 65 aluminium die cast surface mounting type Bulk head fittingoperating in 230V / 50Hz Supply. |
| 41 | Supplying of low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame. 200mm /225mm 9\" with 1350RPM. Cat-III operating in 230V / 50Hz Supply |
| 42 | Supplying, installation, Testing & Commissioning ofwall mounting type LED Mirror Light fitting suitable for Wash basin mirror operating in 230V / 50Hz Supply. |
| 43 | Supplying of 300mmpropeller type heavy duty exhaust fan suitable for power house |
| 44 | Supply and installation of 400mm /High speed / High Airthrough 92m3 / wall mounting fan |
| 45 | Supplying, installation, Testing & Commissioning of of 22/24W LED surface / recessed , round/ square cool white panel Light |
| 46 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum powerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test reportfrom NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above. 30Watts |
| 47 | Supply and laying of CAT 6 STP cable for Network (Computers), Conductor: 23 AWG Solid Bare Copper, Central Separator: PE Cross Separator, Insulation: High Density Polyethylene, FR-PVC sheath Shielded cable – Indoor, in the existing pipeReputed make ( For Network LAN) |
| 48 | Supply and installation ofRJ45 connectors andSocket with modular plate with Box in open or in recess, complete for Network LAN (e.office)as required |
| 49 | Supply of 2 module metal box with 1 Module modular sheet for 25A SP Modular MCB and 2 module metal box with 2 Module modular sheet for 25A Modular Socket ( For Air Conditioners) |
| 50 | Charges for extending the depth and width of the existing cable trench by breaking the concrete to a size of 10\" width × 12\" depth, including plastering, to accommodate a 12\" width × 6mm thick chequered plate over the trench, complete. |
| 51 | Supply of 12\" width x 6mm thickness x 4 feet length Aluminium chequered plate, suitable to coverthe above trench (1 plate length is 1.219 Mtr) |
| 52 | Charges for dismantling existing wirings, fan, tube light, ceiling fan, exhaust fan etc. |
| 53 | Supply and installation of Suitable wall fixing clamp for fixing 25W LED street light. |
| 54 | Suppy and Installation of 100x 50 uPVC Trunking (Length 2 Meters) suitable for dressing existing Solarcables , power cables laid for Solar inverter, by removing existing trunking, connections etc. complete. |
| 55 | Supply and layingof 4core x 16sq.mm copper conductor flexible cable in the 100x50 PVC trunking by replacing existing wiring and old trunking for solar inverter from power ditribution panel, complete. |
| 56 | Supply and installation of D-Link DIR-3040 3000Mbps, Tri-Band Wi-Fi Router with Advanced Wi-Fi, Mesh & Fast Combined Wi-Fi speeds of up to 400 Mbps (2.4 GHz) + 866 Mbps (5 GHz) + 1733 Mbps (5 GHz) Gigabit Ethernet Ports |
| 57 | Lighthouse Tower |
| 58 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 59 | 2 x 1.5 sq.mm |
| 60 | 3 x 2.5 sq. mm |
| 61 | Supplying and fixing following size/ modules, GI / PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 62 | 6Module (100 x200mm) |
| 63 | 12 Module (200mmX150mm) |
| 64 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 65 | 5/6 A switch |
| 66 | 5/6A two way Switch |
| 67 | 15/16 A switch |
| 68 | 3 pin 5/6 A socket outlet |
| 69 | 6 pin 15/16 A socket outlet |
| 70 | Supplying and fixing modular blanking plate on the existing modular plate & Switch box excluding modular plate as required |
| 71 | Supplying andfixing 3 pin, 5A ceiling rose on the existing junction box / wooden block including connections etc. as required |
| 72 | Supplying andfixing PVC batten / Angle Holder including 14W luminare connections etc. as required |
| 73 | Supplying and fixing following way single pole and neutral (SPN) sheet Steel MCB distribution board 240 volt,on surface / recess complete with tined copper, bus bar, neutral bus bar, Earth Bar, Din bar, intercontinctions, powder painted including earthing extra as required (but without MCB RCCB isolator) |
| 74 | 6 Way Double Door |
| 75 | Supplying and Fixing 5A to 32A rating, 240V/415V, 10KA \" C\" curve miniarture Circuit Breaker Suitable forinductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 76 | Single Pole |
| 77 | Supplying and fixing of Single pole blanking plate in the existing MCB BD Complete etc as Required. |
| 78 | Supplying and fixing following rating double pole 240V, isolator in the existing MCB DB Complete with connections, testing and Commissioning etc as Required. |
| 79 | 40A |
| 80 | Supplying and fixing following rating, double pole( single Phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 81 | 25A |
| 82 | Earthing with GI earth pipe4.5Mtr long, 40mm dia including accessories and providing masonry Enclosure with cover plate having locking arrangement and watering pipe etc with Charcoal / coke and salt as required |
| 83 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 84 | Laying of one number PVC insulated and PVC Sheathed / XLPE power power cable of 1.1KV grade of following size direct in gound including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 85 | Upto 35 sq.mm |
| 86 | Laying of one number additional PVC insulated and PVC Sheathed / XLPE power power cable of 1.1KV grade of following size direct in gound in the same trench in one tier horizontal formationincluding excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 87 | Upto 35 sq.mm |
| 88 | Laying of one number PVC insulated and PVC Sheathed / XLPE power power cable of 1.1KV grade of following size in the existing RCC / HUME / METAL pipe as required |
| 89 | Upto 35 sq.mm |
| 90 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing masonry open duct |
| 91 | Upto 35 sq.mm |
| 92 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size onwall surface as required |
| 93 | Upto 35 sq.mm (Double Run on Surface) |
| 94 | supplying and fixing cable route marker with 10cm x 10cm x mm thick CI plate with inscription there onbolted / welded to 35mm x 35mm x 6mm angle iron, 60cm Long and fixing the same in the ground as required. |
| 95 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(For Road Crossing) |
| 96 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 97 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025 Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 24 -26 watt |
| 98 | Supply installation,testing and commissioning of 10W LED/ IP 65 aluminium die cast surface mounting type Bulk head fittingoperating in 230V / 50Hz Supply. |
| 99 | Supply installation,testing and commissioning of22/24W LED Surface or recessed Ceiling fitting operates230V /50Hz |
| 100 | Supply and installation of 400mm /High speed / High Airthrough 92m3 / wall mounting fan ( For Service room) |
| 101 | Supply and laying of double run of 2core x 6 Sq.mm copper conductor of 1.1KVarmouredPVC insulated / PVC sheathed XLPEUG cable as required. (Laying from Power house to Light house Top Service Roomone in service and another is as spare : 350 mtr for main Light.) ( Another run from power house to tower bottom for stair case lighting: 130Mtr) |
| 102 | Labour chargesfor removing exiting stair case wiring, UG cable Laid from tower top to Bottom, switch boxes, bulk head fittings etc in LH tower and the same may be handed over toLH incharges |
| 103 | Charges for core cutting of 100mm and 45mm diameter holes at each landing in the staircase, with an approximate depth of 300mm, for the installation of 12.2x32mm mini trunking for staircase lighting and 50x50mm cable management to accommodate a double run of 2-core x 6sq.mm underground cable from the tower bottom to the top. ( Approximately 15 holes required) |
| 104 | Charges for cutting thetiles approximately 3 meters in length, and making a 3\" hole at the tower bottom for routing the underground (UG) cable through a suitable PVC pipe. This includes laying a double run of 2core x 6sq.mm UG cable and 3-core x 2.5 sq.mm UG cable, and restoring the surface to its original condition. |
| 105 | Supply of 50x50mm UPVC cable management, each with a length of 2 meters, suitable for carrying a double run of 2-core x 6 sq.mm underground (UG) cable from the tower bottom to the top. |
| 106 | Supply of 12.5x32mm mini trunking, each with a length of 2 meters, suitable for wiring staircase lights on both sides from the tower bottom to the top. Wiring for allround Balcony at top of Lighthouse. |
| 107 | Supply of 12.5x32mm falt Teefor mini trunking at each Bulk Head fitting. |
| 108 | Supply of 12.5x32mm end cap for closing the mini trunking at bulk head fitting side. |
| 109 | Additional charges for making an trench for laying UG cables. As the lighthouse is located in a coastal area, it is challenging to dig for cable layingto the collapsing sand, dewatering requirements, and other associated difficulties. |
| 110 | Labour charges for fixing 50x50mm cable trunking from the tower bottom to the top through core-cut holes, using 8x35mm stainless steel (SS) screws and washers at 2-foot intervals, ensuring secure mounting on the lighthouse tower wall. The rate includes the high-risk job of installing the 50x50mm cable trunking, laying a double run of 2-core x 6 sq.mm underground (UG) cable, properly securing the UG cable with 18 SWG bare copper wire, and closing the 50x50mm cable trunking. |
