| 1 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft loose soil complete all as specified and as directed for foundation of stay etc. |
| 2 | Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm. |
| 3 | Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed. |
| 4 | Supply and laying DWC high density polyethelene pipes having dia 63/50 mm, inner dia having corrugation on theouter wall and plain surfaces on the inner wall conforming to IS-14930 (Part-I & II) for protection of under ground cable laid along pole/along wall/ in PCC/GL Roof and including all fittings as required at site complete all as specified and directed. |
| 5 | Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 Sqmm 4 core complete all as specified |
| 6 | Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 16 Sqmm 4 core complete all as specified |
| 7 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 32x6 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed. |
| 8 | S&F in replacement of 40 mm bore GItubinglight grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as |
| 9 | S&F in replacmentLED street light 70 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed. |
| 10 | M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installationand including glands and with 4 terminals for terminating oneincoming and outgoingUG cable of size 10/16 sqmm 3.5/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and boltsand all specifiedand directed. |
| 11 | S & F in replacement pole mounted enclouser made of UV stabilized,FR grade special moulding compound having facility duriation base switching ON / OFF of capacity 5 KW, Threephase, with suitable size of FI clamps 02 Nos with the following accessories and all as directed.(i) MCCB 4 pole, 40 amp, 25 KA breaking capacity - 1 No (incoming)(ii) Power Contactor 3 pole, AC, 25 Amp, 50 Hz - 01 No.(iii) Timer switch light sensing type with outer sensor having current capacity 16 A & Contral from 1 lux to 100 K lux, 230 volts, 50 Hz - 01 No.(iv) Indication lamp (R, Y, B), LED type with toggle switches-01 set(v) Multi function meter with display parameters for voltage, ampere, PF etc - 01 No.Note :- All type of spares such as glands, lugs, nuts, bolts etc necessary excavation and earth work, PCC work and making good disturbed surfaces shall deemed to be included in thequoted unit rate. |
| 12 | S&F of cable PVC insulated and PVC sheathed three core 1.5 sqmm copper conductor multistranded complete all as specified and directed. |
| 13 | S&F GI breaket with 40 mm dia medium grade GI pipe 1.5 meter length for fixing of street light complete all as specified and directed. |