| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 2 | Taking down old sub-main wiring incl fixture & fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 3 | Disconnecting/dismantling of old existing un serviceable DB\"s any type/way 240/415 Volts with their old/un serviceable burnt MCCB/MCB\"s etc. complete all as specified and directed |
| 4 | Disconnect and taking down existing exhaust fan of size 250mm sweep or 300 mm sweep with louverand hand over to MES store yard for safe custody. |
| 5 | M&L for concealed point wiring with 1.5 Sq mm,FRLS, PVC insulated, single core, sheathed copper conductor cable of 1100 Volt grade, multi stranded in and including rigid non metalic medium grade PVC conduit concealed in wall, includingcontinuous 1.5 Sqmm PVC insulated single core copper conductor cable as earth continuity conductor connected to common earth dolly etc. (a) One light point or one fan point controlled by one switch , complete all as specified and directed |
| 6 | (b) One 3 pin socket outlet, 5 amps, independent, complete all as specified and directed |
| 7 | (c ) One 3 pin socket outlet. 15 amps, independent, with cables 4 sq.mm sizeall as specified and directed. |
| 8 | (d) One light point controlled by two 2 - way switches with cables 1.5 sq. mm size all complete all as specified and directed. |
| 9 | (e) One bell/ buzzer point controlled by one push button on the same board with otherswitches or independent with cables 1.5 sq.mm size complete all as specified and directed. |
| 10 | Material and labour for Point wiring complete with 1.5 sqmm (nominal area) FRLS gradePVC insulated, sheathed stranded copper conductor single core cable 1100 volts grade in and including PVC casing and caping complete(a) One light point or one fan point controlled by one switch complete all as specified and directed. |
| 11 | (b) One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size complete all as specified and directed |
| 12 | (c) One 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size complete all as specified and directed |
| 13 | M&LSwitch piano, flush type single pole, one way 6 Ampall as specified and directed. |
| 14 | M&LSwitch piano, flush type single pole, one way 16 Ampall as specified and directed. |
| 15 | M&L Modular switch 1 way 6A, 1 module all as specified and directed. |
| 16 | M&L Modular switch 1 way 16A, 1 module all as specified and directed. |
| 17 | S & F Socket, 6A - 2/3 pin combined 2 module, all as specified and directed. |
| 18 | S & F Socket 6A/16A - 2/3 pin combined 2 module, all as specified and directed. |
| 19 | M&L PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep allas specified and directed. |
| 20 | All as per item No 13 but size 175x100x50 mm deep all as specified and directed. |
| 21 | All as per item No 13 but size 200x150x50 mm deep all as specified and directed. |
| 22 | S&F Modular White cover plate with frame, 1 module all as specified and directed. |
| 23 | S&F Modular White cover plate with frame, 2 module all as specified and directed. |
| 24 | S&F Modular White cover plate with frame, 3 module all as specified and directed. |
| 25 | S&F Modular White cover plate with frame, 4 module all as specified and directed. |
| 26 | S&F Modular White cover plate with frame, 6 module all as specified and directed. |
| 27 | M&L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 28 | M&L Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed |
| 29 | M&L Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body all as specified and directed |
| 30 | S&F MCB DB SPN 4 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar, sunken to wall including necessary dummy plate and necessary complete all as specified and directed. |
| 31 | (a) All as per item No 24 but 8 wayall as specified and directed. |
| 32 | (b) All as per item No 24 but 12 wayall as specified and directed. |
| 33 | S&F MCB, DB, TPN, 4 ways, 415 Volts DOUBLE DOOR, IP-43, Ik-09 with metal door, rated bus bars, earth bar, neutral links complete including blanking plates as required, fixed flush to wall/other surface complete all as specified and as directed. |
| 34 | (a) All as per item No 25 but TPN 8 way 415 volts,all as specified and directed. |
| 35 | M&L MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and as directed |
| 36 | Supply and fixing in repair SP 6 To 32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. complete all as specified and as directed |
| 37 | (a) All as per item No 27 but SPN 32 Amp complete all as specified and directed. |
| 38 | (b) All as per item No 27 but SPN 40 to 63 Amp complete all as specified and directed. |
| 39 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB Complete with connection testing and commissioning. all as specified and directed. |
| 40 | S & F in repair TPN/FP 40 to 100 Amp, 415V , 10KA \"B\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed |
| 41 | Supply and fixing LED lights fitting 1 x 20W, 220V, AC , (4 ft.) High performanceelectronic driver , operating temperature 10 C to 35 °C operating voltage range 140 V -270 V , Average life 50000 hours and LED lamp including High efficiency long life LED with lumen efficacy of 140 Im/watts and ABS end caps tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 42 | Supply and fixing LED lights fitting 1x 10W, 220V, AC , (2 ft.) High performance electronic driver , operating temperature 10° C to 35 °C operating voltage range 140 V -270 V , Average life 50000 hours and LED lamp including High efficiency long life LED with lumen efficacy of 140 lm/watts and ABS end caps tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed |
| 43 | S&F decorative bulk head edge lit LED luminaire 10Wwith min 120 lumens/watt output IP >= 65,IK>=07, Class I Environment friendly, energy saving, surface mounted, decorative bulk head edge lit LED luminaire 10Wwith min 120 lumens/watt output made of pressure die cast aluminium housing with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed |
| 44 | S&F in repair LEDstreet light /security light luminaries fitting 1X30 watt LED with min 120 lumens/watt output including GI bracket made out of GI pipe light grade 25 mm dia 1.20 m long bent to shape with suitable size mild steel clamps of size 50 X 6mm with nut, bolt, & washers as required at site for fixing of street light on LT poles / wall including making connection with PVC insulated 3 single core of 1.5 sqmm size multistranded copper conductor cable complete all as specified and directed. |
| 45 | S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed |
| 46 | (a) All as per item No 34 but 40 watt complete all as specifeid and directed |
| 47 | S & F in repair round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 48 | (a) All as per item No 35 but 12 Watts Complete all as specified and directed |
| 49 | (b) All as per item No 35 but 15 Watts Complete all as specified and directed |
| 50 | Supply and fixingin repair round shape 18 watt 220 volts AC, IP 20, CRI > 80, CT> 6500 K, THD<10%, min lumen out put 120 lum/watt, surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed.Make Havells or equivalent of philips / lukar |
| 51 | Supply and fixing in repair decorative wall mounting fitting with suitable for 2N X 9 watts withLED lamp , B22 holder type,double arm type Brushed nickel finishing fixture luminaire of double arm withOpal glass diffuser with all accessories internally prewired and including connecting up complete all as specified and as directed. Make: Havells, Cat No.LHFOAJE2TZ1I060 or equivalent make/model of Luker/Jaguar/Crompton/Panasonic etc. |
| 52 | Supply and fixing in repair decorative wall mounting fitting with suitable for 1N X 9 Watts LED lampwith B22 holder type,single arm type Brushed nickel finishing fixture luminaire of double arm withOpal glass diffuser with all accessories internally prewired and including connecting up complete all as specified and as directed.Make: Havells, Cat No.LHFOAJE1TZ1I060 or equivalent Luker/Jaguar/Crompton/Panasonic etc. |
| 53 | S&F in repair decorative Bedside fitting of 5W Chiara wood F4, 240 V AC , 50/60 HZ , 450 lm , PF > 0.95 with all accessories internally prewired and including connecting up complete all as specified and as directed. Make: LukerLWL 120 - 1 or equivalent Havells/Jaguar/philips |
| 54 | Supply and fixing in repair ceiling/wall/panel mounted LED 15 Watt track light (White colour) or next higher rating suitable for Track Channel 1/2 Mtrs span, CRI > 80, CT=6500 K ,twin/three core twisted flexible copper conductor cable of suitable size in flexible conduit all as specified and as directed. . Make: Cat No Cat No :UNECOTRACKLIGHT TS15W LED840S36BLK-V2of Havells or techno-commercially equivalent model in Philips/Luker etc. |
| 55 | Supply and fixingin repair ceiling/wall/panel mounted LED track channel (White colour) 1 Mtrs length suitable for mounting of 03 Nos Tracklights 15 W, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible conductor cable of suitable size complete all as specified and as directed.Make : Havells, 1MTR1PHASETRACKTSWHT-V1or techno-commercially equivalent in Philips/Luker. |
| 56 | Supply and fixing in repair wall mounting decorative display light of rating 15W,IP 20, CRI > 80, CT> 6500 K, THD<10%, min lumen out put 120 lum/watt with aluminum die cast body and PC diffuser with all fixing arrangement forfixing above table and pictured complete all as specified and as directed. Make: Havells, Cat No : UNECOSNOOTDLR15WLED830S36WHT-G2 or techno-commercially equivalent model of in Philips/Luker. |
| 57 | S&F in repair LED strip light, 3000K, 50 meter length incl constant voltage driver of rating 12V DC,High brightness IP65, with uniformity of light required for perfect outdoor application, with suitable fixing arrangement and including driver complete all as specified and as directed. Make: Havells, Cat No : FLEXISTRIP50MIP65AC6W/M830V1 or equivalent make/model of phillips/Panasonic etc. |
| 58 | Supply and fixing in repair ultra modern, recess mounting, 45W, 6500K/3000K (White/WW) IP 20, CRI > 80, THD<10%, min lumen out put 120 lum/watt LED luminaire of size 4\" x 1\" suitable for false ceiling with suitable fixing arrangement incl cutting existing false ceiling any type (if req) & matching complete with existing surface inclelectronic driver & high brightness LEDslight fittings complete all as specified and as directed. make Havellsor equivalent of philips / Lukar |
| 59 | Supply and fixing in repair LED lamps of 9 W , B22 holder type, 6500K, lum 950 lum/watts warm white colour complete all as specified and directed. make Havellsor equivalent of philips / Lukar |
| 60 | Supply and fixing in repair LED lamps of 5 W , B22 holder type, 3000K,lum 950 lum/watts warmwhite colour complete all as specified and directed.make Havellsor equivalent of philips / Lukar |
| 61 | Supply and fixing in repairs LED lamps9W, 6500Klum 950 lum/watts with E-27 base complete all as specified and directed. make Havellsor equivalent of philips / Lukar |
| 62 | Supply and fixing in repairs LED lamps of the 5W, 3000K , lum 500 lum/watts with E-27 base complete all as specified and directed. make Havellsor equivalent of philips / Lukar |
| 63 | Supply and fixing in repairs LED lamps B-22 BaseLED ROJO 7 W B22 RED LAMP,complete all as specified and directed. |
| 64 | Supply and fixing in repairs LED lamps B-22 BaseLED ROJO 7 W B22 GREEN LAMP,complete all as specified and directed. |
| 65 | Taking down old unserviceable geyser carefully and cleaning the inner cylinder, welding leakage, replacement of heating element of appropriate size and capacity and thermostat, glass wool and making good by painting two coat existing colour of enamel paint and refixing at same location or hand over to MES store yard with all connected items e.g. PVC connections, stop valves, single pole enclosure, metal clad socket etc.complete all as specified and directed.Note: All connected items (spare parts) will measured and paid separately. |
| 66 | S&F in repair for PVC connections 15mm size with PTMT nuts of length 300mm PVC connections complete all as specified. |
| 67 | S&F in repair for PVC connections 15mm size with PTMT nuts of length 375mm PVC connections complete all as specified. |
| 68 | S&F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp , 240 Volt ,complete all as specified and directed |
| 69 | S&F in repair heating element of capacity upto 2kW for geysers upto 50 ltrs capacity complete all as specified and directed. |
| 70 | S&F in repair thermostatfor geysers upto 50 ltrs capacity complete all as specified and directed. |
| 71 | S&F in repairs NRV of size 15mm for geyser hot water supply including taking down old unsv NRV complete all as specified and directed |
| 72 | S&F in repairs wall mount brackets for mounting geysers upto 50L capacity including taking down old unsv brackets complete all as specified and directed |
| 73 | Supply and fixCapilary thermal cutout unit with bracket WY-S105N19 andadjustable temperature knob suitable for 25/50 ltrs Geysers of Havells Monza DX and making suitable arrangement for fixing incl taking down old unserviceable thermal cutout complete all as specified and directed. |
| 74 | M&L PVC insulated and PVC round sheathed copper conductor flexible cable 3 core 1.5 Sqmm including taking down old unserviceable copper conductor complete including testing all as specified and directed. |
| 75 | M&L PVC insulated and PVC round sheathed copper conductor flexible cable 3 core 2.5 Sqmm including taking down old unserviceable copper conductor complete including testing all as specified and directed. |
| 76 | M&L for concealed sub main wiring with two single core, multi stranded,FRLS PVC insulated, 1100 Volt grade, cable with multi stranded copper conductor of size 2.5 Sq mm in and drawing throughPVC conduit medium grade including continuous PVC insulated copper conductor single core as earth continuity conductor of size 2.5 Sqmm connected to common earth dolly complete all as specified and directedNote : (i) 3 Runs of 2.5 sqmm cable & one run of medium grade PVC conduit shall be measured as one unit length.(ii) The cost of cutting chases and the cost of making good the disturbed surfaces is deemed to be included in the quoted rate. |
| 77 | All as per Item No 62 hereinbefore but in and incl casing caping all as specified & directed |
| 78 | M&L for concealed sub main wiring with two single core, multi stranded,FRLS PVC insulated, 1100 Volt grade, cable with multi stranded copper conductor of size 4.0 Sq mm in and drawing throughPVC conduit medium grade including continuous PVC insulated copper conductor single core as earth continuity conductor of size 4.0 Sqmm connected to common earth dolly and inculding taking down for old unsvsubmain wiring. complete all as specified and directed. Note : (i) 3 Runs of 4.0 sqmm cable & one run of medium grade PVC conduit shall be measured as one unit length.(ii) The cost of cutting chases and the cost of making good the disturbed surfaces is deemed to be included in the quoted rate. |
| 79 | All as per Item No 64 hereinbefore but in and incl casing caping all as specified & directed |
| 80 | M&L for concealed sub main wiring with two single core, multi stranded,FRLS PVC insulated, 1100 Volt grade, cable with multi stranded copper conductor of size 6 Sq mm in and drawing throughPVC conduit medium grade including continuous PVC insulated copper conductor single core earth continuity conductor of size 6 Sqmm connected to common earth dolly complete all as specified and directed.Note : (i) 3 Runs of 6 sqmm cable & one run of medium grade PVC conduit shall be measured as one unit length.(ii) The cost of cutting chases and the cost of making good the disturbed surfaces is deemed to be included in the quoted rate. |
| 81 | All as per Item No 66 hereinbefore but in and incl casing caping all as specified & directed |
| 82 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified by Engineer-in-Charge |
| 83 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed |
| 84 | M&L for Servicingand testing of Refrigerator/ Deep freezer / any type /any makeincluding taking down unserviceable parts, repair/replacement of compressor, fan motor,indoor coil, outdoor coil, refrigent copper pipe, refilling of gas as per site requirement and all as specified and directed |
| 85 | M&L for Servicingand testing of 2.0 TR / any type /any makesplit type AC (Inverter type) including taking down unserviceable parts, repair/replacement of compressor ,fan motor, pcb, magnetic contactor, indoor coil, outdoor coil, refrigent copper pipe, refilling of gas as per site requirement and all as specified and directed.Note:- Scope of Work(i) the system will be checked for its proper functioning, any defects, if found will be rectified within stipulated time.all defective spares shall be repaired/replaced as and when required during contract. any consumable like oil, refrigerant will also be supplied whenever necessary. (ii) indoor unit filters will be inspected and cleaned as per schedule. (iii) indoor/outdoor unit heatexchanger will be inspected and cleaned as per schedule.(iv) any functional parts like compressor, fan motor, PCB, magnetic contractor, indoor coil, outdoor coil, all type of gas and transformer, refrigent pipe are covered under the quoted rates. (v) testing to be done whenever the Engr-in-charge called duringContract time period.(vi) Air conditioning system (ODU\"s & IDU\"s) will be services & checking 02 times during contract on quarterly basis, one full service included in quoted rate. |
| 86 | Supply and fixing in repair indoor fan motor of suitable capacity for split type AC of capacity1.5 / 2 ton all as specified and directed. |
| 87 | Supply and fixing in repair running capacitor36/45 mfd, 3 pinsuitable for split AC of capacity 1.5 /2 ton all as specified anddirected. |
| 88 | Supply and fixing in repair air filter suitable for split AC of capacity 1.5 / 2 ton all as specified anddirected. |
| 89 | Supply and fixing in repair drain out pipe of required size and length of indoor unit suitable for split AC of cap 1.5/2 ton all as specified anddirected. |
| 90 | Taking out the damaged suction line pipe and supply and fixing new copper pipe of size 1/2\" in brazing, pressure testing for 1.5/2 Ton capacity split type AC all as specified and directed. |
| 91 | M&L for replacement of PVC insulated and sheathed flexible cable 3 core stranded copper conductore of size 4.0 Sqmm in proper size saddle 1100 volts grade after taking out old unserviceable one including electrice connection complete all as specified and as directed. |
| 92 | Supply and fixing in repair relay 5 pin type suitable for 1.5/2 Ton capacity all as specified and as directed. |
| 93 | Supply and fixing in repair over load protector suitable for 1.5/2 Ton capacity all as specified and as directed. |
| 94 | Supply and fixing in repair thermostatic switch suitable for split type AC 1.5/2 Ton capacity all as specified and as directed. |
| 95 | S&F inFRP enclosure of size 1000(L) x 690(W) x 280 (D) approx or next higher size with locking arrangement and making flush to the wall, fixing TPN DB inside with suitable accessoriesincl taking down the old enclosure complete all as specified and directed.Note: The cost of making good the disturbed surface and matching to the existing surface is deemed to be included in the unit quoted rate. (ii) The cost of making cut or hole to the enclosure as per site requirements is deemed to be included in the unit quoted rates. |
| 96 | Taking down carefully unserviceable single phase/three phase energy meter from the meter box and refixing the same energy meter in same qtr/bldg after servicing from approved service centres complete all as specified and directed. |