| 111 | Labour charges for fixing 12.5x32mm mini cable trunking from the tower bottom to the top through core-cut holes, and all round balcony at top of Lihthouse and bottom of Lighthouse using 8x35mm stainless steel (SS) screws and washers at 2-foot intervals, ensuring secure mounting on the lighthouse tower wall using flat Tee, end cap. The rate includes the high-risk job of installing the 12.5x 32mm mini cable trunking, laying a 1.5sq.mm x 2core wire, 2.5 x 3core wire and closing the 12.5x32mm cable trunking. |
| 112 | Labour charges for removing paver blocks from the road, breaking the concrete below, laying a 120 mm dia (OD-120 mm & ID-103 mm nominal) pipe, and then restoring the surface by refilling, concreting, and relaying the paver blocks as per the original condition. |
| 113 | Additional charges for making an earth pit. As the lighthouse is located in a coastal area, it is challenging to dig for pipe earthing due to the collapsing sand, dewatering requirements, and other associated difficulties |
| 114 | Fabrication and Supplyof 16 SWG GI sheet for covering existing Lift cable, Automation cable, NAIS cableslaid from the tower bottom to the top, passing through each staircase landing. The sheet shall be properly bent to form a box-type enclosure suitable for covering cables. It shall have a minimum 1\" bend on both sides for screws to ensure proper fixing to the wall. The total dimensions of the box, including the side plates for wall fixing, shall be (25mmx127mmx330mmx127mmx25mm)25mm (1\" for making screws on wall) × 127mm (5\" height of the box from wall) × 330mm (13\" length of the box to cover PVC pipe and cables) × 127mm (5\" height of the box from wall )× 25mm (1\" for making screws on wall) |
| 115 | Applying one coat of Etch primer ( Special primer for GI sheet metals for prevent peeling paint) on both sides and two or more coating of syntheticenamel paint of approved brand same colour of existing colour of wall. |
| 116 | Labour charges for fixing the above-mentioned GI box over the PVC duct, PVC pipe, and UG cables for proper covering, using screws at a distance of 0.5 meters on both sides of the box from the tower bottom to the top. |
| 117 | Miscellaneous materials, such as Tape roll, SS Screws, SS washers, 18SWG bare copper for tieing UG cable, SS Clamps, round sheet, PVC Grip,flexible hose, etc for |
| 118 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 119 | 2 x 1.5 sq.mm |
| 120 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 121 | 12 way , Double door |
| 122 | Supplying and Fixing 5A to 32A rating, 240V/415V, 10KA \" C\" curve miniarture Circuit Breaker Suitable forinductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 123 | single pole |
| 124 | Double pole |
| 125 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 126 | 40 A |
| 127 | Laying of one number PVC insulated and PVC Sheathed / XLPE power power cable of 1.1KV grade of following size direct in gound including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 128 | Upto 35 sq.mm |
| 129 | Laying of one number additional PVC insulated and PVC Sheathed / XLPE power power cable of 1.1KV grade of following size direct in gound in the same trench in one tier horizontal formationincluding excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 130 | Upto 35 sq.mm |
| 131 | Laying of one number PVC insulated and PVC Sheathed / XLPE power power cable of 1.1KV grade of following size in the existing RCC / HUME / METAL pipe as required |
| 132 | Upto 35 sq.mm |
| 133 | supplying and fixing cable route marker with 10cm x 10cm x mm thick CI plate with inscription there onbolted / welded to 35mm x 35mm x 6mm angle iron, 60cm Long and fixing the same in the ground as required. |
| 134 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required (For Road Crossing) |
| 135 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 136 | Supply of 25W LEDGarden Cum Gate Light fitting of 2 inch pipe |
| 137 | Supply of 24/ 25W IP65 Aluminium Casting Street light fitting 1\" pipe entry operating 230V/50hz AC. |
| 138 | Supply of 2core x 2.5 sq.mm Copper conductor, 1.1KV armoured, PVC-insulated, PVC-sheathed XLPE underground (UG) cable as required, |
| 139 | Supply of 2core x 6 sq.mm Copper conductor, 1.1KV armoured, PVC-insulated, PVC-sheathed XLPE underground (UG) cable as required,( For service cable of NA-II Quarters : 60 Mtrs, Pump House 140 Mtrs) |
| 140 | Supply of Metal Modern Decorative Pendant Lights of LED Luminarie (Hanging Light) of warm white 5W to 10W suitable for Gazebo. |
| 141 | Supply of 40mm/10KG PVC Pipe for laying double run if 2core x2.5sq.mm UG cable from Groud to Junction box of the street Light Post. For 14 Nos Street light poles. |
| 142 | Supply of 250x 200 x105 SMC Box suitable to Keep 2 pole MCB inside ( Street Light: 14, Gate light:1) |
| 143 | Supply of 80mm dia 6mm thread SS U bolt with double nut, double washer on both side suitable to hold the 250 x200 x105mm SMC Box with street light pole.( 2 Nos required for Each box) therfore 14 Poles required 28 Nos. |
| 144 | Supply of PVC MCB Gang box of 2 Pole |
| 145 | Fabrication of a street light pole with an 80mm (3-inch) diameter C-Class GI pipe, 10 feet in height from Road level (Total 12 feet). The base is welded with a 10\" x 10\" x 6mm MS plate and gusset plates. The top of the pole features a 3\" x 1\" GI reducer, followed by a 3-foot length dual arm of 1\" C-Class pipe with a 45-degree bend of both arm |
| 146 | Civil masonry work involves excavating a pit measuring 1.5 ft × 1.5 ft × 2 ft deep. Plain Cement Concrete (PCC) of mix ratio 1:1.5:3 is laid at the bottom of the pit. A pole is then positioned on the PCC base, and concreting is carried out up to ground level. A 1.5 ft × 1.5 ft × 1.5 ft framework is fabricated for the above-ground portion of the concrete, incorporating a 40 mm PVC pipe for street cabling to the junction box. The framed box around the pole is then filled with concrete up to 1.5 ft above ground level, followed by plastering to complete the surface finish. (The work is inclusive of material, transport, labour etc.) |
| 147 | Labour charges for fixing the SMC box on a 3\" pole using SS U-bolts, followed by the installation of a 2-pole MCB with its PVC gang box. This includes mounting 2 Nos. street light fitting on top and laying a 2-core x 1.5 sq.mm wire from the junction box to the street lights. Additionally, it includes laying a double run of 2-core x 2.5 sq.mm UG cable inside a 40mm PVC pipe, along with connections, termination, installation of the 2 Nos. MCB, and all related work for completion. |
| 148 | Installion ofMetal Modern Decorative Pendant Lights of LED Luminarie (Hanging Light) 4 Nos. in each gazebo, followed by laying of 2 core x 1.5 sq.mm flexible un armed cable and termination from 2core x 2.5 sq.mm UG cable and 4 Nos junction Boxes etc. complete. |
| 149 | Supply and installation ofdecorative type 8 to 10 feetheight, alluminium casting powder coating Garden light pole with 10-15W LED Luminire dome on top with frosted glass, warm white,driver operates in 180V-230V AC with inbuit MCB/ isolator connector etc complete ( Inclusive civil masonry foundation work etc.) |
| 150 | Supply and installation ofdecorative type 300mm to 800mm height, alluminium casting powder coating Bollard with 6-10W LED Luminire dome on top with frostedglass, warm white,driver operates in 180V-230V ACconnector etc complete ( Inclusive civil masonry foundation work etc.) |
| 151 | Removing the old gate light fitting and installing a new gate light fitting in the existing location. Fixing the SMC box on the wall, making UG cable connections, and completing all related work. |
| 152 | Applying a single coat of primer on the civil masonry structure of the street light pole, followed by a double coat of post office red enamel paint. For the pole, applying a single coat of zinc chromate primer followed by a double coat of aluminum paint. The work includes all materials, labor, and complete. |
| 153 | Labour charges for removing the existing street light poles, including breaking the existing civil structure, excavating the earth, and removing concrete and the pipes. The removed materials shall be handed over to the Lighthouse in charge. |
| 154 | Labour charges for removing paver blocks from the road, breaking the concrete below, laying a 120 mm dia (OD-120 mm & ID-103 mm nominal) pipe, and then restoring the surface by refilling, concreting, and relaying the paver blocks as per the original condition. |
| 155 | Additional charges for making an trench for laying UG cables. As the lighthouse is located in a coastal area, it is challenging to dig for cable layingto the collapsing sand, dewatering requirements, and other associated difficulties. |
| 156 | Miscellaneous materials, such as Tape roll, SS Screws, PCV grips, flexible hose, etc. |