Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down centrifugal pump set from existing foundation by disconnecting electrically and mechanically at different locations, transporting it to the workshop, dismantling the pumps & carrying out for repair / maintenance cleaning of inside pump, oiling, greasing, gland packing & for proper alignment including replacement of un-serviceable parts with new ones and refixing existing location after got repaired maintenance / replacement of parts, re-assembling on foundation including replacement of nut, bolt and washers fixing in existing position commissioning and testing including loading / unloading, transportation to and from workshop for pumps of following capacity of any size:-Note : (a) The cost of transportation such as vehicle, T & P and man power deemed to be included in the rate quoted by the contractor.(b) Winding shall be measured and paid separately.(c) Supply only spare parts as mentioned in here-in-after shall be measured and paid separately. |
| 2 | (a) 100 HP |
| 3 | (b) 60 HP to 75 HP |
| 4 | (c) 25 HP to40 HP |
| 5 | (d) 7.5 Hto 15 HP |
| 6 | (e) 3 HPto 5 HP |
| 7 | Taking Down centrifugal pump set from existing foundation and M & L for dismantling of centrifugal motor after disconnecting electrically and mechanically, transporting to workshop for Comprehensive repair and maintenance including loading/unloading and reassembling after necessary repair and rewinding the motor stator/rotor with supper enameled copper winding wire of existing size, gauge and turns etc including Spare parts, all the insulating material i.e. varnish, supper high quality cotton tape, insulating paper or soldering etc. including drying up to desired temperature for specific time complete all as specified and directed by Engr-in-Charge for the following capacity of any size :-Note : (a) Rewinding warranty of centrifugal pump shall be of 06 months from installation (b) UNSV PUMP/ Motor should be attendon the same day and re installed within 48 Hours incl Sunday and holyday when and after intimation forfailure ofmotor (c) A recovery Rs 1000 per day for Late Installation/ not attend the centrifugal motor |
| 8 | (a) 100 HP |
| 9 | (b) 60 HP to 75 HP |
| 10 | (c) 25 HP to40 HP |
| 11 | (d) 7.5 Hto 15 HP |
| 12 | (e) 3 HPto 5 HP |
| 13 | Material & Labour for painting of centrifugal pump set with one coat of synthetic enamel paint of approved colour or shade as approved by Engineer-in-Charge including preparation of surface after removing existing paint & filling depressions complete all as specified & directed by Engr-in-Charge including writing of SM No and MES No on the pump set for the following capacity:- |
| 14 | (a) 100 HP |
| 15 | (b) 60 HP to 75 HP |
| 16 | (c) 25 HP to40 HP |
| 17 | (d) 7.5 Hto 15 HP |
| 18 | (e) 3 HPto 5 HP |
| 19 | Supply only of following parts for Centrifugal pump set of capacity 100 HP :- |
| 20 | (a) Ball bearing for motor of existing size |
| 21 | (b) Ball bearing for pump set of existing size |
| 22 | (c)Impeller made out of brass of existing size |
| 23 | (d) Glands bush |
| 24 | (e)Neck Ring |
| 25 | (f) Coupling complete of existing size |
| 26 | (g) Pump shaft including key |
| 27 | (h) Rubber bush including nut bolt and washer complete |
| 28 | (j) Sleeves |
| 29 | Supply only of following parts of Centrifugal pump set of capacity 60 to 75 HP:- |
| 30 | (a) Ball bearing for motor of existing size |
| 31 | (b) Ball bearing for pump set of existing size |
| 32 | (c)Impeller made out of brass of existing size |
| 33 | (d) Glands bush |
| 34 | (e)Neck Ring |
| 35 | (f) Coupling complete setof existing size |
| 36 | (g) Pump shaft including key |
| 37 | (h) Rubber bush including nut bolt and washer complete |
| 38 | (j) Sleeves |
| 39 | Supply only of following parts of Centrifugal pump set of capacity 25 to 40 HP:- |
| 40 | (a) Ball bearing for motor of existing size |
| 41 | (b) Ball bearing pump set of existing size |
| 42 | (c)Impeller made out of brass of existing size |
| 43 | (d) Glands bush |
| 44 | (e)Neck Ring |
| 45 | (f) Coupling complete setof existing size |
| 46 | (g) Pump shaft including key |
| 47 | (h) Rubber bush including nut bolt and washer complete |
| 48 | (j) Sleeves |
| 49 | Supply only of following parts of Centrifugal pump set of capacity 7.5 to 15 HP:- |
| 50 | (a) Ball bearing for motor of existing size |
| 51 | (b) Ball bearing pump set of existing size |
| 52 | (c)Impeller made out of brass of existing size |
| 53 | (d) Glands bush |
| 54 | (e) Neck Ring |
| 55 | (f) Coupling complete setof existing size |
| 56 | (g) Pump shaft including key |
| 57 | (h) Rubber bush including nut bolt and washer complete |
| 58 | (j) Sleeves |
| 59 | Supply only of following parts of Centrifugal pump set of capacity 3 to 5 HP:- |
| 60 | (a) Ball bearing for motor of existing sizes and make. |
| 61 | (b) Ball bearing pump set of existing size |
| 62 | (c) Glands bush |
| 63 | (d) Neck Ring |
| 64 | (e) Coupling complete setof existing size |
| 65 | (f)Pump shaft including key |
| 66 | (g) Rubber bush including nut bolt and washer complete |
| 67 | (h) Sleeves |
| 68 | Taking out Submersible Pump Set of different capacity at different locations along with Column pipe of 80 to 100 mm bore with Submersible cable from the bore well of depth ranging from 30 Mtr to 90 Mtr and transporting it to work shop for dismantling / opening for repair & taking out unserviceable parts of capacity 5 to 35 HP including loading / unloading and transportation to and from work shop complete all as specified and as directed.Note : Supply only of spare parts shall be measured and paid separately |
| 69 | Lowering and re-fixing of submersible pump set of 5 HP to 35 HP at different locations including pump set installation, commissioning and testing after repair & replacement of un-serviceable parts with existing column pipe 80/100mm bore with existing serviceable cable including tightening of rope to the pump by suitable arrangement of chain pulley system and connection with starter electrically and connection with pipe line mechanically complete all as specified and as directed. |
| 70 | M & L for rewinding the subersible motor stator/rotor with supper enameled copper winding wire of existing size and gauge and turns etc including all the insulating material i.e. varnish, supper high quality cotton tape, insulating paper or soldering etc. including drying up to desired temperature for specific time complete all as specified and directed by Engr-in-Charge of the following capacity of submersible pump:-Note : (a) Rewinding warranty ofsubmersible pump shall be of 06 months. (b) UNSV PUMP/ Motor should be installed within 24 Hours when and after intimation forfailure ofmotor (c) A recovery Rs 1000 forLate Installation of pump (d) Before installation of motor / Pump,it should be ensure thatall unsv spare parts of Motor / Pump as given below are replaced (e) Spare parts shall be measure and paid separately. |
| 71 | (a) 35 HP |
| 72 | (b)25HP |
| 73 | (c)20 HP to 22.5 HP |
| 74 | (d)15 HP to 17.5 HP |
| 75 | (e) 5 HP to 12.5 HP |
| 76 | S & F in repairs following parts of SubmersibleMotor 5 HP to 35 HP capacity suitable for any size of dia:- |
| 77 | (a) Motor bearing bush |
| 78 | (b) Motor base complete |
| 79 | (c) Motor base plate |
| 80 | (d) Bearing Upper Housing |
| 81 | (e) Bearing Lower Housing |
| 82 | (f) TB axial |
| 83 | (g) RT Disc |
| 84 | (h) Upper/ lowerFlange |
| 85 | (j) Cable joint |
| 86 | (k)Starter Circlip |
| 87 | (l) Rotor circlip |
| 88 | (m) Motor Coupling |
| 89 | (n) Rotor sleeve |
| 90 | (o) Water seal \"O\" Ring |
| 91 | (p) Upper/Lower Flange stud |
| 92 | (q) TB Housing |
| 93 | (r) Adopter stud |
| 94 | (s) Water seal |
| 95 | (t) T Bolt upper/ lower |
| 96 | (u) Stud O Ring |
| 97 | (v) Sand guard |
| 98 | (w) Pressure cup equalizer |
| 99 | (x) Rocker |
| 100 | (y) Coupling Key |
| 101 | (z) C IBearing |
| 102 | (aa) Cable clip |
| 103 | (ab) Drain plug |
| 104 | (ac) Stud |
| 105 | (ad) Balancing ring |
| 106 | (ae) Rotor nut |
| 107 | S & F in repairs following parts of Submersible Pump 5 HP to 35 HP capacity suitable forany size of dia:- |
| 108 | (a) Neck Ring |
| 109 | (b) Bearing bush |
| 110 | (c) Bearing sleeve |
| 111 | (d) Impeller |
| 112 | (e) Stage Casing |
| 113 | (f) Suction Housing |
| 114 | (g) Distance sleeve |
| 115 | (h) Pump Coupling |
| 116 | (j) Locking screw |
| 117 | (k) Stainer |
| 118 | (l) DOL bush |
| 119 | (m) DOL Sleeve |
| 120 | (n) Distance bush |
| 121 | (o) Body Nut |
| 122 | (p) Body stud |
| 123 | (q) Pump Shaft |
| 124 | (r) Pump Shaft Key |
| 125 | (s) Intermediate piece |
| 126 | (t) Intermediate sleeves |
| 127 | (u) Suction housing bush |
| 128 | (v) Stem |
| 129 | (w) NRV body |
| 130 | M&L for Rotor Machining, Grinding & balancing of 5 HP to 35 HP capacity Pump set complete all as specified and as directed. |
| 131 | M&L Impeller Machining & Balancing of 5 HP to 35 HP capacity pump set complete all as specified and as directed. |
| 132 | M & L for replacement of rotor of the submersible motor 3 phase 415 Volt 50 Hz AC for following capacity:- |
| 133 | (a) 35 HP |
| 134 | (b)25HP |
| 135 | (c)20 HP to 22.5 HP |
| 136 | (d)15 HP to 17.5 HP |
| 137 | (e) 5 HP to 12.5 HP |
| 138 | M& L for replacement of stator of the submersible motor 3 phase 415 volts 50 Hz AC for following capacity of any size:- |
| 139 | (a) 35 HP |
| 140 | (b)25HP |
| 141 | (c)20 HP to 22.5 HP |
| 142 | (d)15 HP to 17.5 HP |
| 143 | (e) 5 HP to 12.5 HP |
| 144 | Supply, lifting and lowering in repair/replacement of GI Heavy duty column pipe 100mm (4\" bore), 3 Mtr long ,ISI marked with 100mm long threaded socketheavy duty for lowering of submersible pump in bore well complete all as specified and as directed. |
| 145 | Supply, lifting and lowering in repair/replacement of GI Heavy duty column pipe 80mm (3\" bore), 3 Mtr long ,ISI marked with 100mm long threaded socket heavy dutyfor lowering of submersible pump in bore well complete all as specified and as directed. |
| 146 | Cutting and threading 80mm (3\" bore) both end MS / GI column pipe heave duty 3 Mtr longincludingheavy duty new socket 80mm bore 100 mm long complete all as specified and directed. |
| 147 | Cutting and threading 100mm (4\" bore) both end MS / GI column pipe heave duty 3 Mtr longincludingheavy duty new socket 100mm bore 100 mm long complete all as specified and directed. |
| 148 | S&F in repairs PVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 4 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990including jointing connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed. |
| 149 | S&F in repairs PVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 6 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990including jointing connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed. |
| 150 | S&F in repairsPVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 10 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990including jointing, connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed. |
| 151 | M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate size as in thrust block / support pillar for pipe holding with MS clamps 50 x 6 mm including finishing the concrete surface fair and even with out using extra cement making good to disturbed surfaces complete all as specified and as directed. |
| 152 | M&L for fittings for spigot socketed cast iron pipes 80 to 300mm bore such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, \"Y\" junction, double branch, cross (all sockets or socket and spigot), collars, caps and plugs complete all as specified and as directed. |
| 153 | M & L for MS clamps for suitable sizes from flat iron/ structural steel sections as per site requirement including nuts, bolts, washers, welding, bending cold or hot, drilling holes bolts, sockets etc any shape or size complete all as specified and as directed. |
| 154 | Supply, install, test and commissioning in repair/replacement of submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-20 mortar, 28 to 42 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. (Suitable for 15 to 22.5 HP submersible pump) |
| 155 | Supply, install, test and commissioning in repair/replacement of submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-30 mortar, 30 to 50 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. (Suitable for 25 HP Submersible pump) |
| 156 | Supply, install, test and commissioning in repair/replacement of submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-40 mortar, 30 to 50 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. (Suitable for 35 HP Submersible pump) |
| 157 | S & F in repair/replacement of DOL starter 240/ 415 volt suitable for 3 to 10 HP motor pump set as per requirement at site complete all as specified and as directed. |
| 158 | Supply & testing in repair/replacement of submersible pump starter fully automatic star delta starter in sheet metal enclosure type MN 110F motor, 30-50 Amp relay max range rating AC 3 phase 415 Volt 50 Hz conforming to IS / IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON / OFF Voltage and ampere complete all as specified & directed. |
| 159 | Repair/ maintenance of Decrin Dozer and replacing defective parts/ spares including testing and commissioning complete all as specified and directed.Note : Quoted rates for spares are inclusive of repair/ replacement of Decrin Dozer. |
| 160 | (a) Roller assembly (PK-4) |
| 161 | (b) Pump tube (PK-5) |
| 162 | (c) Weighted suction line strainer 3/8\" |
| 163 | (d) 3/8\" white suction / discharge tube |
| 164 | (e) Check valve duckbill only (PK-5) |
| 165 | (f) Connecting nut 3/8\" |
| 166 | (g) connecting nut 3/8\" with adapter (PK-5) |
| 167 | (h) GI fitting for Doser including gate valve |
| 168 | (j) NRV suitable for Decrin Dozer |
| 169 | Supply and fix in replacement of water level indicator in repairs at OHT in existing position with MS/GI float of 300mm dia & 400mm long, hollow box of 16 gauge copper sheet fixed to stranded steel wire rope of required length including brass pullies with nylon bush and 50x50x6mm angle iron brackets for pullies, indicator board shall be of 10 gauge of MS plate 200mm wide fixed on angle iron frame 30x30x5mm with angle iron stiffners and after preparation of surfaces, board shall be painted with two coats of synthetic enamel paint over & including a coat of red oxide primer & marking of levels on front face of board with black synthetic enamel paint as per existing pattern or as directed by Engr-in-Charge including all necessary fixing arrangements for fixing of level indicator board as per site requirements complete all as specified and directed. Notes: (i)Quoted rate shall be deemed to be inclusive of all materials & labours, all tools/plants, scaffolding with steel props for working upto approximate 25 M height as per site conditions and as directed. (ii)It shall be prime responsibility of the firm / contractor to provide all necessary safety arrangements like safety belts, ropes, helmets, netting etc to all workers for their safety at working site for work at any height and during working hours, if any casualty happened, only firm / contractor shall be responsible for the same and Government shall not be responsible for any compensation to workers or any other liability but firm\"s / contractor\"s quoted rates shall be deemed to be inclusive all these aspects. |
| 170 | Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all as specified & directed. |
| 171 | Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etccomplete all as specified & directed. |
| 172 | Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 coreincluding taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all as specified & directed. |
| 173 | Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 coreincluding taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all as specified & directed. |
| 174 | S&F in repairtesting and commissioning PVC unsheathed flexible copper cable 1100 volts grade of size 2.5 Sqmm (three runs of single core). Complete all as specified and as directed |
| 175 | Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheeting of PVC tape and overall PVC sheathed in service connection, twin core 10Sqmm stranded aluminum conductor cable flat or circular complete including dismantling of existing service connection all as specified and directed. |
| 176 | Material & Labour for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate notless than 1.5 mtr below normal ground level) connected to galvanised earth strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in electrical plate No 3 of SSR-2009 (Part-I)including charcoal dust common salt,20mm bore GI medium grade watering pipe with funnel along with wire mesh, including 40mm dia GI pipe medium grade [Minimum 5 m in length] for protection of GI earth wire, including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm dia TMT steel bars spacing @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note:- If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost. |
| 177 | S & F in repair earth continuity conductor or main earthing lead with galvanized iron strip of size 32 x 6 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in pipe or any other indicated location for loop earthing etc as required complete all as specified and directed. |
| 178 | Supply and fixing in repairMCCB 4 pole 63 Amps, 415 volts adjustable type with breaking capacity 16KA on LT panel/feeder pillar box etc complete all as specified and directed. |
| 179 | Supply and fixingin repair MCCB 4 pole 100 Amps, 415 volts adjustable type with breaking capacity 16KA on LT panel/feeder pillar box etc complete all as specified and directed |
| 180 | Supply and fixingin repairMCCB 4 pole 160 Amps, 415 volts adjustable type with breaking capacity 36KA on LT panel/feeder pillar boxetc complete all as specified and directed |
| 181 | Supply and fixingin repairMCCB 4 pole 250 Amps, 415 volts adjustable type with breaking capacity 36KA on LT panel/feeder pillar boxetc complete all as specified and directed |
| 182 | Supply and fixingin repairMCCB 4 pole 400 Amps, 415 volts adjustable type with breaking capacity 36KA on LT panel/feeder pillar box etccomplete all as specified and directed. NOTE for item No 43 to 47 : Suitable cable lugs and necessary minor modifications such as making additional holes/ cutting slots etc in the MCCB enclosure if found required at site for fixing the MCCB . The the rate quoted by bidder shall deemed to be included in the quoted rate. |
| 183 | Repair / Servicing of LT panel board with starter all model MUG of L&T of submersible pump in each pump house including making fresh connections of cables, new lugs, painting of LT panel, cleaning etc complete all as specified & as directed |
| 184 | Collect & Testing of water sample obtained in bore wells / swimming pool from Authorised Test Laboratory and submit the test report for record purpose complete all as specified and as directed by Engr-in-Charge.Testing criteria of water as follows :- Colour, Hazen unit -5, Odour- unobjectionable, Taste- Agreeable, Turbidity, NTU- 5, pH Value- 6.5 to 8.5, Hardness- 300PPM, Iron- 0.3mg/l, Chloride-<=250mg/l, Fluoride<= 1.0mg/l, Residual chlorine<=0.2mg/l, Total Dissolved Solid -263mg/l |
| 185 | Supply & Fixing in replacement of terminal plate with 06 Nos copper lugs suitable for 35/50 Sqmm copper cable 3.5 core for 100 HP pump set complete all as specified and as directed. |
| 186 | Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan, in soft and loose soil and getting out for foundation, trenches or laying of electric cable or pipes complete all as specified & directed. |
| 187 | Returning, filling in, excavated soil including spreading, leveling, watering and well rammingin layers not exceeding 25cm thick complete all as specified and directed. |
| 188 | Removal of excavated materials (soil) to a distancenot exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed. |
| 189 | S & F of DWC Pipe IS-16205, outer dia 50 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed. |
| 190 | Supply and fixing of High intensity HIP reflective sign board made from hardened plastic aluminium combined sheet 2 mm thick (with high quality lamination), two sheets placed back to back aluminium pop riveted to stainless steel square pipe 40 x 40 mm of 16 gauge, frame of size 1300 x 840 mm. Frame supported with 25 mm and 50 mm round 2700mm long stainless steel pipe of 16 gauge welded to frame. Top end of legs closed with decorative stainless steel dome place. All stainless steel parts polished on plastic aluminium combined sheet, HIP blue reflective sheet shall be pasted on both side and with white fluorescent computer cut tape minimum 110mm height to be pasted on sign board and border of white HIP sheet shall be pasted and fixed in PCC (1:2:4) type B1 including dismantling existing old vintage damaged standing sign board, complete all as specified and directed by Engr-in-Charge. |
| 191 | S&F in repairchange over switch 4 pole 100 Amp, 415 Volts, Onload type, front handle type with enclosure including connection and testing complete all as specified and directed. |
| 192 | S&F in repairchange over switch 4 pole 200 Amp, 415 Volts, Onload type, front handle type with enclosure including connection and testing complete all as specified and directed. |
| 193 | Dismantling of existing valve pit and M&L for construction of masonry valve pitwith the following specification:- Brick work in CM (1:4) with sub class \"B\" bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 120cmX120cmX3mm MS sheet for cover, angle iron 50cmx50cmx6mm for frame all around with suitable handle with locking arrangement includingtwo coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specifiedand shown on drawing |
| 194 | Dismantling of existing valve pit and M&L for construction of masonry valve pitwith the following specification:- Brick work in CM (1:4) with sub class \"B\" bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1000 x 1000x1000 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 100cmX100cmX3mm MS sheet for cover, angle iron 50cmx50cmx6mm for frame all around with suitable handle with locking arrangement includingtwo coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specifiedand shown on drawing |
| 195 | M&L in replacement ofcontrol wiring / motor starter wiring of pump motor starter panel with PVC insulated copper contactor of sizes 4/6/10/50/70 sqmm all as specified and directed. |
| 196 | S&F in replacement ofMS Nut bolts machine made with hexagonal or square head at one end screwed the other, each screws and to be fitted with washers and nut, exc 5 cm but not exc 10 cm long and dia of bolt 10cm complete all as specified and directed. |
| 197 | M&L in replacement for MS tail piece 6\" dia length required on site both end flanged with nuts bolt and rubber flanged complete all as specified and directed. |
| 198 | M&L for Repair to pump house bore well cap cover made out frommild steel sheet 3 mm thick and angle iron frame in any shape and size complete with making holes , nut bolts welding etc as reqd at site including painting of two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 199 | M & Lin replacement CI non return valve of bore 150 mm dia ,ISI marked complete all as specified and as directed |
| 200 | M & Lin replacement CI non return valve of bore 100 mm dia ,ISI marked all as specified and directed |
| 201 | M& L of repairing/ welding of pipe/ fitting of size 80 to 200mm including excavation in soft/dense soil & taking up pipe/fitting of size 80 to 200 mm dia GI/PVC cutting, rethreading/jointing the pipe and replacing unserviceable fitting returning and filling the excavated soil and testing the joint.Note:- Necessary Excavation upto 0.60 cum shall be included in the job complete all as specified and directed. |
| 202 | S&F in replacement of the following stainless steel spindle suitable for following dia of sluice valve complete with stainless steel nut and threading as per sample & directed by engr-in- charge |
| 203 | (a) 200mm bore sluice valve |
| 204 | (b) 150mm bore sluice valve |
| 205 | (c) 100mm bore sluice valve |
| 206 | (d) 80mm bore sluice valve |
| 207 | M&L in replacement Gun metal globe/gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 50mm bore dia steel tubing complete all as specified and as specified and as directed . |
| 208 | -ditto- above, but for40 mm bore complete all as specified and as specified and as directed . |
| 209 | -ditto- above, but for25 mm bore complete all as specified and as specified and as directed . |
| 210 | -ditto- above, but for20 mm bore complete all as specified and as specified and as directed . |
| 211 | M & L in replacement for gland packing of suitable size of existing sluice valve of size 3\", 4\", 6\", 8\" & 10\"complete all as specified and as specified and as directed (Each roll of 6 pieces) . |
| 212 | M&L in replacementfor chlorine test kit with coloured sample complete with all testing fitments and OT solutionin rexene finish box complete all as specified and as directed. |
| 213 | Supply only OT solution for chlorine test 500 ML bottle complete all as specified and as directed. |
| 214 | S&F rubber gasketjoint for flanged end pipe & fittings of size80mmdiato 200mm dia complete all as specified and as directed . |
| 215 | M&L for cleaning away all grass vegetation, scalping shrubs bushes under growth roots and trees up to zero level not exceeding 30 cm girth and removing rubbish up to distance of 50 mtr out the periphery of area under cleanness complete with tractor/JCB plants/ Manpowercomplete all as specified and as directed. |
| 216 | M&L for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work complete all as specified and directed. |
| 217 | M&L in replacement Run lead joint complete with spun yarn packing & filling properly with lead pigof200 mm dia/bore pipe, complete all as specifiedand as directed |
| 218 | M&L in replacement Run lead joint complete with spun yarn packing & filling properly with lead pig of 150 mm dia/bore pipe, complete all as specifiedand as directed |
| 219 | M&L in replacement Run lead joint complete with spun yarn packing & filling properly with lead pig of 100 mm dia/bore pipe, complete all as specifiedand as directed |
| 220 | S&F in replacement of U/S electronic timers 380/415V, 50Hz range 3-10, 9-30, 30 -120 seccomplete all as specified and directed. (Suitable for 15 to 35 HP Submersible Pump set) |
| 221 | S&F in replacement of U/S Volt meter / Ampere meter as suitable existing approx CT ratio-100/5 & 30/5complete all as specified and directed .(Suitable for 15 to 35 HP Submersible Pump set) |
| 222 | S&F in replacement of U/S selector switch for ampere meter/voltmetercomplete all as specified and directed .(Suitable for 15 to 35 HP Submersible Pump set) |
| 223 | S&F in replacement of U/S LED indicator lamp (Green, Red, Yellow ) 220V 50Hz complete all as specified and directed.(Suitable for 15 to 35 HP Submersible Pump set) |
| 224 | S&F in replacement of U/S ON/OFF push buttoncomplete all as specified and directed .(Suitable for 5 to 35 HP Submersible Pump set) |
| 225 | S & F Power contactor MU 2, 3 pole rating not less than 32 A with 230 coil complete all as specified. (Suitable for 15 HP to 22.5 HP Submersible Pump set) |
| 226 | S & F Power contactor ML-2, 3 pole rating not less than 40 A with 230 coil complete all as specified. (Suitable for 25 HP to 35 HP Submersible Pump set) |
| 227 | S & FPower contactor MNX 110 , 3 pole rating not less than 100 A with 415V complete all as specified. (Suitable for 60 HP to 75 HP Centrifugal Pump set) |
| 228 | S & FPower contactor MNX 140 , 3 pole rating not less than 100 A with 415Vcomplete all as specified. (Suitable for 100 HP Centrifugal Pump set) |
| 229 | S&Fthermal protectionoverload RELAY with built in earth fault relay, 20 to 32 amp, 230/415V coil complete all as specified. (Suitable for 15 HP to 22.5 HP Submersible Pump set) |
| 230 | S&Fthermal protection over load RELAY with built in earth fault relay , 28 to 45 amp, 230/415V coil complete all as specified. (Suitable for 25 to 35 HP Submersible Pump set) |
| 231 | S&F Thermal protectionover load RELAY with built in earth fault relay, 66 to 110 amp, MN5up to 500V complete all as specified. (Suitable for 60 HP to 100 HP Centrifugal Pump set) |
| 232 | M & Lin replacementFootvalve of bore 80-100 mm dia, ISI markedincluding allfitting , nut , bolt etc complete all as specified and directed |
| 233 | M & Lin replacementFootvalve of bore 150 mm dia, ISI markedincluding allfitting , nut , bolt etc complete all as specified and directed . |
| 234 | S & F in repairs aluminium cable lugs of size 3.5/4 core, 16 sqmm to 120 sqmm complete all as specified and directed. |
| 235 | S & F in repair MCCB enclosure of suitable size for mounting of MCCB of 63-400 Amps, 4 pole complete all as specified and directed.NOTE:-Suitable cable lugs and necessary minor modifications such as making additional holes/ cutting slots etc in the MCCB enclosure if found required at site for fixing the MCCB . The the rate quoted by bidder shall deemed to be included in the quoted rate. |
| 236 | Supply, install, testing and commissioning in repleacement of LT Feeder pillar Box, AC, 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 100A electricalgrade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed:-Note:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 237 | (a) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming) |
| 238 | (b) MCCB FP 40 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 02 Nos (outgoing) |
| 239 | (c) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing) |
| 240 | (d) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No |
| 241 | (e) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 02 Nos |
| 242 | (f) Fully automatic Motor Starter (Star-Delta) suitable for 25 HP centrifugal Pump set, 3 Phase - 02 Nos |
| 243 | (g) Single phase preventer, over load relays of suitable rating - 02 Nos |
| 244 | (h) Voltmeter 0-500 V digital type with selector switch - 1 No |
| 245 | (j) Indicator lamp LED type - 3 Nos (R, Y & B) |
| 246 | Supply, install, testing and commissioning in repleacement of LT Feeder pillar Box, AC, 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 100A electricalgrade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed:-Note:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 247 | (a) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming) |
| 248 | (b) MCCB FP 40 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 01 No (outgoing) |
| 249 | (c) MCB TPN 20 Amps rating, C Curve, 415 V with rupturing capacity 10 KA - 01 No (outgoing) |
| 250 | (d) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing) |
| 251 | (e) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No |
| 252 | (f) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 01 No |
| 253 | (g) Fully automatic Motor Starter (Star-Delta) suitable for 25 HP submersible Pump set, 3 Phase - 01 No |
| 254 | (h) Single phase preventer, over load relays of suitable rating - 01 No |
| 255 | (j) Voltmeter 0-500 V digital type with selector switch - 1 No |
| 256 | (k) Indicator lamp LED type - 3 Nos (R, Y & B) |
| 257 | (l) Digital type ampere meter with suitable selector switch incl suitable resin cast CTs of 100/5 A - 01 No |
