| 1 | Excavating in trenches, n.exc 1.5m wide and n exc 1.5 in depth; for foundation getting out hard/dense of soil or (Demolition of PCC block/stone masonry below ground level) all as directed. |
| 2 | Material and labour for providing plain cement concrete1:3:6 type C2, using( 40mm graded stone aggregate )as in foundation filling and massconcrete for manhole&Septic tankall as specified and as directed. |
| 3 | M&L for Precast cement concrete block Type C1(1:3:6)(using 20 mm graded aggregate) masonry with solid solid blocks exc 10cm width and setting in mortar(1:4) complete. |
| 4 | M&L 10mm thick rendering plaster onfair face of brick-work or concrete surface incl finish the surface even and smooth withoutusing extra cement in CM 1:6 complete all as specified and as directed . |
| 5 | M & L for PCC (1:3:6) type C-1 (using20 mm graded stone aggregate) as in lintels upto 1.5m clear spam, cills,steps; sesmic and other similar bands, plinth courses, kneeler, apex stones, bed plates, water trougs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 6 | M&L For extra for forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement including form moulds mitred/stopped ends etc. complete all as specified and directed. |
| 7 | Dismantling wrought iron or mild steel work of any description not otherwise provided for grill,rail etc |
| 8 | M&L for MSFramed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 completeall as directed. |
| 9 | M/L preparing new surface of steel and appyling two coats of synthetic enamel paint over a coat of primer red oxide complete all as specified and as directed. |
| 10 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed |
| 11 | M&L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) setin cement mortar (1:6) work for landings, cover slabs, manholes, chajjas, water troughs, manger shleves and similar articles with plain faces complete all as specified and as directed |
| 12 | S & F TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 13 | Demolition of cement concrete (unreinforced ) in ground floor and pavings not exc.15 cm thickness (below or above ground level) and removing debris off the site complete all as spcified and as directed. |
| 14 | M&L 75mm thick Plain Cement Concretetype C-1, 1:3:6 (20mm graded stone aggregate)as in floors, sub base, plinth protection etc. finished even & fair without using extra cement complete as specified and as directed. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layersnot exc 25 cm complete as in hard /dense soil all as spd and directed. |
| 16 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as directed. |
| 17 | Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out in soft /loose soil etc complete. |
| 18 | M&L for 75 mm thick Cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate asin sub base concrete complete all as specified and as directed |
| 19 | M&L for Screed bed 15 mm thick in cement mortar (1:6) below paver stone complete all as specified and as directed |
| 20 | M&L for 600x600x50 mm size granite stone slabs with fair finished surface laid flat in grid pattern with 50 mm gap allaround the stone slabs and set on cement mortarcomplete all as specified and as directed |
| 21 | Demolition of stone slabs, floor hearth or wall tilinglaid bedded and pointed in any mortar (but not backing) complete all as specified and directed. |
| 22 | Demolition of cement concrete (unreinforced ) of any description and in any postion not otherwise spcifically provided etc (below or above ground level)as in roof pad /floors etc and removing debris off the site complete all as spcified and as directed. |
| 23 | Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 24 | Taking down chowkats or frames including shutters (without taking off shutters from the frames)exceeding 1.50 Sqm and not exceeding 4 Sqm each,complete all as specified and directed. |
| 25 | Material and labour for UPVC door with shutters .The construction profile shall be overall frame sectional size 60x 58mm with wall thickness 2.70+/- 0.2mm extruded sections.The corners shall be plastic welded.The hinge side vertical outer frame shall be reiforced with galvanised steel profileof wall using 8mm dia 80mm long MS screws minimum 3 Nos on each side.The glazing shall be fixed to door frame with UPVC standared beading s of sectional size 24.05x16mm & 2mm thick.The bottom portion of door shutter shall be provided with UPVC board 5mm thick & 1Mtr in height andthe balance shall be glazed excluding the shutter frame area.The shutter shall be fixed to frame using 3Nos of 3D hinges.The door shutter shall beprovided with 5mm thick sheet glass & 5mm UPVC board with EPDM rubber gasket,multi point lockingwith powder coated handles and two numbers powder coated MS tower bolts complete all as specified and as directed.The cost of glass, sheet etc shall be deemed with the quoted rate. |
| 26 | Supply and fixing factory made UPVC white colour Two track two panels sliding window, frame 67x50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.comprising of UPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality,incl Glazing shall be provided with 5mm thick Plain / frosted glassfixed with appropriate size beading as per manufacurer\"s specificationscomplete all as specified and directed. |
| 27 | S & F blinds of approved make roller type,Zebra pattern using polyester/PVC/vinly of approved colour/shade and pattern including operating arrangements such as chord/thread,counter weight,connecting chain etc and necessary fittings complete all as specified and as directed. |
| 28 | M&L for precast solid block exceeding 10 cms in width 1:3:6 type C1 (using 20mm graded aggregate) and set in cement mortar 1:6 all as specified and as directed |
| 29 | M&L for preparation of newplastered surfaces of walls applying two coats of distemper, oil emulsion including alkali resistant primer over 1mm thick wall care putty complete all as specified and directed. |
| 30 | M&L forGranite 18-20mm(any patern) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) 15 mm thickness of mortar including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 31 | M&L Providing25mm thick cement concrete type B0, 1:2:4 using 12.5 mm graded stone aggregate as in floors for levelling course including finish the surface even and fair to receive the floor finish completeall as directed. |
| 32 | M&L for vitrified ceramictiles 8-10mm thick dark colour (Square/rectangular) area of each tile n exc 0.36 Sqmas in floor etc set and jointed in neat cement slurry and pointing in white or coloured cement to match the colour of tiles over and including 20 mm thick screed bed in CM 1:6 complete all as directed and specified. |
| 33 | All as per item No 32, but in skirting over 10mm thick backing coat in CM 1:3. |
| 34 | Supply and fix of Armstrong Mineral Fibre Suspended Ceiling System with Classic Litre Tegular Edge Tiles of 12mm thick and Armstrong Prelude 24mm face exposed grid. The tiles shall have pin hole visual with Humidity Resistance (RH) of 99%, 0.55 as per ASTM C423 standard, CAC of 36db, Light Reflectance ≥87%, Thermal Conductivity k = 0.052 - 0.057 W/mK, Clolour Global White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84with 16mmTegular edge. The tile shall be laid on Armstrong Prelude 32 with 24 mm wide T - section flanges colour global white (matching to tile colour) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm. The grid system is to comprise main runner spaced at 1200mm securely fixed to the structural soffit using Armstrong suspension system (specifications above) at 1200mm maximum. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum etc complete all as specified and as directed. |
| 35 | Supply and fix18mm thick High Density High Moisture Resistant (HDHMR) Board or HDWR board,both side laminated of approved colour as in shutters, back board, vertical support and horizontal shelves of kitchen/bedroom cupboards fixed with screw to timber framed work etc., including dismantling of existing any type of board and complete all as specified and as directed.Note: All exposed edges/surfaces to be finished with samelaminated sheet to match with the other surfaces and nothing will be paid extra.Make : Century/Action Tesa or equivalent. |
| 36 | Supply and fix Stainless steel soft close hinge with 35mm cup dia, full overlay, 110 degree opening suitable for 18mm thick shutters complete all as specified and as directed.MAKE: EBCO/ GODREJ / KAFF / HETTICH |
| 37 | Supply and fixGun metal handle ofsize150mm for kitchen/bedroom cupboards fixed with screws complete all as specified and directed.MAKE: EBCO/ GODREJ / KAFF / HETTICH |
| 38 | Supply and fixlock for cupboard/wardrobe with two keys and key hole cover (silver,painted finish) fixed with screws complete all as specified and directed.MAKE: EBCO/ GODREJ / KAFF / HETTICH |
| 39 | M & L forcomplete removal of existing treatment fromold plastered surface of walls and applying two coats of distemper oil emulsion with 1 mm thick putty over a coat of alkali resistant primercomplete all as per manufacturer\"s instruction and as directed.. |
| 40 | Taking down point wiring (light, fan, socket or power) complete , including fixture and fittings such as switches, ceiling roses, sockets, light fitting, bell etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 41 | M&L for concealed point wiring with 1.5 Sq mm,FRLS, PVC insulated, sheathed cable, single core, copper conductor cable of 1100 Volt grade, multi stranded drawn through rigid non metalic medium grade PVC conduit concealed in wall with suitable modular metal boxes flush to wall,controlled by one switch with and includingcontinuous 1.5 Sqmm PVC insulated single core copper conductor cable as earth continuity conductor connected to commonearth dolly etc. complete all as specified and directed. Note :(i)The cost of making good the disturbed surfaces is deemed to be included in the quoted rate.(ii) The cost of cutting chases is deemed to be included in the unit quoted rate. |
| 42 | a) One light/fan/call bell point controlled by one switch |
| 43 | b) One 5 amps 3 Pin socket outlet on independent board |
| 44 | All as per Item No-41 above but with FRLS PVC insulatedcopper conductor cable of size 2.5 Sqmm for independent complete all as specified and directed. |
| 45 | S&F Modular type socket out let 2/3 pin, 6/16 Amps, 2 module all as specified and as directed. |
| 46 | S&F Modular type Socket outlet 6 Amps 2/3 Pin, 2 module complete all as specified and directed. |
| 47 | S&F Modular type switch single pole 16 Amps one way, 1 module all as specified and as directed |
| 48 | S&F Modular type switch single pole 6 Amps, 1 module, one way all as specified and as directed. |
| 49 | S&F modular white cover plate with frame, 3 module complete all as specified and directed. |
| 50 | S&F modular white cover plate with frame, 4 module complete all as specified and directed. |
| 51 | S&F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and directed. |
| 52 | Supply and fixing LED lights fitting 1x 20W, 220V, AC , (4 ft.) High performanceelectronic driver operating temperature 10 C to 35 °C operating voltage range 140 V -270 V , Average life 50000 hours and LED lamp including High efficiency long life LED with lumen efficacy of 140 Im/watts and ABS end caps tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Make Havells cat part No LUMILINEPLUSPROBS20WLED865SPCSSIND OUGG |
| 53 | S&F 2x4.0 sq.mm + 1x4.0 sq.mm earth wire wiring for circuit/submain wiring alongwith earth wire with following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required as required and including PVC Conduit pipe 20 mm dia with all fittings all as specified and as directed.Note : Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps cills, sunshades, shelves, lintels etc; and cutting chases for concealed water tubing or consealed conduit wiring, etc, and making good, cutting not exc 10cm girth. |
| 54 | S & F SPN DB, 8 Way,Metal double door type 240 volts fitted with 200 Amps rated busbar and blanking plates, neutral link and making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed. |
| 55 | S&F SP 6 to 32 AMP rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) and current carriying capacity in the MCB DB complete with connection testing and commissioning all as specified and dircted. |
| 56 | S&F SPN 32 AMP rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) and current carriying capacity in the MCB DB complete with connection testing and commissioning all as specified and dircted. |