Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Repair / maintenance of street / security lights any type, flood lights or any other external lights in its position fixed on pole /building /structure/ high mast poleby taking down to ground, if required, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like electronic driver,surge protection device(SPD) connection wires/ cable, MCB etc including refixing the fittingto its original position (if taken down), including repair / maint of street light control timer & junction box complete all as specified and directed.Note:(i)The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) Cost of spareselectronic driver,surge protection device (SPD), connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately.(iii) Any type of T&P/Vehicle mounted hydraulic ladder for the work should be arranged by contractor.(iv) The contractor shall maintain proper record of repair / maint in a register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for.(v) The contractor shall maintain sufficient stock of spares / material required for repair / maint of street lights with the concerned JE E/M against the supply only items. |
| 2 | S&F in repair electronic driver suitable for any type LED light fittings complete all as specified and directed. |
| 3 | Material and labour for scrapping / removing of rust on the panel boards preparation of surfaces for fresh painting, cleaning inside the panel boards with the vacuum or blower and painting by means of spray paint with two coats of synthetic enamel paint of approved colour complete all as specified and directed. |
| 4 | M & L to find out fault in LT line bring/call fault finding machine equipment and find out fault in any size of LT UG Cable including disconnecting of cable connection from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint complete all as specified and directed.Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item. |
| 5 | M&L for rerouting of LT UG cable of any size inluding earthwork, excavation & returning & Filling and making good the disturb services good complete all as specified and directed. |
| 6 | S&F in repair ofGI pipe bracket of up to 32/40 mm dia 1.2mtr long bend to shape for street light fitting made out of32 mm dia GI light grade pipe fixed on pole using new FI clamp including necessary new nut, bolt and washer complete all as specified and directed. |
| 7 | S&F in repair surge protection device(SPD) of capacity 10KV compatible with industrial & outdooor LED fixtures complete all as specified and directed. |
| 8 | S&F in repair/replacement LED 60 Watt Street light fittings made up ofpressure die cast housing with toughened glass and direct modular IP lens, IP 66 protection, potted driver and with system efficacy of 125lm/W including making all electrical connection from light fitting topole junction box/ O/H linefor making the light functional including taking down old u/s complete all as specified and directed. |
| 9 | All as per item herein above but capacity of LED 45 Watt Street light fittings complete all as specified and directed. |
| 10 | All as per item herein above but capacity of LED 90 Watt Street light fittings complete all as specified and directed. |
| 11 | S & F in repair/replacement LED 100 watts flood light fittings white/warm white in colour, aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete, Single phase, etc fixing in MS chanel by drilling hole of suitable, size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole/any type of structure as reqd at the site including taking down old u/s complete all as specified and directed. |
| 12 | All as per item herein above but of capacity 150 Watt LED Flood light fittings complete all as specified and directed. |
| 13 | All as per item herein above but of capacity 250 Watt LED Flood light fittings complete all as specified and directed. |
| 14 | Supply and fixing of LED Focus light fixture 24 watt of white/warm white/multi coloured bobust design(IP 66) die cast aluminium housing with tempered glass for precise light distribution for illumination for piller or as required at site complete all as specified and directed.Note:- Necessary T & P/ladder required at site for fixing of light up to 18 mtr heightincluded in quoted rate. |
| 15 | Supply and Fix in replacement integral 40 Watt LED post top lantern black/ copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover and accessories complete with 50 mm OD black powder coated MS pipe not less than .3mtr length with suitable 5 mm thick ms base plate with provn of 04 Nos anchoring bolts complete all as specified and directed. |
| 16 | S&F in replacement 50 watt flood light outdoor type, IP-68, energy saving, elegantly designed cast aluminium housing and heat sink for thermal management, high efficiency long life LED module aesthetically designed diffuser and reflector to deliver uniform light output, complete all as specified and directed. |
| 17 | Supply and Fixing in replacement 10 watt LED bollard Integral decorative LED bollard with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new bollard as per site requirement and fixing arrangements complete all as specified and directed. |
| 18 | S & F in repair Digital timer switch, DIN type daily / weekly with 25ON/ OFF programmes, 16 amps 250volts AC complete all as specified and directed. |
| 19 | S & F in repair Power contactor 16/18 amps 3 pole complete all as specified and directed. |
| 20 | S & F in repair Power contactor 40 amps 3 pole complete all as specified and directed. |
| 21 | S & F in repair PVC sheathed copper cable 3 core 2.5 Sqmm grade complete all as specified and directed. |
| 22 | S& F in replacement of MCCB63 Amps 4 pole 415 V. Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links complete all as specified and directed. |
| 23 | All as per item herein above but of capacity MCCB 100 Amps 4 pole 415 V 25 KA complete all as specified and directed. |
| 24 | Supply & Laying, jointing & testing of UG LT cables 35 sqmm 4 core XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size complete all as specified and directed. |
| 25 | All as per item herein above but size 25 sqmm 4 core complete all as specified and directed. |
| 26 | All as per item herein above but size16 sqmm 4 core complete all as specified and directed. |
| 27 | All as per item herein above but size10 sqmm 4 core complete all as specified and directed. |
| 28 | Taking out existing defective worn out UG LT cable of any size 1100 volts grade from trenches of any size from different locations complete all as specified and directed. Note:Excavation & earth wk shall be measured and paid for separately. |
| 29 | Excavation in trenches in hard/ dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed. |
| 30 | Excavation in trenches in soft/loose soil n exc 1.5mwide and n.exc 1.5m in depth and getting out complete all as specified and directed. |
| 31 | Returning, filiing in incl spreading, leveling watering and well ramming excavated soil inlayers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested complete all as specified and directed. |
| 32 | Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 33 | Supply & Laying in repair double wall corrugated pipe 50 mm bore(DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement complete all as specified and directed. |
| 34 | All as per item herein above but size 40 mm bore complete all as specified and directed. |
| 35 | S&F in repair GI tubing 80 mm bore light grade ISI marked with all fittings laid in trenches for protection of LT cables or onfixed pole by flat ironclamps, nut, bolt, washers suitable size complete all as specified and directed. |
| 36 | All as per item herein above but size 50 mm bore complete all as specified and directed. |
| 37 | All as per item herein above but size40 mm bore complete all as specified and directed. |
| 38 | Supply and fix in replacement of cable Junction box thermo plast (weather proof) IP 66,on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size withconnector for connecting incomming and outgoing of cableincluding 01 No of MCB DP 10 Amps to control the pole light circuit andMS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable complete all as specified and directed. |
| 39 | All as per item herein above but of of size 140mm x 140 mm x 95 mm complete all as specified and directed. |
| 40 | Cutting bituminus road/hard standingby using suitable hydraulic road cutter for a width not exceeding 300 mm and depth 600 mm forlaying of GI pipe incl refilling and making good with Tarmac/ PCC/RCC duly matching with the existing surface complete all as specified and directed.Note:1. Gi pipe will be measured & paid separately.2. Quoted rate shall deemed to incl the cost of making good the disturbed surface. |
| 41 | M&L for straight through joint (epoxy) for PVC insulated and sheathed aluminium conductor under ground cableincl freud, thimbles, nut & bolts, washers etc and testing afterjointing complete all as specified and directed.(a) 10 sqmm to 35 sqmm 3.5 core |
| 42 | Supply & fix in repair GI tubing light grade 40 mm dia ISI marked 1 mtr long with Flat Iron Base for mounting of Flood lightwith all fittings incl nut, bolt, washers suitable size complete all as specified and directed. |
| 43 | M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT (up to 11 Mtr) height above ground level , preparing surface for painting, applying two coats of aluminium paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site including making balck and white strips of 30 cms each upto 1.5 m above PCC muffs with black and white paint and marking of pole no up to 2 m above PCC muff, letter should not be longer than 6 cm height with 16 cm dia circle around the marked no complete all as such complete all as specified and directed. |
| 44 | Supply, transport, errecting and fixing in repairs steel tubular swaged welded pole of over all height 8.5 m long complete type 410-SP-22 conforming to IS-2713 (Part I to III 1998 with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed.Note: Unit rate shall deemed to be quoted for following :-(i)Excavation, earth work and PCC work for embedding pole. (ii) Pole upto 1.5 m top of coping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer.(iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer (iv)Pole below ground shall be tarred by one coat(v) Poles shall be numbered. |
| 45 | S&F in repairs automatical timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB power contactor and 230V digital time switch for controlling LED/SV etc street lights ,including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35 mm x 35 mm x 4 mm thick angle iron supports of not less than each 0.6 m height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement complete all as specified and directed. |
| 46 | Disconnecting/taking down the hexagonal/Hectagonal GI Pole which is titling/leaning by engaging suitable crane or manullay and refixing the same with suitable nut and bolt on existing foundation complete all as specified and directed. |
| 47 | S&F for PVC insulated flat twin core 2.5 Sqmm solid aluminium conductor cable including PVC conduit pipes of dia not less than 20 mm for connection of security lightfrom junction box or existing source to light fitting to be drawn through conduit/pipe along the pole or through inside the street light pole or over head line/existing source to street light fittings etc, including taking out old u/s wirescomplete all as specified and directed. |
| 48 | S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of3.15 mm thick CRCAsheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finishwith seven tank pre treatment process.The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof.All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable.The panel shall be provided with aluminium bus bars, 300mm X 40mm X 5mm (thickness) electrolytic grade of adequate rating.The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with 4. RYB & black colour coding and fix horizontally.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles all joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers.The panel shall be provided with 04 Nos 25mmx25mmx3mm thick angle iron supports of not less than each .3 mtr height duly painted with anti corrosive black paint and grouted on wall (at Sudan Dome)and suitable fixing arranement as per site requirement.The overall size of the Busbar panel shallbe 350mmx200mmx400mm (LxBxH) including PCC 1:3:6 complete all as specified and directed. |
| 49 | Disconnecting and taking out old existing worn out cablelugs, nuts, bolts, washers etc fromLT panel board of 4 wire system (incomming and outgoing) and supply and connect withnew aluminium lugs all sizes as per site requirement and nuts, bolts, washers etc complete all as specified and directed. |
| 50 | Repair and refixing of u/s voltmeter/Ammeter of different capacity ccomplete all as specified and directed. |
| 51 | S&F in replacament of LED type phase indicator to be fitted on panel (R,Y, B as per site requirement) complete all as specified and directed. |
| 52 | M & L for replacement of unserviceable MS clamp with new clamp as per sample/as per site requirement made out of MS flat iron 25 x 5mm including fixing nuts bolts, washers etc and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 53 | Supply and fix in repair of aluminium lugs of size 6 sqmm to 16 sqmm complete all as specified and directed. |
| 54 | Supply and fix in repair of aluminium lugs of size 25 sqmm to 50 sqmmcomplete all as specified and directed. |
| 55 | Supply and fix in repair of aluminium lugs of size 70 sqmm to 120 sqmm complete all as specified and directed. |
| 56 | Taking down carefully aluminium / copper point wiring any type for one light, fan, socket power point or buzzer controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket etc; and making good disturbed surfaces of walls, ceilings etc complete all as specified and directed. |
| 57 | M & L for point wiring with 1.5 sqmmFRLSH, PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade (MMS ISI) of size not less than 20 mm dia or as site requirement, concealed in wall/over ceiling, concealed terminal / metal boxes of required size and with top cover 3 mm thick of plastic laminated hylam sheet or modular box and cover plate with frame or PVC box (as per site requirement) complete for mounting of switch, switch socketregulator etc with all accessories and all as specified including 1.5 sqmm FRLSH PVC insulated sheathed multistranded copper earth conductor to common earth and connected to earth dollyfor light / fan/ bell point controlled by one switch.Note:- (i) Cost of PVC conduit, metal boxes, plastic laminatedhylam sheet cover or modular box and cover plate with frameetc; are deemed to be included in the quoted rate.(ii) M&L for cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate. |
| 58 | All as per item herein above but for 3 pin or 3/5 pin 5 Amps socket, switchsocket combination on independent board with 1.5 sq mm copper cable complete all as specified and directed. |
| 59 | All as per itemherein above but for 3 pin or 3/5 pin 16 Amps socket , switch socket combination on independent board with 2.5 sq mm copper cable complete all as specified and directed. |
| 60 | All as per itemherein above but for 3 pin or 3/5 pin 16 Amps socket, switch socket combination on independent board with 4.0 sq mm copper cable complete all as specified and directed. |
| 61 | All as per item herein above but for 3 pin or 3/5 pin 5 Amps socket point on the same board controlled by one switch complete all as specified and directed. |
| 62 | All as per item herein above but for one light point controlled by two, two way switch with 1.5 sq mm copper conductor cable complete all as specified and directed. |
| 63 | M & L for point wiringwith 1.5 Sqmm multi stranded copper conductor 1100 V grade, ISI marked, PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 20/25/32 mm wide, with double locking type, includingmetal boxes of required size and with top cover 3 mm thick of plastic laminated hylam sheet or modular box and cover plate with frame or PVC box(as per site requirement) complete for mounting of switch, switch socket, regulator etc with all accessories, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, PVC terminal box and PVC board making good disturbed surface to match with the existing surface for one light /fan/bell point controlled by one switch complete all as specified and directed.Note:- (i) Cost of PVC casing caping, metal boxes, plastic laminatedhylam sheet cover or modular box and cover plate with frameetc; are deemed to be included in the quoted rate.(ii) M&L for cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate. |
| 64 | All as per item herein above but for 3 pin or 3/5 pin 5 Amps socket point on the same board controlled by one switch complete all as specified and directed. |
| 65 | All as per item herein above but for 3 pin or 3/5 pin 5 Amps socket , switchsocket combination on independent board with 1.5 sq mm copper cable complete all as specified and directed. |
| 66 | All as per item herein above but with 2.5 sqmm single core multistranded copper conductor FRLSH cable for 3/5 pin 15 Amp socket outlet on independent board complete all as specified and directed. |
| 67 | All as per item herein above but with 4.0 sqmm single core multistranded copper conductor FRLSH cable for 3/5 pin 15 Amp socket outlet on independent board complete all as specified and directed. |
| 68 | All as per item herein above but with 2.5 sqmm single core multistranded copper conductor cable for4x1 number 3/5 pin 5/6 Amp socket outlet on independent board complete all as specified and directed. Note : switch socket will be measure and paid seperately. |
| 69 | All as per item herein above but with 2.5 sqmm single core multistranded copper conductor cable for2x1number 3/5 pin 5/6 Amp socket outlet on independent board complete all as specified and directed.Note switch socket will be measure and paid seperately. |
| 70 | All as per item herein above but for one light point controlled by two, two way switch with 1.5 sq mm copper conductor cable complete all as specified and directed. |
| 71 | Supply only in replacement of switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed. |
| 72 | Supply in replacement of switch socket combination 2 in one, 5 pin , 5/6 Amps, 240 Volts flush type complete all as specified and directed. |
| 73 | Supply in replacement of switch socket combination 2 in One , 5/6 pin, 5/6/16 Amps flush type complete all as specified and directed. |
| 74 | Supply in replacement of switch flush type, 5 Amps, SP, two way complete all as specified and directed. |
| 75 | Supply in replacement of switch bell push flush type 5 Amps complete all as specified and directed. |
| 76 | Supply in replacement of call bell, Ding dong type, AC 230 Volts single pole complete all as specified and directed. |
| 77 | Supply in replacement ofceiling rose polycarbonate typethree terminals complete all as specified and directed. |
| 78 | Supply in replacement of step type electronic fan regulator 120 wattsingle pole 240 Volts complete all as specified |
| 79 | Supply in replacement of Modular switch 1 way 6/10 A 1 module module complete all as directed. |
| 80 | Supply in replacement of Modular switch 1 way 16 Amp SP ,1 module complete all as directed. |
| 81 | Supply in replacement of Modular Fan step regulator, 120W - 2 module complete all as directed. |
| 82 | Supply in replacement of Modularbell push6 A 2 module complete all as directed. |
| 83 | Supply in replacement of Modular Socket 6 A 2/3 pin combined 2 module complete all as directed. |
| 84 | Supply in replacement of Modular Socket 6 A /16 A-2/3 pincombined 2 module complete all as directed. |
| 85 | Supply in replacementof metal flushbox 12 module complete all as directed. |
| 86 | Supply in replacementof metal flushbox 8 module complete all as directed. |
| 87 | Supply in replacementof metal flushbox 6 module complete all as directed. |
| 88 | Supply in replacementof metal flushbox 3 module complete all as directed. |
| 89 | Supply in replacementof white cover plate with frame 12 module complete all as directed. |
| 90 | Supply in replacementof white cover plate with frame 8 module complete all as directed. |
| 91 | Supply in replacementof white cover plate with frame 6 module complete all as directed. |
| 92 | Supply in replacementof white cover plate with frame 3 module complete all as directed. |
| 93 | Supply in replacement of Lamp holder PVC/ Polycarbonate type with cord grip cap suitable for pendent fitting complete all as specified and directed |
| 94 | Supply in replacement of LED bulb of 10W with Lumen output 950 lm and Colour Temp 6500K B22 type fitted suitable for PVC / Polycarbonate type complete all as specfied and directed. |
| 95 | Supply in replacement of LED Tube light luminaires, 20 - 22 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable offrom connector and ceiling rose, complete all as specified and directed. |
| 96 | Supply in replacement of LED tube rod 18/ 20 watt with high efficacy, lumen output not lessthan 100 lm/W (4 feet), made of crystal glass, high lumen output, and operated in single phase, 230 volts, 50HZ, suited for installation in existing tubelight luminaire complete all as specified and directed. |
| 97 | Supply in replacement of mirror light batten type 11 W 230V AC, 50Hz, Pf >0.98, THD <10% on wall complete all as specified and directed. |
| 98 | Supply in replacement of LED bulk head outdoor wall light fixture 18 Watt , pressure Al housing, IP 54 protection and IK 09 impact resistance suitable for surface and wall mounting complete all as specified and directed. |
| 99 | Supply in replacementof LED concealed COB/spot light fixture 12 Watt , tiltable with decorative finish of warm white coloured complete all as specified and directed. |
| 100 | Supply in replacementof outdoor surface LED COB/surface light (IP 54) light fixture 12 Watt , with decorative finish of white/ warm white coloured complete all as specified and directed. |
| 101 | Supply in replacementof LED COB/surface downlights metal body (outdoor type IP54) fixture 12 Watt, with decorative finish of white/ warm white coloured complete all as specified and directed. |
| 102 | Supply in replacement decorative indoor wall light fixture metalic body single head wall light suitable for 20 watt maximun wattagecomplete all as specified and as directed. |
| 103 | Supply in replacement of 36 watt LED recess/surface mounted 2\"x2\" size flat panel fabricated CRCA sheet housing,duly powder coated with high efficient LED glare free full opal diffuser, IP20 andwith system efficacy of 120lm/W which provide soft light and glare free symmertical illumination suitable for armstrong/grid ceiling of 2\"x2\" size(Lumen output not lessthan 3600) complete all as specified and directed. |
| 104 | Supply in replacement of 45 watt LED recess/surface mounted 2\"x2\" size flat panel fabricated CRCA sheet housing,duly powder coated with high efficient LED glare free full opal diffuser, IP20 andwith system efficacy of 120lm/W which provide soft light and glare free symmertical illumination suitable for armstrong/grid ceiling of 2\"x2\" size (Lumen output not lessthan 3600) complete all as specified and directed. |
| 105 | Taking down old recess mounting 2\" x 2\",LED light luminaire 36-45W and refixing same after repair or by replacing required item of reccess light complete all as specified and as directed. (Note: LED driver and surge protection device will be measured and paid separately) |
| 106 | Supply and Fixing in replacement of LED Driver 33-45W with surge protection device of recess mounting 2\" x 2\",LED light luminaire, IP65, complete all as specified and as directed. |
| 107 | Supply and fixingin repair electronic LED driver for wall security light of 30/45 Watt LED complete all as specified and as directed. |
