| 1 | Supply, installation, testing & commissioning of AMF Panels suitable to 200 KVA DG Sets with connected acessories as follows(a) Battery Charger with metering MCB6A, SP, 10KA -10 Nos(b) Electronic circuit boards with phase indication lamp 220 V, AC - 6 Nos(c) Power Relays (Cranking Relays) - 2 Nos(d) Terminal Blocks with digital Volt, Amp and Frequency meter (0-400 A)- 2 Nos(e) Contactor Assembly (2 Nos) - 325A(f) Fuse and safety devices (MCB) C-Curve 10A, DP, 10KA- 2 Nos(g) PLCs with under + over voltage relay - 2 Nos(h) Cable and Connectors with ON Delay Relay - 2 Nos(i) Transformer and Power Supplies as OEM Recommendations(j) Isloatorsas per OEM Recommendations |
| 2 | (k) Aux Contactors 2 NO+NC - 6 Nos(l)MCCBs Thermal 400A, TP, 36 KA - 1 Nos (with Spreader Links)(m) Current Transfomer 400/5A CL-I - 6 Nos(n) Rotary Handles - 1 Nos(o) ON / OFF Indication Lights 220V AC- 4 Nos(p) Start / Stop push button - 2 Nos(q) SMPS 10A, 12V DC - 1 Nowith Auto / manual selector Switch Make : CumminsNote : Excavation, RFR, Removing and necessary foundation / coping shall be inclusive of quoted rate. |
| 3 | Supply, installation, testing & commissioning of AMF Panels suitable to 160 KVA DG Sets with connected acessories as follows(a) Battery Charger with metering MCB6A, SP, 10KA -10 Nos(b) Electronic circuit boards with phase indication lamp 220 V, AC - 6 Nos(c) Power Relays (Cranking Relays) - 2 Nos(d) Terminal Blocks with digital Volt, Amp and Frequency meter (0-400 A)- 2 Nos(e) Contactor Assembly (2 Nos) - 250A(f) Fuse and safety devices (MCB) C-Curve 10A, DP, 10KA- 2 Nos(g) PLCs with under + over voltage relay - 2 Nos(h) Cable and Connectors with ON Delay Relay - 2 Nos(i) Transformer and Power Supplies as OEM Recommendations(j) Isloatorsas per OEM Recommendations |
| 4 | (k) Aux Contactors 2 NO+NC - 6 Nos(l)MCCBs Thermal 400A, TP, 36 KA - 1 Nos (with Spreader Links)(m) Current Transfomer 400/5A CL-I - 6 Nos(n) Rotary Handles - 1 Nos(o) ON / OFF Indication Lights 220V AC- 4 Nos(p) Start / Stop push button - 2 Nos(q) SMPS 10A, 12V DC - 1 Nowith Auto / manual selector Switch Make : CumminsNote : Excavation, RFR, Removing and necessary foundation / coping shall be inclusive of quoted rate. |
| 5 | Supply, installation, testing & commissioning of AMF Panels suitable to 140 KVA DG Sets with connected acessories as follows(a) Battery Charger with metering MCB6A, SP, 10KA -10 Nos(b) Electronic circuit boards with phase indication lamp 220 V, AC - 6 Nos(c) Power Relays (Cranking Relays) - 2 Nos(d) Terminal Blocks with digital Volt, Amp and Frequency meter (0-400 A)- 2 Nos(e) Contactor Assembly (2 Nos) - 250A(f) Fuse and safety devices (MCB) C-Curve 10A, DP, 10KA- 2 Nos(g) PLCs with under + over voltage relay - 2 Nos(h) Cable and Connectors with ON Delay Relay - 2 Nos(i) Transformer and Power Supplies as OEM Recommendations(j) Isloatorsas per OEM Recommendations |
| 6 | (k) Aux Contactors 2 NO+NC - 6 Nos(l)MCCBs Thermal 400A, TP, 36 KA - 1 Nos (with Spreader Links)(m) Current Transfomer 400/5A CL-I - 6 Nos(n) Rotary Handles - 1 Nos(o) ON / OFF Indication Lights 220V AC- 4 Nos(p) Start / Stop push button - 2 Nos(q) SMPS 10A, 12V DC - 1 Nowith Auto / manual selector Switch Make : CumminsNote : Excavation, RFR, Removing and necessary foundation / coping shall be inclusive of quoted rate. |
| 7 | Supply, installation, testing & commissioning of AMF Panels suitable to 125 KVA DG Sets with connected acessories as follows(a) Battery Charger with metering MCB6A, SP, 10KA -10 Nos(b) Electronic circuit boards with phase indication lamp 220 V, AC - 6 Nos(c) Power Relays (Cranking Relays) - 2 Nos(d) Terminal Blocks with digital Volt, Amp and Frequency meter (0-400 A)- 2 Nos(e) Contactor Assembly (2 Nos) - 250A(f) Fuse and safety devices (MCB) C-Curve 10A, DP, 10KA- 2 Nos(g) PLCs with under + over voltage relay - 2 Nos(h) Cable and Connectors with ON Delay Relay - 2 Nos(i) Transformer and Power Supplies as OEM Recommendations(j) Isloatorsas per OEM Recommendations |
| 8 | (k) Aux Contactors 2 NO+NC - 6 Nos(l)MCCBs Thermal 400A, TP, 36 KA - 1 Nos (with Spreader Links)(m) Current Transfomer 400/5A CL-I - 6 Nos(n) Rotary Handles - 1 Nos(o) ON / OFF Indication Lights 220V AC- 4 Nos(p) Start / Stop push button - 2 Nos(q) SMPS 10A, 12V DC - 1 Nowith Auto / manual selector Switch Make : CumminsNote : Excavation, RFR, Removing and necessary foundation / coping shall be inclusive of quoted rate. |
| 9 | Supply, installation, testing & commissioning of AMF Panels suitable to 62.5 KVA DG Sets with connected acessories as follows(a) Battery Charger with metering MCB6A, SP, 10KA -10 Nos(b) Electronic circuit boards with phase indication lamp 220 V, AC - 6 Nos(c) Power Relays (Cranking Relays) - 2 Nos(d) Terminal Blocks with digital Volt, Amp and Frequency meter (0-400 A)- 2 Nos(e) Contactor Assembly (2 Nos) - 250A(f) Fuse and safety devices (MCB) C-Curve 10A, DP, 10KA- 2 Nos(g) PLCs with under + over voltage relay - 2 Nos(h) Cable and Connectors with ON Delay Relay - 2 Nos(i) Transformer and Power Supplies as OEM Recommendations(j) Isloatorsas per OEM Recommendations |
| 10 | (k) Aux Contactors 2 NO+NC - 6 Nos(l)MCCBs Thermal 400A, TP, 36 KA - 1 Nos (with Spreader Links)(m) Current Transfomer 400/5A CL-I - 6 Nos(n) Rotary Handles - 1 Nos(o) ON / OFF Indication Lights 220V AC- 4 Nos(p) Start / Stop push button - 2 Nos(q) SMPS 10A, 12V DC - 1 Nowith Auto / manual selector Switch Make : CumminsNote : Excavation, RFR, Removing and necessary foundation / coping shall be inclusive of quoted rate. |
| 11 | Supply, installation, testing & commissioning of AMF Panels suitable to 58.5 KVA DG Sets with connected acessories as follows(a) Battery Charger with metering MCB6A, SP, 10KA -10 Nos(b) Electronic circuit boards with phase indication lamp 220 V, AC - 6 Nos(c) Power Relays (Cranking Relays) - 2 Nos(d) Terminal Blocks with digital Volt, Amp and Frequency meter (0-400 A)- 2 Nos(e) Contactor Assembly (2 Nos) - 250A(f) Fuse and safety devices (MCB) C-Curve 10A, DP, 10KA- 2 Nos(g) PLCs with under + over voltage relay - 2 Nos(h) Cable and Connectors with ON Delay Relay - 2 Nos(i) Transformer and Power Supplies as OEM Recommendations(j) Isloatorsas per OEM Recommendations |
| 12 | (k) Aux Contactors 2 NO+NC - 6 Nos(l)MCCBs Thermal 400A, TP, 36 KA - 1 Nos (with Spreader Links)(m) Current Transfomer 400/5A CL-I - 6 Nos(n) Rotary Handles - 1 Nos(o) ON / OFF Indication Lights 220V AC- 4 Nos(p) Start / Stop push button - 2 Nos(q) SMPS 10A, 12V DC - 1 Nowith Auto / manual selector Switch Make : CumminsNote : Excavation, RFR, Removing and necessary foundation / coping shall be inclusive of quoted rate. |
| 13 | Supply, installation, testing & commissioning of AMF Panels suitable to 40 KVA DG Sets with connected acessories as follows(a) Battery Charger with metering MCB6A, SP, 10KA -10 Nos(b) Electronic circuit boards with phase indication lamp 220 V, AC - 6 Nos(c) Power Relays (Cranking Relays) - 2 Nos(d) Terminal Blocks with digital Volt, Amp and Frequency meter (0-400 A)- 2 Nos(e) Contactor Assembly (2 Nos) - 250A(f) Fuse and safety devices (MCB) C-Curve 10A, DP, 10KA- 2 Nos(g) PLCs with under + over voltage relay - 2 Nos(h) Cable and Connectors with ON Delay Relay - 2 Nos(i) Transformer and Power Supplies as OEM Recommendations(j) Isloatorsas per OEM Recommendations |
| 14 | (k) Aux Contactors 2 NO+NC - 6 Nos(l)MCCBs Thermal 400A, TP, 36 KA - 1 Nos (with Spreader Links)(m) Current Transfomer 400/5A CL-I - 6 Nos(n) Rotary Handles - 1 Nos(o) ON / OFF Indication Lights 220V AC- 4 Nos(p) Start / Stop push button - 2 Nos(q) SMPS 10A, 12V DC - 1 Nowith Auto / manual selector Switch Make : CumminsNote : Excavation, RFR, Removing and necessary foundation / coping shall be inclusive of quoted rate. |
| 15 | Supply, laying, jointing, testing XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, size of cable 150 Sqmm 3.5 core, conforming to IS 1554 Part I / ISI marked, 1100 Volt grade on cable trays with suitable clamps, saddles, hooks, bolts etc. complete as per specifications and as required. The quoted rate shall include the cost of proper dressing of cables and also providing identification tags as required, complete as specified and directed. |
| 16 | All as per Ser item No 8.00 here in above but cross sectional area 120 Sqmm 3.5 core. |
| 17 | All as per Ser item No 8.00 here in above but cross sectional area 95 Sqmm 3.5 core. |
| 18 | All as per Ser item No 8.00 here in above but cross sectional area 70 Sqmm 3.5 core. |
| 19 | All as per Ser item No 8.00 here in above but cross sectional area 50 Sqmm 3.5 core. |
| 20 | S&F 70mm bore dia DWC (double wall corruguated) pipe conforming to IS: 14930 / IS 16205 for protection of HT / LT Cable including necessary snap fit coupler required for fixing, complete all as specified and directed. |
| 21 | S&F 120mm bore dia DWC (double wall corruguated) pipe conforming to IS: 14930 / IS 16205 for protection of HT / LT Cable including necessary snap fit coupler required for fixing, complete all as specified and directed. |
| 22 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 23 | Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing complete all as specified and directed. |
| 24 | Removing excavated material to a distance n.exc 50 m & depositing where directedat a level n. exc 1.50 m above the starting point, complete as specified and directed. |