| 1 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded/solid of size 10 Sqmmincluding taking down old unsv service cablecomplete all as specified |
| 2 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 4 Sqmm including taking down old unsv service cable complete all as specified |
| 3 | Supply and fix in repair PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 3 core 1.5 sqmm 1100 Volt, conforming to IS 694, multistranded with Rigid Heavy duty PVC Conduit of 20 mm dia with bends from Junction box to connector of Street light fitting complete all as specified and as directed. Make Polycab/ Finolex/ Havells/ Gloster/ Nicco |
| 4 | Supply and fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core including necessary arrangement for fixing on wall, roof, Pole etc by using clamps, screws, porceilane insulators etc including taking down old unsv service cablecomplete all as specified and directed |
| 5 | Supply & fixing of cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core including necessary arrangement for fixing on wall, roof, pole etc by using clamps, screws, porceilane insulators etc including taking down old unsv service cablecomplete all as specified and directed |
| 6 | Supply & fixing of cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core including necessary arrangement for fixing on wall, roof, pole etc by using clamps, screws, porceilane insulators etc including taking down old unsv service cablecomplete all as specified and directed |
| 7 | Supply & fixing of cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core including necessary arrangement for fixing on wall, roof, pole etc by using clamps, screws, porceilane insulators etc including taking down old unsv service cablecomplete all as specified and directed |
| 8 | Supply & fixing of cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sq. mm 3.5 core including necessary arrangement for fixing on wall, roof, pole etc by using clamps, screws, porceilane insulators etc including taking down old unsv service cablecomplete all as specified and directed |
| 9 | M & L for cable jointing kit out door type for 1.1 KV cable for Stright through heat shrink type complete with jointing materials and accessories suitable for 3.5/4.0 core XLPE armoured aluminium conductor cable of following size including find the fault excavation/returning & refilling of loop excavation complete all as specified and directed |
| 10 | 95 to 70 Sqmm 3.5 core |
| 11 | 50 to 25 Sqmm 3.5 core |
| 12 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded/solid of size 6 Sqmmincluding taking down old unsv service cablecomplete all as specified |
| 13 | Excavation in trenches,in soft/loose soilnot exceeding 1.5 m deep and not exceeding 1.5 m in wide for laying of cable,RCC Poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and as directed. |
| 14 | Returning, filling-in, including spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified. |
| 15 | M & L for sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note :- Punned down thickness shall be measured for payment |
| 16 | M&L for laying common burnt bricks, sub class \"B\", of size 230 x 115 x 75 mm in trenches for cable protection complete all as specified and as directed. |
| 17 | M&L Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting complete all as specified and directed |
| 18 | S&F in replacement Street light timer analog clock type 3 module with battery backup, programable for every 15 Min, and connected to existing power contact for controlling complete all as specified and as directed. |
| 19 | S&F in replacement of Power Contactor of 3 Phase, 40 Amps, 4 Pole, in existing Street light panel and connection with bus bar / cable with copper wire complete all as specified and as directed |
| 20 | Material & Labour for MCB TPN in repair/replacement of 63 Amp 415 V unserviceable existing MCB including taking down by removing burn out cable and fixing of new MCB and provn of connection by using suitable PVC copper cable not less than 1.5 Sqmm as existing complete all as specified and directed |
| 21 | Material & Labour for fixing of MCCB 415 V, 16 KA, 3 Pole 63 A including taking down old burn out MCCB and making necessary arrangement for fixing the new one like cutting, welding, thimble of suitable size, nuts & bolts etc complete required for fixing the new one all as specified and directed |
| 22 | Material & Labour for fixing of MCCB 415 V, 16 KA, 3 Pole 125 A including taking down old burn out MCCB and making necessary arrangement for fixing the new one like cutting, welding, thimble of suitable size, nuts & bolts etc complete required for fixing the new one all as specified and directed |
| 23 | Dismantiling / taking down LED street light / security lights of any capacity & description from exising LT pole/octaganol street light pole of height 7.5 mtr and 9 mtr pole refixing the fittings in existing / another location after repair work or carrying to credit complete all as specified and as directed. |
| 24 | Supply & fix in repair LED Driver of 45 Watt of suitable make and model as per exisiting LED 45 Watt Street light fitting.Make: Havells/ Crompton / Bajaj |
| 25 | Supply & fix in repair LED Driver of 25 Watt of suitable make and model as per exisiting LED 25 Watt Street light fitting.Make: Havells/ Crompton / Bajaj |
| 26 | Supply and fixing in repair LED street light fitting with and including individual high power 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast alu with secondary optics, suitable for outdoor use IP 66, connected withconnecting cable complete all as specified and as directed |
| 27 | Supply and fixing in repair LED street light fitting with and including individual high power 25 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast alu with secondary optics, suitable for outdoor use IP 66, connected withconnecting cable complete all as specified and as directed |
| 28 | S&F in replacement of Flood light of any wattage and type with LED Flood light of 150 Watt Symetrical illumination, along with Driver assembly as per OEM Specifications, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light and connecting up existing cable complete all as specified and as directed. Make: Havells, Model: JETAIRISFLS150WLED757PSYMLTG or its equivalent in Philips/ Wipro/ Crompton |
| 29 | S&F in replacement of existing loop in-out junction box with non metalic PVC junction box suitable of size not less than 350 x 250 x 150 with connector 4 way and including one MCB SP 6 A, 230V alongwith 2 Nos \"C\" Clamps and back clamp made up of 20x3 flat iron/Aluminium and fixing on pole with necessary nuts bolts, washers, 2 Nos PVC cable glands of size not exc 4 core 25 sqmm, Cable lugs as required complete all as specified and as directed. |
| 30 | S&F in replacement of 3 phase heavy duty Capacitor bank of capacity 3 KVAR includingincluding taking down old unsv capacitor bank , Suitable size copper Cable as required complete all as specified and as directed. |
| 31 | All as above item No 30 but 5 KVAR Capacitor bank |
| 32 | All as above item No 30 but 7.5 KVAR Capacitor bank |
| 33 | All as above item No 30 but 10 KVAR Capacitor bank |
| 34 | All as above item No 30 but 15 KVAR Capacitor bank |
| 35 | All as above item No 30 but 10 KVAR Capacitor bank |