| 108 | Supply in replacement of new generation energy saving and environmental friendly long life 30 W LED building security light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top Opening seperate driver compartment with IP66 protection and impact resistance of IK07including necessary brackets (made out of suitable bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls with MS clamp complete all as specified and directed. |
| 109 | Supply in replacement of new generation energy saving and environmental friendly long life 45 W LED building securitylight made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top Opening seperate driver compartment with IP66 protection and impact resistance of IK07including necessary brackets (made out of suitable bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls with MS clamp complete all as specified and directed. |
| 110 | Taking down ceiling fan any type/ size from hook and dismantling cable and blades and bring in to contractor store for repair and hanging ceiling fan in position after repair, greasing etc. with existing flexible copper cable complete all as specified and directed. (Rewinding of fan, painting and spare parts required shall be measured and paid separately) |
| 111 | Taking down exhaust fan any type/ size from wall and dismantling sealing cable and dismantling blades and bring in to contractor store for repair and fixing exhaust fan in position after repair, greasing etc. with existing flexible copper cable complete all as specified and directed. (Rewinding of fan, painting and spare parts required shall be measured and paid separately) |
| 112 | M&L for rewinding of ceilingfan 1200/1400 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed. |
| 113 | M&L for rewinding of exhaustfan 280 to 450 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed. |
| 114 | Supply in replacement of brass bush for ceiling fan / exhaust fan as existing size complete all as specified and directed. |
| 115 | Supply in replacement of bearing suitable for ceiling fan 1200 mm to 1400 mm /exhaust fan of bearing No- 6201/6202 complete all as specified and directed. |
| 116 | Supply in replacement of capacitor 2.5 MFD for ceiling fan. complete all as specified and directed. |
| 117 | Supply in replacement of capacitor 4.0 MFD for exhaust fan complete all as specified and directed. |
| 118 | Supply in replacement of rubber real with bolts, nuts and clamps of suitable for ceiling fan complete all as specified and directed. |
| 119 | Supply in replacement of PVC insulated flexible copper cable 3 core of size 23/0.0076 complete all as specified and directed. |
| 120 | Taking down carefully water heater storage type of any capacity from its position for repair/ overhauling by disconnecting complete electric/water supply connections, taking out geyser assembly repairing by minor welding of inner tank re-assembling the geyser and refixing the same by connecting electric / water supply connections and testing complete all as specified and directed. Note: Spares will be measured and paid separately. |
| 121 | Supply in replacement ofheating element of capacity 2/3 KW thermostat with auto cut-off feature of anytype (as per sample) complete all as specified and directed. |
| 122 | Supply in replacementthermostate adjustable between 30 degree to90 degree celcius of any size /type as per existing (ISI marked) complete all as specified and directed. |
| 123 | Supply in replacementindicator lamp of suitable capacity including its electrical connection complete all as specified and directed. |
| 124 | Supply in replacement of PVC connection heavy duty 450mm long with 2 nuts brass at both ends suitable for hot water for GI pipe 15 mm dia complete all as specified and directed. |
| 125 | Supply in replacement of MS anchor fastener heavy duty 12mm dia 10 cm long complete all as specified and directed. |
| 126 | Supply in replacement of plug top, AC 230 Volts, 6 Amps complete all as specified and directed. |
| 127 | Supply in replacement oft plug top, AC 230 Volts, 16 Amps complete all as specified and directed. |
| 128 | Supply in replacement of hylam sheet cover 3 mm thick for fixing switches,sockets, regulators etcof suitable size on existing metal box complete all as specified and directed. |
| 129 | Supply in replacement of PVC casing & capping medium grade with fittings, ISI marked, 20 mm size complete all as specified and directed. |
| 130 | Supply in replacement of PVC casing & capping medium grade with fittings, ISI marked, 25 mm size complete all as specified and directed. |
| 131 | Supply in replacement of PVC insulated copper conductor cable, FRLSH, single core, 1100 Volts,1.5 Sq mm with colour coding complete all as specified and directed. |
| 132 | Supply in replacement of PVCinsulated copper conductor Cable, FRLSH, single core, 1100 Volts,2.5 Sq mm with colour coding complete all as specified and directed. |
| 133 | Supply in replacement of PVCinsulated copper conductor Cable, FRLSH, single core, 1100 Volts,4.0 Sq mm with colour coding complete all as specified and directed. |
| 134 | Supply in replacement of PVCinsulated copper conductor Cable, FRLSH, single core, 1100 Volts,6.0 Sq mm with colour coding complete all as specified and directed. |
| 135 | Taking down burnt/unserviceable sub main wiring any size complete and making good disturbed surfaces of walls complete all as specified and directed. |
| 136 | Supply and draw submain wiring with two single core 2.5 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduit including 2.5 sq mm multi-strand FRLSHPVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete.Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted. |
| 137 | All as per item hereinabove but on surface PVC casing caping medium grade of 20-25 mm wide, with double locking type, including all accessories completeall as specified and directed. |
| 138 | Supply and draw submain wiring with two single core 4.0 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduit including 4.0 sq mm multi-strand FRLSHPVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete all as specified and directed.Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted. |
| 139 | All as per item herin above but on surface PVC casing caping medium grade of 20-25 mm wide, with double locking type, includingall accessories completeall as specified and directed. |
| 140 | Supply and draw submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduit including 6 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete all as specified and directed.Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted. |
| 141 | All as per item hereinabove but on surface PVC casing caping medium grade of 20-25 mm wide, with double locking type, including all accessories complete all as specified and directed. |
| 142 | Taking down main switches and DBs of any type and make including wooden board/ junction box and making good disturbed surfaces of wall, floor etc complete all as specified and directed. |
| 143 | S & Fsingle pole and neutral enclouser with atwo pin and earth plug and socket complete with one pole MCB 20 Amps complete all as specified and directed. |
| 144 | S & F sheet metal enclosuredouble door for MCB DBs SPN 4 way 240 V completedouble door, flush mounted complete all as specified and directed. |
| 145 | S & F sheet metal enclosure double doorfor MCB DBs SPN 8 way 240 V, complete flush mounted complete all as specified and directed. |
| 146 | S & F sheet metal enclosure double doorfor MCB DBs SPN 12 way 240 V, complete flush mounted complete all as specified and directed. |
| 147 | S & F sheet metal enclosure double doorfor MCB DBs TPN 8 way 415 V, complete flush mounted complete all as specified and directed. |
| 148 | S & F sheet metal enclosure double doorfor MCB DBs TPN 12 way 240 V, complete flush mounted complete all as specified and directed. |
| 149 | M&L for sheet metal enclosure for Ekinox TPN DB-VTPN 4 way 415 V, double door, 250 A copper bus bar, IP 43, including 160 Amp MCCB as incomer as flush mounted complete all as specified and as directed. |
| 150 | S & F in repair MCB single pole (SP) 6 to 32 Amps,240 volts , C curve , AC , 50 Hz ,10 kA complete all as specified and directed. |
| 151 | S & F in repair MCB Single pole & neutral (SPN)32 Amps, 240 volts , C Curve, AC , 10 kA complete all as specified and directed. |
| 152 | S & F in repair MCB Single pole & neutral (SPN)40-63 Amps, 240 volts , C Curve, AC , 10 kA complete all as specified and directed. |
| 153 | S & F in repair MCB Tripal pole & neutral (TPN)32 Amps, 415 volts , C Curve, AC , 10 kA complete all as specified and directed. |
| 154 | S & F in repair MCB Tripal pole & neutral (TPN)40-100 Amps, 415 volts , C Curve, AC , 10 kA complete all as specified and directed. |
| 155 | Supply in replacement PVC Insulated 4 Core Copper Cable 4 Sq mm Wire1100 volts grade complete all as specified and directed. |
| 156 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Metre below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI and GI tubing 15 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as shown on electrical plate No. 3 of SSR part - I, including taking out old U/s complete alll as specified and directed. |
| 157 | Taking down window/split type AC capacity 1.5 ton for throughout checking and servicing of indoor/out door unit, replacing the defective parts of its smooth functioning or taking out compressor unit from the unit duly cutting the copper tubings and taking out the same for replacement all as specified and directed and refixing the same after servicing and replacement of defective/wornout part complete all as specified and directed.Notes :- 1.Spare partswill be measured andpaid separately under respective items of Sch , 2. T & P required for lifting /lowering at site is contractor responsibility. |
| 158 | All as per srl item herein above but 2.0 Ton complete all as specified and directed. |
| 159 | Supply and fixing in replacement of AC compressor suitable for 1.5 ton capacity air conditioning(type of compressor as per existing) with all accessories duly connecting and soldering/ brazing of copper tubings etc and leak testing and charging of gas etc. complete including testing complete all as specified and directed. |
| 160 | All as per srl item herein above but 2.0 Ton complete all as specified and directed. |
| 161 | Supply and filling of refrigerant gas (as per existing) for air conditioner 1.5 & 2.0TR complete all as specified and directed. |
| 162 | S&F in replacement PCB (as per existing model/make) suitable for 1.5/ 2.0 Ton split or window type AC complete all as specified and directed. |
| 163 | S&F in replacement, selector switch complete suitable for window type AC 1.5 ton complete all as specified and directed. |
| 164 | Taking down the defective/ burntblower motor from the window/ split type AC duly disconnecting wires and blower and fan blade taking to civil work shop/contractor store and repair, rewinding with super enamelled copper winding wire of suitable size and gauge after cutting and taking out burnt winding wire and re-fixed after repair and re-conected electrical connection and blades & blower in window/ split AC includingtesting complete all as specified and directed. |
| 165 | Supply and fixing in replacement of copper tubing along with necessary insulation suitable for existing bore and size 1/4 inch (6.35mm) including union connector, brass C cap, copper coupling etc complete all as specified and directed. |
| 166 | Supply and fixing in replacement of copper tubing along with necessary insulation suitable for existing bore and size 15.88mm (5/8 inch)/1/2 inch (12.7mm) including union connector, brass C cap, copper coupling etc complete all as specified and directed. |
| 167 | S & F in replacement of AC copper condenser coil suitable for split type AC 1.5 TR as per sample complete all as specified and directed. |
| 168 | S & F in replacement of AC copper condenser coil suitable for split type AC 2.0 TR as per sample complete all as specified and directed. |
| 169 | S&F in replacement remote suitable for 1.5/2.0 Ton AC as per sample complete all as specified and directed. |
| 170 | S&F in replacement running capacitor of capacity 36 MFD complete all as specified and directed. |
| 171 | S&F in replacement dual capacitor of capacity 45/36 MFD complete all as specified and directed. |
| 172 | S&F in replacement AC Capacitor of capacity6 MFD complete all as specified and directed. |
| 173 | S&F in replacement AC Capacitor of capacity4 MFd complete all as specified and directed. |
| 174 | S&F in replacement thermostat for window type AC /Split type AC of capacity1.5 TR/ 2.0TR as per sample complete all as specified and directed. |
| 175 | S&F in replacement of fan blade forAC of capacity 1.5 TR/ 2.0TR as per sample complete all as specified and directed. |
| 176 | S & F in replacement of front grill suitable for AC 1.5/2 TR (Split or window) as per sample complete all as specified and directed. |
| 177 | S & F in replacement of AC blower suitable for window AC 1.5/2 TR as per sample complete all as specified and directed. |
| 178 | S & F in replacement of indoor unit AC blower suitable for Split type AC 1.5 TR/2 TR as per sample complete all as specified and directed. |
| 179 | S&F air filter of suitable size for window ACs of any capacity complete all as directed by Engineer -In- Charge. |
| 180 | S&F air filter of suitable size for split ACs of any capacity complete all as specified and directed. |
| 181 | S & F in replacement of temperature sensor suitable for Window/Split type AC 1.5 TR/2 TR as per sample complete all as specified and directed. |
| 182 | S & F in replacement of out door bracket including all fitting as nut , bolt , fasteners for Split type AC 1.5 TR/2 TR as per sample complete all as specified and directed. |
| 183 | S&F in replacement indoor unit suitable for 1.5 TR capacity split AC complete all as specified and directed. |
| 184 | S&F in replacement of out door unit suitable for 1.5TR capacity split air conditioner complete all as specified and directed. |
| 185 | S&F in replacement indoor unit suitable for 2 TR capacity split AC complete all as specified and directed. |
| 186 | S&F in replacement of out door unit suitable for 2 TR capacity split air conditioner complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail