| 1 | Demolition of Mud in roofs/chajja, any thickness including plastering and leeping,(whether full thickness removed etc complete all as specified. |
| 2 | Demolition Bricks (laid flat or on edge) or brick tiles in laid beddedin any mortar on floors, channels,kerbs, aprons, etc. (each layer) complete all as specified. |
| 3 | M&L for 40 mm thick PCC (1:2:4) type B-0 (using 12.50 mm graded stone aggregate) as in roof padding, sub base of floor copingcomplete all as specified and directed. |
| 4 | M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified.Notes : WPC shall be measured and paid seperately. |
| 5 | M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm followed by a tack coat @ 1.2 kg per sqm using 85/25 grade industrial hot blow bitumen over it laid with APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm as per manufacturer\"s instructions complete all as specified. |
| 6 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 7 | M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified and as directed. |
| 8 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4)for laying floor finishescomplete all as specified and as directed. |
| 9 | M&L for Cement concrete tiles 25cm x 25cm x 22mm thick, machinepressed; set jointed and pointed in neat cement slurry in floors, and cutand polished, set with grey cement and pigments complete all as specified. |
| 10 | Demolition of un-reinforced concrete on roofs, floors (other than ground floors), beams/ chajjas and similar suspended work complete all as specified and as directed. |
| 11 | M & L for cement concrete in Type B1 1:2:4 (20mm gradede aggregate) for coping in chajja, balcony, beam complete all as specified and as directed. |
| 12 | M&L for guniting work to RCC work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and S&F welded wire mesh fabric or wire net less than 95 X 95X 3 mm adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 40 mm and making the surface even including 15mm thick plastering in CM 1:4 on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to be carried at upto doublestorey building Note.- Where ever reinforcement required will be measured and paid seperatly etc complete all as specified. |
| 13 | Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified. |
| 14 | M&Lfor 5 mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling includingfinishingsurface even and smooth without using extra cement. |
| 15 | M&L for 10 mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls includingfinishingsurface even and smooth without using extra cement |
| 16 | M&L for 15 mm thick plaster in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified. |
| 17 | M&L for preparation ofnewly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified. |
| 18 | M&L for preparation ofnewly plastered or unplastered/undecorated surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified |
| 19 | M&L for preparation ofnewly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified |
| 20 | M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified and as directed. |
| 21 | M&L for providing 3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform all as specified and as directed. |
| 22 | S&F in repair false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid \"Armstrong\"white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old undervicable false ceillingcomplete all as per manufacturer’s instructions and as directed. |
| 23 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings/similar wpork etc. complete all as specified & directed. |
| 24 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified. |
| 25 | S&F for pre-painted Galvalume aluminium Zinc cooating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to valley gutter/ridge fixed with self tapping screws all as specified and directed. |
| 26 | Dismantling mild steel work of any description not otherwise provided for complete all as specified. |
| 27 | S&F framed work such as grills gratings, etc with ends of bar shouldered and/or revited or forged into spikes, framed guard bars, barred iron doors, ladders, framedbalusters, walk ways, railings framework of water tanka and similar works confirming to Fe 290 Gde E-165 complete all as specified |
| 28 | S&F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, without any attachment confirming to Fe 410-S complete all as specified. |
| 29 | S&F steel work as in tubular, rafters, purlins, posts and similar work(round/sqare/rectangular shape of pipes as approved by Engr-in-charge ) trusses of semi circle/ curved shape up to height 6 mtrincluding postspecial shaped washers etc complete incl necessary nut bolts wind ties and gusset plates etc using ERW or induction butt welded tubes conformining to IS 1161-1998 garde St-240 complete all as specified. |
| 30 | Taking up or down15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. |
| 31 | Taking up or down20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. |
| 32 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girthin brick wall etc complete all as specified. |
| 33 | M&L for 15 mm bore steel water tubing medium grade (ISI marked) galvanised with and including all tube fittings (ISI marked) concealed or fixed to wall, ceiling or laid in floors complete all as specified. |
| 34 | M&L for 20 mm bore steel water tubing medium grade (ISI marked) galvanised with and including all tube fittings (ISI marked) concealed or fixed to wall, ceiling or laid in floors complete all as specified. |
| 35 | S&F in repair 20 mm dia GI nipple for water tank with iron wheel head, screwed both ends for iron pipe and tank complete all as specified and as directed. |
| 36 | S&F in repair PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified. |
| 37 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore. |
| 38 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore. |
| 39 | S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint fixed to wall. |
| 40 | S&F in repair PVC (SWR) bends any radius 110mm bore. |
| 41 | S&F in repair PVC (SWR) bends any radius 75mm bore. |
| 42 | S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore complete all as specified. |
| 43 | S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore complete all as specified. |
| 44 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified. |
| 45 | M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) asin sub base of flooring etc complete all as specified. |
| 46 | M&Lfor Providing 100 mm thickPCC (cement concrete) 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates)as in hardstanding/ ramp/pathetc Spike rolling to surfaces or making impressions of expandedmetal,whilst the concrete is greenComplete all as specified and directed |
| 47 | M&L Forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade \"A\". Complete all as speicified and as directed |
| 48 | M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping , kerb, benching, gola and similar items all as specified and as directed |
| 49 | M&L for Sand filling in floors including levelling, watering and consolidation, complete all as specified and directed |
| 50 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and No pigment with designed pattern, complete all as specified and directed |
| 51 | M&L Non-skid coloured Endura outdoor tiles 18-20 mm thick (Square/rectangular) of each tile exc 0.06 Sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slury and pointed in coloured cement and pigment to match the tiles complete all as specified and as directed. |
| 52 | M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6for laying floor finishescomplete all as specified. |
| 53 | M&L chequered cement concrete coloured tiles 30cmx30 cmx25mm, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified. |
| 54 | Demolition ofPrecast cement concretekerb stone in any floors and paving not exc 15 cm thick above or below ground level all as specified and as directed. |
| 55 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 56 | M&Lfor preparation of new concrete surface and applying two coat of synthetic enamel paint exc 10 cm girth or width not other wise described over a coat of primer etc complete all as specified and as directed. |
| 57 | Dismantlingwatertanks Capacity of tank exc250 & n. exc 500 ltrs removing complete all as specified and as directed |
| 58 | Dismantlingwatertanks Capacity of tank exc500 & n. exc 1000 ltrs removing complete all as specified and as directed |
| 59 | Supply and fixingrotational moulded polyethylene three layered water storage tanks 500 litres capacity (cylindrical,vertical with closed top) hoisted and fixed in position all as specified and as directed. |
| 60 | Supply and fixingrotational moulded polyethylene three layered water storage tanks 1000 ltrs capacity (cylindrical,vertical with closed top) hoisted and fixed in position all as specified and as directed. |
| 61 | S & F in repair for Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed,Bore dia of pipe in 20 mm, etc complete all as specifed and directed. |
| 62 | S&F in repairs 20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed. |
| 63 | Removal of bushes , shurbs and vegetation by top of the roofand surface of bldg all as specified and directed by Engr-in-Charge |
| 64 | Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified. |
| 65 | Supply only intergral water proofing compound ISI Marked complete all as specified. |