Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE ‘A’ PART - I.Supply & Constr of Prefabricated fast eractable modular shelter for Guard Room (5.22 m x 7.5m x 2.7 m height) including foundation, vetrified tiles flooring, ceiling,Internal and external Electfication & Furniture all as per Drg No. DGAR/COB/05), Sheet No. 1/11 to 11/11 |
| 2 | SCHEDULE ‘A’ PART - II.Supply & Constr of PFTS Six seated toilet block (PFTS 7.20 m x 2.20 m - qty 03 Nos) for 06 men including foundation, tiles flooring, minimum one EWS for each block, water tank staging,Water supply, Internal & external Electrification all as per Drg No. DGAR/COB/114, Sheet No. 1/3 to 3/3. |
| 3 | SCHEDULE ‘A’ PART - III.Supply & Constr of Prefabricated fast eractable modular Double storied (G+I) SM Bk (Size -22.50 m x 7.6 m) including foundation, vetrified tiles flooring, toilet and water suply fitting, Water Tank staging, Internal and external Electfication & Furniture all as per drg no. 6 Sect/Engr/57 sheet No. 1/2 to 2/2. |
| 4 | SCHEDULE ‘A’ PART - IV (Construction of Security fencing).Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all Kind of soil. |
| 5 | Providing and laying in position cement concrete of 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 7 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10cm length and drilling holes upto 10 mm dia. etc. complete. |
| 8 | Providing and fixing G.I. chain link fabric fencing made of G.I. wire of dia 4 mmof required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 9 | Extra for providing and fixing 40x 6 mm flat iron section for barbed wire |
| 10 | Painting with Two or more coats on new work aluminium paint of approved brand and manufacture to give an even shade. |
| 11 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre. |
| 12 | SCHEDULE ‘A’ PART - V(Repair & Maint of Bituminous Road).Scarifying metalled (water-bound) road surface including disposal of rubbish, lead upto 50 m and consolidation of the aggregate received from scarifying with power road roller of 8 to 10 tonne capacity. |
| 13 | Supplying and stacking at site 53 mm to 22.4 mm size stone aggregate |
| 14 | Supplying and stacking at site Moorum . |
| 15 | Laying, spreading and compacting 53 mm to 22.4 mm size stone aggregate to WBM with morum as binding materials including 11.2mm sizestone screening in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the reqd density.etc complete as per direction of Engineer - in - Charge. |
| 16 | Providing and applying tack coat using hot straight run bitumen of grade VG - 10 On W.B.M. @ 0.75 Kg / sqm, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. |
| 17 | 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). with paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt etc complete and all as per direction of Engineer - in - Charge. |
| 18 | Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete |
| 19 | SCHEDULE ‘A’ PART - VI (Construction of Retaining Wall).Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil. |
| 20 | Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level. |
| 21 | Providing and laying cement concrete of 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing. |
| 22 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 23 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like with Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 24 | Raised and cut Pointing on stone work with cement mortar 1:3 (1 cement : 3 sand) with raised and cut pointing. |
| 25 | Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete with 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 26 | Providing and fixing on wall unplasticised rigid PVC pipes 75 mm diain weep holes. |
| 27 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. |
| 28 | Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc |
| 29 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 30 | SCHEDULE ‘A’ PART - VII (Constructionof Storm Water Drainage).Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in All kinds of soil. |
| 31 | Providing and laying in position cement concrete of 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level. |
| 32 | Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.( For Drain Bed and wall) |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc |
| 34 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 35 | SCHEDULE ‘A’ PART - VIII (Construction of PCC Footpath).Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge in All kinds of soil. |
| 36 | Supply, stacking and Laying, spreading and compacting 63 mm to 45 mm size stone aggregate to WBM with morum as binding materials including 13.2mm sizestone screening in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the reqd density.etc complete as per direction of Engineer - in - Charge. |
| 37 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, all work up to plinth 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 38 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with Ordinary cement without any pigment |
| 39 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 40 | Finishing walls with Premium Acrylic Smooth exterior paint on new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)with Silicone additives of required shade. |
| 41 | SCHEDULE ‘A’ PART - IX (Addn/Altn of existing Cook House cum Dining Hall).Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand). |
| 42 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10 mm to 25 mm. |
| 43 | Providing and laying vitrified floor tiles in sizes 600mm x 600mm(thickness to be specified by the manufacturer) with water absorption less than 0.08%, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 44 | Supply and laying 25 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 45 | Providing and laying Polished Granite stone flooring in required design of Black,Cherry/Ruby Red or equivalent colour and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge |
| 46 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface |
| 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 48 | Providing and finishing with two or more coats applied @ 1.67 ltr/10 Sqm over existing cement paint surface Acrylic Smooth exterior paintwith silicon additives of required shadeincluding removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete. |
| 49 | Distempering with oil bound washable distemper approved brand and manufacturer to given an even shad in old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete. |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade,One or more coats on old work. |
| 51 | Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 52 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 53 | Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand) |
| 54 | Dismantling cement asbestos sheets or other hard board in ceiling,including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 55 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of G.S. Sheet. |
| 56 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below. |
| 57 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) |
| 58 | Providing and fixing of PPGI profile Sheet of 0.50mm (+0.05%) total coated thickness with zinc coating 120 gm per sqm in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scrateches during transportation and should be supplied single length upto 12m or as desired by Engineer - In - Charge . The sheets should be fixed using self drilling/ self tapping screws of size 5.5x55mm with EPDM seal, complete to the existing truss and purlins etc complete. |
| 59 | Providing and fixing PPGI sheet ridges or hips of width (500- 600mm) overall width plainsheet of 0.50 mm (+0.05%) total thickness , zinc coating fixed 120grms per sqm as per IS :277 using self drilling or self tapping screws complete. |
| 60 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete for Barge board (Upto 300 mm). |
| 61 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. |
| 62 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre laminated conforming to IS : 12823, Grade 1, Type - II mark. |
| 63 | Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. |
| 64 | Providing and fixing 100mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. |
| 65 | Providing and fixing 100x10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 66 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. |
| 67 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 25 mm dia (heavy type). |
| 68 | Providing and fixing 20 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge |
| 69 | Providing and fixing 25 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge |
| 70 | Providing and fixing 20mm nominal bore Gun metal Gate Valve with CI wheel of approved quality ( screwed end) |
| 71 | Providing and fixing 25 mm nominal bore Gun metal Gate Valve with CI wheel of approved quality ( screwed end) |
| 72 | Providing and fixing of 15mm nominal bore CP bib cock of approved quality. |
| 73 | Providing and fixing 15mm nominal bore C.P. brass angle valve for Basin mixer and geyser pointsof approved make conforming to IS:8931. |
| 74 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, incl painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 75 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 76 | Providing and fixing 32 mm dia, semi regid P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete |
| 77 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 78 | Providing and fixing of Stainless steeltowel rail ring trapezoidal shape 215mm long, 200mm wide with minium distances of 37mm from wall face with concesled fittings arrangement of approved qaulity of 600mm long. |
| 79 | Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia. |
| 80 | Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks. |
| 81 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group B) . |
| 82 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 83 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 84 | Supplying and fixing 5/6 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 85 | Supplying and fixing 15/16 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 86 | Supplying and fixing3 pin 5/6 amps Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 87 | Supplying and fixing 6 pin 15/16 amps Modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 88 | Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 89 | Supplying and fixing 3 Module (100mm x 75mm)following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 90 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 91 | Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 92 | Supply, fixing, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 93 | Supply, fixing, testing and commissioning of Exhaust fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 94 | Supply and fixing PVC batten/ angle holder including connection etc. as required. |
| 95 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 96 | Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 97 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 98 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 99 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required. |
| 100 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 101 | SCHEDULE OF CREDIT : Old UNSV false ceiling with wodden scantling etc complete. |
| 102 | Old UNSV CGI Sheet of various sizes |
| 103 | Old UNSV Doors , Windows including chowkhats of various sizes |
| 104 | Old UNSV GI pipe of 20 mm dia. |
| 105 | Old UNSV GI pipe of 25 mm dia. |
| 106 | Old UNSV Gun metal Gate valve 20 mm . |
| 107 | Old UNSV Gun metal Gate valve 25 mm . |
| 108 | Old UNSV Bib Cock 15 mm . |
| 109 | Old UNSV angle valve 15 mm . |
| 110 | Old UNSV Wash Hand basin with all fittings . |
| 111 | UNSV Looking mirror |
| 112 | UNSV Towel Rail CP |
| 113 | UNSV light points including ceiling rose, Holderes etc complete |
| 114 | UNSV Wire 2 x 4 Sqmm + 1 x 4 Sqmm earth wire |
| 115 | UNSV Wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 116 | UNSV switch and sockets 5 amp |
| 117 | UNSV switch and sockets 15 amp |
| 118 | SCHEDULE ‘A’ PART - X (Repair and maint of Store Shelter PFS-112).Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand). |
| 119 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 120 | Providing and laying vitrified floor tiles in600x600 mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 121 | Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (two or more coast applied @ 1.67 ltr/10 sqm) on existing cement paint surface |
| 122 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specificationon on Old work (one or more coats). |
| 123 | Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 124 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) . |
| 125 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 126 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). |
| 127 | Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 128 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of GS Sheet. |
| 129 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 130 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete of Ridges plain (500 - 600mm). |
| 131 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 132 | Renewal of old putty of glass panes (length) |
| 133 | Providing and fixing 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 134 | Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. |
| 135 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 136 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 137 | Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm. |
| 138 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 20 mm dia (heavy type). |
| 139 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group B) . |
| 140 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 141 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 142 | Supplying and fixing 5/6 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 143 | Supplying and fixing 15/16 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 144 | Supplying and fixing3 pin 5/6 amps Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 145 | Supplying and fixing 6 pin 15/16 amps Modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 146 | Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 147 | Supplying and fixing 3 Module (100mm x 75mm)following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 148 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 149 | Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 150 | Supply, fixing, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 151 | Supply and fixing PVC batten/ angle holder including connection etc. as required. |
| 152 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 153 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 154 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 155 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 156 | Supplying and fixing 40Amp, double pole, 240 V,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required |
| 157 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required. |
| 158 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 159 | SCHEDULE OF CREDIT : Old UNSV CGI Sheet of various sizes. |
| 160 | Old UNSV Doors , Windows including chowkhats of various sizes |
| 161 | UNSV light points including ceiling rose, Holderes etc complete |
| 162 | UNSV Wire 2 x 4 Sqmm + 1 x 4 Sqmm earth wire |
| 163 | UNSV Wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 164 | UNSV switch and sockets 5 amp |
| 165 | UNSV switch and sockets 15 amp |
| 166 | SCHEDULE ‘A’ PART - XI (Repair/maint of Single Men Barrack PFS-113).Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand). |
| 167 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 168 | Providing and laying vitrified floor tiles in600x600 mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 169 | Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (two or more coast applied @ 1.67 ltr/10 sqm) on existing cement paint surface |
| 170 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specificationon on Old work (one or more coats). |
| 171 | Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 172 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 173 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 174 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). |
| 175 | Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 176 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of GS Sheet. |
| 177 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mminterval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks). |
| 178 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 179 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete of Ridges plain (500 - 600mm). |
| 180 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 181 | Renewal of old putty of glass panes (length) |
| 182 | Providing and fixing 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 183 | Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. |
| 184 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 185 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 186 | Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm. |
| 187 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 20 mm dia (heavy type). |
| 188 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group B) . |
| 189 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 190 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 191 | Supplying and fixing 5/6 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 192 | Supplying and fixing 15/16 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 193 | Supplying and fixing3 pin 5/6 amps Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 194 | Supplying and fixing 6 pin 15/16 amps Modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 195 | Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 196 | Supplying and fixing 3 Module (100mm x 75mm)following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 197 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 198 | Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 199 | Supply, fixing, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 200 | Supply and fixing PVC batten/ angle holder including connection etc. as required. |
| 201 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 202 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 203 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 204 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 205 | Supplying and fixing 40Amp, double pole, 240 V,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required |
| 206 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required. |
| 207 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 208 | SCHEDULE OF CREDIT : Old UNSV CGI Sheet of various sizes. |
| 209 | Old UNSV Doors , Windows including chowkhats of various sizes |
| 210 | UNSV light points including ceiling rose, Holderes etc complete |
| 211 | UNSV Wire 2 x 4 Sqmm + 1 x 4 Sqmm earth wire |
| 212 | UNSV Wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 213 | UNSV switch and sockets 5 amp |
| 214 | UNSV switch and sockets 15 amp |
| 215 | SCHEDULE ‘A’ PART - XII (Repair/maint of Toilet Block PFS-114).Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand). |
| 216 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 217 | Providing and laying vitrified floor tiles in600x600 mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 218 | Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (two or more coast applied @ 1.67 ltr/10 sqm) on existing cement paint surface |
| 219 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specificationon on Old work (one or more coats). |
| 220 | Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 221 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 222 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 223 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). |
| 224 | Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 225 | Providing and fixing 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 226 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 227 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 228 | Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm. |
| 229 | Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge |
| 230 | Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge |
| 231 | Providing and fixing 20 mm nominal bore gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 232 | Providing and fixing 25 mm nominal bore gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 233 | Providing and fixing 15 mm nominal boreC.P. brass bib cock of approved quality conforming to IS:8931 |
| 234 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 of 15mm nominal bore. |
| 235 | Providing and fixing White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 236 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 237 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete, Semi rigid pipe 32 mm dia |
| 238 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 239 | Providing and fixing Stainless steel towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 240 | Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 241 | Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length, 15 mm nominal bore. |
| 242 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter |
| 243 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931, 15 mm nominal bore. |
| 244 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 245 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 246 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group B) . |
| 247 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 248 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 249 | Supplying and fixing 5/6 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 250 | Supplying and fixing 15/16 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 251 | Supplying and fixing3 pin 5/6 amps Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 252 | Supplying and fixing 6 pin 15/16 amps Modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 253 | Supplying and fixing 3 Module (100mm x 75mm)following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 254 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 255 | Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 256 | Supply, fixing, testing and commissioning of Exhaust fan, including wiring with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required of 450mm dia. |
| 257 | Supply and fixing PVC batten/ angle holder including connection etc. as required. |
| 258 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 259 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 260 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 261 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 262 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required. |
| 263 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 264 | SCHEDULE OF CREDIT : Old UNSV Doors , Windows including chowkhats of various sizes. |
| 265 | Old UNSV GI pipe of 20 mm dia. |
| 266 | Old UNSV GI pipe of 25 mm dia. |
| 267 | Old UNSV Gun metal Gate valve 20 mm . |
| 268 | Old UNSV Gun metal Gate valve 25 mm . |
| 269 | Old UNSV Bib Cock 15 mm . |
| 270 | Old UNSV angle valve 15 mm . |
| 271 | Old UNSV Wash Hand basin with all fittings . |
| 272 | UNSV PVC Water Tank 1000 ltr capacity |
| 273 | UNSV Towel Rail CP |
| 274 | UNSV light points including ceiling rose, Holderes etc complete |
| 275 | UNSV Wire 2 x 4 Sqmm + 1 x 4 Sqmm earth wire |
| 276 | UNSV Wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 277 | UNSV switch and sockets 5 amp |
| 278 | UNSV switch and sockets 15 amp |
| 279 | SCHEDULE ‘A’ PART - XIII (Repair/maint of Existing NCL SheltersPFS-116).Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand). |
| 280 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 281 | Providing and laying vitrified floor tiles in600x600 mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching pigments etc., complete. |
| 282 | Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (two or more coast applied @ 1.67 ltr/10 sqm) on existing cement paint surface |
| 283 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specificationon on Old work (one or more coats). |
| 284 | Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 285 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 286 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 287 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). |
| 288 | Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 289 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 290 | Renewal of old putty of glass panes (length) |
| 291 | Providing and fixing 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 292 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 293 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 294 | Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm. |
| 295 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets, 20 mm dia (heavy type) |
| 296 | Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge |
| 297 | Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge |
| 298 | Providing and fixing 20 mm nominal bore gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 299 | Providing and fixing 25 mm nominal bore gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 300 | Providing and fixing 15 mm nominal boreC.P. brass bib cock of approved quality conforming to IS:8931 |
| 301 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 of 15mm nominal bore. |
| 302 | Providing and fixing White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 303 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 304 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete, Semi rigid pipe 32 mm dia |
| 305 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 306 | Providing and fixing Stainless steel towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 307 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete ,10 litre capacity - White. |
| 308 | Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length, 15 mm nominal bore. |
| 309 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter |
| 310 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931, 15 mm nominal bore. |
| 311 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 312 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 313 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group B) . |
| 314 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 315 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 316 | Supplying and fixing 5/6 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 317 | Supplying and fixing 15/16 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 318 | Supplying and fixing3 pin 5/6 amps Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 319 | Supplying and fixing 6 pin 15/16 amps Modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 320 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 321 | Supplying and fixing 3 Module (100mm x 75mm)following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 322 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 323 | Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 324 | Supply, fixing, testing and commissioning of Ceiling fan, including wiring with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required of 450mm dia. |
| 325 | Supply and fixing PVC batten/ angle holder including connection etc. as required. |
| 326 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 327 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 328 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 329 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 330 | Supplying and fixing 40Amp, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 331 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required. |
| 332 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 333 | SCHEDULE OF CREDIT : Old UNSV Doors , Windows including chowkhats of various sizes. |
| 334 | Old UNSV GI pipe of 20 mm dia. |
| 335 | Old UNSV GI pipe of 25 mm dia. |
| 336 | Old UNSV Gun metal Gate valve 20 mm . |
| 337 | Old UNSV Gun metal Gate valve 25 mm . |
| 338 | Old UNSV Bib Cock 15 mm . |
| 339 | Old UNSV angle valve 15 mm . |
| 340 | Old UNSV Wash Hand basin with all fittings . |
| 341 | UNSV PVC Flushing Cistern |
| 342 | UNSV PVC Water Tank 500 ltr capacity |
| 343 | UNSV Towel Rail CP |
| 344 | UNSV light points including ceiling rose, Holderes etc complete |
| 345 | UNSV Wire 2 x 4 Sqmm + 1 x 4 Sqmm earth wire |
| 346 | UNSV Wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 347 | UNSV switch and sockets 5 amp |
| 348 | UNSV switch and sockets 15 amp |
| 349 | SCHEDULE ‘A’ PART - XIV (Repair/maint of CompanyCommander Resdence).Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand). |
| 350 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10 mm to 25 mm. |
| 351 | Providing and laying vitrified floor tiles in600x600 mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 352 | Providing and laying Vitrified tiles in 500x500 mm sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 353 | Providing and laying Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent sqm flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 354 | Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface . |
| 355 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 356 | Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (two or more coast applied @ 1.67 ltr/10 sqm) on existing cement paint surface |
| 357 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specificationon on Old work (one or more coats). |
| 358 | Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 359 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 360 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 361 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). |
| 362 | Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 363 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of G.S. Sheet. |
| 364 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below |
| 365 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 366 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete ,Ridges plain (500 - 600mm) |
| 367 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete for Barge board (Upto 300 mm) |
| 368 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 369 | Renewal of old putty of glass panes (length) |
| 370 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) of Kiln seasoned and chemically treated hollock wood. |
| 371 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately) with 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre laminated conforming to IS : 12823, Grade 1, Type - II marked |
| 372 | Providing and fixing 35 mm thick, Second class teak woodwire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wireof dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws |
| 373 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 374 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 375 | Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm. |
| 376 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets, 20 mm dia (heavy type) |
| 377 | Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc.with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 378 | Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in charge |
| 379 | Providing and fixing 200 mm stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. |
| 380 | Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete,Double strip (horizontal type) |
| 381 | Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge |
| 382 | Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge |
| 383 | Providing and fixing 25 mm nominal bore gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 384 | Providing and fixing 15 mm nominal boreC.P. brass bib cock of approved quality conforming to IS:8931 |
| 385 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 of 15mm nominal bore. |
| 386 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required |
| 387 | Providing and fixing White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 388 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 389 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete, Semi rigid pipe 32 mm dia |
| 390 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 391 | Providing and fixing Stainless steel towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 392 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter |
| 393 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 394 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group B) . |
| 395 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 396 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 397 | Supplying and fixing 5/6 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 398 | Supplying and fixing 15/16 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 399 | Supplying and fixing3 pin 5/6 amps Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 400 | Supplying and fixing 6 pin 15/16 amps Modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 401 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 402 | Supplying and fixing 3 Module (100mm x 75mm)following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 403 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 404 | Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 405 | Supply, fixing, testing and commissioning of Ceiling fan, including wiring with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required of 1200mm dia. |
| 406 | Supply, fixing, testing and commissioning of Exhaust fan, including wiring with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required of 450mm dia. |
| 407 | Supply and fixing PVC batten/ angle holder including connection etc. as required. |
| 408 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 409 | Supplying and fixing 8 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 410 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 411 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 412 | Supplying and fixing 63Amp, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 413 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required. |
| 414 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 415 | SCHEDULE OF CREDIT : Old UNSV GS Sheetof various sizes. |
| 416 | Old UNSV Doors , Windows including chowkhats of various sizes. |
| 417 | Old UNSV GI pipe of 20 mm dia. |
| 418 | Old UNSV GI pipe of 25 mm dia. |
| 419 | Old UNSV Gun metal Gate valve 20 mm . |
| 420 | Old UNSV Gun metal Gate valve 25 mm . |
| 421 | Old UNSV Bib Cock 15 mm . |
| 422 | Old UNSV angle valve 15 mm . |
| 423 | Old UNSV Wash Hand basin with all fittings . |
| 424 | UNSV PVC Flushing Cistern |
| 425 | UNSV PVC Flushing Cistern |
| 426 | UNSV Looking Mirror |
| 427 | UNSV Towel Rail CP |
| 428 | UNSV light points including ceiling rose, Holderes etc complete |
| 429 | UNSV Wire 2 x 4 Sqmm + 1 x 4 Sqmm earth wire |
| 430 | UNSV Wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 431 | UNSV switch and sockets 5 amp |
| 432 | UNSV switch and sockets 15 amp |
| 433 | SCHEDULE ‘A’ PART - XV (Repair/maint of PFTS Shelter (15 m x8m Bldg No. DSP/494 & 497).Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand). |
| 434 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 435 | Providing and laying vitrified floor tiles in600x600 mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 436 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 437 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 438 | Supply and laying Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level with Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 439 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) |
| 440 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 441 | Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (two or more coast applied @ 1.67 ltr/10 sqm) on existing cement paint surface |
| 442 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specificationon on Old work (one or more coats). |
| 443 | Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 444 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 445 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). |
| 446 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 447 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet |
| 448 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below |
| 449 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) |
| 450 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 451 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self apping screws completeRidges plain (500 - 600mm |
| 452 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self apping screws complete for Barge board (Upto 300 mm) |
| 453 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately Kiln seasoned and chemically treated hollock wood |
| 454 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made OFThree track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and singleglazing bead of appropriate dimension (Area of window upto 1.75 sqm). |
| 455 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately) with 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre laminated conforming to IS : 12823, Grade 1, Type - II marked |
| 456 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws , 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size , Second class teak wood |
| 457 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 458 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 459 | Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm. |
| 460 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets, 20 mm dia (heavy type) |
| 461 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group B) . |
| 462 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 463 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 464 | Supplying and fixing 5/6 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 465 | Supplying and fixing 15/16 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 466 | Supplying and fixing3 pin 5/6 amps Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 467 | Supplying and fixing 6 pin 15/16 amps Modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 468 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 469 | Supplying and fixing 3 Module (100mm x 75mm)following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 470 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 471 | Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 472 | Supply, fixing, testing and commissioning of Ceiling fan, including wiring with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required of 1200mm dia. |
| 473 | Supply and fixing PVC batten/ angle holder including connection etc. as required. |
| 474 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 475 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 476 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 477 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 478 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required. |
| 479 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 480 | SCHEDULE OF CREDIT : Old UNSV False Ceiling with wooden scantling . |
| 481 | Old UNSV GS Sheetof various sizes. |
| 482 | Old UNSV Doors , Windows including chowkhats of various sizes. |
| 483 | UNSV light points including ceiling rose, Holderes etc complete |
| 484 | UNSV Wire 2 x 4 Sqmm + 1 x 4 Sqmm earth wire |
| 485 | UNSV Wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 486 | UNSV switch and sockets 5 amp |
| 487 | UNSV switch and sockets 15 amp |
| 488 | SCHEDULE ‘A’ PART - XVI (Repair/maint of SM Bk and S/JCO accn PFTS Shelter (15 m x8m). Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand). |
| 489 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 490 | Providing and laying vitrified floor tiles in600x600 mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching pigments etc., complete. |
| 491 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 492 | Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (two or more coast applied @ 1.67 ltr/10 sqm) on existing cement paint surface |
| 493 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specificationon on Old work (one or more coats). |
| 494 | Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 495 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 496 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). |
| 497 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet |
| 498 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 499 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self apping screws completeRidges plain (500 - 600mm |
| 500 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 501 | Renewal of old putty of glass panes (length) |
| 502 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately Kiln seasoned and chemically treated hollock wood |
| 503 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately) with 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre laminated conforming to IS : 12823, Grade 1, Type - II marked |
| 504 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws , 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size , Second class teak wood |
| 505 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all completeWith 12 mm mild steel U beading |
| 506 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 507 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 508 | Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm. |
| 509 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets, 20 mm dia (heavy type) |
| 510 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group B) . |
| 511 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 512 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 513 | Supplying and fixing 5/6 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 514 | Supplying and fixing 15/16 amps Modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 515 | Supplying and fixing3 pin 5/6 amps Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 516 | Supplying and fixing 6 pin 15/16 amps Modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 517 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 518 | Supplying and fixing 3 Module (100mm x 75mm)following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 519 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 520 | Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 521 | Supply, fixing, testing and commissioning of Ceiling fan, including wiring with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required of 1200mm dia. |
| 522 | Supply and fixing PVC batten/ angle holder including connection etc. as required. |
| 523 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 524 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 525 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 526 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 527 | Supply and fixing 40 Amp Isolator, double pole, 240V in existingDB Complete. |
| 528 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required. |
| 529 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 530 | SCHEDULE OF CREDIT : Old UNSV GS Sheetof various sizes. |
| 531 | Old UNSV Doors , Windows including chowkhats of various sizes. |
| 532 | UNSV light points including ceiling rose, Holderes etc complete |
| 533 | UNSV Wire 2 x 4 Sqmm + 1 x 4 Sqmm earth wire |
| 534 | UNSV Wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 535 | UNSV switch and sockets 5 amp |
| 536 | UNSV switch and sockets 15 amp |
| 537 | SCHEDULE ‘A’ PART - XVII (Construction of Septic Tanks).Construction of 50 Users Setic Tank with brick wall in Cement mortar 1:6 (1 cement : 6 Coarse sand), PCC in two layers on bottomin Concrete 1:4:8 and 1:2:4 mix , Top RCC Slab in concrete mix 1:2:4, Neat cement plaster in Cement mortar 1:3 mix with water proofing compound mix in insideetc all complete as perdirection of Engineer - In - Charge and HQ DGAR Drg No. STD/ENGR/09, Sheet No - 1/1 . |
| 538 | Construction of20 Users Setic Tank with brick wall in Cement mortar 1:6 (1 cement : 6 Coarse sand), PCC in two layers on bottomin Concrete 1:4:8 and 1:2:4 mix , Top RCC Slab in concrete mix 1:2:4, Neat cement plaster in Cement mortar 1:3 mix with water proofing compound mix in insideetc all complete as perdirection of Engineer - In - Charge and HQ DGAR Drg No. STD/ENGR/09, Sheet No - 1/1 . |
| 539 | SCHEDULE ‘A’ PART - XVIII (Construction of Soak Pit and Chambers).Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 540 | Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design, Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 541 | Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia. |
| 542 | SCHEDULE ‘A’ PART - XIX (Site Development).Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge in all kinds of soil. |
| 543 | SCHEDULE ‘A’ PART - XX (Bore Well along with allied works).Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level, All types. |
| 544 | Boring/drilling bore well of 300 mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level All types of soil. |
| 545 | Boring/drilling bore well of 300 mm diafor casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto90 metre depth below ground level.(All types of soil) |
| 546 | Supplying, assembling, lowering and fixing in vertical position in bore well, 200 mm dia unplasticized PVC medium well casing (CM) pipe of required dia, conforming toIS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. |
| 547 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes 200 mm nominal dia with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 548 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer in-charge. |
| 549 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 550 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 551 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \"V\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 552 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia |
| 553 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I) of 200 mm dia |
| 554 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. of 200 mm clamp |
| 555 | Providing and fixing of Column pipe Heavy duty 50 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 556 | Supply, installation, testing and commissioning of 10 HP Submersible pump set, electric driven 415Volts, Three Phase suitable for 200 mm dia bore well (casing pipe size 200/150 mm) supply andcomplete inclusive of 10 meter long submersible cable and starter etc, all as per requirement and direction of Engr -in-Charge Make:Kirloslar andequivelant make). |
| 557 | Supply and fixing of Submersible cable water proof of size 10 sqmm three phase copper conductor including necessary connected items as per site requirement will be provided and as per direction of Engineer - in - charge ( Make - Havells/Finolex ) |
| 558 | Supply, installed, testing and commissioning of 10 HP Mono black centrifugal pump set 415V (Kirloskor) Model No KDS 822+3 Phase size 100 x 100 mm,including foundations of pumpset and motor including PCC and requirement of angle iron fitted with nuts and bolts having size 1 mtr x 1mtrx 0.4 mtr and allother necessary items as required at site for smooth running of pump and motor complete etc, all as per requirement and direction of Engr-in-Charge. . |
| 559 | Providing and fixing 50 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge |
| 560 | Providing and fixing 40 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge |
| 561 | Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge |
| 562 | Providing and fixing 50mm nominal bore gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 563 | Providing and fixing 40mm nominal bore gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 564 | Providing and fixing 25mm nominal bore gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 565 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in All kinds of soil. |
| 566 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 567 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 568 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand) |
| 569 | Supplying and stacking, Laying, spreading and compacting 63 mm to 45 mm size stone aggregate to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller at site. |
| 570 | Supply and laying 52 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer\"sspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 571 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 572 | Supply, installation , commissioning and testing of capacity 3000 Gallons per hour ( assuming iron contamination in said water approx 8 PPM with discharge of minimum 11000 LPH) . Iron removal plant complete of MS material body of minimum size 2.6 m in height and 2m in dia and approximate dimension of pressure tank etc with pressure filter media, catalytic media, air compressor, back washing facility, fully automatic, suitable size and power of electric monoblock pump motor with complete electric Panel and suitable starter & connection, water inlet/outlet connection pump to IRP and before completion to be submitted. installation water testing report from government/accredited laborratory and as per direction of Engineer - in - chrage. |
| 573 | Supply and fixing gravity feed gaseous chlorinator conforming to IS:10553, Part -4 with pump, motor, gauges having capacity 1 to 1000 gm per hour. |
| 574 | Supply and fixing Bleaching Dozer bucket type of capacity 105 ltr. |
| 575 | Supply, installation testing and commissioningof LT panel board outdoor type, fabricated out fo 3.15 mm thick MS sheet incl rain reviling system and painted with synthetic enamel paint two coats over a coat of red oxide primer and with following accessories incl internal wiring by using suitable size of copper conductor :-(i) MCCB 100 Amp TPN(incoming) :- 01 No (ii) MCCB 63 Amp TPN (Out going) :- 01 No(iii) Digital voltmeter 0 to 500 amp:- 01 Nos(iv) Digital voltmeter0 to 500 Vwith selectorswitchl: 01 nos(v) Stardelta starter suitablefor 10 HP submersible pump :- 01(vi) Single phase preventer :- 01 No(Testing will be done after completion) (vii) PCC foundation (size 2.0 x 3.0x 0.150 meter) 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20/40 mm nominal size), i/c necessary excavation etc, all as per requirement and direction of Engr-in-Charge.(viii) Over head roof & protection of CGI/ Corrigated sheet of appropriate size with slant and MS Sheet with mesh all around enclosure for protection from theft/ damage including lighting arrangement for illumination. |
| 576 | SCHEDULE ‘A’ PART - XXI (Provn and Upgradation of Existing Helipad Ground).Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m in All kinds of soil. |
| 577 | Providing and laying in position cement concrete of 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level. |
| 578 | Supply and fixing of LED Semi flush Heliport Light HLP-Z-20IP rating IP- 67, 20W, beam angle 120, Colour Green/Red/ Blue on off Cycle 50000 Hrs, Colour rendering index -80, PF 0.95, 230V, White aluminum treated dropforged dome and cast aluminum lower cover, Omnidirectional 8\" dia. The lens is mechanically clamped to the dome by means of astastening ring a customized lens gasket avoids the use of sealing. Replacement is quick and easy. No water builds up in front of the lens no optical adjustment is required after the replacement of the lamp filter or lenses. An O ring placed outside around the dome avoid dirt deposits between light unit and mounting assembly. |
| 579 | Supply and fixing of 4 Sqmm 3 core copper wire for connecton of Heliport light from Helipad to control panel. |
| 580 | Providing and fixing 50 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 581 | M&L for Cubical Panel board for Strobe lights, Semi Flush lights and flood lights near control room with following items (a) MCCB 63 Amp - 01 No (b) Ampere meter and voltmerter - 01 each (c) Dimmer for control 1000 watt - 06 No (d) MCB 32 Amp SP - 05 Nos (e) Sliding fuse - 01 No (f) RCCB 32 amp - 01 No with connected accessories etc complete all as specified and direction of Engineer - in - Charge. |
| 582 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 583 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 584 | Sypply and fixing of LED Heliport wind cone wind source with light HLP-WCL -1x20 Watt, Voltage 230 V, AC IP rating 67 on off cycles 50000 Hrs, Colour rating 80 Beam angle - 120 PF * 0.90 frequency 50Hz operating temp -20 to 50 degree centigrade colourwhite/Green/ Red/ Blue optical material, polycarbonate diffuser and Housing all non corrosive hard ware aluminum) with steel pole and all accessories required for wind cone. |
| 585 | Supply and fixing for 12 Volt DC Portable IR NVG Helipad light /Rappling light/ Night excersise light, Lighting Type Cluster of Power IR & Visible white LED designedoptices, Voltage 12V DC Battery, 11.1 Volt Rechargeable Lion life - 1 year, IP Rating Dust , water tight enclosure made from cold coated with corrosion resistant PU coat in Aviation Yellow, Weight approx 3.5 Kg (including Battery). |
| 586 | SCHEDULE ‘A’ PART - XXII (Installation of Hot Air Dryer 15KW Capacity).Supply only Industrial dryer 15 KW Capacity 3 Phase 415 Volt with Industrial dryer with starter Panel 3 Pahse 415 Volt with all accessories complete al as specified and directed by Engr - In - Charge. |
| 587 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) |
| 588 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 589 | Supplying and fixing modular 5/6 Amp switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 590 | Supplying and fixing modular 3 Pin 5/6 Amp socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 591 | Supplying and fixing modular 15/16 Amp switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 592 | Supplying and fixing modular 6 Pin 15/16 Amp socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 593 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.. |
| 594 | Supply and fixing20 watt LED pre-wired,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required. |
| 595 | Supply and fixingof exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required of 450 mm sweep |
| 596 | Supply and fixingLumiline NEO basic all purpose surface and wall mounted LED batten 20 Watt with polycarbonate housing and integrated electronic driver (Make - Havells - LUMILINENEOBS20WLED865SPCWH. |
| 597 | Supply and installation of LED flood light 50watts complete accessories. |
| 598 | Supply and fixing Exhaust Fan plastic body 300mm sweep Heavy duty 900 RPM |
| 599 | Supply and fixing of wall mounting fan 450mm sweep |
| 600 | Supply and fixing of Digital thermometer with sensor with connected items |
| 601 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 602 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 603 | Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 604 | Supplying and fixing 63 Amp rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 605 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Single poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required |
| 606 | Supply and fixing MCCB 160 Amp 4 Pole G frame 25KA with MCCB enclosure. |
| 607 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire. |
| 608 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 35 sq. mm and upto 95 sq. mm |
| 609 | Supply and laying Armoured XLPE cable insulated , screened PVC bedde galvanised steel strip or wire armoured electric power cables ( Heavy duty) with stranded aluminum conductor 1100 volts of size 3.5 Core 70 Sqmm. |
| 610 | Providing and fixing 50mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 611 | Providing and fixing 25mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 612 | Supply and fixning CPVC ball valve of 50 mm dia with all accessories. |
| 613 | Supply and fixning CPVC ball valve of 25 mm dia with all accessories. |
| 614 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 615 | Providing and fixing 15MM nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy