Sl. No.
Item Description
1
Point wiring for independent plug in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories Make:-Wires:-Polycab/Vishal cables/Finolex cables and wires ,Switches:-Anchaor Panasonic/Cona/GM Pipe:-HMS :As aaproved sample in UMC
2
Providing servicing of 1/1.5/2/3 TR capacity split/window air conditioning unit complete with all necessary material. Job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit and submitting report to Engineer incharge
3
Providing Brazing pipes and checking leakages in the split/ window unit duly with dry nitrogen pressure in an approved manner.
4
Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 1.5TR window/split air conditioning
5
Providing flushing out cooling coil and condensor coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure in an approved manner
6
Providing replacement of unserviceable starting relay
7
Providing replacement of unserviceable starting capacitor
8
Providing replacement of unserviceable fan motor capacitor
9
Supplying and installing of new fan motor for condensor
10
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position Make:-Voltas /Bule star /Daiken
11
Providing vaccumising the air conditioner system and charging with R-22 refrigerant for air conditioning
12
Providing replacement of blower of indoor unit for air conditioning unit. Please Enable Macros to View BoQ information