| 1 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe,Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1) b) 4 SWG ;5.0 mtrs; 45 Kg |
| 2 | Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole CAP etc. Supplying & Fixing of G.I pole cap for suitable size |
| 3 | Painting steel tubular pole including projected arm bracket with one coat of red oxide primer and two coats with.silverlac AI.paint (Scraping where necessary). Pole painting upto 5mtr. Pole |
| 4 | Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole CAP etc. Supplying & Fixing of m.s. Sole plate (450x450x6m) atthe bottom of pole. |
| 5 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 6 1/2.80 2 |
| 6 | SCHEDULE OF RATES FOR EARTHINGINSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthingwith 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GIbolts, double nuts, double washers incl. S & F 15 mm dia GI pipeprotection (1 Mts. long) to be filled with bitumen partly under theground level and partly above ground level driven to an averagedepth of 3.65 Mts. below the ground level as below:(a)By ISI MediumGI pipe. |
| 7 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 124. 40mm GI pipe (ISI-Medium)A N N E X U R E - I Basic Rate of Materials: (All Rates of materialsfrom K-1 to K-14 are excluding VAT) 124. 40mm GI pipe(ISI-Medium) |
| 8 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materialsfrom K-1 to K-14 are excluding VAT) 184. MS Clamp (380x40x6mm) |
| 9 | Laying through Underground Trech.(a)Laying of one No. cable upto35 sqmm in underground trench 460 mm wide x 760 mm averagedepth, with brick protection on the top of the cable with 8 (eight) Nos.bricks per metre, including filling the space between the brick & cableand also the trench with shifted soil, leveling up and restoring surfaceduly rammed |
| 10 | Laying on Wall / surface with Saddles / clamps.(a)Laying of cableupto 2 core 25 sqmm on wall/surface incl. S & F MS saddles withearthing attachment in 10 SWG GI (HOT Dip) Wire, making holesetc. as necy. mending good damages and painting |
| 11 | BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS,GATES ETC. B. REPAIRING 2. Welding in M.S. structural work withgas or electric: (a) Tack weld |
| 12 | BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS,GATES ETC.3.Cutting to requisite length or shape departmental R.S.joists, channels, angles, tees, plates etc.( Payment to be made onarea of cut surface) |
| 13 | Fixing only TPN MCBDB in Sheet Steel enclosure (4 to 12 way) onflat iron frame on wall 415V TP/TPN |
| 14 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materialsfrom K-1 to K-14 are excluding VAT) 139. Galv. [Hot Dip] MS Flat |
| 15 | SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).Erection of Poles.Erection of Single Steel tubularpole of length as given below with/without sole plate & Cap etc. in CCfoundation (Proportion and dimension indicated below), having600x600x150 mm thick CC (4:2:1) base block below sole plate/polewith hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and0.30 mts. above ground level including 3 mm thick neat cementedfinish and GI earth bolt after making drilled holes etc. on pole &carriage of pole upto 1.6 Km from Store to work(site including fillingup the excavated earth pit with shifted soil and ramming properlyUpto9.0 mtr. Size 0.6x0.6x1.70 mts |
| 16 | SUPPLYING & DELIVERY OF SINTEX FRP WHITEWATERPROOF TYPE LOOPING CABLE BOX SIZE 300X200X125MM DEEP, 4 MM THICK , HAVING INSULATION RESISTANCEGREATER THAN 200 MEGA OHM, IP66; COMPRISING OF ONENO SPMCB, 4 NOS. TERMINAL CONNECTOR HAVING VOLTAGEGRADE OF 1.1 KV, ONE COMPRESSION TYPE BRASS CABLEGLAND FOR UPTO 4 CORE 16 SQMM PVC/A CABLE AS PERRATE OBTAINED FROM GEM PORTAL |
| 17 | SUPPLY AND INSTALLATION OF POLYVINYLIDENCE FLUORIDECOATED ALUMINIUM COMPOSITE PANEL BOARD (3MM) OFALUDECOR/ALSTONE SIZE (AS PER DRAWING) TO BE MADESUCH A MANNER THAT IT CAN BE OPENED TOWARDS UPDIRECTION FOR TAKING MAINTENANCE (USOR (M&E) , 2022 OFIRIGATION & WATER DEPT. , GOVT. OF WB (PAGE-127 , ITEM5.3L.1) |
| 18 | S & F ACRYLIC LETTER SCRIPTED IN ENGLISH/BENGALI SIZEAND MATTER OF LETTER AS PER APPROVED DRAWING BYEIC, FRONT SIDE OF THE LETTER TO BE MADE 6MM THICKIMPORTED (WHITE 0.40 UV STABILIZED EXCELLENT TO SELFDISPLAY. MAKE-ACAST, MITSUBISHI, ALL LETTER WILL BERAISED MINIMUM 2? TO BE FIXED BY SPECIAL TYPE OFSOLUTION. (TOTAL SQ. METER OFEACH LETTER IS TO BEMEASUSED BASED ON ITS FRONT SURFACE AREA) (USOR(M&E) , 2022 OF IRIGATION & WATER DEPT. , GOVT. OF WB )(PAGE-127 , ITEM 5.3L.2) |
| 19 | S& F LED LAMP INCL . BEST QUALITY LED LIGHTINGARRANGEMENT TO BE FIXED BY PROPER ARRANGEMENTWITH COMPLETE CONNECTION (1 MODULE CONTAIN 3 NOSLED , 0.5 EACH (USOR (M&E) , 2022 OF IRIGATION & WATERDEPT. , GOVT. OF WB )(PAGE-127 , ITEM 5.3L.3) |
| 20 | S& F WATER PROOF POWER SUPPLY SYSTEM IP 65, OUTVOLTAGE :12V/24V DC, 50/60 HZ FREQUENCY, 108 TO 305 VACPOWER SUPPLY> 0.95 POWER FACTOR FOR LED LAMP ( MAKE: MEAN WELL)200 WATT, MODEL ELG 200(USOR (M&E) , 2022 OF IRIGATION & WATER DEPT. , GOVT. OFWB )(PAGE-127 , ITEM 5.3L.4.4) |
| 21 | 26 GAUGE GALVANIZES IRON SHEET FOR BACK PANEL WITHONE COATING OF WHITE PAINT , MAKE- AARTI/BANSAL/JINDAL) (USOR (M&E) , 2022 OF IRIGATION & WATERDEPT. , GOVT. OF WB )(PAGE-127 , ITEM 5.3L.5) |
| 22 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materialsfrom K-1 to K-14 are excluding VAT) 121. 20mm dia GIpipe(ISI-Medium) |
| 23 | BUILDING WORKS(M) DRAIN, DOWN PIPES, CHIMNEY ETC?.(C).ADDITIONAL RATE?(21)Supplying, fitting & fixing UPVC pipes ATypeand fittings conforming to IS:13592-1992 with all necessaryclamps nails, including making holes in walls, floor etc. cuttingtrenches in any soil through masonry concrete structures etc ifnecessary and mending good damages including joining with jointingmaterails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A)UPVC Pipes:(ii) 110 mm. Dia. |
| 24 | Painting of any steel/ iron surface with no. of coats of paints as givenbelow with ready mixed paint/primer of(approved make and brandincl. preparation of surface by sand paper/emery paper, cleaning etc.FOR receiving fresh coat of paint (a) 1st coat of aluminium paint overone coat of RO priming |
| 25 | Painting of any steel/ iron surface with no. of coats of paints as givenbelow with ready mixed paint/primer of(approved make and brandincl. preparation of surface by sand paper/emery paper, cleaning etc.FOR receiving fresh coat of paint (b) 2nd coat of aluminium paint over1st coat |
| 26 | SUPPLY AND DELIVERY OF 150 WATT LED STREET LIGHT |
| 27 | Fixing only Floodlight fittings on top of masonary structure by 3 Nos.10 mm dia x 87 mm long rag bolts, nuts & double washers completeeither 37 mm x 10 mm MS flat support/or by other means as required |
| 28 | Sub Total |
| 29 | CGST 9% |
| 30 | SGST 9% |
| 31 | CESS 1% Please Enable Macros to View BoQ information |