| 1 | Excavating over areas, n exc 1.50 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Description same all as per item No. 01 here in above but depth exc 1.50 mtr and not exc 3.00 mtr complete all as specified and directed. |
| 3 | Description same all as per item No. 01 here in above but depth exc 3.00 mtr and not exc 4.50 mtr complete all as specified and directed. |
| 4 | Description same all as per item No. 01 here in above but depth exc 4.50 mtr and not exc 6.00 mtr complete all as specified and directed. |
| 5 | Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed. |
| 6 | Use and waste of timbering as plankingand strutting forexcavations over areas n exc 1.50 m deep in soil, including wales,struts, open polingboards, use and wasteof raking shores etc. as may benecessary and fixing and removal complete all as specified and directed. |
| 7 | Description same all as per item No. 06 here in above but exc 1.50 m deep and n exc 3.00 m deep complete all as specified and directed. |
| 8 | Description same all as per item No. 06 here in above but exc 3.00 m deep and n exc 5.00 m deep complete all as specified and directed. |
| 9 | M&L for Cement concrete 1:4:8 Type D-2 using 40 mm graded stone aggrgate in foundations, filling and mass concrete complete all as specified and directed. |
| 10 | M&L for Reinforced Cement concrete (Design Mix) M-25 as infoundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed pilesand mass concrete complete all as specified and directed. |
| 11 | M&L for Reinforced Cement concrete (Design Mix) M-25 as in Walls, retaining walls,basement walls, ballast walls and the like, any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 12 | M&L for Reinforced Cement concrete (Design Mix) M-25 as inColumns, pillars, piers, posts and struts complete all as specified and directed. |
| 13 | M&L for Reinforced Cement concrete (Design Mix) M-25 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 14 | Use and waste Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and directed. |
| 15 | M&L for flat/tapered surfaces of Formwork to faces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc vertical or to batter for rough finished surfaces of concrete complete all as specified and directed. |
| 16 | Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal for rough finished surfaces of concrete complete all as specified and directed. |
| 17 | Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete complete all as specified and directed. |
| 18 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm depth complete all as specified and directed. |
| 19 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 20 | Removing excavated materialexc. 250m but n exc 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 21 | M&L Mild steelTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally forooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 22 | Description same all as per item No. 21 here in above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed . |
| 23 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 24 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick/ concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 26 | M&L for Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and directed. |
| 27 | M&L for preparation of newly plastered surfaces of wall and appling two coats of Cement based paint over a coat of alkali resistant primer complete all as specified and directed. |
| 28 | S&F for mild steel work with angle iron, flat iron, channel etc. as in post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (For securing wire mesh etc) including all necessary drilling, bolting or riveting etc, and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 29 | M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide Zinc chrome primer complete all as specified and directed. |
| 30 | M&L for Cutting holes of superficial area exc 100 sq cm but n exc 250 sq cm into or through cement concrete slabs, chajjas, etc. reinforced or otherwisecomplete all as specified and directed. |
| 31 | M&L for Cutting holes of superficial area n exc 150 sq cm into or throughbrick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concreteand making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. |
| 32 | M&L for providing cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in cills, steps, seismic andothersimilar bands, plinth courses, string courses, lacing courses, parapets andrailings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs , water troughs and the like including weathering,slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 33 | Treating ends of posts, backs of chowkats, etc., area tarred exc 0.1 sq. m but n exc 0.5 sqm each all as specified and directed. |
| 34 | S&F concertina coil 600 mm dia (stretched position) hot dip galvanised including \"U\" and \"C\" clip, having 50 Nos of spirals in 8 mtr stretch length and composed of reinforced punched razor ribbon sides of cold rolled low carbon steel fixing of the \"Y\" of trapezoidal shaped angle iron brackets placed at 2.5 to 3 meter apart complete all as specified, shown in drawings and as directed. The barbs should have 180 degree straightness, razor edge cut with following specifications:-(i) Concertina coil confirming to IS-513, IS-4454 (Part-1) and IS-12753 (ii) Clips-18 SWG GI(iii) Wire dia-2.60 mm (iv) Razor blade tape length-20 mm (minimum) (v) Razor blade tape width- 14 mm (minimum)vi) Razor blade thickness- 0.50 mm (vii) Clips per round of circle-05 Nos(viii) Zinc coating- 230 to 240 GSM heavy coating hot dip(ix) Tensile strength-1620 N/ Sqmm (minimum)Note : (a) Horizontal razor wire and angle iron supports will be measured and paid separately under relevant items of Sch \"A\"/ BOQ. (b) Measurement will be made for stretched length. |
| 35 | S&F hot dip galvanised razor wire fencing with 2.60 mm dia centre core wire having barbs of length 20mm (minimum), width 14mm (minimum) and thickness 50mm razor strip on swan neck angle iron and fixing with antirust clamps on angle iron post including all fittings like fastener clips, steel leg rings etc as shown in drawing complete all as specified and directed. The barbs should have 180 degree straightness, razor edge cut with following specifications.(i) Razor wire confirming to IS-513, IS 4454 Part-I and IS-12753 (ii) Zink coating- 230 to 240 GSM heavy coating hot dip.(iii) Tensile strength- 1620 N/Sqmm (minimum)Note:- Each line of wire will be measured for payment purpose. |
| 36 | Taking down cement or cement lime plaster any description fromwalls/ceiling etc including racking out joints, hacking for key & scrubbing down with water including removing of debries out side of MOD landcomplete all as specified and directed. |
| 37 | Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facing, dressed stone work and precast concrete articles etc. complete all as specified and directed. |
| 38 | M&L forbrickwork with sub class- B old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 39 | M&L forbrickwork with sub class- B old size bricks (except bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. Note: bricks obtained from demolition shall be used. |
| 40 | Demolition of reinforced cement concrete (reinforcement cutas required to facilitate demolition) of any description and in anypositionnot otherwise specifically provided for complete all as specified and directed. |
| 41 | Dismantling floor, hearth or wall tilling including cement mortar bedding and rubbish off the premisescomplete all as specified and directed. |
| 42 | S&F heavy duty exterior finish designer pavement tiles, coloured, superior quality, 300x300x10mm thick as in floors/ pavement etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 43 | S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 44 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 45 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 46 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5mtr depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc and getting out complete all as specified and directed. |
| 47 | M&L for Sand cushioning using Ganga River sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable completed all as specified. ( Note: punned thickness shall be considered for payment) |
| 48 | M&L Burnt bricks, sub class\"B\" of designation 75, standard size laid in trenches as in protection of UG cables complete all as specified and directed. |
| 49 | M&Lfor replacement of LT UG cable10 Sqmm x 2 Core1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, lugs/ thimbles/ ferrules including connecting, testingcompleteall as specified and as directed. |
| 50 | Supply & fixing Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metre long) including drilling of necessary holes, & painting complete all as specified.Note : (i) Cost of painting & numbering on poles i.e. making five no. alternative white & black strips 30 cm height each (upto 1.50 metre height from top of PCC coping & numbering to the poles with synthetic enamel paint etc shall be deemed to be included in the rates of above items(ii) Earthwork , PCC foundation & coping shall be measured and paid separately under respective item of Schedule. |
| 51 | Material ans labour for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate for foundations of poles/stays complete including form work all as directed. |
| 52 | Material and labour for PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate for coping of poles and platform incl. necessary form work fair and finishing without using extra cement complete all as specified and directed. |
| 53 | S&F PVC insulated unarmoured ,PVC sheathed cable of size 1.5 Sqmm 3 core cut to pieces all as Specified and directed by Engr -in -charge.Make : Havells/Polycab/Finolex or equivalent makes. |
| 54 | S&F rigid PVC conduite \"medium grade\" of size 25 mm bore incl fittings, ISI marked,fixing with steel tubular pole for wiring connection from pole box to light fitting and supporting with 03 NosGI strip clamp , nut boltand complete all as specified and directed. |
| 55 | S&F in replacementGI pipe40/50 mm bore, light grade, 1.50 metres long,bent to shape required as in street light brackets, fixed to poles/ wallswith suitable size MS clamps, nuts & bolts complete all as specified and as directed. |
| 56 | S&F in replacement Pole box junction three phase of size 297x 250 x 130 mm, made of 2 mm MS sheet factory painted with synthetic enamelpaint, and inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fix on epoxy insulated support and MCB 6 Amp 10 kA 240 volt complete all as specified anddirected.Make : Hensel or equivalent makes as approved by GE |
| 57 | S&F in replacement ofHigh power LED Street light fitting90 watt5000 k, IP>66 , IK>07 grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed .Make: Philips : Cat No : BRP033 LED90 CW SLR GR PSU SPD or equivalent makes as approved by GE |
| 58 | M&L for earthing complete with Galvanized Steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to and including GI wire of 4 mm dia connected by means of GI bolts, nuts, and washers, protected by 15 mm bore GI light grade ISI marked pipe upto and including test points. Earthing plate shall be surrounded by alternate layers 15cm thickof charcoal or coke and common salt all around bottom and top, 20mm dia GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) including necessary form work, excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceed ing 50 M, pit cover 40 mm thick made with RCC (1:2:4) type B-1 (using 20mm graded crushed store aggrgate) including TMT reinforcement80 mm dia @ 75 mm C/C both way, MS handle of 12 mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as shown in electrical plate No-3 of SSR Part-I and all as directed. |
| 59 | Supply, installation, testing and commissioning of desert cooler electric driven (single phase) with kit fan moto 450mm sweep, made out of PGI sheet 1mm thick of size not less than 0.5 width and 0.7m height and storage tank of PGI sheet 1mm thick of size not less than 0.7m x 0.7m and height 0.2m, having approximate nominal air flow of 5000 cum per hour, alongwith provision of suitable accessories as required for successful working of cooler complete all as specified and directed. |
| 60 | M&L for iron stand rolled mild steel section confirming to Gde Fe-410-0 as in desert cooler stand required size, fixed with angle cleat and conneccting plates, etc complete all as directed. |
| 61 | M&L for concealed point wiring complete with PVC insulatedd unsheathed, 1100 volts grade cable 2.5 sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit meddium grade ISI marked including all conduit accessories for concealed wiring for with and including cutting chases and making good of disturbedd surfaces & applying finishes for one 5 Amp socket point controlled by one, one way switch, including con-cealed pressed steel terminal box of required size not less than 1.6mm thick factory madde duly painted inside and outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, socket, fan regulator etc including 2.5 Sqmm FR type PVC insulated unsheathed cable multi-stranded copper. |
| 62 | S&F for Switch piano, 5Amp flush type single pole one way 230 volts complete all as specified and directed. |
| 63 | S&F for Socket outlet 5 pin, 5Amp flush type complete all as specified and directed. |
| 64 | S&F for Tube medium grade galvanised with all fittings and fixed complete 15mm dia to wall and ceiling or laid in floors complete all as specified and directed. |
| 65 | S&F for stop valve, cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both end for iron pipe or for unions and fixed complete all as specified and directed. |
| 66 | S&F for ball valve high pressure of PTMT 15 mm dia with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 67 | Schedule of Credit (MINUS) Rs. 17,271.50 B/F from Serial Page No. ____[Note : Detailsof items for schedule of credit is given on Srl Page No. ___] This amount shall be automatically deducted to arrive at tendered sum |