| 1 | Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for laying pipe line etc, complete all as specified and as directed by Engineer-In-Charge.Note :-The quoted rate shall be deemed to have included necessary \"trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete complete including necessary all tools, tackles etc. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge. |
| 3 | Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge. |
| 4 | Replacement old un-serviceable Sluice Valve with new Sluice Valve, cast iron, Class PN 1.6, size 150mm bore pipe, flanged type, conforming to IS: 14846-2000, ISI marked with stainless steel spindle, brass nuts and iron wheel head including jointing material such as rubber fibre board packing ring and nuts, bolts and washers of suitable size for vertical or horizintal fittings, complete all as specified and as directed by Engineer-In-Charge. |
| 5 | Replacement old un-serviceable Sluice Valve with new Sluice Valve, cast iron, Class PN 1.6, size 100mm bore pipe, flanged type, conforming to IS: 14846-2000, ISI marked with stainless steel spindle, brass nuts and iron wheel head including jointing material such as rubber fibre board packing ring and nuts, bolts and washers of suitable size for vertical or horizintal fittings, complete all as specified and as directed by Engineer-In-Charge. |
| 6 | Replacement old un-serviceable Sluice Valve with new Sluice Valve, cast iron, Class PN 1.6, size 80mm bore pipe, flanged type, conforming to IS: 14846-2000, ISI marked with stainless steel spindle, brass nuts and iron wheel head including jointing material such as rubber fibre board packing ring and nuts, bolts and washers of suitable size for vertical or horizintal fittings, complete all as specified and as directed by Engineer-In-Charge. |
| 7 | S&F Tubes, \"medium grade\" galvanised, 15mm bore, ISI markedincluding all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls,including taking up or down galvanised steel tubing and connections, any type, including jointing materials and cleaning for re-fixing or removal to store complete all as specified and as directed by Engineer-In-Charge. |
| 8 | S&F Tubes, \"medium grade\" galvanised, 20mm bore, ISI markedincluding all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls,including taking up or down galvanised steel tubing and connections, any type, including jointing materials and cleaning for re-fixing or removal to store complete all as specified and as directed by Engineer-In-Charge. |
| 9 | S&F Tubes, \"medium grade\" galvanised, 25mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls,including taking up or down galvanised steel tubing and connections, any type, including jointing materials and cleaning for re-fixing or removal to store complete all as specified and as directed by Engineer-In-Charge. |
| 10 | S&F Tubes, \"medium grade\" galvanised, 40mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches,including taking up or down galvanised steel tubing and connections, any type, including jointing materials and cleaning for re-fixing or removal to store complete all as specified and as directed by Engineer-In-Charge. |
| 11 | S&F Tubes, \"medium grade\" galvanised, 50mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches,including taking up or down galvanised steel tubing and connections, any type, including jointing materials and cleaning for re-fixing or removal to store complete all as specified and as directed by Engineer-In-Charge. |
| 12 | Replacement old un-serviceable gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 15mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. |
| 13 | Replacement old un-serviceable gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. |
| 14 | Replacement old un-serviceable gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 25mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. |
| 15 | Replacement old un-serviceable gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 40mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. |
| 16 | Replacement old un-serviceable gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 50mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. |
| 17 | Run lead joint, suitable for cast iron pipes and fittings of 100mm bore including jointing materials such as lead, spun and spun yarn, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. |
| 18 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead of galvanised iron strip of size 25x4 mm connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and20mm bore light gradeGI pipewith funnel and wire mesh for watering including necessaryexcavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR( Part-I) of 2009 and testing on completion including taking down old earthing, complete all as specified and as directed by Engineer-In-Charge.(Note : Earth result should not exceed 2 Ohms) |
| 19 | Repairs of valve pit of size 900x900x900mm (internal dimensions) including brick masonry, rendering in 15mm thick cement mortar 1:4 on internal and external surfaces and white wahsing with two coats of lime wash including painting with two coats of black colour synthetic enamel paint to mild steel surfaces of angle iron framed work mild steel sheet with mild steel hinges, handles and suitable locking arrangements, fastening arrangements, nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge. |
| 20 | Repairs of valve pit of size 1200x1200x1200mm (internal dimensions) including brick masonry, rendering in 15mm thick cement mortar 1:4 on internal and external surfaces and white wahsing with two coats of lime wash including painting with two coats of black colour synthetic enamel paint to mild steel surfaces of angle iron framed work mild steel sheet with mild steel hinges, handles and suitable locking arrangements, fastening arrangements, nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge. |
| 21 | Construction of brick masonry valve pit of size 900x900x900mm (internal dimensions of chamber) including plain cement concrete, M-7.5 (1:4:8), type-D2 (using 40mm graded crushed stone aggregates) 100mm thick, as in sub baseand PCC M-15 (1:2:4), type-B2 (using 40mm graded crushed stone aggregates) 100mm thick, as in flooring, brick work masonry, 23cm thick in cement mortar 1:4, rendering 15mm thick in cement mortar 1:4 on internal and external surfaces with two coat of lime wash, mild steel framed work as in valve pit covers with angle iron frame 50x50x6mm and including mild steel sheet cover 3.15mm thick complete, drilling/ welding for fixing of steel sheeting with mild steel hinges, handles and suitable locking arrangements, fastening arrangements for fixing, nuts, bolts and washers including painting with two coats of synthetic enamel paint over a coat of red oxide primer, including excavation in any type of soil, returning filling in external areas and removal the surplus soil to a distance of not exceeding 50mtrs, complete all as specified and as directed by Engineer-In-Charge. |
| 22 | Cleaning of overhead water tank, capacity 50,000 Gallons, height/ staging 18.85mtrs, by scraping with mild steel wire brush and removing all the silt, dirt, algae, sludge etc from the surfaces of walls and floor including removal the same to a distance not less than 50mtrs, washing the cleaned surface with bleaching powder solution thoroughly and applying two coats of lime wash on internal surfaces of reservoir, also applying two coats of cement paint of external surfaces of tank with staging after preparation of surfaces, and writing the particulars such as capacity of tank, date/ due date of tank cleaning in bold letters, on table size not less than 60cmx40cm, painted with black and white synthetic enamel paint on external surface, including painting with one coat black synthetic enamel paint to external surfaces of flow pipes with valves any type as connected with overhead water tank and making flow signs with white synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge. |
| 23 | Cleaning of overhead water tank, capacity 10,000 Gallons,by scraping with mild steel wire brush and removing all the silt, dirt, algae, sludge etc from the surfaces of walls and floor including removal the same to a distance not less than 50mtrs, washing the cleaned surface with bleaching powder solution thoroughly and applying two coats of lime wash on internal surfaces of reservoir, also applying two coats of cement paint of external surfaces of tank with staging after preparation of surfaces, and writing the particulars such as capacity of tank, date/ due date of tank cleaning in bold letters, on table size not less than 60cmx40cm, painted with black and white synthetic enamel paint on external surface, including painting with one coat black synthetic enamel paint to external surfaces of flow pipes with valves any type as connected with overhead water tank and making flow signs with white synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge. |
| 24 | Cleaning of UG Sump, 100000 Gln capacity by disconnecting all electric connections from LT panel, starter, removing pipe line from discharge side, taking out submersible/ centrifugal pump with motor along with column pipe by mechanical or manual method, scraping all mud, algae, silt, sludge and other dirts by mild steel wire brush floor including removal the same to a distance not less than 50mtrs and re-assembling/ lowering down submersible/ centrifugal pump with motor, column pipe and making all electric and water supply connection to the existing lines/ system, also applying two coats of cement paint of external surfaces of tank with staging after preparation of surfaces, including writing the particulars such as capacity of tank, date/ due date of tank cleaning in existing letter sizes, on table size not less than 60cmx40cm, painted with black and white synthetic enamel paint on external surface, complete all as specified and as directed by Engineer-In-Charge. Note :- Necessaryscaffolding and staging work, ladders etc alongwith Saftey Harness and other tools and plants required to complete the entire job shall be deemed to be included in the quoted rates of the item and nothing extra shall be paid extra on this account. |
| 25 | Supply only the chlorine test kit for the pump house to check the free chlorine level at source & user end at up to 2.0 PPM level complete all as specified and directed. |
| 26 | Testing & checking the Quality of water in following parameter need to dertermine as perIS: 10500-2012 As per IS: 10500-2012 :-(a)Microbial parameter of waterNote : The rates are includes (i)The testing of water is required to be carried out from Govt approved Lab and intimate portability for drinking purpose for the troops and families in Akhnoor mil stn.(ii)Collection of water from tubewell in sterilized bottle obtained from Govt Lab jointly and submit the sample on same to Lab as directed by Engr-in-Charge.(iii)Collection of water reports and submitted to office after testing all as directed by Engr-in-Charge. |
| 27 | Testing of chlorine jointly in presence of operator of borewell once in a day Morning / Evening before supply hrs to ensure free chlorination 2.0 PPM at source & including routine and periodical maintenance of chemical dozing pumps replacement of defective spare parts to keep them functional at serviceable condition and maintaining record duly signed by operator. Note:- 1.The cost of transportation daily to check tube well in Morning & Evening deemed to be includeed in unit rate of above item. 2.Spare parts required shall be measured and paid separately as supply only. 3.The record of free chlorine check to be put up daily to JE E/M / AGE E/M4.Contractor will be responsible for proper chlorination in all pump houses. In case chlorination is found NIL at any location during oversear the work by concerned JE E/M or Engr-in-Charge the recovery @ Rs 1000.00 will deducted per location, per day, per month from contractors RAR/ Final Bill. |
| 28 | M&L in replacement of rusted/unserviceable MS clamp of suitable size with nut, bolts & washers complete for hanging submersible pump set with column pipes in borewell any size/cap all as directed by Engr-in-charge. |
| 29 | M&L in replacement of rusted/unserviceable MS cap of suitable size as casing cover of borewell all as specified and directed by Engr-in-charge. |
| 30 | Replacement of old unserviceable/ damaged battery with new storage cell lead acid type 12 Volts, 150 AH including lead terminals and copper thimble for making necessary connections, complete all as specified and as directed by Engineer-In-Charge. |
| 31 | Supply only copper lead cable 1.50mtrs long, multi-stranded, with copper thimble for making necessary connections at both ends, suitable for 12/ 24 Volts battery including copper nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge. |
| 32 | Lifting up submersible pump set of any capacity alongwith MS/GI column pipe from bore well at different locations including submersible cable of any size by manual or mechanical means after disconnecting all electrical connections from LT panel or starter and transport to workshop for repair and workshop to site after repairing, complete all as specified and directed by Engineer-in-charge. Note : (i) Submersible cable, column pipes to be stacked at asuitable place at TW/pump house for inspection and cleaning properly, with anti sclant solution and painting with synthetic enameled paint.(ii) All T&P shall be arranged by the contractor.(iii) All items taken out from TW/Pump Houses shall be kept in well secured places and shall be the responsibility of the contractor till the machines are not made functional. |
| 33 | Lowering of submersible pump set of any capacity alongwith MS column pipe exc 50 mm dia but not exc 150 mm dia, making flanged joints, cable connections and providing binding dori for binding and packing the submersible cable, complete all as specified and as directed by Engineer-In-Charge |
| 34 | Dismantling of pump set for inspection and identification of serviceable and unserviceable partsfor repair and overhauling and reassembling after replacement of unserviceable parts complete upto 20 HP submersible pumping set all as specified and directed.Note:- (a) Rate quoted for the this item shall include labour charges for the refixing the serviceable parts and fixing of new parts. (b) Spare parts shall be measured and paid seprately under supply only item. |
| 35 | Replacement of stainless steel pump main shaft suitable for and upto 20 HP pump set all as per existing size and shape,complete all as specified and as directed. |
| 36 | Supply and fixing in replacement of GM bushes all as per existing size suitable for submersible pumping set of capacity 10000GPH / 12000 GPH, complete all as specified and as directed. |
| 37 | Supply and fixing in replacement of neck ring all as per existing size and shape suitable for submersible pumping set of capacity 10000GPH / 12000 GPH, complete all as specified and as directed. |
| 38 | Supply and fixing in replacement of GM impeller all as per existing shape and size suitable for submersible pumping set of capacity 10000GPH / 12000 GPH, complete all as specified and as directed. |
| 39 | Supply and fixing in replacement of studs 100mmx45mm of suitable size, suitable for submersible pumping set of capacity10000GPH / 12000 GPH, complete all as specified and as directed. |
| 40 | Supply and fixing in replacement of suction connecting piece CI all as per existing size and shape suitable for submersible pumping set of capacity 10000GPH / 12000 GPH, complete all as specified and as directed. |
| 41 | Supply and fixing in replacement of main pump shaft all as per existing shape and size suitable for submersible pumping set of capacity 10000GPH / 12000 GPH, complete all as specified and as directed. |
| 42 | Supply and fixing in replacement of motor pump coupling with key all as per existing size suitable for submersible pumping set of capacity 10000GPH / 12000 GPH, complete all as specified and as directed. |
| 43 | Supply only Submersible cable jointing kit for upto 35sqmm 3 core submersible cable, complete all as specified and as directed. |
| 44 | Supply only Rubber gasket with 8 Nos holes made out of 6mm thick superior quality neoprime sheet suitable for 100 mm bore, complete all as specified and as directed. |
| 45 | Supply and fixing in replacement of stainless steel sleeves suitable for bowl assy of capacity 10000GPH / 12000 GPH, complete all as specified and as directed. |
| 46 | Dismantling and re-assemble of submersible electric motor upto 20 HP, 3 phase 440 volts,taking out burnt material and rotor, cleaning and making it smooth for rewinding complete, complete all as specified and as directed.Note : The items required for repair & replacement will be measured as supply only against relevant item of sch A |
| 47 | Rewinding stator of upto 20 HP motor with existing size and gauge of PVC insulated water proof copper winding wire and insulation material complete all as specified and directed.Make of winding wire Finolex/CCI/KEN.Note : Contracter will giveWarranty of rewinded motor at least 6 month minimum. Contractor will send his rep to Pump House for attending complaint. The contracter will rectified bottlenecks with in 48 Hrs if fail for any reason,a fine of Rs 1000/-day will be imposed for non compliance, complete all as specified and as directed. |
| 48 | Supply and fixing in replacement of thrust bearing bronze all as per existing shape and size suitable for up to 20HP submersible pump, complete all as specified and as directed. |
| 49 | Supply and fixing in replacement of thrust plate all as per existing size and shape, complete all as specified and as directed. |
| 50 | Supply and fixing in replacement of housing bush Gun Metal all as per existing size upto 20 HP motor, complete all as specified and as directed. |
| 51 | Supply and fixing in replacement of rotor sleeve Gun Metal all as existing size and shape suitable for up to 20 HP submersible electric motor, complete all as specified and as directed. |
| 52 | Supply and fixing in replacement of rotor seal bush Gun Metal all as existing size and shape suitable up to 20 HP submersible electric motor, complete all as specified and as directed. |
| 53 | S&F in repair of a submersible pumpof cap to draw the water 10000/12000 glns proppel through submersible motor of cap 20HP deliver at a head of 110/125 meter with 10/12 staging, complete all as specified and as directed. |
| 54 | Supply and fixing in replacement of \"T\" bolts and nuts all as per exisitng size and shape suitable for submersible electric motor all as per exisitng size and shape, complete all as specified and as directed. |
| 55 | Repair of LT/Starter Panels (Guardian) etc. without using any accessories to make the pump sets operational, complete all as specified and as directed. |