| 1 | Surface dressing n.exc. 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Surface excavation n.exc 30 cm deep and averaging 15cm deep in soft/loose soil and getting out complete all as specified and as directed. |
| 3 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 4 | Excavation in trenches not exceeding 1.5 m wide for foundationor for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sqm on plan and exceeding 1.50 in depth but not exc 3.0 m and getting out soft/loose soil complete all as specified and directed |
| 5 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 6 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 7 | M&L for Sand filling under floors,foundations or in trenches for cushioning of underground cable including watering and consolidation complete all as specified and as directed. Note: Punned thickness of sand cushioning will be measured and paid. |
| 8 | M&L for hard core with broken bricks of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 9 | M&L for hard core with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 10 | M&L for PCC 1:4:8Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 11 | M&L for PCC 1:3:6Type C-2 ( Using 40mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 12 | M&L for 100 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in sub base of floor over and including 50 micron polythene film laid complete all as specified and directed. |
| 13 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and as directed. |
| 14 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in drain walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed. |
| 15 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 16 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batterfair finished flat surfaces of concrete complete all as specified and as directed. |
| 17 | Use and waste formwork to faces of wall, retaining walls, parapets, railing and similar work including attached pilasters, buttresses etc vertical or to batter for fair finished surfaces of concrete flat or curved complete all as specified and as directed. |
| 18 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja,floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 19 | M & L for mild steelTMT bars 10 mm dia and overcut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 20 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 21 | M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 22 | Supply only Nanotechnology based Elastomeric Hydrophobic Powder/admixture (EHP) powder for cement plaster and concrete complete all as specified and directed. |
| 23 | M&L for Joint free Coloured Non-skid ceramic tiles (Exterior grade paving tiles) 8 to 10mm thick (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor/ etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 24 | M&L for MS steel Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. and similar work conforming to Fe. 290.Gde-E-165 complete all as specified and as directed. |
| 25 | M & L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250) for fixing complete all as specified and as directed. |
| 26 | S&F SS-304 grade Stainless Steel outdoor Bench with Back rest, made out of SS square pipe, moulded and welded as per required size and design, 3-Seater capacity, not less than 5ft in length and weather proof complete, each weigh not less than 45 kgs complete all as specified and as directed. |
| 27 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 28 | S&F 4mm thick ACP (Aluminium composite panel), regular, exterior application grade, etc. of any shade/colour as approved, fixed with powder coated screws to iron framework and hiding joints with chamfered cut or sealant tape, etc and including CNC cut texture (as approved) on ACP sheet panel complete all as specified and as directed.Note : 1. Make shall be Alstone or equivalent.2. Colour and Texture shall be as approved. |
| 29 | S&F UV resistant Embossed Polycarbonate Sheet, 6mm thick, 1.20 gm/cm³ density, tensile strength 55 Mpa, fixed to iron framework with SS screws complete including silicon adhesive jointing at lap/joints complete all as specified and as directed. |
| 30 | Rolling and consolidating formation surfaces in cutting using hand roller 0.2 to 0.5 complete all as specified and as directed. |
| 31 | Supply and laying HDPE Perforated & textured for superior interlock black geocell cellular grid nexc 75mm thickness over made-up ground complete all as specified and as directed. |
| 32 | Supply only and laying broken brick aggregate (20mm and less) over HDPE geocell grid upto required thickness complete all as specified and as directed. |
| 33 | M&L for Construction ofSoakage wells including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 M dia X 3.00M effective depth all as specified and shown on drawing No. CE/TD/464(R) sheet 1/1.Note:- Drawing is only for reference purpose. |
| 34 | S&F stainless steel strainer including grease trap is a removable basket that trap solid waste and prevent clogs in the grease removal system of capacity not less than 16 Litre as per site requirement tested complete all as specified and as directed. |
| 35 | M & L for 150mm bore reinforced concrete pipes, class NP2, laid and jointed with collars complete all as specified and as directed.Note : Earth work shall be measured and paid separately under respective item. |
| 36 | M & L for pcc 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bed for RCC pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 37 | supply and laying factory made kerb stone M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.Note : Rate shall be inclusive of necessary excavation and embedding kerb stone in places duly packing sides as required andtesting of random samples of Precast cement concrete (M-25) kerb stones. |
| 38 | M&L for lacquer coated,polished chequered cement concrete tiles in floor, area exc 0.06 Sqm but not exc 0.11 Sqm, 30 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 15 mm thick cement mortar (1:6)complete all as specified and as directed. |
| 39 | Dismantling of old unserviceable/ ACSR conductors of any size from overhead lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and as directed. |
| 40 | supply, erection and commissioning ofsteel tubular swaged poles simple/decorative type complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type LT type 410 SP-31, (9m long)including two coat of synthetic emulsion paint upto 1.2 m hight in black and yellow strips (as directed at site during painting) colour and there on synthetic enamel paint silver colour on steel surface such as complete pole, cross arms, brackets, MS flats, nuts, bolts and all accessories fixed on polewithexcavation, earth work, PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundation and coping of poles with PCC 1:2:4 type B1 (using 20mm graded stone aggregate) including dismantling of old pole complete all as specified and as directed.Note :- Excavation, earth work and concrete work complete not included in unit item and the same will be measured and paid under respective items. |
| 41 | M & L for PCC 1:2:4, type B1 (using 20 mm gradedcrushed stone aggregate) as in benching and coping, pole coping,cills, hold fasts, fixing of post, water rough etc. includingnecessary formwork (straight or curved) complete all as specified and as directed. |
| 42 | S&F Polycarbonate fabricated cable junction box of size 270mm x 225mm x 135mm, outdoor type, cubical, sloping canopy top roof, pole mounted, hinged single door with locking arrangement, front side openable box suitable for three phase, 415 volts, AC supply with 04 Nos Aluminium bus bar rating 32 amps(R.N) with one NoMCB 06 Amps, SPcomplete with flat iron clamp for fixing arrangement including dismantling of old junction box complete all as specified and as directed. |
| 43 | M&L for Flexible cable of size 1.5 Sqmm 3 core with multistranded copper conductor FR round 1100 Volts grade heavy duty cable PVC insulated in street light connection from pole junction box at bottom to street light fittings by making two holes for inserting cable including taking down old cable complete all as specified and as directed. |
| 44 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall/pole with brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 45 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole with brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 46 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 50 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole with brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed. |
| 47 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 70 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole with brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 48 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 95 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole with brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 49 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 120 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole with brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 50 | M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable forprotection of LT cable complete all as specified and as directed. |
| 51 | M&L for boring of hole, horizontally under Road without damaging the surface of road (minimum 1m bellow the road surface) with mechanical arrangement upto 100 mm dia for passing the water pipes/UG cable across the road complete all as specified and as directed. |
| 52 | Supply, installing, testing and commissioning LT Outdoor floor mounted feeder pillar box, powder coated, factory made and tested, (SIZE-1000mm X 1000mm X 450mm) platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars of 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class (IP-43)in accordance with IS-2147. b) and made of 3.00 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mm x 5 mm thick and 450 mm long), front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade. The scope of work also comprising of the following: -BUS BAR CHAMBER: - (a) 250 Amp TPN, Alu. conductor, Supported on insulated plate form, interconnection of all incomings & outgoings = 02 Sets on both sides of panel).INSTRUMENT CHAMBER: - (i) Volt Meter,96mm, flush type rated 0-500V, Digital type with Volt Meter selector switch- 01 Set. (ii) Amp Meter,96mm, flush type rated 0-400A, Digital type with suitable size C. T’s, and Amp Selector switch- 01 Set (iii) RYB Phase indicating light LED type- 01 Set. INCOMING/Main power supply controlling: - (i) MCCB 4 pole ,415 V, of rating 200 Amp 25 KA- 1 No. (NOTE: All the MCCB with Rotary Mechanism Handle.Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible. |
| 53 | Supply, installing, testing and commissioning LT Outdoor floor mounted BUS BAR box, powder coated, factory made and tested , (SIZE-750mm X 500mm X 450mm) platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars of 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class (IP-43) in accordance with IS-2147. b) and made of 3.00 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mm x 5 mm thick and 450 mm long), front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade. The scope of work also comprising of the BUS BAR CHAMBER: - (i) 400 Amp TPN, Aluminium conductor - 2 nos, Supported on insulated platform, interconnection of all incomings & outgoings.(ii) RYB Phase indicating light LED type- 01 Set. |
| 54 | M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25mmx4mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm dia (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing on completion including demolition of old earthing complete all as specified and as directed. |