| 1 | Earthwork in excavation by manual means in trenches for foundation,drains, pipes, cables etc(not exceeding 1.5 mt in width)and for shafts,wells cesspits and the like not exceeding 10sqm on plan depth up to 1.5mt including disposal of excavated earth up to 1 mt from cutting edge disposed earth to be levelled and neatly dressed in. All kind of soil. |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.QUANTITY VIDE 4= 1.17 CUM @ 90 kg per cum. |
| 6 | Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation and plinth in Cement mortar 1 :6 ( 1 cement : 6 coarse sand) & Extra for brick work in superstructure above plinth level upto floor V level. (By manual means) |
| 7 | EXtra for brick work with common burnt clay bricks in super structuur above plinth up to floor five level quantity wide item no 6 |
| 8 | Centring and shuttering including strutting , propping etc. and removal of form work for Foundations , footings bases of columns etc. for mass concrete |
| 9 | Centring and shuttering including strutting , propping etc. and removal of form work for Suspended floors, roofs, landing, balconies and access plate form |
| 10 | Centring and Shuttering including strutting, propping etc and removal of form work for Edges of Slabs and Break in floors and walls (Under 20 cms wide) |
| 11 | 6mm cement plaster to ceiling of mix 1:3 ( 1 cement :3 fine sand). |
| 12 | 12 mm cement plaster of mix 1:6 ( 1 cement : 6 coarse sand) |
| 13 | 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand) |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 15 | Making plinth protection 50mm thick with cement conc .(1:3:6) ,20 mm nominal size of stone aggregates over 75mm bed of dry brick ballast,40mm nominal size of well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 16 | Painting with ready mixed synthetic enamel paint of approved brand and manufacture in all shades to give an even shade New steel work (two or more coats) |
| 17 | Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade |
| 18 | Finishing walls with water proofing cement paint of required shade New work (two or more coats) applied @ 3.84 kg/10 sqm |
| 19 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc.: INTERNAL WORK-Exposed on wall 15 mm dia. nominal bore medium |
| 20 | Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls INTERNAL WORK exposed on wall 20mm dia. Nominal bore medium. |
| 21 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid lSI license]. |
| 22 | Providing & fixing C.P brass angle valve for basin mixer and geyser points of approved make conforming to IS:8931 (15mm nominal bore) |
| 23 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 18.3.1 W.C. pan with ISI marked white solid plastic seat and lid. |
| 24 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings.Flat back wash basin of size 550x400 mm |
| 25 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back ,for the reception of pipes and fittings |
| 26 | Providing & fixing 1mm thick ms sheet door with frame of 40x40x6mm angle iron and 3mm gusset plate at the junction and corner all necessary fittings complete incliding prime coat of approoved brand |
| 27 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 28 | Providing and laying ceramic glazed floor tiles 300x300mm (thickness to be specified by the manufacturer) of Ist quality confirming to IS15622 of approoved make, laid on 20mm thick bed of cement mortar 1:4(1 cement:4 coarse sand) including pointing the joints with white cement and matching pigment etc. complete in all colours, shades, except white, ivory, fume red brown |
| 29 | Provide and laying in position cement concrete of specified grade excluding the cost of centering & shuttering.All works upto plinth level (1:2:4) grade with 20mm nominal size crushed aggregate. |
| 30 | Providing and fixing Ist quality ceramic glazed wall tiles confirming to IS:15622 (thickness to be specified by the manufacturer) of approoved make, in all colours, shades except burgundy, bottle green, black of any size as approoved by Enginne in charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar1:3(1 cement: 3 sand) and jointing with grey cement slurry@ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 31 | Providing and fixing electric points as per necessity at site |
| 32 | Providing and laying in position flow trap including all fittings, complete job. |
| 33 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Sand lead up to 5 KMS |
| 34 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Stone aggregate 20MM lead up to 5 KMS. |
| 35 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Bricks lead up to 5 km Please Enable Macros to View BoQ information |