| 1 | Excavation work by mechanical means (Hydraulic excavator)/ manualmeans in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost ofcentering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and acces |
| 5 | Centering and shuttering including strutting, propping etc. and removalof form for Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 6 | Steel reinforcement for R.C.C. work including straightening,cutting,bending, placing in position and binding all complete above plinth level. |
| 7 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 7.5 average compressive strength in super structure above plinth level up to floor V level in :Cement mortar 1:6 (1 cement : 6 Coarse sand |
| 8 | Half brick masonry with non modular fly ash bricks of class designation 7.50, conformingio IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 9 | Providing and fixing 16 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing of edges to give high gloss finish etc. completeat all levels.Granite stone slab of colour Lakha red.Area of slab over 0.50 sqm |
| 10 | Providing and fixing aluminium extruded section body tubular typeuniversal hydraulic door closer (having brand logo with ISi, IS : 3564,embossed on the body, door weight upto 36 kg to 80 kg and door widthrom 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. |
| 11 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm |
| 12 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm |
| 13 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 14 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm |
| 15 | Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessary screwsetc. complete.Twin rubber stopper |
| 16 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 17 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 18 | Providing and fixing fly proof stainless steel grade 304 wire gauge, towindows and clerestory windows using wire gauge with average widthof aperture 1.4 mm in both directions with wire of dia. 0.50 mm al complete.With 12 mm mild steel U beading |
| 19 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of sizeSize of Tile 600 x 600 mm |
| 20 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 21 | Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cementmortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 22 | Deduct for not grouting the joints with white cement and matchingpigment in the items of fixing of vitrified tiles. |
| 23 | Grouting the joints of flooring tiles having joints of 3 mm width, usingepoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm. |
| 24 | Grouting the joints of flooring tiles having joints of 3 mm width, usingepoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600 x 1200 mm |
| 25 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 26 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 27 | Distempering with oil bound washable distemper of make \"\" Asian UNO\"\"to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer of make \"\"Asian paint Smart Care \"\" |
| 28 | Finishing walls with ready mixed Premium acrylic emulsion paintof make Asian Apcolite premiumas per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer of make Asiansmartcare applied @ 0.90 litre/10 sqm. (Store & Purchase) |
| 29 | Painting with synthetic enamel paint of make \"\"Asian Apcolite\"\" to give an even shade :Two or more coats on new work . |
| 30 | Painting with synthetic enamel paint of make \"\"Asian Apcolite\"\" to give an even shade :Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture Agency shall bring container and make signatureof EE(Civil) before start of the work and keep the signed container till the final bill is passed) |
| 31 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 32 | Applying priming coats with water thinnable primer of \"\"Asian make Smartcare\"\" . on wall surface |
| 33 | Finishing walls with water proofing cement paint of required shade :Old work (one or more coats @ 2.20 kg/10 sqm) complete. |
| 34 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 35 | Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 36 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge.In cement mortar cum |
| 37 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead :Of area 3 sq. metres and below |
| 38 | Taking out doors, windows and clerestory window shutters (steel orwood) including stacking within 50 metres lead of area 3.00 sqm and below |
| 39 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 40 | Dismantling wooden boardings in lining of walls and partitions,excluding supporting members but including stacking within 50metres lead :Thickness above 25 mm up to 40 mm |
| 41 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping ground or as approved by Engineer-in-charge for all leads including all lifts involved |
| 42 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :Powder coated aluminium (minimumthickness of powder coating 50 micron) For fixed portion |
| 43 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :Powder coated aluminium (minimumthickness of powder coating 50 micron For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 44 | Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item): With float glass / black panes of 5 mm thickness (weight notless than 12.50 kg/sqm) |
| 45 | Dismantling & refixingthe existing Aluminum door/ window and partitions shutter after repairing the same and fittings as requiredetc complete item as directed by the EIC. |
| 46 | Dismantling, cutting and refixing the existing wooden sinngle/ doule feaf doorshutter in good condition incuding fixing necessary screws as required as per direction of Engineer-in-charge. |
| 47 | Providing and fixing 8 mm thick plain multipurpose cement board fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 48 | P/F 75mm aluminumstar locking handleof TPI make or equivalent for aluminum sliding window and cup-board shutter of approved quality as directed by the EIC. |
| 49 | Providing and fixing hard plastic roller of TPI make or equivalent for sliding Aluminium window/cup-board shutter including all fittings of approved quality as directed by the EIC. |
| 50 | Providing and fixing of 6 mm thick polycarbonate sheet of approved shed on chajja of window and doors etc complete including all hooks and hardwares and silicon for jointing as required as per the direction of Engineeer- Incharge |
| 51 | Removing the existingPVC sheet flooring including cleaning the surface as good in condition anddisposal of dismantled material, for all leads including all lifts involved. as per direction of Engineer-in-charge. |
| 52 | Providing and fixingroller blind (Black out) without head rail ofVISTA make model SERENE (OPAQUE)without head rail ofapproved colour as per the direction of the EIC. |
| 53 | Dismantling and re-fixing the particle board in alauminum partition wall afterr cutting and finishing including necessaryscrews as required at site as directed by the EIC. |
| 54 | Providing and fixing designer film of required approved pattern of any colour and superior quality above glass complete item as directed by the EIC. |