| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | SCHEDULE A PART-I(A) BUILDING & STRUCTURE WORK (To be Quoted by contractor)Construction of \"STN GYMNASIUM BUILDING\" framed structure with permanent specification incl internal services complete all as specified and as shown on drawings.(i) Cost of pile cap including RCC, reinforcemenmt and formwork & its earthwork are included in the quoted amount of building. |
| 3 | Lumpsum price worked out by the tenderer for CAST-IN-SITU PILE WORK (Prepriced at SSR-2020) as listed in Schedule ‘A’ Part-I (B) |
| 4 | Lumpsum price worked out by the tenderer for SITE CLEARANCE & DEVELOPMENT as listed in Schedule ‘A’ Part-II |
| 5 | Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III |
| 6 | Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV |
| 7 | Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-V |
| 8 | Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI |
| 9 | Lumpsum price worked out by the tenderer for ROAD, PATH AND CULVERTS as listed in Schedule ‘A’ Part-VII |
| 10 | Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII |
| 11 | Lumpsum price worked out by the tenderer for AIR CONDITIONING as listed in Schedule ‘A’ Part-IX |
| 12 | SCHEDULE \"A\" SEC-X (MISCELLANEOUS ITEMS) NOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS \"RS 0.00\" UNDER COL. 5 SIGNIFIES THIS FACT ONLY. |
| 13 | Boring for bored cast in situ piles 450mm dia 10m in soil and getting out and disp[osal of spoil to a distance 50m using DMC method (Direct mud circulation) complete all as specified and as directed. |
| 14 | Boring for bored cast in situ piles 600mm dia 10m in soil and getting out and disp[osal of spoil to a distance 50m using DMC method (Direct mud circulation) complete all as specified and as directed. |
| 15 | S&F Wall mounted type fans of 400 mm sweep, 03 blades aerodynamically balanced with 60 degree oscillation, working Voltage range 230 V, having minimum air delivery 70 CMM with service value not less than 1.43 BEE, 5 star rated with brush less direct current motor(BLDC), the super efficient BLDC motor 50Hz and Noise level not more than 64 dB with 2 years warranty complete all as specified and directed. NOTE: - Contractor has to provide2 years warrantyfrom the date of installation. |
| 16 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW, complete of capacity 15 Ltrs, BEE 5 Star rated complete with allaccessories such as safety valve, thermostate, NRV, connection pieces for for hot and cold water complete and including all fixing accessories complete all as specified and directed by Ebgineer-in-Charge. NOTE: - Contractor has to provide2 years warrantyfrom the date of installation. |
| 17 | S & F Modular blanking plate modular type suitable for fixing in modular switch board,complete all as specified and as directed. |
| 18 | Supply and fix power unit suitable for upto2.0 ton Air Conditioner having push ON-OFF push button switch, motor starter type, single phase, 4 module with and including mudular metal flush box with cover plates complete all as specified and directed by Engr-in-charge. (For AC) |
| 19 | S & F Surge Protection Device (SPD) 4 module, 25 KA,3Ph+N Right, T1+T2, limp 12,5KA per pole, T2-60KA,completeand making connections by using necessary thimble/washersetc of copper/brass material complete all as specified and directed. (For Main Lighting & AC DB) |
| 20 | Supply, installation, testing and commissioning of Automatic Voltage Stabilizer, single-phase, 4 KVA rating (or higher as per site requirement) suitable for operation of 1.5 TR inverter type, 5-star rated split AC units, conforming to IS:9815 and IS:302 (Part 2/Sec 40). The stabilizer shall be copper-wound, microprocessor-based / servo-controlled, input range 170–270 V (wide-range model, 140–290 V where grid condition warrants), output 220–230 V ±2%, correction speed ≤10 V/sec, efficiency ≥95%, with high/low voltage cut-off, automatic restart, time delay relay (2–3 minutes), surge and spike suppression, digital display of input/output voltage, LED indicators for status. The stabilizer shall be housed in powder-coated CRCA steel enclosure, wall/floor mountable, complete with all internal wiring and connections, duly tested at factory and site. Item includes all accessories, installation materials, testing and demonstration at site. Warranty: minimum 2 years onsite support complete all as specified and as directed. |
| 21 | Supply, installation, testing and commissioning of Automatic Voltage Stabilizer, single-phase, 5 KVA rating (or higher as per site requirement) suitable for operation of 2.0 TR inverter type split/cassette type AC units, conforming to IS:9815 and IS:302 (Part 2/Sec 40). The stabilizer shall be copper-wound, microprocessor-based / servo-controlled, input range 170–270 V (wide-range model, 140–290 V where grid condition warrants), output 220–230 V ±2%, correction speed ≤10 V/sec, efficiency ≥95%, with high/low voltage cut-off, automatic restart, time delay relay (2–3 minutes), surge and spike suppression, digital display of input/output voltage, LED indicators for status. The stabilizer shall be housed in powder-coated CRCA steel enclosure, wall/floor mountable, complete with all internal wiring and connections, duly tested at factory and site. Item includes all accessories, installation materials, testing and demonstration at site. Warranty: minimum 2 years onsite support complete all as specified and as directed. |
| 22 | Providing, fabricating, supplying and fixing in position heavy-duty wall-mounted bracket suitable for outdoor condensing unit of split or cassette type air conditioners of capacity up to1.5 Tr - 2.0 TR, made out of structural mild steel angle or flat section of minimum 3 mm thickness, hot-dip galvanized after fabrication with zinc coating not less than 80 microns conforming to IS 4759 or alternatively powder-coated over zinc-rich primer providing minimum 500 hours neutral salt spray resistance as per ASTM B117. Bracket shall be of adequate size with minimum two load-bearing arms, cross-bracing to resist sway, and designed to carry at least three times the combined static and dynamic load of the outdoor unit. All nuts, bolts and washers shall be stainless-steel 304 or hot-dip galvanized high-tensile steel, and anchor bolts shall be stainless-steel or galvanized expansion type M10 / M12 (Hilti / Fischer / equivalent) with embedment not less than 75 mm in RCC wall. High-density neoprene antivibration pads of 10 mm thickness and hardness 60–70 ShA shall be placed below each outdoor-unit foot. Bracket shall be mounted with 5–10 mm outward slope for drainage, all cut edges sealed with zinc-rich paint, and no on-site welding after galvanizing shall be permitted. Installation shall include drilling, anchoring, hoisting, fixing, painting touch-ups, and making good of all disturbed surfaces complete in all respects as directed by Engineer-in-Charge. Note:- Measurement shall be per complete bracket assembly inclusive of all fasteners, pads, and accessories. |
| 23 | Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) andPP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 75 mm including all necessary cutting, jointing etc for tapping arrengement from existing line and all fittings including cutting/reducing/inserting suitable fittings for branch connection at the place of tapping of water connection all as specified and as directed by Engineer-in-Charge. |
| 24 | All as per item No. 21 here-in-before but 50 mm (2”) dia |
| 25 | All as per item No. 21 here-in-before but 25 mm (1”) dia |
| 26 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. |
| 27 | Supply and fix PPR Gate Valves (Brass Insert) of 75 mm bore complete all as specified and as directed. |
| 28 | Supply and fix PPR Gate Valves (Brass Insert) of 50 mm bore complete all as specified and as directed. |
| 29 | Supply and fix PPR Gate Valves (Brass Insert) of 25 mm bore complete all as specified and as directed. |
| 30 | M&L for reconstruction of brick masonry valve pitof size 90cm x 90 cm x 90cm (internal dimension) with one brick thick P.C.C 1:4:8 type D-2 (using 20mm graded crashed stone aggregate) as in foundation concrete incl PCC (1:3:6) type CI (using 20mm graded crashed stone aggregate) as in bedding and coping 10mm thick cement plaster inCement mortar (1:4) internally & externally upto 15 cm below ground level providing valve pit 50x50x6mm angle iron frame all round the fixed point by means of 4 Nos hold fast 150mm long made out of flat iron 40 x 6 mm embedded in PCC block (1:2:4) type B-I (using 20mm graded crashed stone aggregate) of size 230 x200 x100mm. incl provn of hing welded with angle iron frame and Mild Steel cover 3 mm thick, Mild steel handle of suitable and size welded with MildSteel cover & suitable locking arrangement & applying two coats of synthetic enamel paint over a coat of red-oxide primer incl necessary excavation work in soft/ loss soil complete all as specified & directed |
| 31 | M&L for PVC pole junction box of size 155X210X92 mm, IP 66/69 with 4 pole connectors, PVC cable Each gland (02 nos) Steel binding or holding kit, nut bolts etc suitable as street light control box complete all as directed . |
| 32 | Supply, install, testing and commissioning of main LT Panel board, TPN 415 volls, 50 HZ out door Each kiosk type of size 1.5mX0.6mX1 m mounted on MS angle 50X50 mm 6 mm thick framework factory made, double door dust, vermin and weather proof IP-65, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out suitable size with cable chamber for individual feeders for incomming and outgoing connentions, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current of 600 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCBs (intake point) will be carried out with TPN bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fused with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following incoming and outgoing feeders: |
| 33 | M&L for boring of holes horizontally under road, pavement, hard standing for inserting Cable protection pipe for passing cable under road/pavement/hard standing etc complete all as specified and directed |
| 34 | Supply and fix cable route indicator oval shaped of size 200x150x6mm thick made out of Cast Iron with letter embossed as \"HT UG Cable\" or \"LT UG Cable\" fixed to 25x25x6mm mild steel angle iron 450mm long embedded in PCC block of size 200x200x200mm in PCC 136 type C1 using 20mm graded stone aggregate and including painting two coats of synthetic enamel paint over a coat of redoxide zinc chrome premier on exposed steel surfaces all as specified and as directed |