| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm each complete all as specified and directed. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 3 | Taking down shutters of any description exc 1 Sqm but n exc 2 Sqm each complete all as specified and directed. |
| 4 | Hacking out old broken glass ( any thickness , size, quality, or description) from metal frame glazed with putty or fixed with beads/clips, rubbish off the premises complete all as specified and directed. |
| 5 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings dressed stonework and pre cast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 6 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed. |
| 7 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick (below or above ground level) and removal of rubbish beyond MOD land complete all as specified and directed. |
| 8 | Taking up or down steel water tubing and connections including cleaning for refixing of pipe 20mm bore dia all as specified and directed. |
| 9 | All as per item No 08 here above but 15 mm bore |
| 10 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etccomplete all as specified and directed. |
| 11 | Demolition of cement concrete unreinforced of any description and in any position not specifically providedand removal of rubbish beyond MOD land complete all as specified and directed. |
| 12 | Taking down existing roof treatment of any description and any type complete all as specified and directed |
| 13 | Dismantling of brick tile or terracing tiles/ APP Membrane with bedding layer of mortar etc and removal of rubbish beyond MOD land completeall as specified & directed. |
| 14 | Excavating in trenches n exc 1.5m wide and n exc 1.5m depth for foundation etc or for shafts, well, cesspits, manholes, pier holes, cable/pole etc n exc 10 sq m on plan and n exc 1.5m depth and getting out in any type of soil complete all as specified and directed. |
| 15 | Returning filling, in including spreading , levelling, watering and well ramming in layers not exc 25 cm each complete all as specified and directed. |
| 16 | Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 17 | Removing excavated material to a distanceexc 250m but n exc 500m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 18 | S&F pressed steel frames for doors/windows of size size 125x60 mm (1.25mm thick MS sheet)with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats and two coats of synthentic enamel paint complete all as specified and directed. |
| 19 | S&F pressed steel frames for doors/windows of size size 105x60 mm (1.25mm thick MS sheet)with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats and two coats of synthentic enamel paint complete all as specified and directed. |
| 20 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat prefinished with UV coating of size 50x125 mm (duble rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/ moisture proof and fire retardant, fixed in position with and including MS hold fast/lugs/SS dash fasteners of required dia and length completeall as specified and directed.Note: (i) For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. (ii) Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 21 | All as srl item No 20 above but size 45x70mm. |
| 22 | M S framed work and angle as in doors or gates of angle etc also fastening and fixing complete all as specified & directed. |
| 23 | M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and as directed. |
| 24 | S&F 35mm thick factory made plain framed panelled shutters of2nd class hard wood, one panels with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both face.The size of rail and stile as per IS-1003 (Part-I)(Larger size to be provided) Kiln seasoned and chemically pressure treated fitted to chowkats including two caots of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 25 | S&F 2nd class hard wood 35mm thick glazed and skeleton door shutters factory made, open rebated and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per section 8 clause 8.20 (a) of SSR Part-I (larger size to be provided)includingtwo coats of synthetic enamel paint over a coat of pink oxide primer complete all as specified and directed |
| 26 | Factory made single extruded dark brown WPC (Wood Polymer Composite) solid decorative type flush door shutter with CNC cutting of 35mm size prefinished with UV coating comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPCto be laminated with PVC foil minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 27 | S&F 18 mm thick HDHMR ( high density high moisture resistance) one side colour laminated as in kitchen cabinet, bed room cup board ward robe, sink/WHB Vanity and like fixed with suitable nails including fixed with suitable edging tape screw to fix with steel/wooden frame complete all as specified and directed. |
| 28 | S&F 05 mm thick HDHMR ( high density high moisture resistance) board as in kitchen cabinet, bed room cup board ward robe and like fixed with suitable nails including fixed with suitable edging tape screw to fix with steel/wooden frame complete all as specified and directed. |
| 29 | Repair to old steel window not exc 1 sqm including replacement of unserviceable/ damagedhinges, all handles, necessarywelding to shutters and chowkhat for making window in serviceable condition, all members grinding to smooth surface and applying redoxide primer to grinded surface, complete all as specified and directed. |
| 30 | S&F Box type Steel windows and ventilators comprised of tubular frameand shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire mesh and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg staydovetailedor welded including 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed. |
| 31 | M & L preparation of old wood or wood based surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamelpaint complete all as specified & directed. |
| 32 | M&L for preparation old steel or iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paintcomplete all as specified and as directed. |
| 33 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed. |
| 34 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed. |
| 35 | S&F in galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed. |
| 36 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane all as specified and directed. |
| 37 | S&F 3 mm thick figured glass , pin head typeand glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane all as specified and directed. |
| 38 | S&F 100 mm size butt hinges (as per sample) medium weight, cold rolled mild steel complete all as specified and directed. |
| 39 | S&F 300 mm long aluminium alloy, sliding door bolt withhasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed. |
| 40 | S&F aluminiumanodized barrel tower bolts 200 mm of extruded section (as per sample) fixed complete all as specified and directed. |
| 41 | S&F 150 mm size aluminium alloy handles, febricated type extruded section(as per sample), complete all as specified and directed. |
| 42 | S&F 300mm, ordinary rat tail door springs for door closer, complete all as specified and directed. |
| 43 | S&F concealed hinge for kitchen cabinet and cupboard shutter complete all as specified and directed. |
| 44 | S&F 25mm curtain rails stainless steel CP Coated with brackets, end bulbs, fancy type, fixed in position (as per sample)complete all as specified and directed. |
| 45 | Brick work with fly ash bricks (Old Size bricks)straight or curved on plan exc 6 mtr mean radius built in CM 1:6complete all as specified and directed. |
| 46 | M&L for Brick work with subclass \"B\" bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:4complete all as specified and directed. |
| 47 | M&L for Brick work with sub class\"B\" bricksstraight or curved on plan to any radius as in half brick thick walls, built in CM 1:4 complete all as specified & directed. |
| 48 | M&L for Rendering 10mm thick on fair faces of brick work, concrete sruface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed. |
| 49 | M&L for Rendering 5mm thick cement plaster on fair faces of brick work, concrete sruface in cement mortar (1:3) as in ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 50 | M&L for rendering 5mm thick plastering in CM 1:3 in on ceiling, soffits of slabs, chajjas, columns and beams etc andfinishing the plastered surface without using extra cement complete all as specified and directed. |
| 51 | M&L for rendering 15 mm thick cemet plaster on fair faces of brick work or concrte surfacesin CM 1:4 in two layers (5mm finishing layer over 10mm base layer) finished even and surface without using extra cement with WPC over finishing layercomplete all as specified and directed.Note: WPC shall be measured and paid seperately) |
| 52 | M&L for rendering or plastering 10 mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas,roof projections, drainge etc including taking out peeled off plaster/ concrete and making the edges in line, in true shape and finishing the surface without using extra cement complete all as specified and directed. |
| 53 | M&L for Forming 12mm thick Expansion joints filled with pre-formed (for crumple joint) bituminous filler and top 30mm primed and sealed with bituminous sealing compound, Grade \"A\" complete all as specified and directed. |
| 54 | M&L for preparation of new plastered surface of external wall and chajjas,making surface smooth using sand paper, priming the surface with alkali resistance primer paintfor external surface, applying one coat of external wall care putty and two coats of exterior emulsion (weather coat) paint complete all as specified & directed. |
| 55 | M&L for preparation of new plastered surface of external wall and chajjas,making surface smooth using sand paper, priming the surface with alkali resistance primer paintfor external surface, applying two coats of cement base paint including curing complete all as specified & directed. |
| 56 | M&L for preparation of new plastered surface of external wall by applying 2mm thick wall care putty and making the surfaace smoothapplying two coats of distemper oil emulsion over a coat of primer of new surface complete all as specified & directed. |
| 57 | M&L for preparation of newly plastered surface ofwall and applying two coats cement base paint mixed with silicon based water repellent compound over a coat of alkali resistance primer paint by roller/brush complete all as specified & directed. |
| 58 | M&L for preparation of new plastered surface ofwall and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified & directed. |
| 59 | M&L for three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and as directed. |
| 60 | M&L two caot of white wash on surface of ceiling including preparation of new plastered surface complete all as specified & directed |
| 61 | M&L for taking down and removal of loose / disintegrated old concrete / plaster, applyingbonding coat of modified styrene butadiene emulsion (SBR Bonding agent i.e.Nitobond SBR 45) in proportion 1 (Nitobond SBR 45) : 1(water) : 3 (OPC) by volume with the brushes etc to bind New Cement plaster/ polymer Modified plaster/ concrete/ screed concrete with old surface etc complete all as specified and directed. |
| 62 | M&L for 15mm thick plaster with polymer modified mortar fortified with styrene butadiene emulsion (NitobondSBR 45 ) in proportion 1:3 by weight 5 litres Nit bond SBR 45 to added to 50 KG Cement with 13 litre water addition, finished surface to match with existing adjoining surface of facia, fins, parapet walls, ceiling, beams and alike complete all as specified and directed. |
| 63 | M&L for preparation of old surface of wall complete removal of existing treatment and applying 2mm thick wall care putty over one coat of primer and making surface even and smooth and applying two coats of oil emulshion distempercomplete all as specified & directed. |
| 64 | M&L for complete removal of old existing treatment including preparation of plaster/unplaster surfaces ofwalls, chajja, fascia etc and applying one coat of external wall care putty and two coat of exteior emulsion paint (weather coat) over a coa of primer any shade or colour complete all as specified and directed. |
| 65 | M&L two caot of white wash on surface of wall including preparation of old plastered surface complete all as specified & directed |
| 66 | M&L two caot of white wash on surface of ceiling including preparation of old plastered surface complete all as specified & directed |
| 67 | PCC type C-1, 1:3:6 (using 20mm graded crushedstone aggregate) as in plinth protection 75mm thick laid in slope finished even and fair including making joints not more than 2.5 m (or as directed) and at corner, filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed. |
| 68 | PCC type C-1, 1:3:6 (using 20mm graded crushedstone aggregate) as in plinth protection 50mm thick laid in alternate bays (not exceeding 2 Sqm each)finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part ofbitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 69 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqmbut not exceeding 0.11 sqmin floor, skirting/dado or verticle surface etc set and jointed(joint free) in neat cement slurry and pointed in coloured cementover 15mm thick screed bed or bedding layer of mortar in CM 1:4 inculidng dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing),rubish off the premises, complete all as specified and directed. |
| 70 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqmbut not exceeding 0.18 sqmin floor etc set and jointed in neat cement slurry and pointed in coloured cementover 15mm thick screed bed or bedding layer of mortar in CM 1:4 complete all as specified and directed. |
| 71 | M&L for glazed ceramic coloured tiles in vertical surface 600x300x7mm thick set and jointedin neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed or bedding layer of mortar in CM 1:4 including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing),rubish off the premises complete all as specified and directed. |
| 72 | M&L green Marble work 18-20mm thick (table rubbed and polished) in cooking plateform,window cill, steps, stair case trade & riser etc in 15 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Bhaislana Zebra complete all as specified & directed. |
| 73 | M&L for 18-20mm thick machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade, mirror polished completeover and including 15 mm thick screed bed or bedding layer of mortar in CM 1:6, complete all as specified and as directed. |
| 74 | M&L for Machine cut kota stone slab flooring 18-20mm thick in riser of steps, skirting, dado and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade, mirror polished complete all as specified and as directed. |
| 75 | S&F15mm bore mild steel tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. |
| 76 | M&L for cutting chases, pinning in brick work,making good to facing where required, pointing in CM 1:3, cutting n.exc. 10cm in girth complete all as specified and directed. |
| 77 | S&F20mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. |
| 78 | S&F 15mm bore dia angle valve / stop valve cast copper alloy capston head chromium plated (as per sample), fancy type ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed. |
| 79 | S&F Stop valve concealed cast copper alloy (ISI Markd) fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch lever handle screwed both ends for iron pipe 15mm bore dia fixed in repair, complete all as specified and directed. |
| 80 | S&F in repair 15mm bore dia Bib taps, cast copper alloy, chromium plated fancy typeISI marked (as per sample) with crutch or butter fly handles, screwed down, screwed for iron pipe complete all as specified and directed. |
| 81 | S&F in repair towel rail, brass, CP 600 mm long 20mm dia pipe of 1mm thick complete all as specified and directed. |
| 82 | S & F in repair brass CP Shower rose with or without swivel joints,(any size) including fixing to steel pipe or union complete all as specified & directed. |
| 83 | S&F 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified & directed. |
| 84 | S&F in repair Vitreous China squatting pan of orissa pattern, size 580x440mm white with CI ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern(including fixingofflush pipe) including provision of cement concrete bedding, in repair complete all as specified & directed. |
| 85 | S&F Vitreous China squatting pan of orissa pattern, size 580x440mm white with CI ‘P’ or ‘S’ trap, front or back inlet but excluding flushing cistern and flush pipe fixed including placing in position in floor and embedded in cushion of PCC 1:7:12 type E-1 and finishing the top surface to match with the existing flooring complete all as specified & directed. |
| 86 | S&F in repair Vitreous china wash down water closet pan pedestal pattern, white (excluding supply of flushing cistern and flush pipes, but including fixing thereof),including making connections to trap, and to flush pipe including plastic seat and cover with stainless steel or aluminised hinging device and fixed complete all as specified and directed. |
| 87 | S & F in repair vitreous china, wash hand basin, white, flat back, of size 400mmx400mm with brackets including cutting for and pinning in ends of brackets, complete all as specified or erecting stand including 32mm full threaded waste coupling and 32mm PVC waste pipe, complete all as specified and directed. |
| 88 | S&FVitreous china wash basin, white flat back, size 550 x 400 mm (as per sample), brackets, CP waste coupling and cutting for and pinning in ends of brackets or errecting standincluding 32 mm diawaste pipe complete all as specified and directed. |
| 89 | S&F 15mm bore pillar tap, copper alloy with capstan head, chromium plated screwed down high pressure, with or without lettered hot/cold with long screwed shanks and fly nuts screwed for iron pipe (fixed in repairs), complete all as specified and directed. |
| 90 | S&F Waste coupling, 32mm dia of PTMT(half or full threaded)(Minimum weight 32mm-45gms/40mm-60 grms) complete all as specified and directed. |
| 91 | S & F 10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets including 32mm dia PVC flush pipe of suitable size and making necessary connections to water supply pipe line and jointing to WC,complete all as specified and directed. |
| 92 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 93 | Rotational moulded polyethlene water storage tanks of capacity exc 500 litres three layers(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existing RCC/PVC tank of any capacity complete all as specified & directed. |
| 94 | Rotational moulded polyethlene water storage tanks of capacity exc 1000 litres three layers(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float complete all as specified & directed. |
| 95 | S&F in repair 20 mm size gun metal globe or gate valves with iron wheel head, screwed both end for iron pipe and fixedcast copper chromium plated fancy type alloy ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed. |
| 96 | S&F 20 mm size gun metal globe or gate valves with iron wheel head, screwed both end for iron pipe and fixedcast copper chromium plated fancy type alloy ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed. |
| 97 | S&F 20mm bore Ball brass valves (as per sample), high pressure with polythene float and flynut complete, screwed down for iron pipe fixed, complete all as specified and directed. |
| 98 | S&F 20mm PVC Nipple suitable for HDPE Water tank (Min Wt 15mm- 38 gms) complete all as specified and directed. |
| 99 | S&F PVC waste pipe 800mm long suitable for 32mm dia waste coupling complete all as specified and directed. |
| 100 | S&F in repair stainless steel corner sheets size not less then 300x300x70mm with chromium plated brackets double guard and railing complete all as specified and directed. |
| 101 | S&F stainless steel kitchen plate rack of size 750 x 900 mm not less than 1mm thick sheet thickness of approved make fixed with mild steel screw complete all as specified and directed. |
| 102 | S&F Chromium plated peg stay 6 hook as per sample approved by Engr-in-charge, complete all as specified and directed. |
| 103 | S&Fkitchen sinks with drainage board made of stainless steel 1mm thick with plugs, washers , PVC waste pipefixed in repair including waste copling; bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915x460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 104 | Vitreous chinaurinal bowl type(back or corner wall type), white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and union for discharge pipe including providing and fixing of PTMT urinal spreader with 15mm dia pipe, complete all as specified and directed. |
| 105 | S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe(minimun weight 60 gms) complete all as specified and directed. |
| 106 | S&F 75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified and directed. |
| 107 | S&F 110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified and directed. |
| 108 | 110mm bore dia PVC (SWR) pipe, double (double Y) in any length with rubber joints, fixed to walls or laid in trenches with PVC brackets/clipscomplete all as specified and directed. |
| 109 | 75mm bore dia PVC (SWR) pipe, double (double Y) in any length with rubber joints, fixed to walls or laid in trenches with PVC brackets/clipscomplete all as specified and directed. |
| 110 | S&FPVC (SWR) 75mm bore vent cowl complete all as specified and directed. |
| 111 | S&F 110mm bore dia PVC (SWR) bends, complete all as specified and directed. |
| 112 | S&F in repair 110mm bore dia PVC (SWR) bends,any radius (larger bore measured), complete all as specified and directed. |
| 113 | S&F in repair 75mm bore dia PVC (SWR) bends,any radius (larger bore measured), complete all as specified and directed. |
| 114 | S&F in repair 110mm bore dia PVC (SWR) reducers, complete all as specified and directed. |
| 115 | S&F PVC floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with or without hole for waste pipe complete all as specified and directed. |
| 116 | S&F in repair 110mm bore dia PVC (SWR) branch piece, single (single Y) equal or unequal with parrallel branches fitted with oval access doors, complete all as specified and directed. |
| 117 | S&F in repair PVC (SWR) 75mm bore Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fitted with ovel access doors, complete all as specified and directed. |
| 118 | S&F in repair 75mm bore pipe PVC (SWR) vent cowl, fixed in repair, complete all as specified and directed. |
| 119 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushedstone aggregate) as in foundation, filling and mass concretecomplete all as specified and directed. |
| 120 | M&L for Reinforced cement concrete 1:1.5:3 using 20mm graded crushedstone aggregate in foundation, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 121 | All as per srl item No 120 abvoe but in columns |
| 122 | M&L for reinforced cement concrete 1:1.5:3 as inlintel beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified & directed. |
| 123 | M&L for reinforced cement concrete M-25 as in slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed. |
| 124 | M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, includingflat rough finished surafaces of concrete complete all as specified and directed. |
| 125 | M&Lformwork to sides of pillars, posts, struts, piers, columns, and stanchions, square, rectangular or polygonal in shape, including flat rough finished surafaces of concrete complete all as specified and directed. |
| 126 | M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar works,flat, rough finished surafaces of concrete; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed |
| 127 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 128 | M&L for Moorum/ red bajri filling in floors or pavings, laid in layers n.exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 129 | M&L for 75mm thick PCC 1:4:8 typeD-2 (using 40mm graded crushedstone aggregate) as in sub floors, sub bases, floors and pavings etc complete all as specified and directed. |
| 130 | M&L for 100mm thick lean Cement Concrete 1:3:6type C2(40mm graded crushed stone aggregate) as insub bases finsihed complete all as specified and directed. |
| 131 | M&L forcement concrete 1:2:4 Type B1 (using 20 mm graded crushedstone aggregate) as seismic, plinth and similar bands, coping, kerbs, cills, steps, parapets, apex stones, bed plates, kerbs, railings upto 60 cm in height,water troughs and the like rounded or chamfered on edges including necessary form work complete all as specified and directedNote : (Item also applied in broken RCC chajjas and roof projection) |
| 132 | M&L forPCC 1:2:4 type B-0 ( using 12.5mm graded crushedstone aggregate) padding as roof , surface finished even and smooth without using extra cement complete all as specified and directed. |
| 133 | M&L 20 mm thick cement plaster in cement mortar 1:4 on brick or concrete surface finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified & directed (WPC shall be measured and paid separately) |
| 134 | M&L for preparation of surfaces and apply first coat fiber reinforced elastomatic liquid water proofing membrane formulated with PU hybrid ploymersand reinfoecing acrylic fibers with sun reflective index(SRI) of 100-110 having maximumelongation of 350% tensile strength od 2.9 Mpa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic presure and reduce surface temprerature upto 10 degree celsius with 33% ditution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 grm/sqm and pastinf it properly with overlaping of 50mm and allow it to dry, Apply second coat of undiluted coat @ 0.45 ltr/ Sqm . Apply third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacture of authorised applicator complete all as specified and directed. |
| 135 | Note for item No 134 :-(a) Cleaning of dust, removal for all loose existing bituminous material manually with heat torch gun to get smooth plain finished surface, removing of vegetation/plantaion with no loose material on surface.(b) Conduct ponding test after 7 days, continnue curing of 14 days.(c) All Shifting/ removing of any wire/cable/AC unit/Water tank of any capacity or other any object as per site requirement an re-fixing the same, if needed shall deemed to be included in the quoted rates by the contractor. (d) Removal of any loose/packed items such as mud phuska, terrace tiles, cement screed bed shall be removed and surface shall be made free from depressions before applying treatment to the roof. Quoted rates shall deemed to be includedthis fact into account and no extra payment shall be made on this account. (e) Contractor shall verify availability of the materials in full qty from market before quoting the rates as no extension of time on this ground shall be granted.(f) All the sample/ make for water proofing material mentioned in item shall be got approved from the GE before procuring bulk quantity of material. |
| 136 | Supply only liquid water proofing compoundcomplete all as specified and directed. |
| 137 | M&L for concrete, breaking, loose concrete, changingofcorressive reinforcement with new reinforcement (if required) and filling plain cement concrete 1:1 1/2 :3 type B0 using 12.5mm graded aggregate at places like chajja, sunchades, roof projection, fascia, etc(using URP as per manufaturer instruction as per direction by Engr-in-charge) complete all as specified and directed. Note :- The cost of scafoldings, formwork, reinforcement etc shall deemed to be included in the quoted rate of item. Reinforcement shall be measured and paid for seperately. |
| 138 | S&F in repair wall mixture with telephonic shower (as per sample) for 15 mm bore pipe, cast copper alloychromium platedcomplete all as specified and directed. |
| 139 | S&F in repairs Sink mixer with regular swining spout wall mounted with connectiong legs & wall complete all as specified and directed.. |
| 140 | M&L for RCC Type B11:2:4 (20mm graded aggregate) as in chajja, fins, fascias, louvres, parapets, ralings exc 60cm in height, newels, balustrade and the like completed all as specified and directed. |
| 141 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors & roofs n exc 20cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exc 10cm but exc 20cm wide, rough finished surfaces of concrete complete all as specified and directed |
| 142 | S&F Mild steelTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed. |
| 143 | S&F Mild steelTMT bars 6-8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed. |
| 144 | M&L for Sand filling under floors 40mm thickincluding watering and consolidation complete all as specified and directed. |
| 145 | M&L for 100mm thick PCC 1:4:8 typeD-2 (using 40mm graded crushedstone aggregate) as in sub floors, sub bases, floors and pavings etc complete all as specified and directed. |
| 146 | M&L for 60mm thickness M-35 grade Machine pressed precast concrete factory madepaver block confirming to IS-15658-2006 (topping thickness not less than 5mm thick with white cement and colour pigment non fadable epoxy coating) complete all as specified & directed. |
| 147 | M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, benching, rounded or chamfered on edges of interlocking tiles completed all as specified and directed. |
| 148 | M&L for providing Plain cement concrete C-2, 1:3:6, using 40 mm graded crushedstone aggregate as in Concrete bed todrain pipes upto 200 boreincluding packing under and haunching against the sides of pipes after they are laid and tested; in cement conctrete typecomplete all as specified & directed. |
| 149 | M&L for providing Plain cement concrete C-2, 1:3:6, using 40 mm graded crushedstone aggregate as in Concrete bed todrain pipes upto 150 boreincluding packing under and haunching against the sides of pipes after they are laid and tested; in cement conctrete typecomplete all as specified & directed. |
| 150 | M&L for reinforced concrete pipes 200mm, classs NP3, laid and jointed complete with collars complete all as specified and directed. |
| 151 | M&L for reinforced concrete pipes 150mm, classs NP3, laid and jointed complete with collars complete all as specified and directed. |
| 152 | M&L for precast RCC 1:2:4 TYPE B-1 as in manhole/ drain covers reinforced with steel bars complete all as specified and directed. |
| 153 | M&L forPCC 1:3:6 Type C-1 (using 20 mm graded crushedstone aggregate) as in copings, benching to manholes, kneelers, apex stones, bed plates, including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 154 | LLDPE Septic Tank, designed to carry sewage and sullage water, capacity 2000 ltrs wall thickness 8-10mm and features like UV stabilisation, crack resistance, manhole access durable, air vent system etc. excavation and earth work in ay type of soil, PCC 1:4:8 below foundation, bent shaft,connection etccomplete all as specified and directed. |
| 155 | M&L for Soakage well of size 1.8m dia, 3.0m effective depth including excavaion and earth work in any type of soil, PCC 1;3;6 type C2 foundation, Honey combing walls in CM 1:4, lintle band, RCC slab in M25, SFRC cover, interconnecting pipes or RCC connection etc, filled with brick bats complete all as specified and shown on drawing No CEPZ/C-TD/013/13 sheet 1/5 to 5/5)Note: TD drawing shall be supplied by the Engineer in Charge. |
| 156 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixturesuch as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 157 | M&L for point wiringusing 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with and including 1.2mm thick GI/MS pressed steel sunken box of pressed steel sunken boxes of adequate size,3mm thick plastic laminated sheet cover fixed with brass screws including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. Note:- 1) Conduit shall be fixed on surface/ceiling with necessay saddles where concealing of conduit is not feasible.2) Rate of supplying and fixing modular GI/MS pressed sunken box with support frame deemed to be included in the quoted rates. |
| 158 | All as per Ser item No 156 but for one two light point controlled bytwo 2 way switch, 5 Amp, 240 Volts. |
| 159 | All as per Ser item No 156 but for One bell/ buzzer point controlled by one bell push 5 Amp, 240 Volts AC. |
| 160 | All as per Ser item No 156 but for one5/6 Amp socket outlet point on same board controlled by one switch. |
| 161 | All as per Ser item No 156 but for one5/6 Amp socket outlet points on independentboard controlled by one switch. |
| 162 | All as per Srl item No 156 here-in-before for one 15/16 amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor. |
| 163 | S&F switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed. |
| 164 | S&F socket outlet 2 in 1, 3 pin, 5/6 Amps, flush type with shutters, 240 volts complete all as specified and as directed. |
| 165 | S&F socket outlet 2 in 1, 3 pin, 5/15 Amp flush type , 240 volts complete all as specified and as directed. |
| 166 | S&F switch 15/16 Amps, flush type, 240 volts complete all as specified and as directed. |
| 167 | S&FBell push, flush type, 5/6 Amp AC 230 Volt etc complete all as specified and directed. |
| 168 | S&F Bell Ding Dong AC 230 Volt, single Pole etc complete all as specified and directed. |
| 169 | S&F switch flush button single pole two way 5 Amp complete all as specified and as directed. |
| 170 | S&F stepped type electronic fan regulator flush type Socket type on the existing phenolic laminated sheet etc. not less than 100 W flush type complete all as specified and directed. |
| 171 | S&F ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals. |
| 172 | S&FLamp holder jumbo, PVC/Polycarbonate type with back plate complete all as specified. |
| 173 | S&F LED lamp 12 watts, rated input voltage 220V AC, 50 Hz, rated lumens 1425 lm, CRI 80, lamp life 15000 hours rated efficacy 95 lm/w, surge protection 3.0 kv, 3 star rated completed all as specified and directed. |
| 174 | M&L for repair to existing switch board by taking out the old existing ser/unsv switches, sockets, regulators any type and refixing the servicable switch/sockets after replacement of old unsv/broken Hylum sheet of thickness not less than 3mm of size upt0 5\"x5\"complete all as specified and directed. |
| 175 | All as per srl item No 173 abvoe but size 8\"x5\". |
| 176 | All as per srl item No 173 abvoe but size 9\"x11\". |
| 177 | M & L for sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 Sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including suitable size concealed rigid medium grade PVC conduit not less than 25mm dia 1.5mm thickwith all accessories incl cutting chases on wall andmaking good to the disturbed surface of wall/floor with cement mortar 1:4 and finishes to match existing surface complete all as specified and directed. |
| 178 | S&F in repalcement of intenso LXS LED Batten 20 watt of size not less than 3\"7\", 6500 K, 230 volts, PF-0.95, CRI-80, life 25000 burning hours, wall mounted complete with all accessories internely pre wired and including connecting up with 3 core twisted flexible copper conductor cable of suitable size complete all as specified and directed. |
| 179 | S&F 20W surface / wall mounted box type batten LED fitting having polycarbonate housing and diffuser and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 180 | S&F in replacement LED mirror light 1x10 Watt 2\" feet prewired with all accessories including lamp complete with all accessories internely pre wired and including connection up with 3 core twisted flexible copper conductor cable of suitable size complete all as specified and directed. |
| 181 | S&Fsurface mounted, bulk head LED luminaire 10 W with and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V, IP 65 protectioncomplete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 182 | S&F LED wall security lights of 35 Watthaving pressure die cast aluminium housing with system lumens efficacy≥100 lumen/W,IP65 protection, IK07 rating,inbuilt electronic driver withPF>0.95 incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable complete all as specified and directed. |
| 183 | S&F LED Building light 60 Watt luminaire, made out of pressure die-cast aluminium housing PC diffuser & integdrated electronic driver with high efficiency, polycarbonate cover IP-65 protection including 32mm bore GI pipe bracted mounted on wall or roof using clamps, nuts bolts, washers, fastners etc including connecting up with 3 core flexible copper conductor cable in flexible conduit pipe of suitable size complete all as specified and directed. |
| 184 | MCB DB, SPN, 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar, neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wallincluding cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 185 | MCB DB, SPN, 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar, neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wallincluding cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 186 | S&F MCB SP 240V, 50Hz, 10 KA of rating5 to 32 Amp, \"C\" series complete all as specified and directed. |
| 187 | All as per Ser item No 185 but for size 32 Amps MCB SPN. |
| 188 | S&F in replacement Triple pole and neutral DB 4 way sheet metal enclosures double door 415 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar or rating not less than 200 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket making good the disturbed surface to match with existing wall, painting the plastering surface with same colour complete all as specified and directed. |
| 189 | S&F MCB TPN 40 to 100 Amps 415 Volts C curve, 50 Hz AC 10 KAcomplete all as specified and directed. |
| 190 | Supply and fixing of 5 star rated BLDC (Brush less direct current motor) ceiling fan 230 volts,single phase of 1200mm sweep duble ball bearing tyoe with minimum air delivery 210 CFM & service value shall not be less than 6.0 B.E.E including blade, down rod, bldc refulator and canopy cover etc, including connecting with 3 core flexible copper conductor cable of size 0.50 Sqmm and including writing of MES Number with synthetic enamel paintcomplete all as specified and directed. |
| 191 | S&F heavy duty 300mm sweep, double bearing copper wounded metallic exhaust fan AC single phase 230/240 V having 1400 ± 50 RPM and power consumption not more thann 45 watt with minimum air delivery 700 CMH including box type square shaped metallic louvers made out of powder coaed CRCA sheet of thickness not less than 01mm alonwith aluminium flaps and fixed with grouting nut & bolts and making the suitable hole of suitable size by breaking the existing wall and making good the disturbed surface by plastering and matching with existing specifications with suitable finishes as per site requirement complete all all as specified and directed. |
| 192 | Supply, laying and testing XLPE insulated, screened, PVC beded galvansized steel strip or wire armoured, electric cable heavy duty 1100 volts gradewith stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and directed. |
| 193 | Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 16 Sqmm 4 core, including taking down old, complete, all as specified and directed.Note : All the cable entires should be through proper metallic cable gland. |
| 194 | M&L for sand filling in trenches as cushion to under ground cables 8 cm thick before laying the cable and 15 cm thick when cables are laid and tested complete all as specified and directed. Note: Only punned thickness i.e 18cm shall be measured and paid. |
| 195 | 40mm dia GI tubing, light grade with all fitting laid in trenches or fixed on wall/under road/ floor or pole by means of GI/MS clamps, nut bolts and washers complete all as specified and directed. |
| 196 | M&L for Sub class ‘B’ bricks old size laid dry, flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed. |
| 197 | Supply and laying in repairs 20mm dia Gun-metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI marked, as per IS:778 complete all as specified and directed. |
| 198 | Cutting old GI pipes 25/40/50/100mm bore dia only and reducing to required length, before laying in positon for insertion of new tees, branches etc for repair works complete all as specified and directed. |
| 199 | S&F in replacement Engrgy meter box cover to enclose 01 No single phase electric meters with hinged type front operated door having transparent acrylic sheet and proper locking arrangement and flush mounting in wall including refixing the servicable electirc meter of any type any capacity complete all as specified and directed. |
| 200 | Earthing complete in repair with galvanized steel earth plate electrode60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009.Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail