| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed |
| 2 | Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed |
| 3 | Demolition of cement concreteof any description and in any position not otherwise specifically provided all as specified and as directed |
| 4 | M & L for Providing cement concrete in Roof kerb or Mud stope, rounded or chamfered on Edges type B1 1:2:4 (20 mm graded aggregate) as in Floor, filling and mass concrete including chicken wire Mess, water proofing compound no extra payment . |
| 5 | M & L for plain cement concrete type D2 1:4:8 (40 mm graded aggregate) as in foundations, filling and mass concrete all as specified and as directed. |
| 6 | M & L for plain cement concrete type C1 1:3:6 (20 mm graded aggregate) as in foundations, filling and mass concrete for embedding the vertical fencing posts all as specified and as directed. |
| 7 | Material and labour for walling random rubble, brought upto courses well bonded, bedded and solidly hearted, built in CM 1:4 complete all as specified and as directed by Engr-in-charge. |
| 8 | All as per ser item No.7 above but except stone all as specified and as directed. |
| 9 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, with maximum depression on face from straight edge held against the dressed surface n exc 40 mm, as specified, of random rubble walling, uncoursed or brought upto courses all as specified and as directed. |
| 10 | Material and labour for racking out joints/ pointing to random rubble or polygonal rubble uncoursed or brought up to courses built in cement mortar complete all as specified and as directed by Engr-in-charge. |
| 11 | Material and labour for flush pointing to random rubble mansonry, uncoursed or brought upto courses in CM 1:3 complete all as specified and as directed by Engr-in-charge. |
| 12 | Material and labour for old size brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean redius built in CM 1:4 complete all as specified and as directed by Engr-in-charge. |
| 13 | All as per ser item No 12 above but except bricks all as specified and as directed. |
| 14 | M&L PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in precast cement concrete louvers & jallies 50 mm thick including all moulding but excluding frame set & jointed in cement mortar 1:4 all as specified and as directed. |
| 15 | Taking down cement plaster from brick/concrete surfaces including raking out joints, hacking for key and scrubbing down with water etc all as specified and directed. |
| 16 | M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement all as specified and as directed. |
| 17 | Material and labour for cement concrete type B-0, 1:2:4 (Using 12.5 mm graded stone aggregates) for edging/coping complete all as specified and as directed by Engr-in-charge. |
| 18 | S & F mild steel work as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 19 | All as per item No.18 above but except steel all as specified and as directed. |
| 20 | S & F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 21 | All as per item No 20 above but except steel all as specified and as directed. |
| 22 | S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, dia of neck 5 to 10 mm all as specified and as directed. |
| 23 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of cement based paint white or tinted over a coat of chalk whitening primer complete all as specified and as directed by Engr-in-charge. |
| 24 | M & L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide prime all as specified and as directed. |
| 25 | Material and labour for one coat of synthetic enamel painting on old painted steel surfaces of any description, not otherwise described over 10cm width or girth including preparation complete all as specified and as directed by Engr-in-charge. |
| 26 | Removing existing piant by scrapping with truecare wall sander : L-01/H-01 (haviing mechanical vaccum mechanism) having RPM not less than 1500, standing pad 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc by skilled labour complete all as specified and as directed. |
| 27 | Providing and applying 1m thick waterproof cement based putty @ 1 kg per Sqm of Asian paints of its equivalent over the plastered/old painted wall after scrappingto prepare the surface even and smooth, complete all as specified and as directed. (Step 1 kg putty per minute). Step 2 ( Apply the first coat the prepared mixer with the help fully automatic airless spray machine of putty application of Asian Paints/Birla opus and equivelent spray Machine (Model : EH 230 DI) or equivalent having DC Electric Motor of 3.3KW having flow speed fo max 6 Ltrs per minutes with a maximum pressure 230 bar having maximum tip size 0.041\" or by manual. Step 3 (Allow 6-8 hrs time to dry the putty surface.Note :This items will be executed upto 6th floor on external surface. |
| 28 | Sanding of the putty surface with Asian Paints/Birla opus and equivelent truecare wall sander : L-01/H-01 (haviing mechanical vaccum mechanism) having RPM not less than 1500, standing pad 240 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc by skilled labour complete all as specified and as directed.Note :This items will be executed upto 6th floor on external surface. |
| 29 | Providing and applying one coat of acrylic waterbased interior/exterior grade primer @ 0.8 Ltr (undiluted)/10Sqm diluted with water in 1:1ratio to be applied with fully automatic airless spray machine of paint application of Asian Paints/Birla opus and equivelent trucare Graco or equivalent having an electric motor of min 1 HP wiht a flow speed ofmin1 Ltr per minute having a pressure of 3300 PSI Allow 6-8 Hrs to dry the surface fro painting of subsequent coats, complete all as specified and as directed.Note :This items will be executed upto 6th floor on external surface. |
| 30 | Providing and applying two coats of smooth acrylic emulsion with rich matt finish having voc less than 50 Grams per Ltr complying leed criteria @ 1 Ltrs (undiluted)/10Sq2 diluted with water in 2:1 ration applied over priming coat with fully automatic airless spray machine of paint application of Asian Paints/Birla opus and equivelent having an electric motor of min 1 HP with a flow speed of min 1 Ltr per minute having a presure of 3300 PSI allow 6-8 hrs to dry the surface in bioth the coats of paint, Complete all as specified and as directed |
| 31 | Note :- (a)(Application of Sr item No 27 to 30 here-in above) At the time of uploading bids each tendered shall upload a copy of MoU towards triparty agreement between tenderer, Manfacturer of Paints from Asian Paints/Birla opusand their Applicators for material and execution of work from any of the said Manfacturers. Financial Bids of only those bidders shall be admitted whosoever shall be upload a legitimate MOU.Note :This items will be executed upto 6th floor on external surface.(b) Terms of MOU so entered between tenders, Applicators and Manfutctures mentioned above shall also cover the guarntee from manfacturer of Paints for any defect in work executed by their applicators for a period of 5 Years. All other aspects with regard to payments or execution of work. |
| 32 | Note :-(c) (Applicable to Sr Item other than covered under Note 27 to 30 here -in-before). The necessary steel scafflonding upto G+3 Storeyed wherever required to executive the work shall be provided by the contractor with all safety equipments and the cost of providing scaffolding & safety equipments shall be deemed to be included in the quoted rates of the contractor and nothing extra shall beadmisible on this account.(d)The work shall be executed in AOR of AGE B/R-I and is being restricted area and head loss etc shall be considered before quonting the rates by the contractor as nothing extra shall be admissible on this account. |
| 33 | Demolition of cement concrete(unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or aboveground level) complete all as specified and as directed. |
| 34 | Dismantlingplain or corrugated steel/ fibre glass sheeting, any gauge, thickness, including Nainital or similar patter roof coverings complete all as specified and as directed. |
| 35 | M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. |
| 36 | S & F prepainted galvalume alume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and as directed. |
| 37 | S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 W (Gde E-250) Quality A complete all as specified and as directed. |
| 38 | M&L for 100 thick PCC 1:4:8 type D-2 (40 mm graded stone agg ) as in sub base complete all as specified and directed. |
| 39 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 40 | M&L for preparation of old brick, stone and concrete surfacesexceeding 10 cms width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed. |
| 41 | M&L for Durastone heavy duty vitrified tiles 10 mm thick Sq/rectangular tiles area of each tile not exceeding 0.36 Sqm as in floors set and jointed in neat cement slurry and pointed in clooured cement to match the surface over 15mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 42 | (i) M&L for prepration of surface by scrappind and properly cleaning the existing roof treatment in any number of layers up to original RCC roof top surface. Apply first coat fiber reinforced elastomeric liquid water proofing membrane formulated withPU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shall resist 10 bars of hydrostatics pressure reduce surface temperature upto 10 degree celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry. apply second of undiluted coat @ 0.45ltr/sqm. apply third and final coat undiluted @.45ltr/sqm as directed by Engr-incharge.(ii) M&L For 10mm thick cement rendering in CM 1:3 and finishing the surface even and smooth before application of priming coat complete, all as specified and as directed. |
| 43 | Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, smartcare ultra Block 2K or approved equivalent, having>220% elongation as per ASTM D 2370, resisting 5 bars hyrostatics pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 3.5mm as per EN 1062. The coating shall have food grade certificate from laboratories like CFTRI. the mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing etc., complete as per manufacturers specification.minimum consumption shall be 2Kg/sqm. supply and applying bond coat application mix AP SC repair polymer and cement in ratio of 1:1. brush apply 1 or 2 continuous coat of mix and ensure minimum consumption shall be 0.2 Kh/Sqm. |