| 1 | MAINTENANCE OF HIGH MAST |
| 2 | Supply Conveyance, installation, testing and commissioning of 200W LED Flood lightoutput greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHScompliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 3 | Supplying, installation, testing and commissioning of Astronomical time switchcapable of following output in feeder pillars/ Lighting DBs for automatic switching On&OFF of street lights at sun set & sun ruse or twilight override facility with12/24 hour display format with suitable battery and indication for relay status i/cprogramming at site complete ad required1 output per phase and suitable for singlephase supply level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 4 | INSULATION TAPE |
| 5 | NEUTRAL LINK |
| 6 | FUSE UNIT 32 AMPS |
| 7 | CONTACTOR 20/25 AMPS |
| 8 | 3 CORE 1.5 SQ MM COPPER WIRE |
| 9 | Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 10 | MAINTENANCE OF MINI MAST |
| 11 | Supply Conveyance, installation, testing and commissioning of 150W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 12 | Supplying, installation, testing and commissioning of Astronomical time switchcapable of following output in feeder pillars/ Lighting DBs for automatic switchingOn &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24hour display format with suitable battery and indication for relay status i/cprogramming at site complete ad required1 output per phase and suitable for singlephase supply |
| 13 | INSULATION TAPE |
| 14 | NEUTRAL LINK |
| 15 | FUSE UNIT 32 AMPS |
| 16 | CONTACTOR 20/25 AMPS |
| 17 | 3 CORE 1.5 SQ MM COPPER WIRE |
| 18 | Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps Please Enable Macros to View BoQ information |