| Sl. No. | Item Description |
| 1 | Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 2 | Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 3 | Demolition ofreinforced Concrete of any description and in any position not otherwise specifically provided for(reinforcement cut as required to facilitate demolition) complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 4 | Demolition ofreinforced Concrete of any description and in any position not otherwise specifically provided for(reinforcement cut as required to facilitate demolition) complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 5 | M&L for Reinforced cement concrete (nominal mix) Type B1 (1:2:4) (using 20 mm graded stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 6 | M&L for Reinforced cement concrete (nominal mix) Type B1 (1:2:4) (using 20mm graded stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 7 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 8 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for fair finished surface of concrete complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 9 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 10 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 11 | All as per BOQ Serial item No 10 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 12 | All as per BOQ Serial item No 10 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 13 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 14 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 15 | M&L for brick work with sub class \"B\" bricks straight or curved on plan to any radius in half brick thickwallingbuiltin cement mortar (1:4) complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 16 | M&L for brick work with sub class \"B\" bricks straight or curved on plan to any radius in half brick thickwallingbuiltin cement mortar (1:4) complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 17 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 18 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 19 | M&L for 5mm thick plastering as inceiling surfaces in CM (1:3) surface finished even and fair complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 20 | M&L for 5mm thick plastering as inceiling surfaces in CM (1:3) surface finished even and fair complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 21 | M&L for 20mm thick (in two layer) plastering on fair face of Brick surface with CM (1:4) mixed with WPC finish surface even and smooth with out using extra cement complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 22 | M&L for 20mm thick (in two layer) plastering on fair face of Brick surface with CM (1:4) mixed with WPC finish surface even and smooth with out using extra cement complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 23 | M&L for 15mm thick cement plaster with CM (1:6) on other than fare face of brick wall finsh even and smooth without using extra cement complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 24 | M&L for 15mm thick cement plaster with CM (1:6) on other than fare face of brick wall finsh even and smooth without using extra cement complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 25 | Dismantling removing all unsound concrete, plastered material by chipping/chiseling gently at all effected and adjoining areas of concrete etc till sound surface is reached all various locations in building (upto 4 storied) subsequently cleaning the surfaces by hair brush and air blower and removing rubbish off the premises and disposing at the dumping site as approved by local authorities including hoisting assembling and fixing of double layer steel scaffolding to external perimeter of building complete all as specified and directed . |
| 26 | Dismantling removing all unsound concrete, plastered material by chipping/chiseling gently at all effected and adjoining areas of concrete etc till sound surface is reached all various locations in building (4 to 5 storied) subsequently cleaning the surfaces by hair brush and air blower and removing rubbish off the premises and disposing at the dumping site as approved by local authorities including hoisting assembling and fixing of double layer steel scaffolding to external perimeter of building complete all as specified and directed . |
| 27 | Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcement bars average 25mm(but not less than 15mm air gap) by manual methods (using wire brushing ,chiseling etc) and applying chloride free rust removing chemicalon rusting steel reinforcement bar and removing all rust from steel reinforcement barby emery paper and cleaning the area thoroughly by water and allow it to dry andtotally rust free of reinforcement bar all as complete as per manufacturer\"s instruction complete all as specified and as directed.Note: Working upto 4th storey height building is deemed to be included in quoted rate. |
| 28 | Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcement bars average 25mm(but not less than 15mm air gap) by manual methods (using wire brushing ,chiseling etc) and applying chloride free rust removing chemicalon rusting steel reinforcement bar and removing all rust from steel reinforcement barby emery paper and cleaning the area thoroughly by water and allow it to dry andtotally rust free of reinforcement bar all as complete as per manufacturer\"s instruction complete all as specified and as directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate.. |
| 29 | Preparation of existing reinforcement surface by brushand M&L for application of two component epoxy zincrich primeron existing reinforcement surface ofminimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2and maximum coverage area 5.00 Sqm per litre complete all as specified and as directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 30 | Preparation of existing reinforcement surface by brushand M&L for application of two component epoxy zincrich primeron existing reinforcement surface ofminimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2and maximum coverage area 5.00 Sqm per litre complete all as specified and as directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 31 | M&Lfor introduction of new reinforcement TMT bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 32 | M&Lfor introduction of new reinforcement TMT bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 33 | M&L formixingandplacementofmicro-concretecementbasedprepackedsingle component chloride free, sulphate free, non-shrink, free flow. elf compacting, ready to use after mixing water in specified proportion and in required thickness over and including a coat of epoxy resin bonding agent as per manufacture\"s instruction including necessary form work. Compressive strength (ASTM C 109, cm cube) of 50 MPa (Minimum) at 28 days including application curing compound concrete at various locations in Bldgs complete all as specified and as directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 34 | M&L formixingandplacementofmicro-concretecementbasedprepackedsingle component chloride free, sulphate free, non-shrink, free flow. elf compacting, ready to use after mixing water in specified proportion and in required thickness over a coat of epoxy resin bonding agent as per manufacture\"s instruction including necessary form work. Compressive strength (ASTM C 109, cm cube) of 50 MPa (Minimum) at 28 days including application curing compound concrete at various locations in Bldgs complete all as specified and as directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 35 | M&L for applying two component structural grade polymer modified reinforcement mortar upto a thickness of 30mm over a coat of epoxy resin bonding agent as per manufacture\"s specification. The cured mortar shall achieve a minimum compressive strength of 12N/mm2 in a day & 45 N/mm2 (Minimum) in 28 days with Flexural strength 8N/mm2 in 28 days Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. in addition to this percentage of water absorption should be 0.45 after 24 hours in immersion test at various locations in Bldgs complete all as specified and as directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 36 | M&L for applying at two component structural grade polymer modified reinforcement mortar upto a thickness of 30mm over a coat of epoxy resin bonding agent as per manufacture\"s specification. The cured mortar shall achieve a minimum compressive strength of 12N/mm2 in a day & 45 N/mm2 (Minimum) in 28 days with Flexural strength 8N/mm2 in 28 days Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. in addition to this percentage of water absorption should be 0.45 after 24 hours in immersion test at various locations in Bldgs complete all as specified and as directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 37 | M&L for application of high efficiency polymeric resin base filmforming curing agent/compoundover concretesurface withmaximum coverage area 5.00 Sqm per litre or as per manufacturers instruction complete all as specified and as directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 38 | M&L for application of high efficiency polymeric resin base filmforming curing agent/compoundover concretesurface withmaximum coverage area 5.00 Sqm per litre or as per manufacturers instruction complete all as specified and as directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 39 | M&L for applying a flexible expansion joint membrane of minimum 150mm wide and 1mm thick, expoband one (ExpobandH45) of FOSROC or equivalent over the prepared joint using a two part epoxy adhesive nitobond PC 40 of Fosroc or equivalent. The minimum tensile strength of the membrane should be more than 12 N/mm2 and elongation at break should be more than 400%. The installation of the membrane should be carried out as per manufactures specification complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 40 | M&L for applying a flexible expansion joint membrane of minimum 150mm wide and 1mm thick, expoband one (ExpobandH45) of FOSROC or equivalent over the prepared joint using a two part epoxy adhesive nitobond PC 40 of Fosroc or equivalent. The minimum tensile strength of the membrane should be more than 12 N/mm2 and elongation at break should be more than 400%. The installation of the membrane should be carried out as per manufactures specification complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 41 | S&Fshear connector of 8mm dia & requisite length on the surface to be repaired for bonding between old and new concrete as per the locations instructed by the Engr-in-Charge. The shear connectors shall be of L shape and welded with existing reinforcement at least 100mm in length @ 200mm c/c both horizontally and vertical followed by coat of epoxy Zinc primer as per the specification mentioned complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 42 | S&Fshear connector of 8mm dia & requisite length on the surface to be repaired for the bonding between old and new concrete as per the locations instructed by the Engr-in-Charge. The shear connectors shall be of L shape and welded with existing reinforcement at least 100mm in length @ 200mm c/c both horizontally and vertical followed by coat of epoxy Zinc primer as per the specification mentioned complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 43 | M & L for inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete for drilling suitable holes in RCC Slab/ wall/ column/ beams toa depthas directed for anchoring steel reinforcement bars including washing with water inserting lokfix \"E\" of Fosroc or equivalent in the holes at various location in Bldgs all as per manufactures specification complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 44 | M&L for inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete for drilling suitable holes in RCC Slab/ wall/ column/ beams toa depthas directed for anchoring steel reinforcement bars including washing with water inserting lokfix \"E\" of Fosroc or equivalent in the holes at various location in Bldgs all as per manufactures specification complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 45 | M&L for grouting in RCC walls and slabs by drilling holes @300 mm c/c upto half of the wall depth in zigzag manner using a drill machine and fixing a nozzle of 20mm dia, for injecting of epoxy grout till therefusal of injected groutmaterial (grouting operation pressure shall be in between 2 to 4Kg per sq cm) followed by cutting the exposed nozzle so as to make the wall/ slab free from the grouting pipe and to seal the gap with polymer modified mortar complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 46 | M&L for grouting in RCC walls and slabs by drilling holes @300 mm c/c upto half of the wall depth in zigzag manner using a drill machine and fixing a nozzle of 20mm dia, for injecting of epoxy grout till therefusal of injected groutmaterial (grouting operation pressure shall be in between 2 to 4Kg per sq cm) followed by cutting the exposed nozzle so as to make the wall/ slab free from the grouting pipe and to seal the gap with polymer modified mortar complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 47 | M&L for applying two coats of Anti carbonation coating (as per manufacturer\"s specification of approved brand) manually using brushes on the hardened concrete/plastered surfaces after cleaning the surface and removing all loose particles, deposits etc with and including one coat of primer complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 48 | M&L for applying Anti carbonation coating (as per manufacturer\"s specification of approved brand) manually using brushes on the hardened concrete/plastered surfaces after cleaning the surface and removing all loose particles, deposits etc complete with and including one coat of primer complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 49 | M&L for Carbon Fibre Wrapping, 450 GSM using High Performance high strength, carbon fibre system for structural strengthening to Reinforced Concrete members as per following steps:-(i)Surface Preparation : Proper surface preparation to be carried out including cleaning, removal of loose material, dust etc, executing required repairing like epoxy injection grouting, polymer modified mortar, epoxy touching Putty , rounding off edges of structural members to 25mm etc. (ii) Application : Prepared substrate shall be primed with epoxy primer supplied in pack size 4 Lit (Base-4.1 kg and Hardener -0.46 kg) at a coverage of 8-10 m2/litre/coat, allow the primer to cure for 24 hours followed by application of first coat of wrapping supplied in pack size 5kg ( Base - 3kg and hardener - 2kg) (having Tensile strength >30 MPa; Elongation > 2.1% ; Fibre strength > 4900 MPa ; Fibre E-Modulus >230 GPa & Flexural Modulus > 1700 MPa when tested as per ASTM D638 Type I and ASTM D 790 &Glass Transition Temperature > 50°C as per ASTM E 1356) to be carried out at a coverage of 3.5 to 4 m2/lit/Coat at around 250 microns WFT. (iii) cutting of Wrapping (available in standard roll width of 500 mm and roll length of 50 mtr & 100 mtr) in required size and wrap over wet saturant keeping minimum 150 mm overlap, rolling the same using hard roller to impragnent saturant and again applying second coat of saturant using suitable bush or roller etc, completing as per specification and as directed. Note:-Wrapping fabric used shall exhibit the following properties - fiber density of 1.8 g/cc, dry fibre thickness 0.40mm and shall have tensile strength > 4900 MPa ; tensile modulus > 230 GPa and ultimate elongation of 2.1%.The adhesion of the entire system (FRP Sheet, Saturant and primer combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D 4541 complete as per specification and as directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 50 | M&L for Carbon Fibre Wrapping, 450 GSM using High Performance high strength, carbon fibre system for structural strengthening to Reinforced Concrete members as per following steps:-(i)Surface Preparation : Proper surface preparation to be carried out including cleaning, removal of loose material, dust etc, executing required repairing like epoxy injection grouting, polymer modified mortar, epoxy touching Putty , rounding off edges of structural members to 25mm etc. (ii) Application : Prepared substrate shall be primed with epoxy primer supplied in pack size 4 Lit (Base-4.1 kg and Hardener -0.46 kg) at a coverage of 8-10 m2/litre/coat, allow the primer to cure for 24 hours followed by application of first coat of wrapping supplied in pack size 5kg ( Base - 3kg and hardener - 2kg) (having Tensile strength >30 MPa; Elongation > 2.1% ; Fibre strength > 4900 MPa ; Fibre E-Modulus >230 GPa & Flexural Modulus > 1700 MPa when tested as per ASTM D638 Type I and ASTM D 790 &Glass Transition Temperature > 50°C as per ASTM E 1356) to be carried out at a coverage of 3.5 to 4 m2/lit/Coat at around 250 microns WFT. (iii) cutting of Wrapping (available in standard roll width of 500 mm and roll length of 50 mtr & 100 mtr) in required size and wrap over wet saturant keeping minimum 150 mm overlap, rolling the same using hard roller to impragnent saturant and again applying second coat of saturant using suitable bush or roller etc, completing as per specification and as directed. Note:-Wrapping fabric used shall exhibit the following properties - fiber density of 1.8 g/cc, dry fibre thickness 0.40mm and shall have tensile strength > 4900 MPa ; tensile modulus > 230 GPa and ultimate elongation of 2.1%.The adhesion of the entire system (FRP Sheet, Saturant and primer combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D 4541 complete as per specification and as directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 51 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified & as directed. |
| 52 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 53 | Taking down chowkhats or frame with shutter (without taking off shutters from the frame) exc 1.5 sqmn.exe 4 sqm each complete all as specified and directed. |
| 54 | Taking down rusted steel windows/ventilators of any description and size including shutters complete all as specified and as directed |
| 55 | S&F 2nd Hardwood plain solid straight chowkhats, wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 56 | M&L for 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with both facecovered with decorative face veneer with lipping/frame to match complete all as specified and directed. |
| 57 | S&F Factory made single extruded WPC (Wood polymer composite) solid door Frames of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), mimimum compressive strength of 58 N/Sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. |
| 58 | S&F Factory made single extruded WPC(Wood polymer composite) solid flush door shutter of 30mm size comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimumdensity of 650 Kg/cum, screw withdrawal strength of 1800 N(Face) & 900 N (Edge), mimimum compressive strength of 50 N/Sqmm, modulas of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of termite/borer proof , water/moisture proof & fire retardant & fixing with SS butt hinges of required size with necessary full body threaded star headed counter sunk SS screws complete all as specified and directed. |
| 59 | S&FAluminium anodised (powder coated minimum 50 micron thickness) 3 track sliding window frame with shutters with (2 nos glazed and 1 wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. with glazing and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers including deco aluminium grill size complete all as specified and directed with the following section of frame and shutter:- (A) Sections for shutter :- (i) \"Vertical\" section 38 x 20 x 1.5 mm thick. (ii) \"Interlock\" section 38 x 20x 1.50 mm (iii) \"Top/ Bottom\" section 41 x 20 x 1.50 mm thick.(B) Section for frame :- (i) Top & Sides 91.00 x 29.70 x 1.50 mm thick. (ii) Bottom 91.00 x 29.70 x 1.50 mm thick |
| 60 | S&F Anodised powder coated aluminium (minimum thickness of powder coating 50 micron)frame for doors, windows, ventilators or aluminium frame for partition works etc with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 61 | S&F 12 mm thick prelaminated particle boards interior grade, prelaminated both side with decorative choice lamination, fixed with necessary clips and other like to aluminium frame work, as in doors, windows, partition etc complete all as specified and as directed. |
| 62 | S&F Anodised aluminium powder coated door, windows, ventilators shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 63 | S&F 6.5 mm thick glass ordinary quality, frosted on one side fixed to aluminium frame workexc 0.5 Sq. m in each pane complete all as specified & as directed. |
| 64 | S&F 5.0 mm thick glass ordinary quality, frosted on one side fixed to aluminium frame work n. exc 0.5 Sq. m in each pane complete all as specified & as directed. |
| 65 | S&Faluminium 4 levers Mortice lock, vertical type, size 100 mm complete all as specified and directed. |
| 66 | S&F Stainless steel handles 150mm long, bright polished complete all as specified and directed. |
| 67 | S&F 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy complete all as specified and directed. |
| 68 | S&F 150mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloycomplete all as specified and directed. |
| 69 | S&F Aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, complete all as specified and directed. |
| 70 | S&F Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, complete all as specified and directed. |
| 71 | S&F Bearing hinges 100mm, cast brass, with Stainless steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed. |
| 72 | S&F Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of appreature 1.40 mm and fixed with stainless wire staples complete all as specified and directed. |
| 73 | S&F in repairs aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 74 | S&F floor door stopper overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 75 | Dismantling floor, earth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 76 | M&L for Anti-skid joint free ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.06sqm but n.exceeding 0.11 sqm in toilet/bath floor etc.set and jointed with adesive and pointed in epoxy grout with spacers complete all as specified & as directed.Note: Screed bed shall be measured and paid separately |
| 77 | M&L for glazed ceramic (coloured) tiles of size (450x350x6-7)mm thick as in vertical surface/dado set and jointed in adesive and pointed in white or coloured cement to match complete all as specified and directed. |
| 78 | M&L forAnti-skid joint free ceramic coloured tiles exc 0.18 sqm but n. exc 0.38 sqm 7 to 8 mm, in floors etc. set and jointed in neat cement slurry over and including a bedding layer of scread bed 15 mm thick in CM (1:6) and pointed in white/colour cement to match complete all as specified and directed. |
| 79 | M&L for screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed. |
| 80 | M&L for bedding layer of mortar 10 mm thick in CM (1:3) for laying wall/dado finishes complete all as specified and directed. |
| 81 | Demolition of cement concrete above ground floor n.exe 15cm thickness(below or above ground level) complete all as specified and directed. |
| 82 | M&L for 25mm thick cement concrete typeB-0, (1:2:4) using 12.5mm graded stone aggregate complete all as specified and directed. |
| 83 | M&L for two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete all as specified and directed.Note:(i) The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency).(ii)Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm.( Fosroc/Elantas beck/Kunal conchem) (iii)Make : SIKA/FOSROC/Hindcon or equivalent make as approved by GE. |
| 84 | M&L for bore packing of all the Spouts to be done with grouting admixture mixes with Cement Concrete / Mortar @225 ml per bag of Cement complete all as specified and directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate |
| 85 | M&L for bore packing of all the Spouts to be done with grouting admixture mixes with Cement Concrete / Mortar @225 ml per bag of Cement complete all as specified and directed.Note: Working upto 5 to 8 storey bldg is deemed to be included in quoted rate |
| 86 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 87 | Taking up or down 15mm bore steel water tubingand connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate |
| 88 | Taking up or down 20mm bore steel water tubingand connections,including cleaning for removal to store (GI Pipe) complete all as specified and as directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 89 | Taking up or down 25mm bore steel water tubingand connections,including cleaning for removal to store (GI Pipe) complete all as specified and as directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate |
| 90 | Taking up or down 40mm or 50mm bore steel water tubingand connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate |
| 91 | Dismantling of 100mm cast iron or reinforced concrete drain pipes, jointed in cement mortarandtakingout of trenches, if required complete all as specified and directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate |
| 92 | Dismantling of 100mm cast iron or reinforced concrete drain pipes, jointed in cement mortarandtakingout of trenches, if required complete all as specified and directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 93 | S&F CPVC pipes 15 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. complete all as specified and directed. |
| 94 | S&F 20 mm bore (Outer dia) CPVC pipes ofSDR 11and plain CPVC SDR 11 fittingfixed on wall or floor (concealed), ceiling or laying in floors complete all as directed. |
| 95 | S&F in 25 mm bore (Outer dia) CPVC pipes ofSDR 13.5 and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as specified and directed. |
| 96 | S&F 50 mm bore (Outer dia) UPVC pipes ofSCH-40 and plain UPVC SDR 11 fittingfixed on wall or floor, ceiling or laying in floors complete all as specified and directed. |
| 97 | S&F 110mm dia PVC (SWR) pipes single socketed inany length withrubber ring joints fixed to walls complete all as specified and directed. NOTE: Working upto 4 storey bldg is deemed to be included in quoted rate |
| 98 | S&F 110mm dia PVC (SWR) pipes single socketed inany length withrubber ring joints fixed to walls complete all as specified and directed. NOTE: Working upto 5 to 8 storey bldg is deemed to be included in quoted rate. |
| 99 | S&F 20 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and directed. |
| 100 | S&F 25 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and directed. |
| 101 | S&F 20mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed. |
| 102 | S&F 25mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed. |
| 103 | S&F 50 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and directed. |
| 104 | S&F 50 mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed. |
| 105 | S&F PVC (SWR)bends 110mm dia complete all as specified and directed. |
| 106 | S&F PVC (SWR) junction single, (Single T) equal or unequal 110 mm dia complete all as specified and directed. |
| 107 | S&F PVC (SWR) junction double, (Double T) equal or unequal 110 mm dia complete all as specified and directed. |
| 108 | S&F in repairs vitreous china squatting pan “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed. |
| 109 | S&Fin repairs vitreous China wash down water closet pan (padestal pattern) incl PVC seat cover (excluding fixing bolts, flushing cistern and flush pipe) , including connection to drain ( or outgoing pipe) and to flushing pipe etc. complete all as specified and directed. |
| 110 | S&F in repairs vitreous china wash hand basin, white, flat back, size (550mm x 400mm), exc chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm diacomplete all as specified and directed. |
| 111 | S&F in repair Brass chromium plated bottle trap for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed. |
| 112 | S&F in repairs 15mm bore CP angular valve fancy type,with crutch handle, screwed for iron pipe or for brass ferrule and fixed of following size complete all as specified and directed. |
| 113 | S&F in repairs 15 mm bore CP Bib taps, fancy typewith crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 114 | S&F in repairs 15 mm bore CP Bib taps (Two-in-one), fancy type,with crutch handle,screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 115 | S&F in repairs 15 mm Dia CP stop cock (concealed type) ,with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 116 | S&F in repairs 15 mm bore, CP pillar taps,with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure complete all as specified and directed. |
| 117 | S&F in repairs25 mm bore brass gun metal gate valve ,with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 118 | S&F in repairs 15 mm bore brass CP mixer, for mixing Hot and Cold water screwed down for iron pipe, complete all as specified and directed. |
| 119 | S&F in repairs CP Health faucet with all necessary fittings complete all as specified and directed.Make : Prayag/Cera/Jaquar or equivalent make as approved by GE. |
| 120 | S&F in repairs 600 mmPVC connection pipe 15 mm size with PTMT nut of following length complete all as specified and directed . |
| 121 | S&Fin repairs 110/125 mm floor trap fixed in floor with grating incl jointing with solvent (1:2:4) cement concrete,complete all as specified and directed. |
| 122 | S&F (600 mm x 900 x 6 mm) bevelled edge mirror of selected quality glass, mounted on 6mm thick| AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass| screws and cup washers comlete all as specified and directed. Make: Prayag Catpart No BLM-01 F or equivelant make as approved by GE |
| 123 | S&F in repairs brass CP Shower roses with or without swivel joints, 125mm size, includingfixing to steel pipes or unioncomplete all as specified and directed. |
| 124 | S&F CP Soap dish, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 125 | S&F in repairs brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flangescomplete all as specfied and directed. |
| 126 | S&F in repairs PVC valveless, syphonic action type, low level, flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity with flush pipe (Long bend) 32mm dia complete all as specified & directed. |
| 127 | S&F Louvers type ventilator assembled partially with PVC exhaust fan of 200mm sweep and partially fixed with frosted glass of area n.exc 0.5 sqm includingall necessaryfittings complete all asspecified and directed. |
| 128 | Dismantling of old unserviceable water tank, removing from site, S&F rotational moulded polythene water storage tank, 1000 litre capacity, ISI marked (cylindrical, vertical, double layered with closed top) hoisted and fixed in position with and including PVC float valve 20mm bore weight not less than 210gms. complete all as specified and directed. |
| 129 | All as per BOQ Serial item No 128 above but capacity 2000 litre complete all as specified and directed. |
| 130 | Taking out/Stripping of old Roof treatment membranes/Tar felt incl layer ofcement mortar of any type carefully from roof surfaces (without damaging roof ) and incl preparation of old roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust & receive new treatment complete all as specified and directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 131 | Taking out/Stripping of old Roof treatment membranes/Tar felt incl layer ofcement mortar of any type carefully from roof surfaces (without damaging roof ) and incl preparation of old roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust & receive new treatment complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 132 | M&L for waterproofing treatment to sound, moisture free concrete surface using Liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., and application ofWater dispersible epoxy primer followed by two coats of continuous, seamless,water and vapour proof membrane for concrete, coverage @ 2.0 kg/m2 to achieve 1.5 mm WFT in two coats followed by laying of separation layer of 120 gsm non-woven geotextile layer before carry out protection screed etc. including all tools and tackles as per manufacturer’s specification. Continuous, seamless,water and vapour proof membrane for concrete cured material shall be having crack bridging of 2 mm, Elongation (ASTMD 412) – >600 %, Tensile Strength (ASTM D412) –2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, 85% Solid Content, Tear Resistance (ASTM D624) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 60, Water vapour transmission- 0.6 g/m2/hr, Water Permeability @ 5 Bar (BS EN 12390)-Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C, Viscosity-60p, Specific Gravity-1.5. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation, etc. complete all as specified and directed.Note:- (i) Cost of 120 gsm non-woven geotextile and 75mm Screed concrete Shall be paid separately. (ii)Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 133 | M&L for waterproofing treatment to sound, moisture free concrete surface using Liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., and application ofWater dispersible epoxy primer followed by two coats of continuous, seamless,water and vapour proof membrane for concrete, coverage @ 2.0 kg/m2 to achieve 1.5 mm WFT in two coats followed by laying of separation layer of 120 gsm non-woven geotextile layer before carry out protection screed etc. including all tools and tackles as per manufacturer’s specification. Continuous, seamless,water and vapour proof membrane for concrete cured material shall be having crack bridging of 2 mm, Elongation (ASTMD 412) – >600 %, Tensile Strength (ASTM D412) –2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, 85% Solid Content, Tear Resistance (ASTM D624) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 60, Water vapour transmission- 0.6 g/m2/hr, Water Permeability @ 5 Bar (BS EN 12390)-Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C, Viscosity-60p, Specific Gravity-1.5. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation, etc. complete as all as specified and directed. Note:- (i) Cost of 120 gsm non-woven geotextile and 75mm Screed concrete Shall be paid separately. (ii) Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 134 | Supply & Laying Geotextiles of 120 GSM over the water proofing coating to avoid damage during screed casting complete all as specified and directed.Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 135 | Supply & Laying Geotextiles of 120 GSM over the water proofing coating to avoid damage during screed casting complete all as specified and directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 136 | M&L for laying of maximum 75 mm thick (at RW outlet) protective screed over the waterproof coating at proportion of (1:2:4) admixed with suitable integral waterproofing compound conforming IS 2645:2003 @ 200ml per bag of cement and reinforced with PP fibres with proper slope towards RW pipes. Green stage saw cutting on the screed will be done in panels (3m X 3m) with a groove size of (10mm X 15mm) complete as per specification and as directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 137 | M&L for laying of maximum 75 mm thick (at RW outlet) protective screed over the waterproof coating at proportion of (1:2:4) admixed with suitable integral waterproofing compound conforming IS 2645:2003 @ 200ml per bag of cement and reinforced with PP fibres with proper slope towards RW pipes. Green stage saw cutting on the screed will be done in panels (3m X 3m) with a groove size of 10mm X 15mm complete as per specification and as directed.Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 138 | Dismantling of old Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 139 | S&F Pre painted galvalume aluminium zinc coating GI based corugated steel sheet 0.50mm thick Hi-Rib colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 140 | S&Fmild steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Confirming to IS-1161-1979, Gde-E-250 quality-Acomplete all as specified and directed. |
| 141 | S&F mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes of Fe 410-W (Gde-E250) quality-A complete all as specified and directed. |
| 142 | S&F mild steel Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 143 | Complete removal of existing treatmentby using electric sander machine or steel wire brushing to remove all dust and loose scale etc of wall surfaces complete all as specified & directed. Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 144 | Complete removal of existing treatmentby using electric sander machine or steel wire brushing to remove all dust and loose scale etc of wall surfaces complete all as specified & directed. Note: Working upto 5 to 8 storey bldg is deemed to be included in quoted rate. |
| 145 | M&L for 3mm thick wall care putty on wall including rubbing with sand paper to achieve a smooth surface & sharp straight edges etc. complete all as specified & as directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 146 | Preparation of newly plastered wall surface and M&L for applying two coats of oil emulsion distemper over and including a coat of primer on complete all as specified and directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 147 | Preparation old decorated walls & M&L for applying two coats of acrylic oil bound distemperover and including a coat of 1mm thick wall care putty complete all as specified and directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 148 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including 2mm thick wall care putty and a priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 149 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including 2mm thick wall care putty and a priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. Note: Working upto 5 to 8 storey bldg is deemed to be included in quoted rate. |
| 150 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including 1mm thick wall care putty and a priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed. Note: Working upto 4 storied bldg is deemed to be included in quoted rate. |
| 151 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including 1mm thick wall care putty and a priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed. Note: Working upto 5 to 8 storied bldg is deemed to be included in quoted rate. |
| 152 | Preparation of new decorated Ceiling surface & M&L for applyingtwo coats of acrylic oil emulsion distemper complete all as specified and directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 153 | Preparation of old decorated Ceiling & M&L for applyingone coats of acrylic oil emulsion distemper complete all as specified and directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 154 | Preparing of new steel surfaces & M&L for applying two coats of synthetic enamelled paint overa coat of red oxide primer complete all as specified and as directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 155 | Preparing of old steel surfaces & M& L for one Coats of Synthetic Enamel Paint over one coat of primer to steel and iron surfaces of any description,not otherwise described including preparation of old surface complete all as specified and directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 156 | M&L for applying two coats of synthetic enamelled paint on New wooden surface exc 10cm width or girth including preparation of surface complete all as specified and as directed. Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 157 | M&L for one coat of synthetic enamel paint, areaexc.10cm width or girthover old painted wooden surfacesincluding preparationof surface complete in all respect as specified and directed.Note: Working upto 4 storey bldg is deemed to be included in quoted rate. |