| 258 | Supply, install, testing and commissioning in repleacement of LT Feeder pillar Box, AC, 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 100A electricalgrade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed:-Note:- 1. Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires2. Panel board shall be manufactured from CPRI approved manufacturers only.3. Platform for panel should be 1.5 feet above average ground level.4. Connecting of existing UG cable to panel board as per site requirement. |
| 259 | (a) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming) |
| 260 | (b) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 01 No (outgoing) |
| 261 | (c) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing) |
| 262 | (d) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No |
| 263 | (e) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 01 No |
| 264 | (f) Fully automatic Motor Starter (Star-Delta) suitable for 35 HP submersible Pump set, 3 Phase - 01 No |
| 265 | (g) Single phase preventer, over load relays of suitable rating - 01 No |
| 266 | (h) Voltmeter 0-500 V digital type with selector switch - 1 No |
| 267 | (j) Indicator lamp LED type - 3 Nos (R, Y & B) |
| 268 | (k) Digital type ampere meter with suitable selector switch incl suitable resin cast CTs of 100/5 A - 01 No |
| 269 | Supply, install, testing and commissioning in repleacement of LT Feeder pillar Box, AC, 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 100A electricalgrade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed:-Note:- 1. Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires2. Panel board shall be manufactured from CPRI approved manufacturers only.3. Platform for panel should be 1.5 feet above average ground level.4. Connecting of existing UG cable to panel board as per site requirement. |
| 270 | (a) MCCB FP 125 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming) |
| 271 | (b) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 01 No (outgoing) |
| 272 | (c) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing) |
| 273 | (d) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No |
| 274 | (e) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 01 No |
| 275 | (f) Fully automatic Motor Starter (Star-Delta) suitable for 60 HP centrifugal Pump set, 3 Phase - 01 No |
| 276 | (g) Single phase preventer, over load relays of suitable rating - 01 No |
| 277 | (h) Voltmeter 0-500 V digital type with selector switch - 1 No |
| 278 | (j) Indicator lamp LED type - 3 Nos (R, Y & B) |
| 279 | (k) Digital type ampere meter with suitable selector switch incl suitable resin cast CTs of 120/5 A - 01 No |
| 280 | M & L for painting with approved colour to existing MS/GI pipe (raising main delivery over flow and wash out) of size 80/100/150/200mm diawith two coat of synthetic enamelled paint over a coat of red oxide primer including scrapping out old paint all as specified and directed. Note:- All T & P, 30 mtr staging mtrl and men power risk shall contractor responsibility. |
| 281 | Taking down steel water tubing galvanised, medium grade with all fittings and fixed complete to walls, or in floors,in old/new situationfor bore of pipefollowingsizes: - |
| 282 | (a) 15 mm dia |
| 283 | (b) 20 mm dia |
| 284 | (c) 25 mm dia |
| 285 | (d) 40 mm dia |
| 286 | (e) 50 mm dia |
| 287 | (f) 80 mm dia |
| 288 | (g) 100 mm dia |
| 289 | S & F steel water tubing galvanised, medium grade with all fittings and fixed complete to walls, or in floors,in old/new situation for bore of pipefollowingsizes: - |
| 290 | (a) 15 mm dia |
| 291 | (b) 20 mm dia |
| 292 | (c) 25 mm dia |
| 293 | (d) 50 mm dia |
| 294 | S & F steel water tubing galvanised, medium grade with all fittings and laid in trenchin old/new situation for bore of pipefollowingsizes: - |
| 295 | (a) 15 mm dia |
| 296 | (b) 20 mm dia |
| 297 | (c) 25 mm dia |
| 298 | (d) 40 mm dia |
| 299 | (e) 50 mm dia |
| 300 | (f) 80 mm dia |
| 301 | (g) 100 mm dia |
| 302 | Supply and laying well burnt sub class B bricks, old size bricks, laid flat dry, in trenches with width of the bricks layed to the axis of cable for cable protection complete all as specified and directed |
| 303 | Supply and spreads river sand for cable cushing in trenches all as specified in clause 19.75 of SSR Part 1 |
| 304 | Schedule of credit amount of Rs 174220.00 to be deducted during AOC |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail