| 1 | M/L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil all as specifed and directed |
| 2 | M&L for rendering 15mm thick on fair faces of concrete surfaces in CM 1:4 and finishedeven and smooth without using extra cement |
| 3 | Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all specified and directed |
| 4 | Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surfaceall as specified and directed |
| 5 | M/L of 75 mm thick Cementconcrete type B-1, 1:2:4 (20mm graded aggregate) as sub baseall as specified and directed |
| 6 | M/L of 20mm thick Screed bed or bedding layer of mortar 1:6 cmall as specified and directed |
| 7 | M/L of 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 8 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, includingfixing the railing with necessary accessoriesstainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor orthe side of waist slab with suitable arrangementincluding ss chain all as specified and directed |
| 9 | Supply & Fixing rotational moulded polythene water storage tanks of 500 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-1 including 20mm Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe/CPVC pipe complete all as specified. |
| 10 | Supplying and laying of 20mm OD CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 11 | Supply & Fixing 20mm OD CPVC tank adapter complete all as specified. |
| 12 | Supply & Fixing 20mm OD CPVC UNION complete all as specified. |
| 13 | Supply & Fixing 20mm OD CPVC Ball Valve complete all as specified. |
| 14 | Supply & Fixing 20mm OD male brass threaded adapter (MTA/MBTA) complete all as specified. |
| 15 | Supply & Fixing 20mm OD female brass threaded adapter (FTA/FBTA) complete all as specified. |
| 16 | M&L forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM1:6 complete all as specified and directed. |
| 17 | M&L for rendering 15 mm thick cement plaster in CM 1:4, (5mm thick with WP compound/liquid as per manufacturer\"s instruction over 10 mm thick plaster in two layer) on brick work or concrete surfaces on walls and finishing even and smooth without using extracementand applying Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete all as specified and directed. (WPC will be paid separately) |
| 18 | Supply only liquid water proofing compound. |
| 19 | S&F Flag Mast pole along with tricolour Indian flag having octagonal pole not less than 22 mtr height white colour30ft x 20 ft customised with PU paint hot dipped galavanised includingprovision for lowering and raising with motor as well as double drum winch having rope 6mm dia galvanised wire rope and control panel fir reversing operation of power tools .Note : foundation , bolts , anchor plate and other templates as required fo installation of flag mast is deemed to be included in the price |
| 20 | Supply and fixing PVC insulated copper flexible cable2.5 Sqmm 3 core, 1100 volts grade complete all as specified and directed. |
| 21 | Supply and fixing LED flood light 200 watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66protection, with impact and corrosion resistantcomplete with driver and lamp Complete all as specified and directed |
| 22 | M&LforRigid non metallic PVC conduit ISI marked, medium grade, inclusive of all fitting such as tees,bends. Junction boxes, elbows saddles. Pipe hooks,couples and lock outs etc 20 mm external dia, fixed as required complete and making good disturbedsurfaces in repairs all as directed. |
| 23 | S & F MCB SP 6-32 Amps, \"C\" series, 240 V complete incl making conections all as specified and directed. |
| 24 | S & FMCB SPN 32Amps, \"C\" series, 240 V complete incl making conections all as specified and directed. |
| 25 | S & FMCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existingcomplete all as specified and directed. |
| 26 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / layingunder ground electric cable including taking out old bricks from trenches and separating serviceable bricks and set aside for reuse complete all as specified and as directed. |
| 27 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed. |
| 28 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 29 | Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified. |
| 30 | M&L for brick protection cover on cable with sub class \"B\" brick laid dry flat adjacent to each other complete all as specified and directed. |
| 31 | Supply and fixingof GI tubing, light grade, 32 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete. |
| 32 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed. |
| 33 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 4 core x 25 Sqmm |
| 34 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 2 core x 10 Sqmm |
| 35 | Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for0.4 mpa working pressure. |
| 36 | Supply and fixing of Nature switch (using infrared sensor technology )based automatic street light control panel .This panel should be suitable enough to 3 phase load of 5 KW.Nature switch operation should be based on natural light lux level .Required illuminance level for switching ON is < 60 Lux & for switching off > 10 lux .The sensor alongwith suitable power contactors and incoming outgoing MCB should be enclosed in a pole /wall mounted rust proof ,electric shock ,termite proof and FR grade SMC Enclosure conforming to IP 54 ,The circuit should also have aprovision for manual operation (i.e sensor bypass option ) .The nature switch must have3 phase load of 5 KW (swadeep 02EC-5kW3p with 3 nos incoming outgoing MCBs of 16 -20 Amps & 3 nos contactors (single pole /2/ pole/3 pole ) of 16-20 Amps & circuit wiring (copper )10 mm2 complete all as specified and as directecd :Make : Swadeep |
| 37 | S&F PVC Junction box of size 255X200X100mm inside dimension fixed on pole by means of mild steel clamps with hinged door,bolt and nuts, provn for cable entry for incoming and outgoing including MCB 2.5 amps-1 No and 4 way connector-1nos neccessary connection duly fixed with clamps on pole and including cable glands threaded type IP55/IP65 made of polymide with lock nut complete all as specified.Make : Sintex GSJB2520 or equivalent in HAVELLS/ POLYCON. |
| 38 | M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specifiedand directed by Engr -in -charge for One light point / one bell point controlled by one, one fan point controlled by one, one way switch. |
| 39 | All asper Item No.38 above butfor One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch |
| 40 | All asper Item No.38 above but wiring complete with 2.5 sqmmfor One 3/5 pin, 15/16 Amps socket outlet point on independent board controlled by one , one way 15/16 Amps switch |
| 41 | All as per item No.38 above but wiring complete with 4Sqmm for AC point |
| 42 | All asper Item No.38 above butfor One 3 pin, 05 Amps socket outlet point on same board controlled by one , one way 05/06 Amps switch |
| 43 | Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed |
| 44 | S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed. |
| 45 | Supply & fixing modular switch 16 Amps 1 modulecomplete all as specified & directed |
| 46 | S & F in modular socket 06/16 Amps 2/3 pin combined 2 modulecomplete all as specified & directed. |
| 47 | S&F in repairLED PC batten light fitting of 4 feet 20 watt, with energy efficient LED and integrated electronic driver of 20W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. |
| 48 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 49 | S & F in repair MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces complete all as specified and directed. |
| 50 | S & F in repair MCB TPN 63 Amps incl making connections all as specified and directed. Make -Havellsor equivalent |
| 51 | S&F Celing Fan complete with blades , down rods ,elcetrinic regulator and acessories , 230 volts, 1200 mm sweep , min air delevery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed. |
| 52 | Supply and fixexhaust fan made ofsturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of250 mm sweepcompleteall as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 53 | Supply & Fix MCCB TPN 415 Volts 63 Amps rating with breaking capacity of 35 kA with adjustable thermal & magnetic release complete with making all connections as per site requirement as specified and directed. (Make : Havells / L&T/ Legrand) |
| 54 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / layingunder ground electric cable including taking out old bricks from trenches and separating serviceable bricks and set aside for reuse complete all as specified and as directed. |
| 55 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed. |
| 56 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 57 | Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified. |
| 58 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 3.5 core x 25 Sqmm complete all as specified and directed. |
| 59 | Ditto All as per Srl item No 58 here in above but size of cable 35 Sqmm 3.5 core |
| 60 | Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for0.4 mpa working pressure. |
| 61 | Supply and fixing in repairPVC insulated cableof size 50 sqmm, 1100Volts grade with multistrand copper conductors all as specified and directed. |
| 62 | Supply & fixing copper earth strip of size 20.0 x 3.0 mmwith saddles and fixing screws etc .for roof condutors and down conductors above ground levelall as specified. |
| 63 | Supply & laying in ground GI tubing light grade 40mm bore dia including necesary fittings for protecting earth continuity strip all as specified. |
| 64 | Supply & laying in ground GI tubing light grade 25mm bore dia including necessary fittings for protecting earth continuity strip. |
| 65 | Taking down perishedHigh density polyethylene (HDPE) pipe and supply & layingthe High density polyethylene (HDPE) pipe of50 mm bore complete including necessary fittings. |
| 66 | Cutting existing hard standing/flooring not exceeding600mm width x 600mmdepthall as specified as directed. |
| 67 | M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed. |
| 68 | Material and labour for maintenance free ring earth consisting of four earth pits spacing of minimum 4 mts andusing copper -bonded steel rods, compression couplers earth enanching compound and exothermic welding for interconnecting the four earth pit electrodes. Each earth pit consists of 17.2mm copper bonded steel coredelectrodes 10ft long -04 Nos, Earth enhancing compound of 10 kg bag -16 Nos, 25mm x 2mm copper strip -16 mts , including inspection chamber of size 30cmx30cmcomplete all as specified and directed by Eng - in- Charge. Note :(1) On testing after completion of Job , if desired earth resistence (Less than1 Ohm )is not obtained , the earthing shall be redone by the contractor without any cost to Govt. (2) The chemical earthing will be done by the manufacturer or its authorised representative on the site. (3) This item includes the cost of 25mm x 5mm x300mm copper bus bar - 1 No. (4) This item includes the cost of 25mmx 25mm x 150mm bus bar- 1No (5)Earth conductor beyond 7.5 Mts shall be measured andpaid seprately. |
| 69 | Material and labour for maintenance free earth consisting of one earth pits using copper -bonded steel rods, compression couplers earth enanching compound and exothermic welding for connectingpit electrodes to strip . Each earth pit consists of 17.2mm copper bonded steel coredelectrodes 10ft long -01 Nos, Earth enhancing compound of 10 kg bag -5 Nos, 25mm x 2mm copper strip -7.5 mts , including inspection chamber of size 30cmx30cmcomplete all as specified and directed by Engr - in- Charge. Note :(1) On testing after completion of Job , if desired earth resistence (Less than1 Ohm )is not obtained , the earthing shall be redone by the contractor without any cost to Govt. (2) The chemical earthing will be done by the manufacturer or its authorised representative on the site. (3) This item includes the cost of 25mm x 5mm x300mm copper bus bar - 1 No. (4) This item includes the cost of 25mmx 25mm x 150mm bus bar- 1No (5)Earth conductor beyond 7.5 Mts shall be measured andpaid seprately. |
| 70 | M&L to carry out earth resistance tests with the help of earth resistance tester digital/analog as per fall of potential meth. Mentioned in IS 3043and write the derived reading on the Earth Identification plate all as directed. |
| 71 | S& F Display board (Earth pit marker) made out of25 mm angular frame with 45 cm height one side welded with 2mm thick MS sheet, frame work of size 15cmx15cm including excavation , PCC foundation and duly painted with redoxide & two coatsblack enamel paint with following letterdisplay with white paint earth pit marker.a) Earthing pit No:- b) Earthing resistance:- c) E-N volt:-d) Check done on:- e) Check due On:- |
| 72 | M&L for Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m |
| 73 | M&L for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existingwork, complete |
| 74 | M&L Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of new surfaces complete all as specified and directed. |
| 75 | M&L for Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, depth of embedded portion of holdfast exc half brick but not exc one brick complete all as directed. |
| 76 | S&F Framed work such as grills, gratings, framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as directed. |
| 77 | S&FMild steel, plain, black sheet 1.60mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required |
| 78 | M&L two coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described above priming coat of red oxide including prepration of previously untreated surfaces. |
| 79 | M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out soft/loose soil and removing excavated material exc. 250 but not exc. 500m and deposited where directed. |
| 80 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor. |
| 81 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified. |
| 82 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 83 | M&L Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as specified and directed. |
| 84 | Providing and fixing 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish and apply a coat of distemper as required (Frame work for ceiling shall be measured and paid separately)complete all as specified and directed. |
| 85 | Material and labour preparation of newly surface of Ceiling and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coats on new work complete all as specified. |
| 86 | M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc,including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size continuousearth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for one 15 /16 Amps socket outlet point on independent |
| 87 | S & Felectronic fan regulator modular type, 2 module, 120Wincluding complete all as specified and directed. |
| 88 | Supply & fixingof ceiling rose surfacethree terminals in replacement of old u/s complete all as specified & directed. |
| 89 | M & L for sub main wiring complete with two runs of 2.5 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Note:Two runs of cable, one run of earth Conductor and One run of Conductor Shall be measured as One Unit length. |
| 90 | M & L for sub main wiring complete with three runs of 4 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Note:Two runs of cable, one run of earth Conductor and One run of Conductor Shall be measured as One Unit length. |
| 91 | S & F MCB SPN 40Amps, \"C\" series, 240 V complete incl making conections all as specified and directed.Make -Havellsor equivalent |
| 92 | S & F MCB SP 6-32 Amps, \"C\" series, 240 V complete incl making conections all as specified and directed.Make -Havellsor equivalent |
| 93 | Supply and fix MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed. |
| 94 | Supply and fixing wall fan ofsingle phase 230/240V of size 400 mm sweep and grouting withnut , bolts & Fastenaron the wall and make good the disturbed surface and electric connection with 1.5 Sqmmthree core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed . |
| 95 | Supply and fixing 36W LED Fitting, 2 x 2recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver with motion sensor based featurec complete all as specified including taking down old unserviceable fittings.Make : Bajaj /CG/Philips/Havells |
| 96 | Supply and fix DLP U PVC adaptable trunking of size 90 x 50mm complete with trunking accessories viz cover joints, clips, internal/external angles, partition/flat junctions and branches complete for camouflaging existing LT UG cable/ copperwiresrefixing the same after removing the existing copper/aluminium wiring from wall/roof and making proper connection to the existing panel/board complete all as specified and directed. |
| 97 | Supply and install hi wall split units air conditioner indoor/outdoorof capacity 2.0 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed.(Make :- Blue Star/Carrier/Voltas) |
| 98 | S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA |
| 99 | M & L for sub main wiring complete with two runs of 6 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. |
| 100 | S&Fdouble pole and neutral enclosure with two pin and earth plug and socket including 1NosMCB 20 Amps capacity complete all as specified and directed by Engr-in-charge |
| 101 | M&L for mild steel stand duly painted suitable for fixing 2/1.5 TR AC out door unit fixing in wall / floor, including making bore required size for copper pipe & copper cable with sweating pipe required size and length upto ground level complete all as spcecified and directed. |
| 102 | Supplying and Fixing Copper refrigerant pipe Copper tube 5/8 \" x 1/4\" dia and connecting along with insualtion sleeves incl leak testing complete all as specified and directed. |
| 103 | Supply and fixing copper power cable of insulated, PVC sheathed , multistranded copper cable of 2.5sqmm 3 core, ISI marked, 1100 volts gradebetween indoor and outdoor unit along with necessary accessories complete all as specified and directed. |
| 104 | Supplying and Fixing PVC flexible Conduit pipe 25mm dia medium grade including all accessories for drain out pipe all as directed. |
| 105 | S & F in repair MCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existingcomplete all as specified and directed. |
| 106 | S & F in repair MCB SPN 40Amps, \"C\" series, 240 V complete incl making conections all as specified and directed.Make -Havellsor equivalent |
| 107 | S & F in repairMCB SP 6-32 Amps, \"C\" series, 240 V complete incl making conections all as specified and directed.Make -Havellsor equivalent |
| 108 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 2 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Make: Havells/ Polycab/Grandlay) |