| 158 | Taking down old rusted u/s steel collapsible gates or rolling shutters any size including taking out holdfasts/anchorages and other fixtures complete all as specified complete all as specified and directed. |
| 159 | S&F in repairs 1.25 mm steel rolling shutters without ball bearing,as specified including top cover,anchoring,hasp and staple and one shop coat of primer erected in position as indicated,complte: but gear operated type with chain wheel and hand chain complete all as specified and directed. |
| 160 | M&L for60 mm thick machine pressed precast interlocking paver block of M-35 Grade any shape and size with grey cement and pigment confirming to IS 15658-2006 complete all as specified and directed. |
| 161 | M& L for hard core of gauge in exc. 63mm broken stone boulders deposited and spred and leveled in layers in.exc. 15mm thick complete all as specified and directed. |
| 162 | M&L for sand filling under floor or in floor or paving, laid in including watering and consolidation true surface for laying paver block complete all as specified and directed. |
| 163 | M&L for 150mm thick PCC (1:2:4) Type B 2(using 40 mm graded stone aggregate) as in sub base 150mm thick complete all as specified and directed. |
| 164 | Supply only Intregal water proofing compound complete all as specified and directed. |
| 165 | M&L for Cement concrete as in saucer drains Type B1 (1:2:4) (using 20 mm graded stone aggregates) slope maintained as per site requirement complete in all respect as specified and directed |
| 166 | M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggregate as in plinth protection / paving, surface finished even & smooth using extra cement complete as specified and directed. |
| 167 | Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power) alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc complete all as specified and directed. |
| 168 | M&L for point wiring complete as specified with 1100 V grade with 1.5 Sq mm single core PVC insulated unsheathedFRLSHcable, copper conductor multistrandedpassing through including concealedPVC conduit not less than 20 mm dia with concealed modularboxsuitable for logic modular switches, sockets etc with logic modular white plates, sorroundingsof suitable sizeas required atsitewith PVC insulated FRLSHunsheathedstranded copper conductor of size 1.5 sq mmas earth wireconnected to common earthdully complete all as specified and directed for the following:- Note: - (i) Rate quoted shall include for cost of making MS box and conduit concealed in wall including cutting and sinking of boxes and making good tothe walls (ii) Provision of cover plate andblank plates as per site requirement (No extra payment will be made for the same) |
| 169 | One light point / one fan point controlled by one, one way swtich. |
| 170 | One 5 Amp switch socket on the same board. |
| 171 | One 5 Amp switch socket on independent board. |
| 172 | All as per BOQ Serial item No 168.01 above but size of cable 4.0sq mm with earth wire of 4.0sq mm complete all as specified and directed. |
| 173 | S&F switch modular type, single pole, one way, 5/6 Amp, one module, completes all as specified and directed. Make-Legrand cat no-675501 /Havells/anchor wood or equivalent make as approved by GE |
| 174 | S&F switch modular type, single pole, one way, and 15/16 Amps, one module complete all as specified and directed. Make-Legrand cat no-675501 /Havells/anchor wood or equivalent make as approved by GE |
| 175 | S&F socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, two module, modular type completes all as specified and directed. Make-Legrand cat no-675550 /Havells/anchor wood or equivalent make as approved by GE. |
| 176 | S&F socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin 5/6 Amp, modular type completes all as specified and directed. Make-Legrand cat no-675555 /Havells/anchor wood or equivalent make as approved by GE |
| 177 | S&F in replacment ceiling rose of size (65 x 50) mm surface bakelite 240 Voltsthree terminal complete all as specified and directed. |
| 178 | S&F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 179 | S&F LED lights fitting 1x 10 W, 220V Mirror Lightwith driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 180 | Taking down geyser, any type and Refixing complete all as specified and directed. |
| 181 | S&F single pole and Neutral Enclosure with a twopin and earth plug and socket complete with and including one single pole MCB 20 Amps LED 20W complete all as specified and directed. |
| 182 | M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 4 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 4 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed.Note:- (i)Threeruns of cablesdrawn in conduit will be measured as one length of sub main. (ii)PVC conduit and its accessories is deem to be included in this item rates.(iii) Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |